05-1471(2)-029
GENERAL NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NA11ONAL ELECTRICAL CODE AND ALL LOCAL CODES HAVING JURISDICTION. 2. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF HIS WORK. 3. CONTRACTOR SHALL VISIT THE SITE AND EXAMINE CONDITIONS OF THE PREMISES AND THE CHARACTER AND EXTENT OF WORK REQUIRED PRIOR TO SUBMISSION OF BIDS. ANY DIFFICULTIES IN COMPLYING WITH THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER BEFORE BIDDING. 4. IT IS THE INTENT OF THESE DRAWINGS AND OTHER RELATED DOCUMENTS TO PRODUCE A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL AND OTHER SERVICES AS MAY BE NECESSARY TO ACHIEVE THIS PRODUCT. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY DISCREPANCIES IN THE PLANS AND SPECIFICATIONS THAT WILL AFFECT THE WORK, PRIOR TO SUBMISSION OF HIS BID PRICE. 5. IF, DURING THE COURSE OF THE WORK, THE CONTRACTOR EXPER- IENCES A PROBLEM WITH THE PERFORMANCE OF THE INSTALLATION RELATIVE TO THE PLANS AND SPECIFICATIONS, THE NATIONAL ELEC- TRICAL CODE, OTHER APPLICABLE CODES AND GOVERNING DOCUMENTS, THE CONTRACTOR SHALL BRING THE PROBLEM TO THE ATTENTION OF THE ARCHITECT AND /OR THE ENGINEER FOR RESOLUTION PRIOR TO EXECUTION OF THE WORK. 6. ALL MATERIAL SHALL BE NEW AND BEAR THE U.L. LABEL LISTED APPROVAL FOR ITS INSTALLED APPLICATION. 7. ALL MAJOR COMPONENTS OF THE ELECTRICAL SYSTEMS SUCH AS SAFETY DISCONNECT SWITCHES, AND PANELBOARDS SHALL BE BY THE SAME MANUFACTURER AND SHALL BE ONE OF THE FOLLOWING: SQUARE "D" COMPANY, GENERAL ELECTRIC, OR CUTLER- HAMMER. 8. CIRCUIT BREAKERS USED FOR SWITCHING OF LIGHTING OR SIGN CIRCUITS SHALL BE APPROVED FOR SWITCHING DUTY AND SHALL BE MARKED "SWD" IN ACCORDANCE WITH N.E.C. ART. 240.83 (D). 9. PROVIDE "LOCKING" TYPE DEVICES ON ALL CIRCUIT BREAKERS CONNECTED TO EMERGENCY AND NIGHT LIGHTING, SIGNS, FIRE ALARM, SECURITY SYSTEMS, AFTER HOUR DEPOSIT AND AUTOMATIC TELLER MACHINES. 10. ALL SWITCHES, DUPLEX RECEPTACLES, AND TELEPHONE OUTLETS TO BE FLUSH MOUNTED, THROUGHOUT. 11. ALL SERVICE EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. ARTICLE 250. 12. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCATIONS OF HVAC EQUIPMENT. 13. SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT FIXTURES. 14. ELECTRICAL PLANS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS. 15. CONSULT PLANS OF ALL OTHER TRADES FOR COORDINATION AND FOR RELATED AND ADJOINING WORK. 16. CONSULT ARCHITECTURAL AND STRUCTURAL PLANS AND DETAILS FOR CONSTRUCTION TYPE, HEADROOM, ROOM FINISHES, CEILINGS, ETC. 17. ALL WORK SHALL BE DONE AT SUCH TIMES AND IN SUCH A MANNER AS WILL LEAST INTERFERE WITH THE MAINTENANCE AND OPERATION OF ALL RELATED OR AFFECTE=D SYSTEMS. ALL POWER OUTAGES SHALL BE COORDINATED WITH OWNER. 18. THE CORRECT NUMBER OF WIRES MAY NOT BE INDICATED FOR ALL CIRCUITS, ONLY THOSE WHERE CLARIFICATION IS NECESSARY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRES NECESSARY FOR THE PROPER FUNCTION OF THE SYSTEM. 19. ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FT. SHALL BE PROVIDED WITH A PULL WIRE OR FISH TAPE /CORD. 20. ALL BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL BE INCREASED TO THE NEXT LARGER SIZE WHERE THE LENGTH OF THE HOME RUN EXCEEDS 100 FT. ON 120/208V CIRCUITS. 21. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER SIZING OF ALL MOTOR OVERLOAD DEVICES (HEATERS) IN STARTERS BASED ON ACTUAL NAMEPLATE RATINGS ON THE MOTORS BEING INSTALLED. 22. CONTRACTOR SHALL NOTE U.L. LABELS ON PACKAGE TYPE MECHANICAL EQUIPMENT. IF U.L. LABEL ON MECHANICAL EQUIPMENT CALLS FOR THE OVERCURRENT PROTECTIVE DEVICE TO BE FUSES, THE ELECTRICAL CON- TRACTOR SHALL PROVIDE A FUSED DISCONNECT SWITCH WITH PROPER SIZE FUSES AT THE SWITCH LOCATION INDICATED ON DRAWINGS. 23• CONTRACTOR SHALL VERIFY WIRE SIZES, C/B AND FUSE RATINGS FOR ALL HVAC EQUIPMENT, AND BRING TO THE ATTENTION OF THE ARCHITECT AND /OR THE ENGINEER ANY DISCREPANIES AFFECTING THE WORK PRIOR TO PROCEEDING. 24. HORSEPOWER RATINGS INDICATED ON DRAWING MAY DIFFER FROM ACTUAL EQUIPMENT FURNISHED. IF FURNISHED EQUIPMENT DIFFERS FROM RATINGS ON DRAWINGS, CONTRACTOR SHALL NOTIFY ARCHITECT AND /OR THE ENGINEER FOR APPROPRIATE ACT10N TO BE TAKEN. 25. PROVIDE APPROVED "HACR" TYPE CIRCUIT BREAKERS FOR ALL HEATING, AIR CONDITIONING, AND REFRIGERATION EQUIPMENT INDICATED FOR CONNECTION ON ELECTRICAL DRAWINGS. 26. ALL DEVICES AND COVERPLATES SHALL BE CONSTRUCTED OF MOLDED NYLON MATERIALS. COLOR OF DEVICES AND MATCHING COVERPLATES SHALL BE AS SELECTED BY THE ARCHITECT. 27. THE CONTRACTOR SHALL GUARANTEE ALL HIS WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 28. IT SHALL BE THE RESPONSIBLITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE SERVICE REQUIREMENTS FOR POWER AND TELEPHONE UTILITIES. 29. PROVIDE A #10 NEUTRAL CONDUCTOR FOR ALL MULTIWIRE RECEPTACLE BRANCH CIRCUITS. 30. FOR ALL EQUIPMENT RATED 100AMPS OR LESS, E.C. SHALL PROVIDE TERMINATIONS WHICH ARE LISTED FOR USE AT 75'C OR PROVIDE WIRING SIZED USING THE 60'C AMPACITY. 31. RECEPTACLES ON SEPARATE CIRCUITS SHALL BE RATED 20 AMP, 120 VOLT. 32, WIRE AND CABLE SHALL BE COPPER, TYPE THHN /THWN, MINIMUM #12 AWG. 33. PANELBOARD DIRECTORIES SHALL BE UPDATED TO REFLECT ALL WORK DONE AS PART OF THIS PROJECT. 34. ALL NEW BRANCH CIRCUITS SHALL BE EQUIPPED WITH A MINIMUM #12 AWG GREEN EQUIPMENT GROUND CONDUCTOR. 35. CONDUIT RUN UNDERGROUND SHALL BE PVC SCHEDULE 40. ALL BUILDING WIRING SHALL BE RUN IN METALLIC CONDUIT. INTERIOR CONDUIT SHALL BE EMT. EXTERIOR CONDUIT SHALL BE IMC OR RMC. 36. FOR IG RECEPTACLES, PROVIDE 2 #12 GREEN GROUND WIRES IN BRANCH CIRCUIT BACK TO PANELBOARD. LIGHTING FIXTURE SCHEDULE RECESSED FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. O DARKENED HALF IN ANY LIGHTING FIXTURE SYMBOL SHOWN , HEREIN INDICATES THAT FIXTURE SHALL CONTAIN ASELF- CONTAINED BATTERY PACK NL i O TOTAL CONTAINED BATTERY PACK AND INVERTER TYPE DESCRIPTION N0. /LAMPS MANUFACTURER CATALOG NUMBER BALLAST TYPE FIXTURE VOLTS REMARKS THAT FIXTURE IS ON UNSWITCHED NIGHT LIGHTING SYSTEM, W /SELF- CONTAINED BATTERY PACK AND INVERTER ® CEILING MOUNTED EXIT LIGHT. SINGLE FACE, BLACKENED AREA REPRESENTS FACE. VA �Q GROUND MOUNTED H.I.D TYPE FLOOD LIGHT FIXTURE. LETTER INDICATES TYPE. �--o- -� SURFACE FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. S SINGLE POLE SWITCH IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, UNLESS HEIGHT IS OTHERWISE NOTED ON PLAN. S3 THREE -WAY SWITCH IN OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR. RECESSED DIRECT /INDIRECT OA 2' X 4' LAY -IN 3 -F32T8 METALUX 2RD1332RP120 -EB81 ELECTRONIC 96 120 FLUORESCENT WITH CENTER 18" ABOVE FINISHED FLOOR. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DOUBLE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE DESK /COUNTERTOP, OR 2 INCHES ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 48 INCHES BASKET ABOVE FINISHED FLOOR, 6 INCHES ABOVE DESK /COUNTERTOP, OR 2 INCHES ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE WITH STAINLESS STEEL WEATHERPROOF COVER, 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. SAME AS TYPE 'A' EXCEPT Al 2' X 4' LAY -IN 3 -F32T8 METALUX 2RD1332RP1 20-EB81 -EL4 ELECTRONIC 96 120 FIXTURE TO BE PROVIDED WITH SELF - CONTAINED EMERGENCY NEMA 5 -30R I-(® SPECIAL OUTLET AS NOTED ON THE PLANS. PROVIDE NEW WALKER RFB4 SERIES CAST IRON FLOOR BOX, FOR CONCRETE ON GRADE, WITH S36BBT -CAL COVER PLATE. COORDINATE COLOR WITH OWNER. PROVIDE WITH TWO DUPLEX BATTERY INVERTER RATED FOR OR AS INDICATED ON DRAWINGS. FLUSH OUTLET BOX FOR WALL - MOUNTED TELEPHONE 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE COUNTERTOP, OR AT HEIGHT INDICATED ON PLAN, WITH 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. 1 1/2 HOUR BACKUP PER NFPA -101 TELEPHONE /DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER WITH (1) 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. DEVICE TO BE 18" AFF OR AS NOTED. d TELEPHONE /DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER WITH (1) 3/4" ELECTRONIC CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. DEVICE TO BE 48" AFF, 6" ABOVE SAME AS TYPE 'A' EXCEPT A2 2' X V LAY -IN 3 -F32T8 METALUX 2RD1332RP120 -EB82 2 -LAMP 96 120 WITH INBOARD - OUTBOARD SWITCHING PHOTOELECTRIC CELL. MOUNT 10' -6" AFF TO TOP. © MECHANICALLY HELD LIGHTING CONTACTOR. T� TIME CLOCK. 1 -LAMP NON- FUSIBLE DISCONNECT SWITCH IN NEMA -1 ENCLOSURE. SUBSCRIPT NUMERAL INDICATES SWITCH RATING IN AMPERES. 30 PROVIDE NUMBER OF POLES AS REQUIRED, VOLTAGE RATING AS REQUIRED. 3R INDICATES NEMA -3R ENCLOSURE. FUSED DISCONNECT SWITCH IN NEMA -1 ENCLOSURE. SUBSCRIPT NUMERAL INDICATES 30 �3R SWITCH RATING IN AMPERES. PROVIDE NUMBER OF POLES AS REQUIRED, VOLTAGE AS REQUIRED. 3R INDICATES NEMA -313 ENCLOSURE. FUSE SIZE AS INDICATED. PROVIDE Al2.125 PRISMATIC ACRYLIC OB 2' X 4' LAY -IN 3 -F32T8 METALUX 2GC332A125- 120 -EB82 ELECTRONIC 96 120 LENS MTD. IN A FLUSH STEEL DOOR �D DUCT MOUNTED SMOKE DETECTOR O SECURITY SYSTEM OUTLET. NUMERAL IDENTIFIES OUTLET. SEE SECURITY SYSTEM 2 -LAMP E.C. EMPTY CONDUIT WITH PULLCORD FRAME. INDICATES ISOLATED GROUND W.P. WEATHERPROOF MTB MAIN TELEPHONE BOARD 1 -LAMP NIGHT LIGHTING FPN FUSE PER NAMEPLATE NF 2' X 4' LAY -IN 2 -F32T8 METALUX 2GC232A125- 120 -EB81 ELECTRONIC 64 120 PROVIDE Al2.125 PRISMATIC ACRYLIC B1 LENS MTD. IN A FLUSH STEEL DOOR FRAME. SAME AS TYPE 'B' EXCEPT FIXTURE TO BE PROVIDED WITH 82 2' X 4' LAY -IN 3 -F32T8 METALUX 2GC332A125 -- 120 -EB81 -EL4 ELECTRONIC 96 120 SELF - CONTAINED EMERGENCY BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 SAME AS TYPE '81' EXCEPT FIXTURE TO BE PROVIDED WITH B3 2' X 4' LAY -IN 2 -F32T8 METALUX 2GC232A125 -- 120 -EB81 -EL4 ELECTRONIC 64 120 SELF - CONTAINED EMERGENCY BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 O RECESSED DIRECT /INDIRECT 2' X 2' LAY -IN 3 -F17T8 METALUX 2RD1217RP120 -EB81 MAGNETIC 51 120 FLUORESCENT WITH CENTER BASKET SAME AS TYPE 'C' EXCEPT C1 2' X 2' LAY -IN 3 -F17T8 METALUX 2RD1217RP1 20-EB81 -EL4 MAGNETIC 51 120 FIXTURE TO BE PROVIDED WITH SELF - CONTAINED EMERGENCY BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 0 4' STRIP 2 -F32T8 METALUX SS232120 -EB81 ELECTRONIC 64 120 4' STRIP, 2 LAMP. SURFACE MOUNTED RECESSED 2/26W ZUMTOBEL CLU8204U99 /FAC -C/ ELECTRONIC 52 120 STANDARD HOUSING, 8" DIAMETER O DOWN LIGHT SAR -C /SAT -L FACETTED REFLECTOR, CLEAR SATURN GLASS ACCESSORY, LIME STANDARD HOUSING, 7 3/8" DIAMETER 2/26W PORTFOLIO C7226 -E- 7251 -LI ELECTRONIC 52 120 ONE PIECE ALZAK REFLECTOR, WITH ORECESSED G DOWN LIGHT SPUN PARABOLIC CONTOUR SINGLE RING, MATTE ANODIZED ALUMINUM SAME AS TYPE 'G' EXCEPT FIXTURE TO BE PROVIDED WITH G1 RECESSED 2/26W PORTFOLIO C7226 -EEM- 7251 -LI ELECTRONIC 52 120 SELF - CONTAINED EMERGENCY DOWN LIGHT BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 FIXTURE SHALL HAVE FLANGE FOR RECESSED MOUNTING IN GYPSUM BOARD CEILING. DIE FORMED STEEL HOUSING, O RECESSED HID 1 -40OW LUMARK MHQP- S4 /16 /GL- 400 -208- MAGNETIC 460 208 SEMI - SPECULAR 16 CELL METAL DL -FTW 1PH ALUMINUM LOUVER WITH CLEAR HALIDE, TEMPERED GLASS OVERLAY CLEAR UL LISTED FOR DAMP LOCATION SAME AS TYPE 'H' EXCEPT H1 RECESSED HID 1 -40OW LUMARK MHQP- S4 /16 /GL- 400 -208- MAGNETIC 460 208 FIXTURE TO BE PROVIDED WITH M.H. AND DL -EM -FTW 1 PH QUARTZ RE- STRIKE SYSTEM 1 -250W QUARTZ METAL SIDES, FLUSH STEEL O 2' X 4' 4 -F32T8 METALUX 2M- 432A125- 120 -EB81 ELECTRONIC 128 120 DOOR FRAME AND Al2.125 SURFACE MOUNTED PRISMATIC ACRYLIC LENS MOUNT 8' -0 "AFF TO TOP. O REMOTE EMERGENCY 8W HALOGEN SURE -LITES 12T- 8 -DWBK - 8 12V HEAD O REMOTE EMERGENCY 37W DESIGN PLAN ITS6161022FTO - 37 12V SURFACE MOUNTED HEAD MR16 LOW VOLTAGE DOWNLIGHT FL40 WITH BLACK FINISH RECESSED WALL WASH © 7" x 4' LAY -IN 2 -F28T5 INSIGHT LR /PS5 /SA(2) /T5/28W/ ELECTRONIC 56 120 N WITH 4'/1 /W /KAB RO ATA13LE TI OPCS MTG & FACE AS INDICATED ON O EXIT LIGHT LED SURE -LITES CX717ORW NA 8 120 DRAWINGS. PROVIDE SELF CONTAINED BATTERY INVERTER RATED FOR 1 1/2 HOUR BACKUP PER NFPA -101 EM EMERGENCY LIGHTING SURE -LITES GC- 1505 -NH - 36 120 I ELECTRICAL SYMBOL LEGEND HOMERUN TO PANELBOARD. NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS. CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING. \ CONDUIT RUN CONCEALED IN OR BELOW FLOOR OR UNDERGROUND. CONDUIT RUN EXPOSED �LV LOW VOLTAGE WIRING SERVICE OR EQUIPMENT GROUND. QJ JUNCTION BOX FLUSH MOUNTED UNLESS INDICATED OTHERWISE. = PANELBOARD (SURFACE MOUNTED). ° TELEPHONE EQUIPMENT BACKBOARD, SEE TELEPHONE AND SATELLITE SCHEMATIC NOTES. O RECESSED FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. O DARKENED HALF IN ANY LIGHTING FIXTURE SYMBOL SHOWN , HEREIN INDICATES THAT FIXTURE SHALL CONTAIN ASELF- CONTAINED BATTERY PACK NL i O DARKENED HALF IN ANY LIGHTING FIXTURE WITH NL SYMBOL SHOWN HEREIN INDICATES THAT FIXTURE IS ON UNSWITCHED NIGHT LIGHTING SYSTEM, W /SELF- CONTAINED BATTERY PACK AND INVERTER CEILING MOUNTED INCANDESCENT OR FLUORESCENT OR HID FIXTURE. WALL MOUNTED FLUORESCENT OR HID FIXTURE. OA 2X2 RECESSED HID OR FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. DARKENED CIRCLE IN ANY DOWNLIGHT FIXTURE SYMBOL SHOWN HEREIN INDICATES THAT FIXTURE IS ON UNSWITCHED NIGHT LIGHTING SYSTEM, W /SELF- CONTAINED BATTERY PACK AND INVERTER ® CEILING MOUNTED EXIT LIGHT. SINGLE FACE, BLACKENED AREA REPRESENTS FACE. WALL MOUNTED EXIT LIGHT. SINGLE FACE, BLACKENED AREA REPRESENTS FACE. �Q GROUND MOUNTED H.I.D TYPE FLOOD LIGHT FIXTURE. LETTER INDICATES TYPE. �--o- -� SURFACE FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. S SINGLE POLE SWITCH IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, UNLESS HEIGHT IS OTHERWISE NOTED ON PLAN. S3 THREE -WAY SWITCH IN OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR. WALL MOUNTED TYPE MOTION DETECTOR SWITCH IN FLUSH MOUNTED OUTLET BOX, D 48" ABOVE FINISHED FLOOR. 125 -VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 18 INCHES ABOVE FINISHED FLOOR. SEE GENERAL NOTE. 31. 125 -VOLT, 15A, 3 WIRE DOUBLE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 18" ABOVE FINISHED FLOOR. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DOUBLE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE DESK /COUNTERTOP, OR 2 INCHES ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE DESK /COUNTERTOP, OR 2 INCHES ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE WITH STAINLESS STEEL WEATHERPROOF COVER, 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE GROUND FAULT INTERRUPTER TYPE DUPLEX RECEPTACLE IN GFI FLUSH OUTLET BOX, 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. 125 -VOLT, 15A, 3 WIRE ISOLATED GROUND TYPE RECEPTACLE IN FLUSH OUTLET BOX IG 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. -e 120 -VOLT, 30A, 3 WIRE GROUNDED TYPE RECEPTACLE IN FLUSH OUTLET BOX NEMA 5 -30R I-(® SPECIAL OUTLET AS NOTED ON THE PLANS. PROVIDE NEW WALKER RFB4 SERIES CAST IRON FLOOR BOX, FOR CONCRETE ON GRADE, WITH S36BBT -CAL COVER PLATE. COORDINATE COLOR WITH OWNER. PROVIDE WITH TWO DUPLEX N5 -15R OUTLETS. STUB 1 "EC FROM COMMUNICATIONS COMPARTMENTS TO ACCESSIBLE CEILING SPACE OR AS INDICATED ON DRAWINGS. FLUSH OUTLET BOX FOR WALL - MOUNTED TELEPHONE 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE COUNTERTOP, OR AT HEIGHT INDICATED ON PLAN, WITH 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. d TELEPHONE /DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER WITH (1) 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. DEVICE TO BE 18" AFF OR AS NOTED. d TELEPHONE /DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER WITH (1) 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. DEVICE TO BE 48" AFF, 6" ABOVE DESK /COUNTERTOP, OR 2" ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. TV • FLUSH OUTLET BOX AND TELEVISION COVERPLATE 48 INCHES ABOVE FINISHED FLOOR, 6 INCHES ABOVE COUNTERTOP, OR AT HEIGHT INDICATED ON PLAN, WITH 3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. OM CONNECTION TO FRACTIONAL HORSEPOWER ELECTRIC MOTOR. PE PHOTOELECTRIC CELL. MOUNT 10' -6" AFF TO TOP. © MECHANICALLY HELD LIGHTING CONTACTOR. T� TIME CLOCK. EP NON- FUSIBLE DISCONNECT SWITCH IN NEMA -1 ENCLOSURE. SUBSCRIPT NUMERAL INDICATES SWITCH RATING IN AMPERES. 30 PROVIDE NUMBER OF POLES AS REQUIRED, VOLTAGE RATING AS REQUIRED. 3R INDICATES NEMA -3R ENCLOSURE. FUSED DISCONNECT SWITCH IN NEMA -1 ENCLOSURE. SUBSCRIPT NUMERAL INDICATES 30 �3R SWITCH RATING IN AMPERES. PROVIDE NUMBER OF POLES AS REQUIRED, VOLTAGE AS REQUIRED. 3R INDICATES NEMA -313 ENCLOSURE. FUSE SIZE AS INDICATED. IF DISCONNECT FURNISHED WITH EQUIPMENT S® SURGE SUPPRESSOR • CONNECTION TO VAV BOX R C RECALL SMOKE DETECTOR �D DUCT MOUNTED SMOKE DETECTOR O SECURITY SYSTEM OUTLET. NUMERAL IDENTIFIES OUTLET. SEE SECURITY SYSTEM BOX LEGEND. E.C. EMPTY CONDUIT WITH PULLCORD IG INDICATES ISOLATED GROUND W.P. WEATHERPROOF MTB MAIN TELEPHONE BOARD NL NIGHT LIGHTING FPN FUSE PER NAMEPLATE NF NON -FUSED I�Jotes: Revisions. o (- onsultams- ARCHITECTURAL ENGINEERING INCORPORATED 3442 EAST LAKE ROAD, PALM HARBOR, FL 34685 CONSULTING ENGINEERS (727) 784 -1472 CERTIFICATE OF AUTHORIZATION: FL 3886 W. RONALD MCILVEEN FL PE 30270 1 Alb l E L E M--E- N T S CHITECT', • Nlt�li_)R Ta f The 600 - Suit� X50 Tamj_ -)c1, r �)t idal 3 _3 F,(7) ij _ Phone (t 13) .'S1 -05o5 _ FBI:. (1 15) 51 -05F I/1 f � - -�- 42Z0 od 'f_'trer_t FluI;da Phone ( 305) 441-7617 -,-1- ( 305) 774-11-3 l llch'�I'Js PLIQIiS1 Architect Lien. e ELEMEfJTS 'State Li,_ens? 4 # A0002.41 T • WEST GABLES BRANCH 31FI:1D RO, -ND Dra,,vnng No. 'Dote 5/2/05 EO.1 0 021 0 514 51 ELECTRICAL DETAILS