05-1213-006POOL SAFETY DEVICES: AS PER THE FLORIDA BUILDING CODE, THIS POOL AND /OR SPA SHALL BE PROTECTED (AT THE OWNER'S EXPENSE)FROM UNAUTHORIZED AQCCESS IN ACCORDANCE WITH ONE OF THE FOLLOWING: 1. A PERIMETER FENCE SHALL BE LOCATED AROUND THE POOL UTILIZING A PART OF THE HOUSE AS A BARRIER. THIS METHOD, AT THE OWNER'S EXPENSE, SHALL REQUIRE COMPLIANCE WITH ARTICLE 424.2.17 OF THE 'FLORIDA BUILDING CODE. ACCESS THROUGH THE BARRIER SHALL BE THROUGH SELF CLOSING, SELF LATCHING GATES COMPLYING WITH THE ABOVE INDICATED ARTICLE. IF A PART OF THE HOUSE IS TO BE USED AS THE BARRIER, ALL DOORS AND WINDOWS WITH DIRECT ACCESS TO THE POOL SHALL BE EQUIPPED WITH AN EXIT ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85 dB A AT 10 FEET AND IS EITHER HARD WIRED OR OF THE PLUG -IN TYPE. THE EXIT ALARM SHALL PRODUCE A CONTINUOUS AUDIBLE WARNING WHEN THE DOOR AND ITS SCREEN ARE OPENED. THE ALARM SHALL SOUND IMMEDIATELY AFTER THE DOOR IS OPENED AND BE CAPABLE OF BEING HEARD THROUGHOUT THE HOUSE DURING NORMAL HOUSEHOLD ACTIVITIES. THE ALARM SHALL BE EQUIPPED WITH A MANUAL MEANS TO TEMPORARILY DEACTIVATE THE ALARM FOR A SINGLE OPENING. SUCH DEACTIVATION SHALL LAST NO LONGER THAN 15 SECONDS. THE DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES ABOVE THE THRESHOLD OF THE DOOR. 2. A SAFETY NET OR COVER SHALL BE INSTALLED COMPLETELY COVERING THE SURFACE OF THE POOL AND /OR SPA THEREBY PREVENTING ACCESS TO THE WATER. THE NET OR COVER SHALL BE IN COMPLIANCE WITH ASTM F1346 -91. 3. A CHILD SAFETY FENCE (KIDDIE FENCE) A MINIMUM OF 48 INCHES IN HEIGHT SHALL BE INSTALLED AROUND THE PERIMETER OF THE POOL PREVENTING ACCESS TO THE WATER FROM ALL DIRECTIONS. THE SAFETY FENCE SHALL BE PERMANENTLY INSTALLED AT ONE END WHICH CAN ONLY BE REMOVED BY TOOLS. 4. A COMBINATION OF THE PERIMETER FENCE AND CHILD FENCE MAY BE USED TO PREVENT ACCESS TO THE POOL PROVIDED THE CHILD FENCE IS INSTALLED IN COMPLIANCE WITH ITEM 3 ABOVE. OPTIONAL 2" BULLNOSE TIL NOTE — STEP NOT REQUINLU 18" 12" 12" STEP SECTION NOT TO SCALE 0 36" 4 RISERS AT 10" EACH 2" BULLNOSE TILE NOSING 6" #3@ 9" 0. C. E.W. AT MID —DEPTH _10 SWI M OU T SECTION NOT TO SCALE BOND WIRE TO POOL STEEL NOTE: BOND WIRE TO BE SECURED TO STEEL WITH APPROVED CLAMP. CLAMP TO BE ENCASED IN DECK SLAB OR CONCRETE BOX PROVIDING MIN. 3" OF COVER AROUND CLAMP 1" NON METALIC CONDUIT TO JUNCTION BOX 2 #3 BARS/ ACROSS NICHE POOL WALL STEEL LIGHT BOUY UNDERWATER LIGHT DETAIL NO SCALE 200A HOUSE, DISC. PANEL 200 FPL METER Q AMP TIMER 20A SWITCH � 3 #12 THWN IN 1/2" COND.____ 2 HP PUMP ** 14 FOR 75 & 100W 12 FOR 150W 10 FOR 200 & 30OW 1- 2P -50A 2 #8 THWN + 1 #10 THHN IN 1- 2P -20A 1/2" COND. 1- 1P -15A/ 5 HP HEAT PUMP 50A DISC �1� I N 2'THOD 1 #12 THWN CN 24V. DC TRANSORMER CHLORMATIC SWITCH 16V TRANSFORMER JUNCTION BOX 12V 150W POOL LIGHT 1Z C� 75W 12V 2 # ** + 1 #12 YH WN SPA IN \" COND. LIGHT RISER DIAGRAM PLUMBING NOTES: 1. ALL POOL AND EQUIPMENT PIPING SHALL BE SCHEDULE 40, PVC —PW, NON— THREADED, NSF APPROVED SUPPORTED CONTINUOUSLY ON GROUND OR ON - MAXIMUM 4'0" CENTERS WITH CLEVIS HANGERS. 2. ALL SUCTION PIPING SHALL BE 2" DIAMETER AND ALL PRESSURE PIPING 1 1/2" DIAMETER UNLESS OTHERWISE NOTED. 3. POOL WATER DISPOSAL SHALL BE IN ACCORDANCE WITH LOCAL BUILDING DEPARTMENT REQUIREMENTS. 4. ANTI VORTEX MAINDRAINS SHALL HAVE ITS PLATE SECURELY FASTENED WITH TAMPERPROOF SCREWS. 5. POOL VACUUM SHALL HAVE SPRING LOADED CAP IN ACCORDANCE WITH THE FLORIDA BUILDING CODE. 6. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE— PLUMBING SECTION 309 AS IT PER- TAINS TO BOUYANCY. 7. THE WATER VELOCITY THROUGH ALL SUCTION PIPING SHALL BE LESS THAN 8 FEET PER SECOND. 8. THE WATER VELOCITY THROUGHT ALL PRESSURE PIPING SHALL BE LESS THAN 10 FEET PER SECOND. 9. ALL PIPING SHALL BE SUITABLE FOR EXPOSURE TO ULTRA VIOLET RADIATION AND NORMAL OPERATING TEMPERATURES. STRUCTURAL NOTES: 1. ALL POOL CONCRETE SHALL DEVELOP A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 2. ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI. 3. ALL DECK CONCRETE (WHEN INSTALLED UNDER THESE PLANS) SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI. 4. THE DESIGN OF THIS PROJECT HAS INCORPORATED A RATIONAL DESIGN APPROACH BASED ON ACCEPTED ENGINEERING PRINCIPALS. 5. ALL REINFORCING STEEL SPLICES SHALL BE 18" IN LENGTH UNLESS OTHERWISE INDICATED ON THESE PLANS. 6. ALL REINFORCING STEEL BENDS SHALL BE BY HAND WITHOUT THE APPLICATION OF HEAT TO THE STEEL. 0 TEE ` SAME SIZE AS PUMP SUCTION Q �5 2� %3NTi�o 0,, �4 /N�'TF -i' C, 2 -� M /N�'�C� 2., 5 HP HEAT PUMP 129,000 BTU POOL FILTER WITH 300 SQ. FT. OF SURFACE AREA CARTRIDGE 1.5" HYDROSTATIC RELIEF TUBE. ONLY ONE REQUIRED , 15 , SQ P NPNG�R os S P P J 5' SP P \NoRP�N 2 �P , �l2 RECIRCULATION PUMP 2 HP, 95 GPM AT 60' TDH SELF PRIMING ISOMETRIC PROVIDE SCREEN MESH `AT JOINT WATER LEVEL WEI R C CERAMIC TILE THROAT POOL WALL , SPA POOL JP OF POOL OR SPA DPING, WHICHEVER HIGHER i To ADJUSTABLE LID CONCRETE BASKET (MIN 75 SQ.IN.) �SUCTION LINE SKIMMER DETAIL ` NO SCALE POOL AND SPA DATA: SWIMMING POOL 35 SURFACE AREA SQ. FT. 493 655 VOLUME GALLONS 14760 TURNOVER HOURS 4 24 PERIMETER FEET 96 top 74,: ` k U.S. Structures, Inc. Structural Engineers -444!- SOUTHWEST 71st AVE, #103 - -. MIAMI, FLORIDA 33155 305.665.4555 FAX 305.665.5522 usstructuresinc.com CA 8439 N O LL_J Q) rr) Cn W � L O O cn LL_ o °) Co O .. ••- O CD 0 O Q 0 c �� Ln c0 U) X Q 4-J Qo 0 yo Ln L_ 00 0 O 4 S� S 1 0 N S: SEAL: r.�t, ;'.. JOSE A: TOLEDO, P.E. STRUCTURAL ENGINEER FL P.E. #54891 D RAIN Ni _ : JAT ; CHECKED 4 -- JAT - DAl E - - August -1, 2005 SCAL-E, - As Inftated - - JOB NO. SDP 05.035.2 SHE-ET - P -2 OF 8 SHEETS