Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-1471(2)-030
PANEL SCHEDULE PANEL: A LOCATION: ELECTRIC ROOM 105 VOLTS: 208Y/120 PHASE: 3WIRE: 4 HERTZ: 60 M. BREAKER: 100 MAIN AIC: 42,000 BR.AIC: 42,000 ENCL: NEMA 1 MTG.: SURFACE 100 AMP, GROUND BAR DESCRIP. OF LOAD SERVED BRANCH PANEL SCHEDULE BREAKER VA PHASE VA PHASE CKT NO. CKT NO. CKT NO. VA PHASE PANEL: B BREAKER BRANCH BRANCH DESCRIP. OF LOAD SERVED W C A P A B C A B C A P W C LTG 12 * 20 1 1626 2400 8,976 1 2 1730 SIZE FEEDER TO SECTION II) 13,550 20 1 12 * EGRESS LTG. LTG 12 * 20 1 1 1536 2400 3 4 11,200 288 2496 20 1 12 * STAIR LTG. LTG 12 * 20 1 1 VA PHASE 1248 5 6 PHASE BREAKER 288 20 1 12 * STAIR LTG. LTG 12 * 20 1 1152 NO. A 7 8 521 P W 20 1 12 * ELEV. PIT LTG. VAULT LTG 12 * 20 1 1 600 2 9 10 10 52 1000 20 1 12 * ELEV. CAB LTG. ACCENT LTG 12 * 20 1 1 1 300 11 12 1 4 300 20 1 12 * NEW EXT. LTG. EXIST SITE LTS 12 * 20 1 1200 12 * 13 14 1 160 12,332 20 1 6 * SPARE EXIST SITE LTS 12 * 20 1 13 1200 * 15 16 12 * 20 20 1 1200 * ISPARE EXIST SITE LTS 12 * 20 1 20 -- 1600 17 18 18 ICOUNTER TOP RM 122 20 1 * 20 SPARE EXIST SITE LTS 12 * 20 1 1600 3 1500 19 20 1,200 1 15,896 20 1 IREC RMS 111,112,113 SPARE EXIST SITE LTS 12 * 20 1 1 1600 50 21 22 22 830 830 20 1 1 * SPARE EXIST FLOOR LT 12 * 20 1 * 20 570 23 24 24 24 13 20 1 12 * SPARE SPARE 1 * 20 1 * COUNTER TOP RM 109 DYE PACK 25 26 20 26 1 20 1 12 15 SPARE SPARE 830 * 20 1 1 830 12 27 28 WTR COOLER 1ST FL. DYE PACK 12 20 1 12 1 SPARE SPARE 360 17 20 1 1 830 20 29 30 30 12 830 20 1 DYE PACK 12 SPARE SPARE 12 1 20 1 1,000 19 20 31 32 800 20 20 1 12 * SPARE SPARE DYE PACK 12 20 1 1 1 33 34 21 22 20 1 20 * SPARE SPARE 12 * 20 1 REC OFF 104 12 * 35 36 1 36 1 20 1 24 SPARE SPARE 20 * 20 1 12 * 37 38 12 * 20 20 1 60 3 SPARE SPARE 26 1000 20 1 20 1,000 1 39 40 40 * REC CB 103 -104 20 1 * 20 SPARE SPARE SPARE 1200 20 1 28 860 41 42 42 1 20 1 * REC TELLER CAB. SPARE TOTAL VA PHASE 5578 4936 37181 17821_ 3401 588 TOTAL VA PHASE NOTES: 1. AIC RATINGS ARE MINIMUM SYMMETRICAL AMOUNTS 2. * INDICATES: SIZED TO NEC 3. CONNECTED KVA = 16.942 4. DEMAND KVA = 16.942 PANEL SCHEDULE PANEL: AA LOCATION: ELECTRIC CLOSET 205 VOLTS: 20W120 PHASE: 3WIRE: 4 HERTZ: 60 M. BREAKER:100 MAIN AIC: 42,000 BR.AIC: 42,000 ENCL: NEMA 1 MTG.: SURFACE 100 AMP, GROUND BAR DESCRIP. OF LOAD SERVED BRANCH PANEL SCHEDULE BREAKER VA PHASE VA PHASE CKT NO. CKT NO. CKT NO. VA PHASE PANEL: B BREAKER BRANCH BRANCH DESCRIP. OF LOAD SERVED W F C A P A B C A B C A P W C 2ND FL CORR LTG 12 * 20 1 630 2400 8,976 1 2 1000 SIZE FEEDER TO SECTION II) 13,550 20 1 12 * 2ND FL EGRESS LT RM 215 LTS. 12 * 20 1 1 1440 2400 3 4 11,200 990 2496 20 1 12 * RM 216 LTS. RM 217 LTS. 12 * 20 1 1 VA PHASE 1350 5 6 PHASE BREAKER 1000 20 1 12 * RM 218 LTS. RM 219 LTS. 12 * 20 1 1200 NO. A 7 8 990 P W 20 1 12 12ND FL LTGS. RM 204 LTS. 12 * 20 1 1 800 2 9 10 10 20 1000 20 1 12 * SPARE SPARE REC. TELLER LINE 12 20 1 1 1 1,200 11 12 1 4 1,200 20 1 20 * SPARE SPARE 12 * 20 1 REC. TELLER LINE 12 * 13 14 1 160 12,332 20 1 6 * SPARE SPARE 20 * 20 1 13 1,200 * 15 16 12 * 20 20 1 1200 * SPARE SPARE 8 360 20 1 20 -- 1 17 18 18 ICOUNTER TOP RM 122 20 1 * 20 SPARE SPARE 12 601 20 1 10 3 1500 19 20 1,200 1 15,896 20 1 IREC RMS 111,112,113 ISPARE SPARE * 20 20 1 1 1 50 21 22 22 830 830 20 1 1 * ISPARE SPARE * REF. RM 107 20 1 * 20 1,500 23 24 24 24 13 20 1 12 * 1 SPARE SPARE 1 * 20 1 * COUNTER TOP RM 109 DYE PACK 25 26 20 26 1 20 1 12 15 ISPARE SPARE 830 * 20 1 1 830 12 27 28 WTR COOLER 1ST FL. DYE PACK 12 20 1 12 1 SPARE SPARE 360 17 20 1 1 830 20 29 30 30 12 830 20 1 DYE PACK 12 SPARE SPARE 12 1 20 1 1,000 19 20 31 32 800 20 20 1 12 * SPARE SPARE DYE PACK 12 20 1 1 1 33 34 21 22 20 1 20 * SPARE SPARE 12 * 20 1 REC OFF 104 12 * 35 36 1 36 1 20 1 24 SPARE SPARE 20 * 20 1 12 * 37 38 12 * 20 20 1 60 3 SPARE SPARE 26 1000 20 1 20 1,000 1 39 40 40 * REC CB 103 -104 20 1 * 20 SPARE SPARE SPARE 1200 20 1 28 860 41 42 42 1 20 1 * REC TELLER CAB. SPARE TOTAL VA PHASE 18301 2240 1350 1 19901 990 1000 TOTAL VA PHASE NOTES: 1. AIC RATINGS ARE MINIMUM SYMMETRICAL AMOUNTS 2. * INDICATES: SIZED TO NEC 3. CONNECTED KVA = 9.400 4. DEMAND KVA = 9.400 PANEL SCHEDULE PANEL: BA LOCATION: ELECTRIC CLOSET 205 VOLTS: 208Y 120 PHASE: 3WIRE: 4 HERTZ: 60 M. BREAKER: 225 MAIN AIC: 42,000 BR.AIC: 42,000 ENCL. NEMA: 1 MTG.: SURFACE 225 AMP, GROUND BAR DESCRIP. OF LOAD SERVED BRANCH PANEL SCHEDULE BREAKER VA PHASE VA PHASE CKT NO. CKT NO. VA PHASE VA PHASE PANEL: B LOCATION: ELECTRIC CLOSET 205 BRANCH VOLTS: 120/208V W PHASE: 3WIRE: 4 P HERTZ: 60 C M. BREAKER:225 MAIN AIC:42,000 C A BR.AIC:42,000 W ENCL: NEMA 1 MTG.: SURFACE 1 1,200 2400 8,976 SECTION I OF II (PROVIDE FEED THROUGH LUGS AND FULL SIZE FEEDER TO SECTION II) 13,550 20 1 12 * REC RM 216 REC RM 217 12 * 225 AMP, GROUND BAR 1 1 1,200 2400 3 4 11,200 4 2496 20 1 12 * REC RM 216 REC RM 217 12 DESCRIP. OF BRANCH BREAKER 1 VA PHASE CKT CKT VA PHASE BREAKER 1,200 BRANCH 1 DESCRIP. OF LOAD SERVED W C A P A B C NO. NO. A B C A P W C LOAD SERVED REC. ELEV. PIT 12 * 20 12 1 1500 1 1 1 2 1200 10 10 20 1000 1 1 12 * * REC OFF 123 -124 REC. TELLER LINE 12 * 20 1 1 1,200 540 12 3 4 1,200 60 1 20 * 1 REC RM 215 12 * * REC OFF 125 REC. TELLER LINE 12 * 20 14 1 160 12,332 540 5 6 * REC RM 216 1500 20 * 1 1 13 1,200 * REC COPIER RM 122 REC OFF 118 -119 12 * 20 20 1 1200 * REC RM 215 7 8 360 20 1 20 -- 1 17 12 18 ICOUNTER TOP RM 122 REC OFF 117 12 * 20 REC RM 215 1 12 601 20 9 10 3 1500 19 20 1,200 1 15,896 12 1 IREC RMS 111,112,113 REC TV RM 109 12 * 20 20 1 1 1 50 11 12 22 830 830 20 1 1 * 12 MICROWAVE RM 204 * REF. RM 107 VENDING RM 107 12 * 20 1,500 1 830 24 24 13 14 1500 12 * 20 REC COUNTER TOP 1 * 12 1 * COUNTER TOP RM 109 DYE PACK 12 * 20 26 1 20 360 12 15 16 REF. 12 RM 204 830 * 20 1 1 830 12 27 * WTR COOLER 1ST FL. DYE PACK 12 * 20 12 1 VEND MACH RM 204 GEN. CLEAN. 2ND FL 360 17 18 1 1 830 20 29 1 30 12 830 * WTR COOLER 1ST FL. DYE PACK 12 * 20 1 12 1 360 1 1,000 19 20 360 32 800 20 1 1 12 * * TELLER MONITOR DYE PACK 12 * 20 1 1 360 34 21 22 360 1 20 * 1 SEC. EQUIP. 12 * * TELLER LINE TV REC OFF 104 12 * 20 36 1 36 1 60 23 24 SPARE 1500 20 * 1 1 12 * COPIER RM 104 REC F.C.M. 12 * 20 20 1 60 3 ISPARE 25 26 1000 1 1 20 1,000 1 39 12 1 40 * REC CB 103 -104 REC. GEN. CLEAN. 12 * 20 SPARE 1 SPARE 1200 20 27 28 860 41 20 42 1 12 1 * REC TELLER CAB. DRIVE THRU UNIT CON 12 * 20 1 20 29 30 540 20 1 12 IREC D CAB. VCR ATM 12 * 20 1 1000 31 32 180 20 1 12 IREC DRIVE THRU REC DRIVE THRU 12 * 20 1 3601 33 34 180 20 1 1 12 IREC DRIVE THRU REC DRIVE THRU 12 * 20 1 1 360 35 36 1080 20 1 1 12 * RECD TELLER WT RM FACP -1 12 * 20 1 1000 37 38 1000 20 1 12 * DATA RACK UPS 8 * 40 2 2500 39 40 10001 20 1 12 * DATA RACK 2500 41 42 1 1000 20 1 12 * REC TELLER SECTION II OF II FED FROM SECTION 1 225 AMP, GROUND BAR DESCRIP. OF BRANCH BREAKER VA PHASE CKT CKT VA PHASE BREAKER BRANCH DESCRIP. OF LOAD SERVED W C A P A B C NO. NO. A B C A P W C LOAD SERVED FACP -2 12 * 20 1 1000 43 44 20 1 SPARE FACP -3 12 * 20 1 10001 45 46 20 1 SPARE FACP -4 12 * 20 1 1000 47 48 20 1 SPARE FACP -5 12 * 20 1 1000 49 50 20 1 SPARE SPARE 20 1 51 52 20 1 SPARE SPARE 20 1 53 54 20 1 SPARE SPARE 20 1 55 56 20 1 SPARE SPARE 20 1 57 58 20 1 SPARE SPARE 20 1 59 60 20 1 SPARE SPARE 20 1 61 62 20 1 SPARE SPARE 20 1 63 64 20 1 SPARE SPARE 20 1 65 66 20 1 1 ISPARE SPARE 20 1 67 68 20 1 SPARE SPARE 20 1 69 70 20 1 SPARE SPARE 20 1 71 72 20 1 SPARE SPARE 20 1 73 74 20 1 SPARE SPARE 20 1 75 76 20 1 SPARE SPARE 20 1 77 78 20 1 SPARE SPARE 20 1 79 80 20 1 SPARE SPARE 20 1 81 82 20 1 SPARE SPARE 20 1 83 84 20 1 SPARE TOTAL VA PHASE 79501 63801 4890 5600 4790 7280 TOTAL VA PHASE NOTES: 1. AIC RATINGS ARE MINIMUM SYMMETRICAL AMOUNTS 2. * INDICATES: SIZED TO NEC 3. CONNECTED KVA = 36.890 4. DEMAND KVA = 36.890 PANEL SCHEDULE PANEL: BA LOCATION: ELECTRIC CLOSET 205 VOLTS: 208Y 120 PHASE: 3WIRE: 4 HERTZ: 60 M. BREAKER: 225 MAIN AIC: 42,000 BR.AIC: 42,000 ENCL. NEMA: 1 MTG.: SURFACE 225 AMP, GROUND BAR DESCRIP. OF LOAD SERVED BRANCH BREAKER BREAKER VA PHASE VA PHASE CKT NO. CKT NO. VA PHASE VA PHASE BREAKER BREAKER BRANCH BRANCH DESCRIP. OF LOAD SERVED W C A P A B C A I B C A P W C REC RM 217 12 * 20 1 1,200 2400 8,976 1 2 1,2001 2496 13,550 20 1 12 * REC RM 216 REC RM 217 12 * 20 1 1 1,200 2400 3 4 11,200 4 2496 20 1 12 * REC RM 216 REC RM 217 12 * 20 1 1 1,200 5 6 6 6 1,200 20 1 12 * REC RM 216 REC RM 217 12 * 20 1 1.200 2400 7,360 7 8 1,200 2496 14,400 20 1 12 * REC RM 216 REC RM 217 12 * 20 1 1 1,200 2400 9 10 10 1,200 1000 20 1 12 * REC RM 216 REC RM 215 12 * 20 1 1 1,200 11 12 12 12 1,200 20 1 12 * REC RM 216 REC RM 215 12 * 20 1 1,200 2250 3,820 13 14 1,200 160 12,332 20 1 12 * REC RM 216 REC RM 215 12 * 20 1 -- 1,200 2250 15 16 16 1,200 160 20 1 12 * REC RM 215 REC RM 215 12 * 20 1 1 -- 1,200 17 18 18 18 1,2001 20 1 12 * REC RM 215 REC RM 215 12 * 20 1 1,200 3 16,904 19 20 1,200 130 15,896 20 1 12 * REC RM 215 REC RM 215 12 * 20 1 1 1,200 21 22 22 830 1000 20 1 12 * REC WATER COOLER MICROWAVE RM 204 12 * 20 1 1 -- 1,500 23 24 24 24 830 20 1 12 * REC WATER COOLER REC COUNTER TOP 12 * 20 1 1,500 3 16,904 25 26 500 26 20 1 12 * REC RV REC RM 204 REF. 12 RM 204 12 * 20 1 1 830 27 28 28 830 20 1 12 * VEND MACH RM 204 GEN. CLEAN. 2ND FL 12 * 20 1 1 -- 1,200 29 30 30 30 830 20 1 12 * VEND MACH RM 204 REC RM 212 -213 12 * 20 1 1,000 3 31 32 800 32 20 1 12 * CORR 2ND FL REC OFF 210 12 * 20 1 1 600 33 34 34 1,500 20 1 12 * REC MTB SEC. EQUIP. 12 * 20 1 1 -- 1,000 35 36 36 36 1 20 1 1 SPARE SEC. EQUIP. 12 * 20 1 1,000 37 38 38 38 20 1 1 3 ISPARE SEC. EQUIP. 12 * 20 1 1 1,000 39 40 40 40 20 1 1 1 -- SPARE SPARE SPARE SPACE 20 1 1 1 41 42 42 42 20 1 1 -- SPARE TOTAL VA PHASE 8,300 7.2301 7,300 6,100 6,760 5,260 TOTAL VA PHASE NOTES: 1. AIC RATINGS ARE MINIMUM SYMMETRICAL AMOUNTS 2. * INDICATES: SIZED TO NEC 3. CONNECTED KVA = 40.950 4. DEMAND KVA = 40.950 PANEL SCHEDULE PANEL: C LOCATION: ELECTRIC ROOM 105 VOLTS: 208Y 120 PHASE: 3WIRE: 4 HERTZ: 60 M. BREAKER: 225 MAIN AIC: 42,000 BR.AIC: 42,000 ENCL:- NEMA 1 MTG.: SURFACE 225 AMP, GROUND BAR DESCRIP. OF LOAD SERVED BRANCH BREAKER VA PHASE CKT NO. CKT NO. VA PHASE BREAKER BRANCH DESCRIP. OF LOAD SERVED W C A P A B C A B C A P W C D UNIT 10 * 30 1 2400 8,976 1 2 2496 13,550 30 2 10 * CU D UNIT 10 * 30 1 -- 2400 8,976 3 4 4 2496 11,170 -- -- -- -- - -- Dia UNIT 10 * 30 1 2400 5 6 6 24961 30 2 10 * AHU D T UNIT 10 * 30 1 2400 7,360 7 8 2496 14,400 1 -- -- -- -- - -- D UNIT 10 * 30 1 -- 2400 5,2761 9 10 10 1000 13,990 20 1 10 * IRR. PUMP UNIT MTD. REC. 12 * 20 1 1000 11 12 12 830 20 1 12 * EF -1 WATER HEATER 10 * 30 2 2250 3,820 13 14 160 12,332 20 1 12 * EF -2 PANEL C - -- -- -- -- -- 2250 3,230 15 16 16 160 11,706 20 1 12 * EF -3 EF -6 --- * 20 1 -- 160 17 18 18 280 20 1 12 * EF -4 SPARE RTU -1 HACR 2 0 20 1 3 16,904 19 20 130 15,896 20 1 12 * EF -5 SPARE - -- -- 20 1 -- 16,904 21 22 22 1000 15,896 20 1 10 * VAV BX. 2ND FL. SPARE --- -- 20 1 -- 23 24 24 1000 20 1 10 * VAV BX. 1ST FL. SPARE RTU -2 HACR 2/0 20 1 3 16,904 25 26 26 20 1 SPARE SPARE - -- -- 20 1 -- 16,904 27 28 28 20 1 SPARE SPARE - -- -- 20 1 -- 29 30 30 20 1 SPARE SPARE SPARE 20 1 3 31 32 32 20 1 SPARE SPARE -- -- 20 1 -- _ 33 34 34 20 1 SPARE SPARE - -- -- 20 1 -- 35 36 36 20 1 SPARE SPARE SPACE 20 1 37 38 38 20 1 3 -- SPARE SPARE SPACE 0 1 39 40 40 20 1 -- -- SPARE SPARE SPACE 0 1 41 42 42 20 1 -- -- SPARE T 7050 7050 3560 5282 4656 4606 TOTAL VA PHASE NOTES: 1. AIC RATINGS ARE MINIMUM SYMMETRICAL AMOUNTS 2. * INDICATES: SIZED TO NEC 3. CONNECTED KVA = 32.204 4. DEMAND KVA = 32.204 PANEL SCHEDULE PANEL: MDP LOCATION: ELECTRIC ROOM 105 VOLTS: 208Y 120 PHASE: 3 WIRE: 4 HERTZ: 60 M. BREAKER: 1,200 MAIN AIC: 42,000 BR.AIC: 42,000 ENCL: NEMA 1 MTG.: SURFACE 1,200 AMP, GROUND BAR DESCRIP. OF LOAD SERVED BRANCH BREAKER VA/ PHASE CKT NO. CKT NO. VA PHASE BREAKER BRANCH DESCRIP. OF W C A P A B C A B C A P W C LOAD SERVED ELEVATOR 3/0 * 200 3 8,976 1 2 13,550 200 3 3 0 * PANEL B - -- -- -- -- -- 8,976 3 4 11,170 -- -- -- -- - -- -- 8,976 5 6 12,170 -- -- -- -- - -- PANEL A 1 * 100 3 7,360 7 8 14,400 150 3 1/0 * PANEL BA - -- -- -- -- -- 5,2761 9 10 13,990 -- -- -- -- - -- 4,306 11 12 12,560 -- -- -- -- - -- PANEL AA 1 * 100 3 3,820 13 14 12,332 150 3 1 0 * PANEL C - -- -- -- -- -- 3,230 15 16 11,706 -- -- -- -- - -- --- -- -- -- -- 2,350 17 18 8,166 -- -- -- -- - -- RTU -1 HACR 2 0 * 175 3 16,904 19 20 15,896 175 3 2 0 * RTU -3 HACR - -- -- -- -- -- 16,904 21 22 15,896 -- -- -- -- - -- --- -- -- -- -- 16,904 23 24 15,896 -- -- -- -- - -- RTU -2 HACR 2/0 * 175 3 16,904 25 26 SPACE - -- -- -- -- -- 16,904 27 28 SPACE - -- -- -- -- -- 16,904 29 30 SPACE SPARE 100 3 31 32 SPACE -- -- -- -- -- _ 33 34 SPACE - -- -- -- -- -- 35 36 SPACE SPACE 37 38 30 3 -- -- TVSS SPACE 39 40 -- -- -- -- - -- SPACE 41 42 -- -- -- -- - -- TOTAL VA PHASE 53,964 51,290 49,440 56,1781 52.7621 48,7921 TOTAL VA PHASE NOTES: 1. AIC RATINGS ARE MINIMUM SYMMETRICAL AMOUNTS 2. * INDICATES: SIZED TO NEC 3. CONNECTED KVA = 312.426 4. DEMAND KVA = 312.426 f�lc�t�s: Ke,.'isiOns' _Onsl_Iltants: 0 ARCHITECTURAL ENGINEERING INCORPORATED 3442 EAST LAKE ROAD, PALM HARBOR, FL 34685 CONSULTING ENGINEERS (727) 784 -1472 CERTIFICATE OF AUTHORIZATION: FL 3886 W. RONALD MCILVEEN FL PE 30270 1 MENU 00 let JIM at E L E M--E H-T--S �..� ARCHITECT -INTERIOR T(:::i r7-)p ffic6�- T h� Ecl <_l�`. ^�r�Ite�, Buil� °iin ' -,00 5c'util -- it° I M T rnpci, r inricln 3300u Phone ( °"1 -3) 251-05-65- 1. /1 i rD 17 �D f f_ 4240 S,: Itllva?st .3rr! ',treet 1%11 :iml, FI,_,rida 331.',4 Phone (",05) 441-7617 (=a. (li05) 77.1 -I I_3 Nich,�las Puglisi Architect License ELEMENTS Stot, b,:ense ?AA000'S�1 WACHOVIA WEST GABLES BRANCH ���0 BIRD RO.�D MI.�r�Tl, rLOR ID,� Drav�ing No ;'Date 512/05 E0.2 Dro%v'i g Title !Sc _ilei Drcnvr I_d � /D ELECTRICAL SCHEDULES A BA �G,�I AA C B MDP -