05-1471(2)-005EXISTING CONCRETE SLAB. NEW STEEL BEAM, SEE PLAN NEW PL 1"x14 "xl' -2" - W/ (4) -Y4"0 EXPANSION ANCHORS. SEE 1 /S4.0. O � t • .ySR..i - `-, n ELEVATOR SLAB @ ROOF L/ SCALE: 1" = 1' -0" EXISTING SLAB #3 ® 16" O.C. SET IN EPDXY W/ 5" EMBEDMENT. #3 ® 16" O.C. NEW CONCRETE SLAB, SEE PLAN 16" DEEP BOND BEAM W/ 2 - #5 ALL SIDES WITH CORNER BARS NEW CMU WALL, SEE PLAN #4x2' -0" SET IN EPDXY. 2 - #4 CONT. NEW SLAB ON GRADE, SEE PLAN d q 4 d r !!! ,) =1 � 11 =1 ! I I 1 =1 I { =1 ! 1 =1 11= III =1 I 1 ; d 43 • C d a � d • • � d d ! ! ( -! ! q G c I- 4 #5 ®9 O.C. E.W. BOTTOM. TRANSVERSE BAR TO BE SET IN EPDXY WITH HOOK AS SHOWN. EXISTING FOUNDATION #5 0 12" O.C. E.W. SET IN EPDXY WITH HOOK AS SHOWN. EXISTING FO UNDATION EXPANSION 11 SCALE. 1 " = -0" SEE ARCHT DWGS. FOR STEEL STRINGER & TREAD DETAILS & DIMENSIONS L4x4x%x4" LG. W/ (1� "0x5" WEDGE ANCHOR die FIN. FL. • a O e ° I (2) #4 CONT. DOWEL TO BEAM . OR TURNDOWN AT ENDS ` WHERE APPLICABLE ALIGN FACE OF TURNDOWN W/ 8M INTERIOR POUR TURNDOWN CONT. BETWEEN END OF STAIR STRINGER 18 EXTERIOR PARALLEL STRINGERS, EXTEND U.N.O. ON PLAN TURNDOWN A MIN. OF 2' -0" PAST EA. END U.N.O. ON PLAN NOTES: 1. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF STAIR STRINGER LOCATIONS WITH ARCHITECTURAL DRAWINGS AND PROVIDE TURNDOWNS WHERE REQUIRED WHETHER SHOWN ON STRUCTURAL DRAWINGS OR NOT. 2. CLIP ANGLE TO BE HIDDEN BENEATH FIRST TREAD. WHERE OPEN RISERS ARE USED, COORDINATE THE LOCATION WITH THE ARCHITECT. SLAB TURNDOWN @ STEEL S TAI R C `o u V O EXISTING ROOF SLAB SHIM AS REQUIRED % "0 EXPANSION ANCHORS ® 24" O.C. ALTERNATE EACH SIDE OF BEAM WEB. NEW STEEL BEAM, SEE PLAN EXISTING STEEL JOIST STEEL BEAM AT EXISTING ROOF SLAB SCALE: N.T.S. 8" CMU REINF. W/ PIT WALLS & SLAB PROVIDED #5 0 32" O.C. IN BP -01 (1) #3 CONT. ® EDGE W/ #3x4' -0" CORNER BARS 2' -0" . /- (2) #5 CONT. T &B OF WALL .III III -f I I =f I I -I I• .° FORM THE DIRT FACE OF WALL i - Nr #4 ® 12" VERT. #4 ®12 DWLS. INSIDE FACE Of W ° � U #4 CONT. ® 12" INSIDE FACE I o W/ EQUIV. CORNER BARS I -II- 1 ' FOR SLOPE, REF. N 11 4° : " ' NOTE 2 �I_. y _ CONT. WATERSTOP, SEE SPECS. - I�. • " FOR TYPE, TYP. 00 CONT. SHEAR KEY T &B OF WALL -III -III #4 ® 12" EA. WAY TOP NOTES: 1. BRACE WALL AS REQUIRED UNTIL UPPER SLAB IS POURED AND HAS REACHED 2500 psi MINIMUM. 2. SEE PLAN FOR SUMP PIT, WHERE REQUIRED. SLOPE PIT BOTTOM SLAB 1" TO SUMP PIT. 3. SEE OTHER DETAILS FOR ELEVATOR SILL DETAIL. 4. GENERAL CONTRACTOR TO COORDINATE ELEVATOR PIT SIZE, DEPTH, SILL DETAIL, AND BLOCKOUT REQUIREMENTS WITH ELEVATOR'S MANUFACTURER'S APPROVED SHOP DRAWINGS. 5. WHERE ELEVATOR PIT SLAB IS BLOCKED OUT TO ALLOW FOR PLACEMENT OF HYDRAULIC ELEVATOR JACK, FILL BLOCKOUT WITH CONCRETE AFTER JACK IS SET. ELEVATOR PIT SCALE: N.T.S. STFFL RFAM.� ■ -1 =r- EXISTING CONCRETE SLAB. EXISTING STEEL - BAR JOIST. ELEVATOR SLAB ROOF SCALE: 1" = 1' -0" #3 ® 16" O.C. SET IN EPDXY W/ 5" EMBEDMENT. #3 0 16" O.C. NEW CONCRETE SLAB, SEE PLAN 16" DEEP BOND BEAM W/ 2 - #5 ALL SIDES WITH CORNER BARS NEW CMU WALL, SEE PLAN I ( -I I • 1 =I I I I SEE PIT DETAIL FOR PIT WALL & BOTTOM SLAB REINF. O I " IIIIIII� -III SLOPE PIT BOTTOM SLAB _ -1 I � I =I I �•° • _ _ DOWN 1 TO SUMP PIT d ° - I -I -1 I -I I {- ° ° ♦- • ° ° d O• III -I 1 I- _ a III -I I 2' -0" SQ. U.N.O. • N I4 . 14 I I- III -f II I) d° °a .. ♦ �.� .d I-- III -I I i- ' ICI =ICI CONT. SHEAR KEY EA. WAY Lr =1 I I I I I =! 1 I I I I -► I I =1 I I =1 I I -► I I =) I I -1 I I- ' I Ii) l l' (2) #4 W/ WATERSTOP NOTE: SEE PLAN FOR LOCATION AND SIZE WHERE DIFFERENT FROM DIMENSIONS SHOWN IN THIS DETAIL \ ELEVATOR SUMP PIT SCALE: N.T.S. �- EXTEND EVERY SEE PLAN ` OTHER BAR 1' -0" PAST NEAREST INSTALL POUR STOPS PRIOR TO PLACING OF CONCRETE (1) #5, TYP. 1 I I (2) #5 BOTTOM " • A 2' -0" A TYP. 2" 1,- III J. "A" MIN. IV v 'A" Y W 0 (1) #5 (2) #5 BOTTOM BEAM AS SHOWN x 2' -0" TYP. 4 11 x \ / \ 2 ", TYP. STEEL BEAM. g4x(HOLE 0 + 2' -0 ") (1) #5 4" MIN. BETWEEN SLEEVES WHEN SPACING EXCEEDS 1' -0 ", PROVIDE BAR ADJACENT TO EA SLEEVE SEE PLAN SINGLE OPENING (2) #5 BOT OMY� MULTIPLE OPENINGS PIPE SLEEVES NOTES: 1. "A" = OPENING DIMENSION IN THE DIRECTION PERPENDICULAR TO DECK SPAN. USE THIS DETAIL FOR "A" </= 4' -0" WHEN SPACING BETWEEN MULTIPLE OPENINGS IS </= 2'-Ow, REINFORCEMENT SHOULD BE PLACED AS SHOWN IN SINGLE OPENING CONDITION. 2. COORDINATE OPENING SIZE AND LOCATION WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. 3. MAXIMUM DIMENSION "A' SHALL BE 4' -0 ". REFER TO PLAN OR DETAIL ON DRAWINGS FOR FRAMING OF OPENINGS GREATER THAN 4' -0 ". 4. WWF SLAB REINFORCEMENT SHALL BE CUT AROUND SLAB OPENING. WWF SHALL EXTEND TO WITHIN 2" OF OPENING ON ALL SIDES. 5. OPENINGS 10" AND SMALLER DO NOT REQUIRE ADDITIONAL REINFORCEMENT. 6. FIELD CUT OPENINGS IN DECK AFTER CONCRETE SLAB HAS BEEN POURED AND HAS ATTAINED MINIMUM 75% OF ITS SPECIFIED 28 DAY COMPRESSIVE STRENGTH. DO NOT FIELD CUT METAL DECK UNTIL IMMEDIATELY BEFORE OPENING IS NEEDED. 7. REINFORCEMENT PERPENDICULAR TO DECK SPAN SHALL BE PLACED ON TOP OF DECK FLUTES. 8. REINFORCEMENT PARALLEL TO DECK SPAN SHALL BE PLACED IN THE LOWER FLUTE AND SHALL BE CHAIR TO PROVED X" COVER. 9. THIS DETAIL SHOWS TYPICAL CONDITIONS. VERIFY REINFORCING STEEL PLACEMENT WITH ENGINEER FOR SPECIAL CASES. 10. PROVIDE REINFORCEMENT AS SHOWN FOR SQUARE, RECTANGULAR OR ROUND OPENINGS. OPENING IN COMPOSITE METAL DECK SLAB (FLOOR OR ROOF) SCALE: N.T.S. 7 SCALE: N.T.S. U t� 4 OF BEAM MR. DECK SLAB REINFORCING I CONT. HIGH CHAIRS MTL DECK MR. DECK -0" MAX OF GIRDER I NOTES: 1. SEE GENERAL NOTES FOR METAL DECK SLAB TEMPERATURE REINFORCEMENT. 2. PROVIDE CONTINUOUS HIGH CHAIRS EACH WAY. WIRE MESH SUPPORT BARS SCALE: 3/4" = 1' -0" 1.5" 1.5" 1.5" 1.5" 1.5" + + COLUMN COLUMN POUR SLAB DOWN ALL AROUND COLUMN COLUMN & FTG, U.N.O. BASE PLATE AS SHOWN. SLAB MAY BE SEE PLAN POURED DOWN OVER ENTIRE FIG. AT PER RISC SPEC'S CONTRACTOR'S OPTION. PER MIN.) %* NON- SHRINK GROUT I �6" BASE PLATE W/ ANCHOR RODS PER 9/S4.1 1-91, m lit-i 3" MIN. - .I NOTES: 1. SEE PLAN FOR FOOTING SIZES AND REINFORCEMENT. 2. SEE PLAN FOR TOP OF FOOTING ELEVATIONS. 3. USE OVERSIZED HOLES FOR ANCHOR RODS ACCORDING TO AISC SPECIFICATIONS. 4. WASHERS SHALL BE INSTALLED OVER OVERSIZED HOLES. 5. CONTRACTOR SHALL PROVIDE )6" THICK TEMPLATE FOR ANCHOR ROD INSTALLATION. 6. FINISH COLUMN AND TOP OF BASE PLATE ACCORDING TO AISC SPECIFICATIONS. STEEL COLUMN ON SPREAD FOOTING SCALE: N.T.S. MINIMUM LENGTH AS REQ'D TO ACCOMMODATE GROUT, BASE PLATE, WASHER, NUT, PLUS 11¢" PLATE WASHER, SEE GENERAL NOTES T.O. COLUMN BASE PLATE T.O. CONCRETE HEAVY HEX NUT r Y4"0 ANCHOR ROD ASTM F1554, GR36 NOTES: 1. BOLT THREADS AT THE EMBEDDED END SHALL BE STRIKED AT TWO PLACES BELOW THE HEAVY HEX NUT. 2. UNLESS NOTED OTHERWISE, ALL BOLTS SHALL BE TIGHTENED TO A "SNUG TIGHT" CONDITION AS DEFINED BY AISC AFTER THE CONCRETE IS AT LEAST 14 DAYS OLD. 3. THE HOLE IN THE PLATE WASHER SHALL BE YOB" LARGER THAN THE BOLT DIAMETER. TYPICAL ANCHOR ROD SCALE: N.T.S. Notes: I I I I Revisions: I I I Seal: Consultants: DECAROWILLSON STRUCTURAL ENGINEERS 1705 N. 16TH STREET, TAMPA, FLORIDA 33605 PHONE (813) 817.4707 FAx (813) 262.2338 CERTIFICATE OF AUTHORIZATION #. 25896 JOHN L. DECARO, P.E. No. 56031 ft* go 1 ..I ♦ • to L E-M E I ♦mss <!. �� ARCHITECTS • INTERIOR- -DESIGN`RS- __ Torrpo O_- ffi_ce- - The EdgEvrater -EE,3uifdin6 600 South Magnolia Avenue - Suite 150 Tampa, Florida 33606 Phone (813) 251 -0565 Fax (813) 251 -0567 Miami Office 4240 Southwest 3rd Street Miami, Florida 33134 Phone (305) 441 -7617 Fax (305) 774 -1123 Nicholas Puglisi Architect License #AR12460 ELEMENTS State License #AA0002341 T � � WEST (SABLES BRANCH 5880 BIRD ROAD MIAMI, FLORIDA Drawing No. /Date 05 -02 -05 S -3.0 05 -111 Drawing Title /Scale /Drawn by VW TYPICAL DETAILS