Loading...
05-1471(2)-026'ROPERT A5ME FLL . DTU RATI;V r &P IZEI.IEF VAI.Vt:t2 FIMV FLPWI 5n INt21Ma1 Y ABOVE 5E12VIC6 SINK A AJI2 GAr IN r9f VAVVB PIM t215GHA946 18" HIGH HEAT TRAP 110. 2 GALLON ® EXPANSION TANK I,AJION ( TW) H1, ABOVE MOP SINK OR FD FIN. FL MOUNT EWH ON 12" CONCRETE PAD. ELECTRIC WATER HEATER DIAGRAM NO SCALE S. W. 41 T H STREET t� V.J � ZM�MLL: IV 1 J Uvvn REPLACE EX. 211V 1 -V2" VTR W/4 VTR 311 V r V r S L 1 1D Y � WC FD 1D 1 31IW 41155M 211V GENERAL PLUMBING NOTES (ALL "P" DRAWINGS) I PLUMBING LEGEND Notes: P -1 REGULATORY REQUIREMENTS: PROVIDE ALL WORK TO MEET OR EXCEED MINIMUM REGULATORY REQUIREMENTS INCLUDING: EDITION FLORIDA BUILDING CODE: 2001 2ND EDITION, WITH 2003 REVISIONS FLORIDA FIRE PREVENTION CODE: 2002 EDITION (EFFECTIVE 1/1/02) NFPA 1: 2002 EDITION ADVISE THE ARCHITECT OF ANY CHANGES IN THE CONTRACT DOCUMENTS THAT MAY BE REQUIRED IN ORDER TO MEET CODE, PRIOR TO WORK (ORDERING, ROUGHING, OR INSTALLATION). P -2 COORDINATION: COORDINATE WITH OTHER WORK (INCLUDING MECHANICAL, ELECTRICAL, CIVIL /SITE, STRUCTURAL AND ARCHITECTURAL) FOR AVAILABLE SPACE, SEQUENCE OF INSTALLATION, AND INSTALLATION REQUIREMENTS, PRIOR TO COMMENCING CONSTRUCTION. ADVISE THE ARCHITECT OF ANY CHANGES IN THE CONTRACT DOCUMENTS THAT MAY BE REQUIRED FOR THE WORK TO BE PERFORMED. P -3 DEVICE LOCATIONS: REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF PLUMBING FIXTURES, PLUMBING DEVICES, AND FIXTURE INSTALLATION HEIGHTS. LOCATE ALL PIPING IN FINISHED ROOMS OR SPACES WITHIN CONCEALED LOCATIONS (FURRED CHASES OR SUSPENDED CEILINGS, AS AVAILABLE). DO NOT LOCATE PIPING ABOVE ELECTRICAL SWITCHBOARDS OR PANELBOARDS. PROVIDE METALLIC DRIP SHIELDS BELOW ALL PIPING IN COMMUNICATIONS AND ELECTRICAL ROOMS. P -4 SIZES: WHEN A PIPE SIZE IS NOT INDICATED, SIZE THAT PIPE USING THE LARGER UPSTREAM ADJACENT SIZE, UNLESS A SMALLER SIZE IS APPROVED BY THE ARCHITECT. PROVIDE 3/4 INCH MINIMUM PIPE SIZE, UNLESS SPECIFICALLY NOTED OTHERWISE. FOR SIZES NOT INDICATED ON PLANS, REFER TO EQUIPMENT DETAILS, FLOW DIAGRAMS, RISER DIAGRAMS, AND OTHER LOCATIONS IN THE CONTRACT DOCUMENTS (DRAWINGS AND SPECIFICATIONS) FOR INFORMATION. P -5 SEALS: REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF FIRE RATED PARTITIONS. SEAL ALL PENETRATIONS OF RATED PARTITIONS. P -6 TH PL INS MC JU P -7 PF IN\ FO w SL AS > cc Q EL l P -8 C( 1 AR I=- P -9 PI AC Ln P -10 PI SI CI IN P -11 PF P M B 5' CONCRETE SIDEWALK ".I_ . -R METER ,.. ,, PROVIDE NEW ISOLA11ON VALVE ON PRIVATE PROPERTY SIDE OF METER. V-4 I L II 1 D 2D FID WC 'rQ 1 1D 1V 31IV E PLUMBING INSTALLER IS ADVISED THAT THE INDICATED JMBING SYSTEM MAY NOT BE REDESIGNED BY THE PLUMBING )TALLER (NOT A CONTRACTOR DESIGNED SYSTEM), UNLESS IDIFICATIONS ARE REQUIRED BY THE AUTHORITY HAVING RISDICTION. IOR TO COMMENCING CONSTRUCTION, REVERIFY PIPE (ERTS WITH STRUCTURAL FOOTINGS AND DEPRESS OTINGS, AS REQUIRED FOR PIPE INSTALLATION. PROVIDE EEVES FOR BURIED PIPING AT WALLS AND FOUNDATIONS, REQUIRED BY THE STANDARD PLUMBING CODE. ORDINATE PIPE INVERTS AND FINISHED FLOOR EVATIONS. )ORDINATE ALL WALL CLEANOUTS (WCO) WITH CHITECTURAL CASEWORK, PRIOR TO INSTALLATION. ROVIDE ACCESS DOORS IN BUILDING CONSTRUCTION FOR :CESS TO VALVES AND TRAPS. ROVIDE OFFSETS IN ALL PIPING AT COUNTER MOUNTED NKS, AS REQUIRED (ALL OFFSETS ARE NOT SHOWN FOR ARITY). COORDINATE WITH CABINET WORK, PRIOR TO STALLATION. ;OVIDE GALVANIZED STEEL STAND -OFF BRACKET /CHANNEL TO ROVIDE 1/2 INCH (MINIMUM) AIR GAP WHEN DEVICES ARE OUNTED ON EXTERIOR WALLS (TO REDUCE MOLD /MILDEW UILDUP). WH WALL HYDRANT TYPE 1 WHA WATER HAMMER ARRESTER: PDI SIZE INDICATED B BP BACKFLOW PREVENTER TYPE: SIZE INDICATED 2 EWH ELECTRIC WATER HEATER NUMBER 1 -1 02 DRAWING NOTE: REFER TO NOTES ON EACH DRAWING AFF ABOVE FINISHED FLOOR CLG CEILING CO CLEANOUT CW COLD WATER DFU DRAINAGE FIXTURE UNITS DN DOWN DWG DRAWING EA EACH ELECT ELECTRICAL EPO EMERGENCY POWER OFF SWITCH FCO FLOOR CLEANOUT FIN FL ELEV FINISHED FLOOR ELEVATION FLA FULL LOAD AMPS FT FEET GPM GALLONS PER MINUTE HP HORSEPOWER . HVAC HEATING, VENTILATING, AND AIR CONDITIONING HW HOT WATER HWRC HOT WATER RECIRCULATING PIPING IN INCH INV INVERT " LBS POUNDS MAX MAXIMUM MCA MINIMUM CIRCUIT AMPS MIN MINIMUM MOCP MAXIMUM OVERCURRENT PROTECTION NC NORMALLY CLOSED NO NORMALLY OPEN P &T PRESSURE AND TEMPERATURE SAN SANITARY SF SQUARE FEET ST STORM TYP TYPICAL VB VACUUM BREAKER V VENT VTR VENT THROUGH ROOF WFU WATER FIXTURE UNITS WCO WALL CLEANOUT SYMBOL DESCRIPTION PLUMBING CONNECTION ABOVEGROUND PIPING (TYPICAL ALL SYSTEMS) - - - - - BURIED PIPING (TYPICAL ALL SYSTEMS) S SANITARY PIPING VENT PIPING ---- C1/�I- - DOMESTIC COLD WATER PIPING DOMESTIC HOT WATER PIPING �- DIRECTION OF FLOW L ISOLATION VALVE EWC ISOLATION VALVE WITH DRAIN PLUG EWC CHECK VALVE (DIRECTION OF FLOW INDICATED) WH PRESSURE AND TEMPERATURE RELIEF VALVE EWH UNION T THERMOMETER IN SEPARABLE WELL P GAGE WITH ISOLATION VALVE 1D EWC DUAL HGT PRESSURE 3 E N C PIPE RISE 1 WALL HYDRANT PIPE DROP 1 WTRHTR T DROP ] PIPE CAP --+T HOSE BIBB CO -II CLEANOUT WCO -ill WALL CLEANOUT FCO FLOOR CLEANOUT TRAP SIZE HANDICAPPED /�F ADA 1D ACCESSIBLE FIXTURE WC 1 WATER CLOSET TYPE eLAVATORY 1 TYPE L�MC 1 ELECTRICAL WATER COOLER TYPE Ms 1 MOP SINK TYPE eFLOOR 1 DRAIN TYPE IM 1 ICE MAKER CONNECTION PLUMBING CONNECTION SCHEDULE WC WC L L S EWC EWC EWC MS WH FD EWH SYMBOL 1 2D 1D WC LAV 2D LAV 1 SINK 1D EWC DUAL HGT 2D E N C 3 E N C 1 MOP SINK 1 WALL HYDRANT 1 FLRPRN 1 WTRHTR DESCRIPTION MOUNTING WC FLOOR FLOOR WALL COUNTERTOP COUNTERTOP WALL WALL WALL FLOOR WALL FLOOR TRAP SIZE INTEG. INTEG. 1 114" 1 -114" 1 -114" 1 -1/2" 1 112" 1 1/2" 3" -- 3" BRANCH DRAIN SIZE 4" 4" 1 1/2" 1-1 /2" 1-1 12" 1 -1 14" 1 114" 1 1/4" 3" " -- 314" 3" 112" -- 3/4" CW CONN. SIZE 1" 1" 318" 318" 318" 3/8" -112" 318" 318" 1 12 314" 314" 314" CW BRANCH SIZE 1-1 /4" 1 114" 314" 3/4" 314" 112" 112" 314" " 3/4" H W C O N N . SIZE -- - 318 " 3181, 318 " -- -- -- 112 " -- -- 314" H W BRANCH SIZE -- - 3 /4 " 314 " 314 " -- -- -- 314 _- -- REMARKS REMARK NUMBERS: 1. UNIT SUITABLE FOR USE BY THE PHYSICALLY DISABLED. 2. PROVIDE 112" CW TRAP PRIMER FROM LAVATORY 3. ELECTRIC WATER HEATER = 40 GALLON FLOOR MOUNTED, 4.5KW,208V11160 ' 211V 311V 3t1V 3iU 3 PVTTR E EX. W /4" VTR L —r -r—I ------ I--- r---- - - - - -- --------------------- r - -�, -- -- r-- - - - - -i --- - - - - -� V 2D i V 2D i I 2D I I I 2p le le I 111 I Y I V V V Y 3 V IV WC WC FD FD I I I I 1 D I ID C 1D 1D 1 1 1 e e e ee e I — - - - -I - - - --I I s W I r �211V 4 I - - - - -V - - - - - - - V -� i 1 I I MS W e I S V 1D V 1D e e D co c FD we we FD V GO FD W 1 1 D a 1 D 1 D TWO-WAY FCO 1 NCO F e O e I 1 �i i I I III �i I -- � I �i ♦` � I 11 I I I I I I 311 W '411:5m —7�'- siw -- ------------------ - - - - -U I 311w I I I I I l ` � ----- - - - - -- ------------------------------------------------------ - - - - -- - -- S-►-t 49. PARTIAL, SANITARY RISER DIAGRAM - CONNBCENEW4 "5ANf0Bw511ING NO SCALE BXI5TING 411 5AN TO 12BMAIN (79 wsfu, 38 GI'M) Revisions: 1 8/15/05 PLAN REVISION 2 8/22/05 PLAN REVISION 9/23/05 PLAN REVISION 4 11/29/05 PLAN REVISION Seal: Consultants: 0 ARCHITECTURAL ENGINEERING INCORPORATED 3442 EAST LAKE ROAD, PALM HARBOR, FL 34685 CONSULTING ENGINEERS (727) 784 -1472 CERTIFICATE OF AUTHORIZATION: FL 3886 W. RONALD MCILVEEN FL PE 30270 . E L E M E N T S ARCHITECTS - INTERIOR DESIGNERS Tampa Office The Edgewater Building 600 South Magnolia Avenue Suite 150 Tampa, Florida 33606 Phone (813) 251 -0565 Fax (813) 251 -0567 Miami Office 4240 Southwest 3rd Street Miami, Flog ida 33134 Phone (305) 441 -7617 Fax (305) 774 -1123 Nicholas Puglisi Architect License #AR12460 ELEMENTS State License #AA0002341 ►rll WEST GABLES BRANCH 5860 PEP pOAP MIAMI, FLOPPA Drawing No. /Dote 5,121Oy P 0.1 04-028105143 Draw in Title/Scale/Drown by �W PLUMBINGSCHEDULE NOTES AND 5c&> :