05-1471(2)-026'ROPERT
A5ME FLL . DTU
RATI;V r &P IZEI.IEF
VAI.Vt:t2 FIMV
FLPWI 5n INt21Ma1 Y
ABOVE 5E12VIC6 SINK
A
AJI2 GAr IN r9f VAVVB
PIM t215GHA946
18" HIGH HEAT TRAP
110. 2 GALLON
® EXPANSION TANK
I,AJION ( TW)
H1, ABOVE
MOP SINK OR FD FIN. FL
MOUNT EWH
ON 12" CONCRETE PAD.
ELECTRIC WATER HEATER DIAGRAM
NO SCALE
S. W. 41 T H
STREET
t� V.J � ZM�MLL: IV 1 J
Uvvn
REPLACE EX.
211V 1 -V2" VTR
W/4 VTR 311 V
r V r
S L
1 1D
Y �
WC FD
1D 1
31IW
41155M
211V
GENERAL PLUMBING NOTES (ALL "P" DRAWINGS) I PLUMBING LEGEND Notes:
P -1 REGULATORY REQUIREMENTS: PROVIDE ALL WORK TO MEET OR
EXCEED MINIMUM REGULATORY REQUIREMENTS INCLUDING:
EDITION FLORIDA BUILDING CODE: 2001 2ND EDITION, WITH
2003 REVISIONS FLORIDA FIRE PREVENTION CODE: 2002 EDITION
(EFFECTIVE 1/1/02) NFPA 1: 2002 EDITION
ADVISE THE ARCHITECT OF ANY CHANGES IN THE CONTRACT
DOCUMENTS THAT MAY BE REQUIRED IN ORDER TO MEET CODE,
PRIOR TO WORK (ORDERING, ROUGHING, OR INSTALLATION).
P -2 COORDINATION: COORDINATE WITH OTHER WORK (INCLUDING
MECHANICAL, ELECTRICAL, CIVIL /SITE, STRUCTURAL AND
ARCHITECTURAL) FOR AVAILABLE SPACE, SEQUENCE OF
INSTALLATION, AND INSTALLATION REQUIREMENTS, PRIOR TO
COMMENCING CONSTRUCTION. ADVISE THE ARCHITECT OF ANY
CHANGES IN THE CONTRACT DOCUMENTS THAT MAY BE
REQUIRED FOR THE WORK TO BE PERFORMED.
P -3 DEVICE LOCATIONS: REFER TO ARCHITECTURAL DRAWINGS
FOR EXACT LOCATION OF PLUMBING FIXTURES, PLUMBING
DEVICES, AND FIXTURE INSTALLATION HEIGHTS. LOCATE
ALL PIPING IN FINISHED ROOMS OR SPACES WITHIN
CONCEALED LOCATIONS (FURRED CHASES OR SUSPENDED
CEILINGS, AS AVAILABLE). DO NOT LOCATE PIPING ABOVE
ELECTRICAL SWITCHBOARDS OR PANELBOARDS. PROVIDE
METALLIC DRIP SHIELDS BELOW ALL PIPING IN
COMMUNICATIONS AND ELECTRICAL ROOMS.
P -4 SIZES: WHEN A PIPE SIZE IS NOT INDICATED, SIZE THAT
PIPE USING THE LARGER UPSTREAM ADJACENT SIZE, UNLESS
A SMALLER SIZE IS APPROVED BY THE ARCHITECT.
PROVIDE 3/4 INCH MINIMUM PIPE SIZE, UNLESS
SPECIFICALLY NOTED OTHERWISE. FOR SIZES NOT
INDICATED ON PLANS, REFER TO EQUIPMENT DETAILS, FLOW
DIAGRAMS, RISER DIAGRAMS, AND OTHER LOCATIONS IN THE
CONTRACT DOCUMENTS (DRAWINGS AND SPECIFICATIONS) FOR
INFORMATION.
P -5 SEALS: REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION
OF FIRE RATED PARTITIONS. SEAL ALL PENETRATIONS OF
RATED PARTITIONS.
P -6 TH
PL
INS
MC
JU
P -7 PF
IN\
FO
w SL
AS
>
cc
Q EL
l P -8 C(
1 AR
I=- P -9 PI
AC
Ln
P -10 PI
SI
CI
IN
P -11 PF
P
M
B
5' CONCRETE
SIDEWALK
".I_ . -R METER
,.. ,,
PROVIDE NEW ISOLA11ON
VALVE ON PRIVATE
PROPERTY SIDE OF METER.
V-4
I L II
1 D 2D
FID WC 'rQ
1 1D
1V 31IV
E PLUMBING INSTALLER IS ADVISED THAT THE INDICATED
JMBING SYSTEM MAY NOT BE REDESIGNED BY THE PLUMBING
)TALLER (NOT A CONTRACTOR DESIGNED SYSTEM), UNLESS
IDIFICATIONS ARE REQUIRED BY THE AUTHORITY HAVING
RISDICTION.
IOR TO COMMENCING CONSTRUCTION, REVERIFY PIPE
(ERTS WITH STRUCTURAL FOOTINGS AND DEPRESS
OTINGS, AS REQUIRED FOR PIPE INSTALLATION. PROVIDE
EEVES FOR BURIED PIPING AT WALLS AND FOUNDATIONS,
REQUIRED BY THE STANDARD PLUMBING CODE.
ORDINATE PIPE INVERTS AND FINISHED FLOOR
EVATIONS.
)ORDINATE ALL WALL CLEANOUTS (WCO) WITH
CHITECTURAL CASEWORK, PRIOR TO INSTALLATION.
ROVIDE ACCESS DOORS IN BUILDING CONSTRUCTION FOR
:CESS TO VALVES AND TRAPS.
ROVIDE OFFSETS IN ALL PIPING AT COUNTER MOUNTED
NKS, AS REQUIRED (ALL OFFSETS ARE NOT SHOWN FOR
ARITY). COORDINATE WITH CABINET WORK, PRIOR TO
STALLATION.
;OVIDE GALVANIZED STEEL STAND -OFF BRACKET /CHANNEL TO
ROVIDE 1/2 INCH (MINIMUM) AIR GAP WHEN DEVICES ARE
OUNTED ON EXTERIOR WALLS (TO REDUCE MOLD /MILDEW
UILDUP).
WH WALL HYDRANT TYPE
1
WHA WATER HAMMER ARRESTER: PDI SIZE INDICATED
B
BP BACKFLOW PREVENTER TYPE: SIZE INDICATED
2
EWH ELECTRIC WATER HEATER NUMBER
1 -1
02 DRAWING NOTE: REFER TO NOTES ON EACH DRAWING
AFF
ABOVE FINISHED FLOOR
CLG
CEILING
CO
CLEANOUT
CW
COLD WATER
DFU
DRAINAGE FIXTURE UNITS
DN
DOWN
DWG
DRAWING
EA
EACH
ELECT
ELECTRICAL
EPO
EMERGENCY POWER OFF SWITCH
FCO
FLOOR CLEANOUT
FIN FL ELEV
FINISHED FLOOR ELEVATION
FLA
FULL LOAD AMPS
FT
FEET
GPM
GALLONS PER MINUTE
HP
HORSEPOWER .
HVAC
HEATING, VENTILATING, AND AIR CONDITIONING
HW
HOT WATER
HWRC
HOT WATER RECIRCULATING PIPING
IN
INCH
INV
INVERT "
LBS
POUNDS
MAX
MAXIMUM
MCA
MINIMUM CIRCUIT AMPS
MIN
MINIMUM
MOCP
MAXIMUM OVERCURRENT PROTECTION
NC
NORMALLY CLOSED
NO
NORMALLY OPEN
P &T
PRESSURE AND TEMPERATURE
SAN
SANITARY
SF
SQUARE FEET
ST
STORM
TYP
TYPICAL
VB
VACUUM BREAKER
V
VENT
VTR
VENT THROUGH ROOF
WFU
WATER FIXTURE UNITS
WCO
WALL CLEANOUT
SYMBOL DESCRIPTION
PLUMBING CONNECTION
ABOVEGROUND PIPING (TYPICAL ALL SYSTEMS)
- - - - -
BURIED PIPING (TYPICAL ALL SYSTEMS)
S
SANITARY PIPING
VENT PIPING
---- C1/�I- -
DOMESTIC COLD WATER PIPING
DOMESTIC HOT WATER PIPING
�-
DIRECTION OF FLOW
L
ISOLATION VALVE
EWC
ISOLATION VALVE WITH DRAIN PLUG
EWC
CHECK VALVE (DIRECTION OF FLOW INDICATED)
WH
PRESSURE AND TEMPERATURE RELIEF VALVE
EWH
UNION
T
THERMOMETER IN SEPARABLE WELL
P
GAGE WITH ISOLATION VALVE
1D
EWC DUAL HGT
PRESSURE
3
E N C
PIPE RISE
1
WALL HYDRANT
PIPE DROP
1
WTRHTR
T DROP
]
PIPE CAP
--+T
HOSE BIBB
CO -II
CLEANOUT
WCO -ill
WALL CLEANOUT
FCO
FLOOR CLEANOUT
TRAP SIZE
HANDICAPPED /�F ADA
1D
ACCESSIBLE FIXTURE
WC
1
WATER CLOSET TYPE
eLAVATORY
1
TYPE
L�MC
1
ELECTRICAL WATER COOLER TYPE
Ms
1
MOP SINK TYPE
eFLOOR
1
DRAIN TYPE
IM
1
ICE MAKER CONNECTION
PLUMBING CONNECTION
SCHEDULE
WC
WC L
L
S
EWC
EWC
EWC
MS
WH
FD
EWH
SYMBOL
1
2D 1D
WC LAV
2D
LAV
1
SINK
1D
EWC DUAL HGT
2D
E N C
3
E N C
1
MOP SINK
1
WALL HYDRANT
1
FLRPRN
1
WTRHTR
DESCRIPTION
MOUNTING
WC
FLOOR
FLOOR WALL
COUNTERTOP COUNTERTOP
WALL
WALL
WALL
FLOOR
WALL
FLOOR
TRAP SIZE
INTEG.
INTEG. 1 114"
1 -114"
1 -114"
1 -1/2"
1 112"
1 1/2"
3"
--
3"
BRANCH DRAIN SIZE
4"
4" 1 1/2"
1-1 /2"
1-1 12"
1 -1 14"
1 114"
1 1/4"
3"
"
--
314"
3"
112"
--
3/4"
CW CONN. SIZE
1"
1" 318"
318"
318"
3/8"
-112"
318"
318"
1 12
314"
314"
314"
CW BRANCH SIZE
1-1 /4"
1 114" 314"
3/4"
314"
112"
112"
314"
"
3/4"
H W C O N N . SIZE
--
- 318 "
3181,
318 "
--
--
--
112
"
--
--
314"
H W BRANCH SIZE
--
- 3 /4 "
314 "
314 "
--
--
--
314
_-
--
REMARKS
REMARK NUMBERS:
1. UNIT SUITABLE FOR USE BY THE PHYSICALLY DISABLED.
2. PROVIDE 112" CW TRAP
PRIMER
FROM LAVATORY
3. ELECTRIC WATER HEATER = 40
GALLON FLOOR MOUNTED, 4.5KW,208V11160
'
211V 311V
3t1V
3iU
3 PVTTR E EX.
W /4" VTR
L —r -r—I ------ I--- r---- - - - - -- ---------------------
r - -�, -- -- r-- - - - - -i --- - - - - -�
V 2D i V 2D i I 2D I I I 2p
le le I 111 I Y I
V V V Y 3 V IV
WC WC FD FD I I I I 1 D I ID
C 1D 1D 1 1 1 e e
e ee e
I — - - - -I - - - --I I
s W I r �211V
4 I
- - - - -V - - - - - - - V -� i 1
I I MS
W e I S V 1D V
1D e e
D co c FD we we
FD V GO FD W
1 1 D a 1 D 1 D TWO-WAY FCO
1 NCO F e
O e
I 1 �i i I I III �i I -- � I �i ♦` � I
11 I I I I I I 311 W '411:5m —7�'-
siw -- ------------------ - - - - -U I
311w
I I I I I
l ` �
----- - - - - -- ------------------------------------------------------ - - - - -- - -- S-►-t 49.
PARTIAL, SANITARY RISER DIAGRAM - CONNBCENEW4 "5ANf0Bw511ING
NO SCALE BXI5TING 411 5AN TO 12BMAIN (79 wsfu, 38 GI'M)
Revisions:
1 8/15/05 PLAN REVISION
2 8/22/05 PLAN REVISION
9/23/05 PLAN REVISION
4
11/29/05 PLAN REVISION
Seal:
Consultants:
0
ARCHITECTURAL ENGINEERING INCORPORATED
3442 EAST LAKE ROAD, PALM HARBOR, FL 34685
CONSULTING ENGINEERS (727) 784 -1472
CERTIFICATE OF AUTHORIZATION: FL 3886
W. RONALD MCILVEEN FL PE 30270
.
E L E M E N T S
ARCHITECTS - INTERIOR DESIGNERS
Tampa Office
The Edgewater Building
600 South Magnolia Avenue
Suite 150
Tampa, Florida 33606
Phone (813) 251 -0565
Fax (813) 251 -0567
Miami Office
4240 Southwest 3rd Street
Miami, Flog ida 33134
Phone (305) 441 -7617
Fax (305) 774 -1123
Nicholas Puglisi Architect License #AR12460
ELEMENTS State License #AA0002341
►rll
WEST GABLES BRANCH
5860 PEP pOAP
MIAMI, FLOPPA
Drawing No. /Dote 5,121Oy
P 0.1
04-028105143
Draw in Title/Scale/Drown by �W
PLUMBINGSCHEDULE
NOTES AND
5c&> :