05-1471-003SECOND FLOOR N BUILDING CODE INFORMATION: CODES UTILIZED: FLORIDA BUILDNG CODE, 1001 BUILDING SQUARE FOOTAGE FIRST FLOOR: 6 ,331 BUILDING SQUARE FOOTAGE SECOND FLOOR: 6 ,331 BUILDING SQUARE FOOTAGE TOTAL: 12,614 OCCUPANCY TYPE: BUSINESS OCCUPANCY LOAD: I PERSON/100 S .F. GROSS (12,614 SPJ100 SP. = 121 PEOPLE) BUILDING TYPE: TYPE V, UN- SPRNKLERED, UN- PROTECTED SCOPE OF WORK INTERIOR REMODEL OF EXISTING OCCUPANT LOAD FOR SECOND FLOOR CLASSROOMS ALL SECOND FLOOR CLASSROOMS SHALL BE UTILIZED FOR EDUCATIONAL PURPOSES ABOVE GRADE 12. OCCUPANT LOAD PER FBC 2001 TABLE 1003.1 ■ 1 PERSON/20 NET SQ FT. TELLER LECTURE (RM 219) ■ 660 Sa FT. / 20 NET ■ 33 OCCUPANTS GENERAL LECTUFE ( RM.118) ■ 519 Sa FT. l 10 NET ■ 29 OCCUPANTS TELLER TRANSACTION CLASSROOM 04t 211) = 151 SQ FT. / 20 NET = 38 OCCUPANTS MULTI -MEDIA LEAWING CLASSROOM (W. 216) = 511 SQ FT. / 10 NET = 26 OCCUPANTS READY TALENT / LECTURE (81.215) = 1,140 SQ FT. / 20 NET = 51 OCCUPANTS GENERAL NOTES: I. DO NOT SCALE DRAWINGS, DIMENSIONS GOVEF;K LARGE SCALE DETAILS GOVERN OVER SMALL SCALE. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR SEEING THAT NEW CONSTRUCTION CONFORIS TO ALL APPLICABLE STATE AND MUNICIPAL CODES INCLUDING ALL STATE LAWS, LOCAL APPLICABLE REQUIREMENTS OF THE FLORIDA BUILDING CODE, FLORIDA ACCESSIBILITY GUIDELINES AND THE AMERICANS WITH DISABILITIES ACT. 3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS PRIOR TO FABRICATION, (TYPICAL). 4. PROVIDE WALL BRACING/BLOCKING AS NECESSARY FOR ALL WALL MOUNT CABINETS, FIXTURES, AND EQUIPMENT. �� ��� REVISION LEGEND SYMBOL DESCRIPTION N NORTH ARROW DOOR AND DOOR TAG. REFER TO DOOR IOIA SCHEDULE FOR SPECIFICATIONS X )00( INTERIOR ELEVATION MARK P -5 PARTITION TYPE SEE SHEET A5J x 1 ENLARGED DETAIL MARK \r/ DIMENSIONS: INDICATES DIMENSION TO FACE OF G.W.B. PARTITIONS OR COL. INDICATES DIMENSION TO FACE OF EXISTING CONSTRUCTION NOTE: VERIFY ALL EXISTING DIMENSIONS N FIELD EXISTING PORTIONS OF BUILUINr ,.� "'I'- C". �t WITH THE PROVISIONS OF EXISTING OCCUrAiJ`.',IS" AS SET FORTH IN THE FLORIDA FIRE PREVENTION C=i, Notes: Revisions: 1 8 -15 -05 PLAN REVISION 8 -22 -05 PLAN REVISION S -IS -05 PLAN REVISION ,t L Al onsulta I 1 E L E M E N T S ARCHITECTS - INTERIOR DESIGNERS Tampa Office The Edgewater Building 600 South Magnolia Avenue Suite 150 Tampa, Florida 33606 Phone 813" 5: -0565 Fax 8135 -25!-0567--- Miami- Offic ;a 4240 Southwest- 3rd - Street Miami, Flcrid? 33134 Phone -441 -7517 Fax �0 774-1-12S, Nicholas Puglisi Architect - LiceniW #M124 0 ELEMENTS State License #AA0002341 W'kCHOVIA - = - WEST eAKES BRANCH 5880 BIRD ROAD MIAMI, FLORIDA Drawing No. /Date 8/1/05 A-3.2 04 -028 Drawing Title /Scale /Drawn by BDL SECOND FLOOR PLAN SCALE.- AS NOTED