Loading...
05-1471-025GENERAL NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES HAVING JURISDICTION. 2. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF HIS WORK. 3. CONTRACTOR SHALL VISIT THE SITE AND EXAMINE CONDITIONS OF THE PREMISES AND THE CHARACTER AND EXTENT OF WORK REQUIRED PRIOR TO SUBMISSION OF BIDS. ANY DIFFICULTIES IN COMPLYING WITH THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER BEFORE BIDDING. 4. IT IS THE INTENT OF THESE DRAWINGS AND OTHER RELATED DOCUMENTS TO PRODUCE A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL AND OTHER SERVICES AS MAY BE NECESSARY TO ACHIEVE THIS PRODUCT. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY DISCREPANCIES IN THE PLANS AND SPECIFICATIONS THAT WILL AFFECT THE WORK, PRIOR TO SUBMISSION OF HIS BID PRICE. 5. IF, DURING THE COURSE OF THE WORK, THE CONTRACTOR EXPER- IENCES A PROBLEM WITH THE PERFORMANCE OF THE INSTALLATION RELATIVE TO THE PLANS AND SPECIFICATIONS, THE NATIONAL ELEC- TRICAL CODE, OTHER APPLICABLE CODES AND GOVERNING DOCUMENTS, THE CONTRACTOR SHALL BRING THE PROBLEM TO THE ATTENTION OF THE ARCHITECT AND /OR THE ENGINEER FOR RESOLUTION PRIOR TO EXECUTION OF THE WORK. 6. ALL MATERIAL SHALL BE NEW AND BEAR THE U.L. LABEL LISTED APPROVAL FOR ITS INSTALLED APPLICATION. 7. ALL MAJOR COMPONENTS OF THE ELECTRICAL SYSTEMS SUCH AS SAFETY DISCONNECT SWITCHES, AND PANELBOARDS SHALL BE BY THE SAME MANUFACTURER AND SHALL BE ONE OF THE FOLLOWING: SQUARE "D" COMPANY, GENERAL ELECTRIC, OR CUTLER- HAMMER. 8. CIRCUIT BREAKERS USED FOR SWITCHING OF LIGHTING OR SIGN CIRCUITS SHALL BE APPROVED FOR SWITCHING DUTY AND SHALL BE MARKED "SWD" IN ACCORDANCE WITH N.E.C. ART. 240.83 (D). 9. PROVIDE "LOCKING" TYPE DEVICES ON ALL CIRCUIT BREAKERS CONNECTED TO EMERGENCY AND NIGHT LIGHTING, SIGNS, FIRE ALARM, SECURITY SYSTEMS, AFTER HOUR DEPOSIT AND AUTOMATIC TELLER MACHINES. 10. ALL SWITCHES, DUPLEX RECEPTACLES, AND TELEPHONE OUTLETS TO BE FLUSH MOUNTED, THROUGHOUT. 11. ALL SERVICE EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. ARTICLE 250. 12. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCA11ONS OF HVAC EQUIPMENT. 13. SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT FIXTURES. 14. ELECTRICAL PLANS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS. 15. CONSULT PLANS OF ALL OTHER TRADES FOR COORDINATION AND FOR RELATED AND ADJOINING WORK. 16. CONSULT ARCHITECTURAL AND STRUCTURAL PLANS AND DETAILS FOR CONSTRUCTION TYPE, HEADROOM, ROOM FINISHES, CEILINGS, ETC. 17. ALL WORK SHALL BE DONE AT SUCH 11MES AND IN SUCH A MANNER AS WILL LEAST INTERFERE WITH THE MAINTENANCE AND OPERATION OF ALL RELATED OR AFFECTED SYSTEMS. ALL POWER OUTAGES SHALL BE COORDINATED WITH OWNER. 18. THE CORRECT NUMBER OF WIRES MAY NOT BE INDICATED FOR ALL CIRCUITS, ONLY THOSE WHERE CLARIFICATION IS NECESSARY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRES NECESSARY FOR THE PROPER FUNCTION OF THE SYSTEM. 19. ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FT. SHALL BE PROVIDED WITH A PULL WIRE OR FISH TAPE /CORD. 20. ALL BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL BE INCREASED TO THE NEXT LARGER SIZE WHERE THE LENGTH OF THE HOME RUN EXCEEDS 100 FT. ON 120/208V CIRCUITS. 21. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER SIZING OF ALL MOTOR OVERLOAD DEVICES (HEATERS) IN STARTERS BASED ON ACTUAL NAMEPLATE RATINGS ON THE MOTORS BEING INSTALLED. 22. CONTRACTOR SHALL NOTE U.L. LABELS ON PACKAGE TYPE MECHANICAL EQUIPMENT. IF U.L. LABEL ON MECHANICAL EQUIPMENT CALLS FOR THE OVERCURRENT PROTECTIVE DEVICE TO BE FUSES, THE ELECTRICAL CON- TRACTOR SHALL PROVIDE A FUSED DISCONNECT SWITCH WITH PROPER SIZE FUSES AT THE SWITCH LOCATION INDICATED ON DRAWINGS. 23• CONTRACTOR SHALL VERIFY WIRE SIZES, C/B AND FUSE RATINGS FOR ALL HVAC EQUIPMENT, AND BRING TO THE ATTENTION OF THE ARCHITECT AND /OR THE ENGINEER ANY DISCREPANIES AFFECTING THE WORK PRIOR TO PROCEEDING. 24. HORSEPOWER RATINGS INDICATED ON DRAWING MAY DIFFER FROM ACTUAL EQUIPMENT FURNISHED. IF FURNISHED EQUIPMENT DIFFERS FROM RATINGS ON DRAWINGS, CONTRACTOR SHALL NOTIFY ARCHITECT AND /OR THE ENGINEER FOR APPROPRIATE ACTION TO BE TAKEN. 25. PROVIDE APPROVED "HACR" TYPE CIRCUIT BREAKERS FOR ALL HEATING, AIR CONDITIONING, AND REFRIGERATION EQUIPMENT INDICATED FOR CONNECTION ON ELECTRICAL DRAWINGS. 26. ALL DEVICES AND COVERPLATES SHALL BE CONSTRUCTED OF MOLDED NYLON MATERIALS. COLOR OF DEVICES AND MATCHING COVERPLATES SHALL BE AS SELECTED BY THE ARCHITECT. 27. THE CONTRACTOR SHALL GUARANTEE ALL HIS WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 28. IT SHALL BE THE RESPONSIBLITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE SERVICE REQUIREMENTS FOR POWER AND TELEPHONE UTILITIES. 29. PROVIDE A #10 NEUTRAL CONDUCTOR FOR ALL MULTIWIRE RECEPTACLE BRANCH CIRCUITS. 30. FOR ALL EQUIPMENT RATED 100AMPS OR LESS, E.C. SHALL PROVIDE TERMINATIONS WHICH ARE LISTED FOR USE AT 75'C OR PROVIDE WIRING SIZED USING THE 60'C AMPACITY. 31. RECEPTACLES ON SEPARATE CIRCUITS SHALL BE RATED 20 AMP, 120 VOLT. 32, WIRE AND CABLE SHALL BE COPPER, TYPE THHN /THWN, MINIMUM #12 AWG. 33. PANELBOARD DIRECTORIES SHALL BE UPDATED TO REFLECT ALL WORK DONE AS PART OF THIS PROJECT. 34. ALL NEW BRANCH CIRCUITS SHALL BE EQUIPPED WITH A MINIMUM #12 AWG GREEN EQUIPMENT GROUND CONDUCTOR. 35. CONDUIT RUN UNDERGROUND SHALL BE PVC SCHEDULE 40. ALL BUILDING WIRING SHALL BE RUN IN METALLIC CONDUIT. INTERIOR CONDUIT SHALL BE EMT. EXTERIOR CONDUIT SHALL BE IMC OR RMC. 36. FOR IG RECEPTACLES, PROVIDE 2 #12 GREEN GROUND WIRES IN BRANCH CIRCUIT BACK TO PANELBOARD. PHASING NOTES 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL THE NEW ELECTRIC SERVICE, MAINTAIN THE EXISTING SERVICE (COORDINATE WITH AUTHORITY HAVING JURISDICTION) 2. FIELD VERIFY ALL EXISTING 240V -30 EQUIPMENT, CONVERT TO 208V -30 AN CONNECT TO NEW SERVICE AS REQUIRED (EXISTING ROOFTOP UNITS, ETC.). 3. BACK FEED THE EXISTING 800A 240V -30 SERVICE FROM THE NEW 208V -30 SERVICE WITH A TEMPORARY 800 AMP 3 POLE CIRCUIT BREAKER AND ENCLOSURE, 2 SETS OF 4#500 MCM CU, 1 1 /O IN 2 -4" CONDUITS (TAP THE LOAD SIDE OF THE 1200 AMP MAIN CIRCUIT BREAKER AS REQUIRED). 4. FIELD COORDINATE ALL PHASING OF THE INTERIOR RENOVATION WITH THE GENERAL CONTRACTOR. LIGHTING FIXTURE SCHEDULE TOTAL '1 � r�! -•, ;�„�'� TYPE DESCRIPTION N0./LAMPS MANUFACTURER CATALOG NUMBER BALLAST TYPE FIXTURE VOLTS REMARKS VA RECESSED DIRECT /INDIRECT OA 2' X 4' LAY -IN 3 -F32T8 METALUX 2RD1332RP120 -EB81 ELECTRONIC 96 120 FLUORESCENT WITH CENTER BASKET SAME AS TYPE A EXCEPT FIXTURE TO BE PROVIDED WITH Al 2' X 4' LAY -IN 3 -F32T8 METALUX 2RD1332RP1 20-EB81 -EL4 ELECTRONIC 96 120 SELF - CONTAINED EMERGENCY BATTERY INVERTER RATED FOR 11/2 HOUR BACKUP PER NFPA -101 ELECTRONIC SAME AS TYPE 'A' EXCEPT A2 2' X 4' LAY -IN 3 -F32T8 METALUX 2RD1332RP120 -EB82 2 -LAMP 1 -LAMP 96 120 WITH INBOARD - OUTBOARD SWITCHING SME AS TYPE ' EXCEPT WITH ELECTRONIC INBOARD - OUTBOARD SWITCHING FIXTURE A3 2' X 4' LAY -IN 3 -F32T8 METALUX 2RD1332RP120- EB82 -EL4 2 -LAMP 96 120 TO BE PROVIDED WITH SELF - CONTAINED 1 -LAMP EMERGENCY BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 2' X 4' LAY -IN 3 -F32T8 METALUX 2GC332A125- 120 -EB82 ELECTRONIC 96 120 PROVIDE Al2.125 PRISMATIC ACRYLIC LENS MTD. IN A FLUSH STEEL DOOR © 2 -LAMP 1-LAMP FRAME. 61 2' X 4' LAY -IN 2 -F32T8 METALUX 2GC232A125- 120 -EB81 ELECTRONIC 64 120 PROVIDE Al2.125 PRISMATIC ACRYLIC LENS MTD. IN A FLUSH STEEL DOOR FRAME. (NOT USED) SAME AS TYPE '131' EXCEPT FIXTURE TO BE PROVIDED WITH B2 2' X 4' LAY -IN 2 -F32T8 METALUX 2GC232A1 25--120-EB81 -EL4 ELECTRONIC 64 120 SELF - CONTAINED EMERGENCY BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 RECESSED DIRECT /INDIRECT O 2' X 2' LAY -IN 3 -F17T8 METALUX 2RD1217RP120 -EB81 MAGNETIC 51 120 FLUORESCENT WITH CENTER BASKET SAME AS TYPE 'C' EXCEPT C1 2' X 2' LAY -IN 3 -F17T8 METALUX 2RD1217RP1 20-EB81 -EL4 MAGNETIC 51 120 FIXTURE TO BE PROVIDED WITH SELF - CONTAINED EMERGENCY BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 O 4' STRIP 2 -F32T8 METALUX SS232120 -EB81 ELECTRONIC 64 120 4' STRIP, 2 LAMP. SURFACE MOUNTED O RECESSED 2/26W ZUMTOBEL CLU8204U99 /FAC -C/ ELECTRONIC 52 120 STANDARD HOUSING, 8" DIAMETER FACETTED REFLECTOR, CLEAR DOWN LIGHT SAR -C /SAT -L SATURN GLASS ACCESSORY, LIME STANDARD HOUSING, 7 3/8" DIAMETER RECESSED 2/26W PORTFOLIO C7226 -E- 7251 -LI ELECTRONIC 52 120 ONE PIECE ALZAK REFLECTOR, WITH © DOWN LIGHT SPUN PARABOLIC CONTOUR SINGLE RING, MATTE ANODIZED ALUMINUM SAME AS TYPE 'G' EXCEPT FIXTURE TO BE PROVIDED WITH RECESSED 2/26W PORTFOLIO C7226 -EEM- 7251 -LI ELECTRONIC 52 120 SELF - CONTAINED EMERGENCY G1 DOWN LIGHT BATTERY INVERTER RATED FOR 1 1 /2 HOUR BACKUP PER NFPA -101 FIXTURE SHALL HAVE FLANGE FOR RECESSED MOUNTING IN GYPSUM BOARD CEILING. DIE FORMED STEEL HOUSING, SEMI - SPECULAR CELL O RECESSED HID 1 -40OW LUMARK MHQP -S4/16/GL- 400 -208- MAGNETIC 460 208 ALUMINUM LOUVER R WITH CLEAR METAL DL -FTW 1PH TEMPERED GLASS OVERLAY HALIDE, CLEAR UL LISTED FOR DAMP LOCATION (NOT USED) SAME AS TYPE H EXCEPT RECESSED HID 1 -40OW LUMARK MHQP- S4 /16 /GL- 400 -208- MAGNETIC 460 208 FIXTURE TO BE PROVIDED WITH H1 M.H. AND DL -EM -FTW 1PH QUARTZ RE- STRIKE SYSTEM (NOT USED). METAL SIDES, FLUSH STEEL 2' X 4' 4 -F32T8 METALUX 2M- 432A125- 120 -EB81 ELECTRONIC 128 120 DOOR FRAME AND Al2.125 O SURFACE MOUNTED PRISMATIC ACRYLIC LENS (NOT USED). SAME AS TYPE 'I' EXCEPT . FIXTURE TO BE PROVIDED WITH 11 4 -F32T8 METALUX 2M- 432A125- 120 -EB81 -EL4 ELECTRONIC 128 120 SELF - CONTAINED EMERGENCY SURFACE MOUNTED BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 Oj REMOTE EMERGENCY 8W HALOGEN SURE -LITES 12T- 8 -DWBK - 8 12V MOUNT 8' -O "AFF TO TOP. HEAD 37W DESIGN PLAN ITS6161022FTO - 37 12V l,Ll. SURFACE MOUNTED CHECK NANIEI O REMOTE EMERGENCY MR16 LOW VOLTAGE DOWNLIGHT EQu1P}1aE,1T, H< HEAD FL40 WITH BLACK FINISH AND OTHER T CORRECT �� I NOT USED). 017rDely L O 7" x 4' LAY -IN 2 -F28T5 INSIGHT LR /PS5 /SA(2) /T5/28W/ ELECTRONIC 56 120 MFRECESSED WALL WASH ADE UATE SE. ; UST BE 4'/1 /W /KAB LUORESCENT WITH SUf3JECI' T. ROTATABLE OPTICS F ALUMINUM HOUSING, EXTRUDED ALUMINUM DOOR FRAME, TEMPERED GLASS LENS, EXTRUDED 10" ALUMINUM ARM, SQ. O POLE MOUNTED 'SHOE 1 -40OW LUMARK MHHR -R3- 400 - 208- OA1062- MAGNETIC 460 208 25' -0" STEEL POLE WITH MOUNTING HARDWARE AND BASE BOX' TYPE SITE METAL DBZ- SSS5A25SF -M -DBZ 1PH COVER, POLE AND FIXTURE TO LIGHTING FIXTURE HALIDE, BE FINISHED IN DARK BRONZE. CLEAR TES TYPE III DISTRIBUTION, BALLAST TO BE H.P.F., C.B.M., U.L. LISTED FOR WET LOCATIONS NOT USED). POLE MOUNTED 'SHOE 2 -40OW LUMARK MHHR -R3- 400 - 208- OA1062- MAGNETIC 920 208 SAME AS TYPE 'T' EXCEPT O BOX' TYPE SITE METAL DBZ- SSS5A25SF -2M -DBZ 1PH FIXTURE TO BE PROVIDED WITH LIGHTING FIXTURE HALIDE, 2 -40OW FIXTURES AT 180 DEGREES CLEAR (NOT USED). DIE CAST ALUMINUM HOUSING, DOOR FRAME, AND SWIVEL. PROVIDE TEMPERED GLASS LENS, O GROUND MOUNTED HID 1 -175W M.H. KIM AFL2175MH120BL -P MAGNETIC 200 120 SPECULAR ALZAK REFLECTOR HORIZONTAL AND H.P.F., C.B.M. BALLAST FLOOD LIGHTING PROVIDE TENON BASE MOUNT FIXTURE U.L. LISTED FOR WET LOCATIONS (NOT USED). MTG & FACE AS INDICATED ON EXIT LIGHT LED SURE -LITES CX717ORW NA 8 120 DRAWINGS. PROVIDE SELF CONTAINED O BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 AREA OF REFUGE SIGN AREA OF REFUGE LIGHT LED LSI EX2RW 120 NA 8 120 "AREA OF REFUGE" WITH HANDICAP O ACCESSIBLE ICON 11/2 HOUR BACKUP PER NFPA -101 x 5 -1 /8"W x 1- 13/16 "H OUNDERCABINET Z LIGHT LED METALUX CL- 1- 32 -LTS- 120- GL -TEB81 ELECTRONIC 32 120 UNDERCABINET LIGHT UND EM EMERGENCY LIGHTING SURE -LITES GC- 1505 -NH - 36 120 ELECTRICAL SYMBOL LEGEND �LV � 0 00 00 00 0 ro O El I--O -� S HOMERUN TO PANELBOARD. NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS. CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING. CONDUIT RUN CONCEALED IN OR BELOW FLOOR OR UNDERGROUND. CONDUIT RUN EXPOSED LOW VOLTAGE WIRING SERVICE OR EQUIPMENT GROUND. JUNCTION BOX FLUSH MOUNTED UNLESS INDICATED OTHERWISE. PANELBOARD (SURFACE MOUNTED). TELEPHONE EQUIPMENT BACKBOARD, SEE TELEPHONE AND SATELLITE SCHEMATIC NOTES. RECESSED FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. DARKENED HALF IN ANY LIGHTING FIXTURE SYMBOL SHOWN HEREIN INDICATES THAT FIXTURE SHALL CONTAIN ASELF- CONTAINED BATTERY PACK DARKENED HALF IN ANY LIGHTING FIXTURE WITH NL SYMBOL SHOWN HEREIN INDICATES THAT FIXTURE IS ON UNSWITCHED NIGHT LIGHTING SYSTEM, W /SELF- CONTAINED BATTERY PACK AND INVERTER CEILING MOUNTED INCANDESCENT OR FLUORESCENT OR HID FIXTURE. WALL MOUNTED FLUORESCENT OR HID FIXTURE. 2X2 RECESSED HID OR FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. DARKENED CIRCLE IN ANY DOWNLIGHT FIXTURE SYMBOL SHOWN HEREIN INDICATES THAT FIXTURE IS ON UNSWITCHED NIGHT LIGHTING SYSTEM, W /SELF- CONTAINED BATTERY PACK AND INVERTER CEILING MOUNTED EXIT LIGHT. SINGLE FACE, BLACKENED AREA REPRESENTS FACE WALL MOUNTED EXIT LIGHT. SINGLE FACE, BLACKENED AREA REPRESENTS FACE. GROUND MOUNTED H.I.D TYPE FLOOD LIGHT FIXTURE. LETTER INDICATES TYPE. SURFACE FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. SINGLE POLE SWITCH IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, UNLESS HEIGHT IS OTHERWISE NOTED ON PLAN. =q G cj? O Z S3 THREE -WAY SWITCH IN OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR. C WALL MOUNTED TYPE MOTION DETECTOR SWITCH IN FLUSH MOUNTED OUTLET BOX, D 48" ABOVE FINISHED FLOOR. �® 125 -VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 18 INCHES ABOVE FINISHED FLOOR. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DOUBLE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, =4 18" ABOVE FINISHED FLOOR. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DOUBLE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE DESK /COUNTERTOP, OR 2 INCHES ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. SEE GENERAL NOTE 31. M-1 = ®WP = ®GFI = ®IG -e WA 10 O�►i • e RI .:liluw tit• kutic;k; NC, \TE DATA (y 4+/C: WATER HLN! ERS ',ti1ENT TO Oi TA! r \F SIZES AND 'PROTECTION. /ICE CApA(Cr+­, I ROVIDEP --LECTR r TV • -TION 0 9 30 EP 30 a3R IF • U Av AR V O E.C. IG W.P. MTB NIL FPN NF 125 -VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE DESK /COUNTERTOP, OR 2 INCHES ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE WITH STAINLESS STEEL WEATHERPROOF COVER, 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE GROUND FAULT INTERRUPTER TYPE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE ISOLATED GROUND TYPE RECEPTACLE IN FLUSH OUTLET BOX 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. 120 -VOLT, 30A, 3 WIRE GROUNDED TYPE RECEPTACLE IN FLUSH OUTLET BOX F14 *0 �NfCCI to NEMA 5 -30R SPFCTj4 SPECIAL OUTLET AS NOTED ON THE PLANS. PROVIDE NEW WALKER RFB4 SERIES CAST IRON FLOOR BOX, FOR CONCRETE ON GRADE, WITH S36BBT -CAL COVER PLATE. COORDINATE COLOR WITH OWNER. PROVIDE WITH TWO DUPLEX N5 -15R OUTLETS. STUB 1 "EC FROM COMMUNICATIONS COMPARTMENTS TO ACCESSIBLE CEILING SPACE OR AS INDICATED ON DRAWINGS. FLUSH OUTLET BOX FOR WALL - MOUNTED TELEPHONE 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE COUNTERTOP, OR AT HEIGHT INDICATED ON PLAN, WITH 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. TELEPHONE /DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER WITH (1) 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. DEVICE TO BE 18" AFF OR AS NOTED. TELEPHONE /DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER WITH (1) 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. DEVICE TO BE 48" AFF, 6" ABOVE DESK /COUNTERTOP, OR 2" ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. FLUSH OUTLET BOX AND TELEVISION COVERPLATE 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE COUNTERTOP, OR AT HEIGHT INDICATED ON PLAN, WITH 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. MUST COMPLY WITH: CONNECTION TO FRACTIONAL HORSEPOWER ELECTRIC MO OR. PHOTOELECTRIC CELL. MOUNT 10' -6" AFF TO TOP. N. F. P. A. # F. B. C. MECHANICALLY HELD LIGHTING CONTACTOR. TIME CLOCK. NON- FUSIBLE DISCONNECT SWITCH IN NEMA -1 ENCLOSURE. SUBSCRIPT NUMERAL INDICATES SWITCH RATING IN AMPERES. PROVIDE NUMBER OF POLES AS REQUIRED, VOLTAGE RATING AS REQUIRED. 3R INDICATES NEMA -3R ENCLOSURE. FUSED DISCONNECT SWITCH IN NEMA -1 ENCLOSURE. SUBSCRIPT NUMERAL INDICATES SWITCH RATING IN AMPERES. PROVIDE NUMBER OF POLES AS REQUIRED, VOLTAGE AS REQUIRED. 3R INDICATES NEMA -3R ENCLOSURE. FUSE SIZE AS INDICATED. DISCONNECT FURNISHED WITH EQUIPMENT ` �� nr. SURGE SUPPRESSOR ANY PLAN DEVIATION CONNECTION TO VAV BOX MUST DE A;`-` t0V EU LEi-O R _ RECALL SMOKE DETECTOR INSPECTION REQUEST DUCT MOUNTED SMOKE DETECTOR AREA OF REFUGE MASTER CONTROL PANEL HOUSING DEVICES INC. #ADA- 100 -ECS SYSTEM MASTER AREA OF REFUGE STATION HOUSING DEVICES INC. #ADA- 100 -ECS SYSTEM AREA STATION CALL FOR AID PULL SWITCH PACIFICE ELECTRONICS #206 CALL FOR AID AUDIO /VISUAL UNIT PACIFIC ELECTRONICS #3021B WITH TRANSFORMER #P598 SECURITY SYSTEM OUTLET. NUMERAL IDENTIFIES OUTLET. SEE SECURITY SYSTEM BOX LEGEND. EMPTY CONDUIT WITH PULLCORD INDICATES ISOLATED GROUND WEATHERPROOF MAIN TELEPHONE BOARD NIGHT LIGHTING FUSE PER NAMEPLATE NON -FUSED Notes: Revisions: 8/15/05 PLAN REVISION 8 /22/05 PLAN REVISION )/23/05 PLAN REVISION Seal: Consultants: 0 ARCHITECTURAL ENGINEERING INCORPORATED 3442 EAST LAKE ROAD. PALM WSW. R. 34585 CONSULTING ENGINEERS (727) 784 -1472 CEi11F1CATE OF AUMORaATION: FL 3888 W. RONALD MCILVEEN FL PE 30270 s , • ♦ �I E L E M E N T S 1 ARCHITECTS -INTERIOR DESIGNERS Tampa Office The Edgewater Building 600 South Magnolia Avenue Suite 150 Tampa, Florida 33606 Phone (813) 251 -0565 Fax (813) 251 -0567 Miami Office- _ 4240 Southwest 3rd, Street - - Miami, Florida 3134 ,-- Phone (305) 4417617 hvx (205) 774--:',123 Nicholas Puglis- Architect Ucense #AR12460 ELEMENTS State License _#HA0002341 NVACHOWAL WEST GABLES BRANCH 5880 BIRD ROAD MIAMI, FLORIDA Drawing No. /Date 5/2/05 E0.1 04- 028/05145 Drawing Title /Scale /Drawn by E\/D ELECTRICAL DETAILS SCALE: '1 � r�! -•, ;�„�'� -_ cal -� ne Consultants: 0 ARCHITECTURAL ENGINEERING INCORPORATED 3442 EAST LAKE ROAD. PALM WSW. R. 34585 CONSULTING ENGINEERS (727) 784 -1472 CEi11F1CATE OF AUMORaATION: FL 3888 W. RONALD MCILVEEN FL PE 30270 s , • ♦ �I E L E M E N T S 1 ARCHITECTS -INTERIOR DESIGNERS Tampa Office The Edgewater Building 600 South Magnolia Avenue Suite 150 Tampa, Florida 33606 Phone (813) 251 -0565 Fax (813) 251 -0567 Miami Office- _ 4240 Southwest 3rd, Street - - Miami, Florida 3134 ,-- Phone (305) 4417617 hvx (205) 774--:',123 Nicholas Puglis- Architect Ucense #AR12460 ELEMENTS State License _#HA0002341 NVACHOWAL WEST GABLES BRANCH 5880 BIRD ROAD MIAMI, FLORIDA Drawing No. /Date 5/2/05 E0.1 04- 028/05145 Drawing Title /Scale /Drawn by E\/D ELECTRICAL DETAILS SCALE: