05-1471-003SECOND FLOOR
N
BUILDING CODE INFORMATION:
CODES UTILIZED: FLORIDA BUILDNG CODE, 1001
BUILDING SQUARE FOOTAGE FIRST FLOOR: 6 ,331
BUILDING SQUARE FOOTAGE SECOND FLOOR: 6 ,331
BUILDING SQUARE FOOTAGE TOTAL: 12,614
OCCUPANCY TYPE: BUSINESS
OCCUPANCY LOAD: I PERSON/100 S .F. GROSS (12,614 SPJ100 SP. = 121 PEOPLE)
BUILDING TYPE: TYPE V, UN- SPRNKLERED, UN- PROTECTED
SCOPE OF WORK INTERIOR REMODEL OF EXISTING
OCCUPANT LOAD FOR SECOND FLOOR CLASSROOMS
ALL SECOND FLOOR CLASSROOMS SHALL BE UTILIZED FOR
EDUCATIONAL PURPOSES ABOVE GRADE 12.
OCCUPANT LOAD PER FBC 2001 TABLE 1003.1 ■ 1 PERSON/20 NET SQ FT.
TELLER LECTURE (RM 219) ■ 660 Sa FT. / 20 NET ■ 33 OCCUPANTS
GENERAL LECTUFE ( RM.118) ■ 519 Sa FT. l 10 NET ■ 29 OCCUPANTS
TELLER TRANSACTION CLASSROOM 04t 211) = 151 SQ FT. / 20 NET = 38 OCCUPANTS
MULTI -MEDIA LEAWING CLASSROOM (W. 216) = 511 SQ FT. / 10 NET = 26 OCCUPANTS
READY TALENT / LECTURE (81.215) = 1,140 SQ FT. / 20 NET = 51 OCCUPANTS
GENERAL NOTES:
I. DO NOT SCALE DRAWINGS, DIMENSIONS GOVEF;K LARGE SCALE DETAILS
GOVERN OVER SMALL SCALE.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR SEEING THAT NEW
CONSTRUCTION CONFORIS TO ALL APPLICABLE STATE AND
MUNICIPAL CODES INCLUDING ALL STATE LAWS, LOCAL APPLICABLE
REQUIREMENTS OF THE FLORIDA BUILDING CODE, FLORIDA
ACCESSIBILITY GUIDELINES AND THE AMERICANS WITH DISABILITIES
ACT.
3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS PRIOR
TO FABRICATION, (TYPICAL).
4. PROVIDE WALL BRACING/BLOCKING AS NECESSARY FOR ALL
WALL MOUNT CABINETS, FIXTURES, AND EQUIPMENT.
�� ��� REVISION
LEGEND
SYMBOL DESCRIPTION
N
NORTH ARROW
DOOR AND DOOR TAG. REFER TO DOOR
IOIA
SCHEDULE FOR SPECIFICATIONS
X
)00(
INTERIOR ELEVATION MARK
P -5
PARTITION TYPE SEE SHEET A5J
x
1
ENLARGED DETAIL MARK
\r/
DIMENSIONS:
INDICATES DIMENSION TO FACE OF G.W.B.
PARTITIONS OR COL.
INDICATES DIMENSION TO FACE OF EXISTING
CONSTRUCTION
NOTE: VERIFY ALL EXISTING DIMENSIONS N FIELD
EXISTING PORTIONS OF BUILUINr ,.� "'I'- C". �t
WITH THE PROVISIONS OF EXISTING OCCUrAiJ`.',IS"
AS SET FORTH IN THE FLORIDA FIRE PREVENTION C=i,
Notes:
Revisions:
1 8 -15 -05 PLAN REVISION
8 -22 -05 PLAN REVISION
S -IS -05 PLAN REVISION
,t
L Al
onsulta
I
1
E L E M E N T S
ARCHITECTS - INTERIOR DESIGNERS
Tampa Office
The Edgewater Building
600 South Magnolia Avenue
Suite 150
Tampa, Florida 33606
Phone 813" 5: -0565
Fax 8135 -25!-0567---
Miami- Offic ;a
4240 Southwest- 3rd - Street
Miami, Flcrid? 33134
Phone -441 -7517
Fax �0 774-1-12S,
Nicholas Puglisi Architect - LiceniW #M124 0
ELEMENTS State License #AA0002341
W'kCHOVIA - = -
WEST eAKES BRANCH
5880 BIRD ROAD
MIAMI, FLORIDA
Drawing No. /Date 8/1/05
A-3.2
04 -028
Drawing Title /Scale /Drawn by BDL
SECOND FLOOR PLAN
SCALE.- AS NOTED