05-1471-032SECURITY SYSTEM OUTLET BOX LEGEND O ALARM JUNCTION BOX - 6" x 6" x 4" BOX MOUNTED FLUSH IN THE WALL 60" FROM THE FLOOR TO CENTER LINE OF BOX. WHEN THE BOX IS UNABLE TO BE FLUSH MOUNTED, A PLYWOOD BACKBOARD 18" x 30" x 3/4" IS TO BE INSTALLED. O2 CENTRAL JUNCTION BOX - 12" x 12" x 6" WITH SCREW COVER. MOUNTED FLUSH WITH WALL 60" FROM FLOOR TO CENTER LINE OF BOX. MOUNT TWO DUPLEX RECEPTACLES INSIDE OF J -BOX 2. 3® NOT USED 3B SAFE SURVEILLANCE CAMERA - PEDESTAL MOUNTED IN THE CEILING. NO BOX REQUIRED. 3C ATM TRANSACTION CAMERA - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 60 "AFF ON THE RIGHT SIDE OF THE ATM VIEWED FROM THE REAR, 3/4 "C. TO ABOVE CEILING. 3D ATM SURVEILLANCE CAMERA - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED AS INDICATED. O AHD SURVEILLANCE CAMERA - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED AS INDICATED. O NOT USED. 3G DRIVE /THRU REMOTE UNIT CAMERA - UNIT MOUNTED. 3H VAULT SURVEILLANCE CAMERA - PEDESTAL MOUNTED. NO BOX REQUIRED.. 3J NOT USED. 3K AHD ROOM SURVEILLANCE CAMERA - PEDESTAL MOUNTED IN CEILING. NO BOX REQUIRED. O LOBBY CAMERA - WEDGE MOUNTED IN CEILING. NO BOX REQUIRED. VENDOR TO SELECT CAMERA TO FIT IN ENCLOSURE WHICH MAXIMIZES VIEWING AREA. COORDINATE WITH WACHOVIA. 3© NOT USED. 3N TELLER LINE CAMERA - WEDGE MOUNTED IN CEILING. NO BOX REQUIRED. ® DRIVE /THRU TELLER CUSTOMER UNIT MONITOR - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 18" ABOVE COUNTER TOP ON THE RIGHT AND /OR LEFT SIDE OF THE DRIVE /THRU WINDOW. 3/4 "C. TO ABOVE CEILING. O HOLD -UP BUTTON - HARD WIRED - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED 20 "AFF. 3/4 "C. TO ABOVE CEILING. O6 NOT USED. 7O VAULT SOUND DETECTOR - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH THE CEILING. ® VAULT DOOR ALARM - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED ON VAULT STEEL CEILING. O9 AFTER HOUR DEPOSITORY ALARM - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL. CENTERED OVER NIGHT DEPOSITORY CHEST AT 90-AFF. 3/4 "C. TO ABOVE CEILING. 10 ATM MACHINE ALARM - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 12" AFF ON THE RIGHT SIDE OF THE ATM VIEWED FROM THE REAR. 3/4 "C. TO ABOVE CEILING. 11 MAIN TELEPHONE BOARD - NO JUNCTION BOX REQUIRED, CONDUIT RUN TO TELEPHONE EQUIPMENT BOARD AND TERMINATE WITH BUSHING. SEE 3/E4. 12 ALARM INDICATOR LIGHT (BY SECURITY VENDOR)- 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH IN WALL 64 "AFF AND WITHIN 6" OF THE STRIKE SIDE OF THE DOOR FRAME. 3/4 "C. TO ABOVE CEILING. 13 VIDEO EQUIPMENT 13A - SEE VIDEO BOX DETAIL 2/E5. 14 SAFE - 4X4 BOX WITH 2 GANG PLASTER RING MOUNTED 75" AFF. 1/4" FLEX TO SAFE. 3/4 "C. TO ABOVE CEILING. 15 POWER RECEPTACLE - CONNECT TO UNSWITCHED 120 VOLT SECURITY CIRCUIT. 15A AT JB -01 - RECEPTACLE MOUNTED 66" AFF AND 10" TO THE SIDE OF JB -01 .. 15B AT JB- 2O -TWO DUPLEX RECEPTACLES MOUNTED INSIDE JB-Q ON SIDE WALLS OF BOX. 15C AT JB- 3g - TWO 4X4 BOXES WITH 2 GANG COVERS, ONE MOUNTED 12" AFF., ONE MOUNTED 18' AFF. PROVIDE TWO QUADRAPLEX OUTLETS. 15D AT JB -O4 - 4X4 BOX WITH 1 GANG COVER MOUNTED 18" ABOVE DRIVE /THRU COUNTER TOP TO THE RIGHT AND /OR LEFT OF JB -O4 . 16 MSK KEYPAD - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 54" AFF. 3/4 "C. TO ABOVE CEILING. 17 NOT USED. 18 NOT USED. 19 CASH DISPENSER MACHINE - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 18" AFF. 3/4 "C. TO ABOVE CEILING. ©0 MOTION DETECTOR - 4" OCTAGON BOX MOUNTED FLUSH WITH THE CEILING. SECURITY SYSTEM NOTES A. PRIOR TO ELECTRICAL ROUGH -IN OR RELOCATION, ELECTRICAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS, MOUNTING LOCATIONS, MOUNTING HEIGHTS, ELECTRICAL REQUIREMENTS, ETC. FOR BANK EQUIPMENT (DATA, SECURITY, DRIVE -UP TELLER WINDOW, PNEUMATIC - TELLERS, ATM, ETC.). ANY ADJUSTMENTS IN EQUIPMENT LOCATIONS PRIOR TO INSTALLATION SHALL BE PERFORMED AT NO EXTRA COST TO THE OWNER. B. IF OWNER DECIDES TO RELOCATE ANY EQUIPMENT, WALLS, ETC. AFFECTING THE LOCATION OF SECURITY SYSTEM JUNCTION BOXES OR CONDUIT, THE CONTRACTOR SHALL ADJUST SECURITY SYSTEM ACCORDINGLY TO ACCOMODATE SUCH CHANGES. IF CHANGES ARE MADE AFTER INSTALLATION OF THE SECURITY SYSTEM, THE CONTRACTOR SHALL INCLUDE SUCH CHANGES IN THE CHANGE ORDER TO THE CONTRACT. C. THE SECURITY SYSTEM SHOWN ON THESE PLANS IS SCHEMATIC AND QUANTITIES OF DEVICES MAY VARY DEPENDING ON THE SIZE AND COMPLEXITY OF THE SPECIFIC BUILDING. D. NOT USED. E. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT SIZES, DIMENSIONS, LOCATIONS AND MOUNTING OF BOXES WITH SECURITY SYSTEM VENDORS' SHOP DRAWINGS PRIOR TO ROUGH -IN. F. ALL VAULT CONDUIT TO BE CONTAINED WITHIN VAULT FLOOR, WALLS, OR CEILING. ALL CONDUIT FOR THE ALARM SYSTEM, SECURITY EQUIPMENT, LIGHTING, TELEPHONE, ETC. ENTERING THE VAULT WALLS, CEILING OR FLOOR SHALL HAVE AT LEAST ONE OFFSET WITHIN THE VAULT STRUCTURE. ARRANGEMENT OF BENDS SHALL BE SO THAT DRAINAGE IS TO THE EXTERIOR. SEE NATIONAL ELECTRICAL CODE FOR FURTHER INFORMATION. G. NO PVC CONDUIT WILL BE ALLOWED FOR ALARM CONDUIT AND NO CONDUIT SMALLER THAN 3/4" SHALL BE USED. H. ALL JUNCTION BOXES MUST HAVE BLANK COVER PLATE INSTALLED. I. ALL SECURITY OUTLETS SHALL HAVE COVER PLATES TO MATCH OUTLETS. J. OTHER DIVISIONS SHALL FURNISH AND INSTALL SECURITY CABLE IN ALL SECURITY CONDUITS. I I Notes: I I I I I I n I V I 1 "C. TO , 1 "C. TO , ABOVE CEILING ABOVE CEILING 3E 3D I I UNISEX WOMEW5 MEN'S RESTROOM RESTROOM RESTROOM ELEC. r VI IEO JB 1 -1 4 "C I no ul 112 u3 q TO I SEE NOTE #1 ELEC. ROOM I I 3C 4 19 5t i I �� I ---�, �G r - UN15EX M , i �� *EXCRIVE B DATA pM i TROOi� u3 � `.` �,� �, OS ATA a>s- -nlr ; �� 1�- ELEG. 20 + LER HEAD TELLER LINE 3N ' LI 3N 2 3N LO N II _I05-1 o D CORRIDOR Revisions: 104 r l08 1--- �GOR sID� 8 15 05 PLAN REVISION VVAUULLT I 1 822 05 PLAN REVISION Vhttl= t� 103 HEADI I 'OI 102 r —r — _ — _ _ _ — _ — — � O O O 9/23/05 PLAN REVISION — �Ir 20 1 1, 1 1 1 1 Io7 L 7 _/ OF FICE OFFICE OFFICE FFIGE FIM 7 1 3H (I ------------------- - - - - -- I t� 118 t1a LOUNGE - _4 - -� - - -- — — — — — — — — — — — — — — — — - - - - -- 1 "C. TO ABOVE CEILING li II ( I I 3L ii II 20 I OR -- --- r�� -- I I „ I VESTIBULE i i 20 I I 1# O loo II 1 ❑FROM JB ®THRU JB OT Q M �nm�nnml g� LOUNGE 204 O CORRIDOR CR 203 BANK EQUIPMENT NOTES ELEV. EQUIP 17-19AV. IP 127 � i ,,r '%! TELLER LECTURE 218 IL------ - ------ - - - - -- m m — — — — — — — — — — — — — — — — — — — — — — — OFFICE OFFICE ICE �FFICE ® a 0 1-25-1 122 123 ® ---------------------- - - - - -° 5 5 H A O O O LLJ Q - - -�- -- -� - - -� >�. ri 1ST FLOOR, PLAN - SECURITY EQUIP Imo' E5.1 SCALE: 1/8 "= 1' -0'1 NOTES: 1. SEE SYMBOLS, (SCHEDULES, NOTES AND DETAIL. 2. ALL CONDUIT T BE 3/4 "C TOAABOVE CEILING ONLY, UNLB . SECURITY NOT S: 1. 3 ®1 "C TO ABOVE CEILING. SE 19/Al2. 1 2. 1 -HOUR RATEd WALL. SEE 5/E7. 3. PLANS INDICAT� EMPTY CONDUIT AND BOXES FOR SECUIRTY ISYSTEM ONLY. ALL WIRING AND I DEVICES SHALLI BE PROVIDED BY OWNER. I TE�I RE5TROOM RE5TROOA RE5TROOM RESTROOM ROOMI RE5TROOM 20.1 208 208 210 211 212 Y G ; LN1 ,{ I+` 1 5 2 5 A� —_- _ 3 , - -- 20f� -1G�- GORRIDOPF - -� CORRIDOR 208 208 I I I I I I L - I TELLER TRANSACTION LECTURE TELLER CTION 2n TELLER GENERAL LECTURE LECTURE 218 218 BANK EQUIPMENT, INSTALLATION, AND SYSTEM REQUIREMENTS DRAWINGS FORM A PART OF THESE CONTRACT DOCUMENTS. ELECTRICAL SUBCONTRACTOR SHALL PROVIDE A OUTLET BOX AND CONDUIT SYSTEM AS INDICATED ON THE SECURITY SYSTEM BOX LEGEND AND THE DRAWINGS. BANK EQUIPMENT SUPPLIER SHALL PROVIDE DEVICES, CABLING AND OTHER ASSOCIATED EQUIPMENT, AND MAKE FINAL CONNECTIONS FOR A COMPLETED SYSTEM. OFFICE 213 i J_ T_q L---- MULTI MEDIA LEARING LAB 216 MULTI MEDIA LEARIN5 LAB 216 OJB1 NOTE: DO NOT SPLICE CABLES ,2 GOPY1 F 3/4 "C TO M TB 2 - 1-C TO ,3 _1 1# © (ONE EMPTY) IF SHOWN ON PLAN I I _T_ I 15 A Ol REVISION 01 .p� ■rN1Y .i 1 ALARM CONTROL BOX DET E6 SCALE: NTS MOUNT TROUGH 2 2ND FLOOR PLAN - SECURITY ABOVE CEILING E5.1 SCALE: 1/8 " =1' -0" 2 - 2`C. — NOTES: 1. SEE SYMBOLS, SCHEDULES, NOTES AND DETAILS. 2. ALL CONDUIT TO BE 3/4 "C TO ABOVE CEILING ONLY, UNLESS NOTED OTHERWISE. SECURITY NOTES: 1. 301"C TO ABOVE CEILING. SEE 19/Al2. 2. 1 -HOUR RATED WALL. SEE 5/E7. 3. PLANS INDICATE EMPTY CONDUIT AND BOXES FOR SECUIRTY SYSTEM ONLY. ALL WIRING AND DEVICES SHALL BE PROVIDED BY OWNER. "SUBJECT TO FIELD INSPECTION " SUBJECT TO FLORIDA BUILDING CODE PLUS LOCAL M NDMENTS BY: _-- --- CONDUIT AS NEEDED 2 #4❑ TO O I 8X8X24 I TROUGH Seal: onsu an s: 0 ARCHITECTURAL ENGINEERING INCORPORATED 3442 EAST UUT ROAD, PALM HARBOR. FL 34883 CONSULTING ENGINEERS (727) 784 -1472 CERTIFICATE OF AUTHORUAnoN: FL 3886 W. RONALD MCILVEEN FL PE 30270 go 41111I)p ♦qr w -aglow Ar , 10 ♦ �� .` E L E M E N T S ARCHITECTS -INTERIOR DESIGNERS Tampa Office The Edgewater Building 600 South- Magnolia Avenue Su,tE 150_ - Tampa, Florida 33206 Phone 213) 251 - ()569 Fa:: 1: 251 -0367 M i a rr1 -i- 0_ff i c e 4240 'jouthwest -3rd- Street- - Miami,lPori& -33:34 Phone (305) 441 -7617 Fax (305) 774 -1123 Nicholas Puglisi Arc'rtect L;-c�—_nse #AR12460 ELEMENTS State_ License 1 ".0002341 WACHOVIA " 2 _ 2•C. CEILING 2 CHASE NIPPLE WITH WEST GABLES BRANCH PLASTIC BUSHING IN 5880 BIRD ROAD THE COVER. (TYP -2) MIAMI, FLORIDA 12 "X12 "X4" Drawing No. /Date 5/2/05 a (TYP. FOR 2) E5.1 5-0 18" 40" (MAX) ,, 04- 028/05143 FLOOR Drawing Title /Scale /Drawn by EVD ELECTRICAL SECURITY FLOOR ' TO VIDEO JB PLANS -NEW WORK AT TELLER WINDOW SCALE: SEE 4/E7 2 VIDEO BOX DETAIL E5 SCALE: NTS