Loading...
05-1471(2)-0106 I /8" SECOND FLOOR PLAN SCALE: 3116"=V-0" N BUILDING CODE INFORMATION: CODES UTILIZED: FLORIDA BUILDING CODE, 2001 BUILDNG SQUARE FOOTAGE FIRST FLOOR: 6,331 BUILDING SQUARE FOOTAGE SECOND FLOOR: 6,331 BUILDING SQUARE FOOTAGE TOTAL: 12,614 OCCUPANCY TYPE: BUSINESS OCCUPANCY LOAD: 1 PERSON/100 SF. GROSS (12614 SF/100 OR = 121 PEOPLE) BUILDNG TYPE: TYPE V, UN- SPRNKLERED, UN- PROTECTED SCOPE OF WORK: INTERIOR REMODEL OF EXISTING OCCUPANT LOAD FOR SECOND FLOOR CLASSROOMS ALL SECOND FLOOR CLASSROOMS SHALL BE UTILIZED FOR EDUCATIONAL PURPOSES ABOVE GRADE 12. OCCUPANT LOAD PER FBC 2001 TABLE 1003.1 ■ I PERSON/20 NET SQ. FT. TELLER LECTURE (RM. 219) = 660 SQ. FT. / 20 NET a 33 OCCUPANTS GENERAL LECTURE (R'1.218) ■ 519 SQ. FT. / 20 NET ■ 2S OCCUPANTS TELLER TRANSACTION CLASSROOM (W 211) = 151 SQ FT. / 20 NET = 38 OCCUPANTS MULTI -MEDIA LEARNNG CLASSROOM (R`1.216) = 511 SQ. FT. / 20 NET = 26 OCCUPANTS READY TALENT / LECTURE (RIt 215) = 1,140 SQ. FT. / 20 NET = 51 OCCUPANTS GENERAL NOTES: I. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR SEEING THAT NEW CONSTRUCTION CONFORMS TO ALL APPLICABLE STATE AND MUNICIPAL CODES INCLUDING ALL STATE LAWS, LOCAL APPLICABLE REQUIREMENTS OF THE FLORIDA BUILDING CODE, FLORIDA ACCESSIBILITY GUIDELINES AND THE AMERICANS WITH DISABILITIES ACT. 3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS PRIOR TO FABRICATION, (TYPICAL). 4. PROVIDE WALL BRACING/BLOCKING AS NECESSARY FOR ALL WALL MOUNT CABINETS, FIXTURES, AND EQUIPMENT. LEGEND SYMBOL DESCRIPTION N NORTH ARROW IOIA DOOR AND DOOR TAG. REFER TO DOOR Id SCHEDULE FOR SPECIFICATIONS X XXX X INTERIOR ELEVATION MARK P -5 PARTITION TYPE SEE SHEET A51 X / r 1 ENLARGED DETAIL MARK DIMENSIONS: INDICATES DIMENSION TO FACE OF G11JB. PARTITIONS OR COL. INDICATES DIMENSION TO FACE OF EXISTING CONSTRUCTION NOTE: VERIFY ALL EXISTING DIMENSIONS IN FIELD Notes: Revisions: I 8 -15 -05 PLAN REVISION 8 -22 -05 PLAN REVISION 9 -19 -05 PLAN REVISION Seal: Consultants: E L E-MI-E _N__T ARCHITECTS -INTERIOR vESIGNER3 Tampa-- Office The Edgewater Building ---- 600 South _lagnolic _AYenue - - - - - - Suite 150 - Tampa,- Florida 3 ,3u o - - -- - - - - -_ - - -- _ Phone '313)- 251 -G565 Fax X813))- 251 -L-5Fi = :. '...'' Miami- Office , 4240 Southwest 3rd Street - Miami, Florida 33134 �~ Phone (305) 441 -7617 ---.4' Fax (305) 774 -1123 Nicholas Puglisi Architect License #AR12460 ELEMENTS State License # AA0002341 WEST GABLES BRANCH 5880 BIRD ROAD MIAMI, FLORIDA Drawing No. /Date 8/1/05 A-3.2 04 -028 Drawing Title /Scale /Drawn by BDL SECOND FLOOR PLAN SCALE; AS NOTED Id Consultants: E L E-MI-E _N__T ARCHITECTS -INTERIOR vESIGNER3 Tampa-- Office The Edgewater Building ---- 600 South _lagnolic _AYenue - - - - - - Suite 150 - Tampa,- Florida 3 ,3u o - - -- - - - - -_ - - -- _ Phone '313)- 251 -G565 Fax X813))- 251 -L-5Fi = :. '...'' Miami- Office , 4240 Southwest 3rd Street - Miami, Florida 33134 �~ Phone (305) 441 -7617 ---.4' Fax (305) 774 -1123 Nicholas Puglisi Architect License #AR12460 ELEMENTS State License # AA0002341 WEST GABLES BRANCH 5880 BIRD ROAD MIAMI, FLORIDA Drawing No. /Date 8/1/05 A-3.2 04 -028 Drawing Title /Scale /Drawn by BDL SECOND FLOOR PLAN SCALE; AS NOTED