05-1471(2)-0106 I /8"
SECOND FLOOR PLAN
SCALE: 3116"=V-0"
N
BUILDING CODE INFORMATION:
CODES UTILIZED: FLORIDA BUILDING CODE, 2001
BUILDNG SQUARE FOOTAGE FIRST FLOOR: 6,331
BUILDING SQUARE FOOTAGE SECOND FLOOR: 6,331
BUILDING SQUARE FOOTAGE TOTAL: 12,614
OCCUPANCY TYPE: BUSINESS
OCCUPANCY LOAD: 1 PERSON/100 SF. GROSS (12614 SF/100 OR = 121 PEOPLE)
BUILDNG TYPE: TYPE V, UN- SPRNKLERED, UN- PROTECTED
SCOPE OF WORK: INTERIOR REMODEL OF EXISTING
OCCUPANT LOAD FOR SECOND FLOOR CLASSROOMS
ALL SECOND FLOOR CLASSROOMS SHALL BE UTILIZED FOR
EDUCATIONAL PURPOSES ABOVE GRADE 12.
OCCUPANT LOAD PER FBC 2001 TABLE 1003.1 ■ I PERSON/20 NET SQ. FT.
TELLER LECTURE (RM. 219) = 660 SQ. FT. / 20 NET a 33 OCCUPANTS
GENERAL LECTURE (R'1.218) ■ 519 SQ. FT. / 20 NET ■ 2S OCCUPANTS
TELLER TRANSACTION CLASSROOM (W 211) = 151 SQ FT. / 20 NET = 38 OCCUPANTS
MULTI -MEDIA LEARNNG CLASSROOM (R`1.216) = 511 SQ. FT. / 20 NET = 26 OCCUPANTS
READY TALENT / LECTURE (RIt 215) = 1,140 SQ. FT. / 20 NET = 51 OCCUPANTS
GENERAL NOTES:
I. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS
GOVERN OVER SMALL SCALE.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR SEEING THAT NEW
CONSTRUCTION CONFORMS TO ALL APPLICABLE STATE AND
MUNICIPAL CODES INCLUDING ALL STATE LAWS, LOCAL APPLICABLE
REQUIREMENTS OF THE FLORIDA BUILDING CODE, FLORIDA
ACCESSIBILITY GUIDELINES AND THE AMERICANS WITH DISABILITIES
ACT.
3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS PRIOR
TO FABRICATION, (TYPICAL).
4. PROVIDE WALL BRACING/BLOCKING AS NECESSARY FOR ALL
WALL MOUNT CABINETS, FIXTURES, AND EQUIPMENT.
LEGEND
SYMBOL DESCRIPTION
N
NORTH ARROW
IOIA
DOOR AND DOOR TAG. REFER TO DOOR
Id
SCHEDULE FOR SPECIFICATIONS
X
XXX
X
INTERIOR ELEVATION MARK
P -5
PARTITION TYPE SEE SHEET A51
X
/
r 1
ENLARGED DETAIL MARK
DIMENSIONS:
INDICATES DIMENSION TO FACE OF G11JB.
PARTITIONS OR COL.
INDICATES DIMENSION TO FACE OF EXISTING
CONSTRUCTION
NOTE: VERIFY ALL EXISTING DIMENSIONS IN FIELD
Notes:
Revisions:
I 8 -15 -05 PLAN REVISION
8 -22 -05 PLAN REVISION
9 -19 -05 PLAN REVISION
Seal:
Consultants:
E L E-MI-E _N__T
ARCHITECTS -INTERIOR vESIGNER3
Tampa-- Office
The Edgewater Building ----
600 South _lagnolic _AYenue - - - - - -
Suite 150 -
Tampa,- Florida 3 ,3u o
- - -- - - - - -_ - - -- _ Phone '313)- 251 -G565
Fax X813))- 251 -L-5Fi =
:. '...'' Miami- Office ,
4240 Southwest 3rd Street -
Miami, Florida 33134
�~ Phone (305) 441 -7617
---.4' Fax (305) 774 -1123
Nicholas Puglisi Architect License #AR12460
ELEMENTS State License # AA0002341
WEST GABLES BRANCH
5880 BIRD ROAD
MIAMI, FLORIDA
Drawing No. /Date 8/1/05
A-3.2
04 -028
Drawing Title /Scale /Drawn by BDL
SECOND FLOOR PLAN
SCALE; AS NOTED
Id
Consultants:
E L E-MI-E _N__T
ARCHITECTS -INTERIOR vESIGNER3
Tampa-- Office
The Edgewater Building ----
600 South _lagnolic _AYenue - - - - - -
Suite 150 -
Tampa,- Florida 3 ,3u o
- - -- - - - - -_ - - -- _ Phone '313)- 251 -G565
Fax X813))- 251 -L-5Fi =
:. '...'' Miami- Office ,
4240 Southwest 3rd Street -
Miami, Florida 33134
�~ Phone (305) 441 -7617
---.4' Fax (305) 774 -1123
Nicholas Puglisi Architect License #AR12460
ELEMENTS State License # AA0002341
WEST GABLES BRANCH
5880 BIRD ROAD
MIAMI, FLORIDA
Drawing No. /Date 8/1/05
A-3.2
04 -028
Drawing Title /Scale /Drawn by BDL
SECOND FLOOR PLAN
SCALE; AS NOTED