05-1213-004ELECTRICAL NOTES: 1. ALL POOL ELECTRICAL WORK SHALL BE ACCOMPLISHED IN COMPLIANCE WITH FLORIDA BUILDING CODE. 2. ALL ELECTRICAL GROUNDING AND BONDING SHALL CONFORM WITH THE FLORIDA BUILDING CODE. 3. NO OVERHEAD WIRING SHALL BE LOCATED WITHIN 10' -0" OF POOL'S WATER EDGE. 4. SHOULD THE ELECTRICAL RISER DIAGRAM NOT ACCURATELY DEPICT REQUIRED WORK, A REVISED DRAWING SHALL BE SUB- MITTED AND APPROVED SHAOWING EXPECTED AS BUILT CONFIGURATION WITH ADDITONAL SERVICE AND LOAD CALCULATIONS, IF NECESSARY. 5. ALL ELECTRICAL EQUIPMENT NOT SUITABLE FOR EXPOSURE TO THE ELEMENTS SHALL BE ENCLOSED IN A WEATHERPROOF CONTAINER. ALL PUMPS, HEATERS, PIPING AND RELATED POOL EQUIPMENT SHOWN ON THESE PLANS ARE SATISFACTORY FOR EXPOSURE TO THE ELEMENTS. NOTE: PROVIDE #4 BARE COPPER BOND WIRE FROM LIGHT TO POOL STEEL. WHERE A CONCRETE DECK IS NOT PROVIDED, PROVIDE A #4 BARE COPPER BOND WIRE FROM THE POOL STEEL TO THE EQUIPMENT TO THE PANEL. WHERE A CONCRETE SLAB IS PROVIDED, THE BOND WIRE SHALL BE CONNECTED FROM THE POOL STEEL TO THE REINFORCING MESH CONTINUOUS TO THE #5 REINFORC- ING BAR IN THE PERIMETER SLAB FOOTING. A BOND WIRE SHALL THEN BE CONNECTED FROM THE PERIMETER STEEL TO THE EQUIPMENT TO THE ELECTRICAL PANEL. NEW ELECTRICAL PANEL WATTS DESCRIPTION WIRE BRK CIR CIR BRK WIRE DESCRIPTION WATTS 1200 EXIST. PUP 10 30 1 2 30 10 EXIST. ATER HEATER 4500 WATER HEATER = 4500 VA COOKTOP 3 4 RANGE =12000 VA DRYER 12000 EXIST. RANGE 8 40 5 6 30 10 EXISL DRYER 5000 VA SPARES = 2400 VA 7 8 VA A.C.= = 5500 VA 1500 EXIST. 9MALL APPL 12 20 9 10 15 14 EXIST. GEN. UGHT & REC. REMAINDER @ 40% 1500 EXIST. sMALL APPL 12 20 11 12 15 14 EXIST UGHT do RE 1500 EXIST. REFRIGERATOR 12 20 13 14 15 14 EXIST. GEN. UGHT do REC. O 1500 EXIST DISH ASHER 12 20 15 16 15 14 EXIST UGHT do RE In 120 EXIST. GEN. UGHT & REC. 14 15 17 18 15 14 EXIST UGHT do RE 120 EXIST. GEN. UGHT & REC. 14 15 19 20 Qo QCy) 1500 EXIST. ASHER 12 20 21 22 30 10 EXIST. ALL MTD. A/C 500 120 EXIST. GEN. UGHT & REC. 12 20 23 3 24 LC) U) 120 EXIST. GEN. UGHT & REC. 14 15 25 26 20 12 EXIST GEN, UGHT & RE 10750 EXIST. A/c Am 8 40 27 C 28 20 12 EXIST. GEN. UGHT do REC. 29 30 30 10 EXIST. A/c coMp. 5500 5000 POOL HEATER 8 50 31 0 32 33 Z 34 20 12 F.I. OUTLETS 2400 POOL PUP 12 20 35 C 36 20 12 NEW GEN. UGHT & REC. 37 C 38 20 12 . UGHT & REC. 1200 SPARE CIRCtnT 12 20 39 40 15 14 POOL JAC. UGHT 1200 1200 SPARE CIRCUIT 12 20 41 42 _ __ SPACE T MTG;: SURFACE MOUNTED �1OLS 120/240 BUS: 200 P RE y.1- . 3� LOAD. ,: 3 — 3�0 Tr♦ CU. SEE LOAD SUMMARY IN 1 -1/2° CON UIT. ME* 200 ETER/ VAINP I S�1TCH Coveo 20o AMP o.C.F EXIST 0 - - CONDUCTOR , TO REMAIN -- ELECTRICAL LOAD SUMMARY -:TF:i .AF LEA I i ir, 1924 S. F. @ 3 VA = 5772 VA TWO 20 A, SMALL APPL. DISCONNECT SWITCH *3 ® 1500 VA EA. (GFI) = 3000 VA REFRIGERATOR = 1500 VA DISHWASHER = 1500 VA DISPOSAL = 0 VA WATER HEATER = 4500 VA COOKTOP = 0 VA RANGE =12000 VA DRYER = 5000 VA WASHING MACHINE = 1500 VA POOL PUMP = 2400 VA HEAT PUMP = 5000 VA SPARES = 2400 VA SUBTOTAL =44572 VA A.C.= = 5500 VA HT. STRIP @ 100 % =10000 VA AHU FAN = 750 VA FIRST 10 KW ® 100% =10000 VA REMAINDER @ 40% =13829 VA A/C LOAD PER TABLE 220 -30 =10000 VA AHU FAN = 750 VA TOTAL =34579 VA 34579 VA /240 V = 144.1 AMPS 200 A. 120/240 V. 1 PHASE 3 W. SERVICE RATING 3 - 3/0 CU. IN " CONDUIT PROVIDE #4 EQUIPMENT GROUNDING CONDUCTOR INST THGROUDIN N eETE THE GROUND OF THE SERVICE EQUIPMENT. � 200 AMP KP- ELEC. PANEL TO cCwPIN 1/2" ELECTRICAL RISER DIAGRAM SCALE: N.T.S. ELECTRICAL NOTES ALL WORK SHALL COMPLY WITH N.E.C., AND ALL OTHER APPLICABLE CODES AND /OR AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL WIRES, CONDUITS, CONNECTORS, ETC. TO ACHIEVE A COMPLETE ELECTRICAL SYSTEM. WHERE ELECTRICAL EQUIPMENT, OUTLET, OR OTHER FEATURES ARE REQUIRED BY CODE, BUT NOT SHOWN ON THE PLANS, THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL SAME, AS REQUIRED BY CODE. 3. ALL ELECTRICAL WIRES USED SHALL BE ROMEX TYPE. 4. THE ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS, APPROVALS, AND INSPECTIONS. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND PROCURING TEMPORARY POWER DURING CONSTRUCTION ACCESSIBLE TO ALL TRADES. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO CLEARLY LABEL THE CIRCUITS AT THE PANEL WITH THEIR CORRESPONDING AREA CONTROLLED BY THAT CIRCUIT. THESE PLANS CONSTITUTE A COMPLETE SET OF PLANS, THEREFORE NO SECTION STANDS ON ITS OWN. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THIS PLAN WITH ALL OTHER PLANS IN SET, AS WELL HIS ACTUAL WORK WITH ALL OTHER TRADES, TO MINIMIZE CONFLICTS AT THE JOB SITE. EXISTING ELEC. METER TO BE REMOVED AND RELPACED W/ NEW AMP 200 METER DISC/ CO B0. REMOVE LINES AND EXISTING PROVIDE NEW UNDER GROUND ELEC. SERVICE AS REQ'D. FLE( -:TF:i .AF LEA I i ir, SWITCH OJ DISCONNECT SWITCH *3 THREE -WAY SWITCH 11=1 ELECTRIC PANEL SWITCH W/ DIMMER 03 ELECTRIC METER qp DUPLEX RECEPTACLE WP WEATHER PROOF 0 CEILING MOUNTED FIXTURE GFI GROUND FAULTED WALL WALL MOUNTED FIXTURE INTERRUPTER ® RECESSED CEILING FIXTURE FLOOD LIGHT -4J 0 EXHAUST FAN FAN W/ LIGHT _ — wp - -- - - - -- GFI —� - - -- T,o.S. +10.0' NGVD D.S. +10.0' NGw A -36 71 STORAGE ROOM , -36 �- — - -- – -- -j U 4T - GFI �A -38 -7 -3E A -38 A -38 \ 'ROPOSED A -38 \ Acuzzi 1 3 - A -38 38 A -38 A -38 I A -36 ELECTRICAL PLAN SCALE: 1 /4" =1 ' —0" U.S. Structured, Inc. -Structural Engineers 4444 SOUTHWEST 71st AVE, #103 MIAMI, FLORIDA 33155 305.665.4555 FAX 305.665.5522 usstructu resin c.com CA 8439 Q� O ti-- W -4J Q) U W � LC � r � V J 00 •� o W +, (n LL O 00 -C O In 0 In D O O 0- 7; L7 (f) W Qo QCy) 4­1 00 O O a LC) U) R E V I S I 0 N S: 1 09 -15 -05 Q 09 -26 -05 SEAL: JOW-A.,TOLEDj b 4 E 1;: sfRC1CURAL EW6- R FL P—E. #54891' DRAWN JAT CHECKED JAT DATE August 1, 2005 SCALE As Indicated JOB NO. SDP 05.035.2 SHEET E -1 OF 8 SHEETS