Loading...
05-1212(2)-004ELECTRICAL NOTES: 1. ALL POOL ELECTRICAL WORK SHALL BE ACCOMPLISHED IN COMPLIANCE WITH FLORIDA BUILDING CODE. 2. ALL ELECTRICAL GROUNDING AND BONDING SHALL CONFORM WITH THE FLORIDA BUILDING CODE. 3. NO OVERHEAD WIRING SHALL BE LOCATED WITHIN 10' -0" OF POOL'S WATER EDGE. 4. SHOULD THE ELECTRICAL RISER DIAGRAM NOT ACCURATELY DEPICT REQUIRED WORK, A REVISED DRAWING SHALL BE SUB- MITTED AND APPROVED SHAOWING EXPECTED AS BUILT CONFIGURATION WITH ADDITONAL SERVICE AND LOAD CALCULATIONS, IF NECESSARY. 5. ALL ELECTRICAL EQUIPMENT NOT SUITABLE FOR EXPOSURE TO THE ELEMENTS SHALL BE ENCLOSED IN A WEATHERPROOF CONTAINER. ALL PUMPS, HEATERS, PIPING AND RELATED POOL EQUIPMENT SHOWN ON THESE PLANS ARE SATISFACTORY FOR EXPOSURE TO THE ELEMENTS. NOTE: PROVIDE #4 BARE COPPER BOND WIRE FROM LIGHT TO POOL STEEL. WHERE A CONCRETE DECK IS NOT PROVIDED, PROVIDE A #4 BARE COPPER BOND WIRE FROM THE POOL STEEL TO THE EQUIPMENT TO THE PANEL. WHERE A CONCRETE SLAB IS PROVIDED, THE BOND WIRE SHALL BE CONNECTED FROM THE POOL STEEL TO THE REINFORCING MESH CONTINUOUS TO THE #5 REINFORC- ING BAR IN THE PERIMETER SLAB FOOTING. A BOND WIRE SHALL THEN BE CONNECTED FROM THE PERIMETER STEEL TO THE EQUIPMENT TO THE ELECTRICAL PANEL. NEW ELECTRICAL PANEL WATTS DESCRIPTION WIRE BRK CIR CIR BRK WIRE DESCRIPTION WATTS 1200 EXIST. PUP 10 30 1 2 30 10 EXIST. WER HEATER 4500 WATER HEATER = 4500 VA COOKTOP 3 4 RANGE =12000 VA DRYER 12000 EXIST. RANGE 8 40 5 6 30 10 EXIST. DRYER 5000 VA SPARES = 2400 VA 7 8 VA A.C.= = 5500 VA 1500 EXIST. SMALL APPL 12 20 9 10 15 14 EXIST. GEN. UGHT & REC. REMAINDER 0 40% 1600 EXIST. sMALL APPL 12 20 11 12 15 14 EXIST GEN, UGHT & RE =34579 1500 EXIST. REFRIGERATOR 12 20 13 14 15 14 EXIST. GEN. UGHT & REC, 1500 EXIST DISHWASHER 12 20 15 16 15 1 14 EXIST UGHT & RE 120 EXIST. GEN. UGHT do REC. 14 15 17 18 15 14 EXIST UGHT & RE O 120 1 EXIST. GEN. UGHT & REC. 14 15 19 20 Q0 Q 1500 EXIST. WASHER 12 20 21 22 30 10 EXIST. ALL MM. A/C 500 120 EXIST. GEN. UGHT do REC. 12 20 23 3 24 Lo cj� rr) 120 EXIST. GEN. UGHT & REC. 14 15 25 26 20 12 EXIST UGHT & RE 10750 EXIST. A/C AHU 8 40 27 C 28 20 12 EXIST. GEN. UGHT do REC. 29 t2 30 30 10 EXIST. A/& COMP. 5500 5000 E POOL HEATER 8 50 31 32 33 34 20 12 FI OUTLETS 2400 POOL PUP 12 20 35 C 36 20 12 NEW GEN. UGHT & REC. 37 38 20 12 NEW UGHT & REC. 1200 SPARE CIRCUIT 12 20 39 40 15 14 N POOL JAC. UGHT 1 1200 1200 SPARE CIRCUIT 12 20 41 42 -- -- SPACE I -- MM; SURFACE MOUNTED MOLTS 120/240 y,1N Buy 200 P RE; 3 - f 3 0 TH CU' , 3� LOAD: SEE LOAD SUMMARY IN 1 -1/2' CON UIT. OE* 200 ETER/ MAINP I S�ATCH COMBO 2000 AMP O.C.F EXIST GI _ AIN CONDUCTOR TO Rb4- ELECTRICAL LOAD SUMMARY 1924 S. F. ® 3 VA = 5772 VA TWO 20 A, SMALL APPL. D ELECTRIC PANEL *p 1500 VA EA. (GFI) = 3000 VA REFRIGERATOR = 1500 VA DISHWASHER = 1500 VA DISPOSAL = 0 VA WATER HEATER = 4500 VA COOKTOP = 0 VA RANGE =12000 VA DRYER = 5000 VA WASHING MACHINE = 1500 VA POOL PUMP = 2400 VA HEAT PUMP = 5000 VA SPARES = 2400 VA SUBTOTAL =44572 VA A.C.= = 5500 VA HT. STRIP @ 100 % =10000 VA AHU FAN = 750 VA FIRST 10 KW ® 100% =10000 VA REMAINDER 0 40% =13829 VA A/C LOAD PER TABLE 220 -30 =10000 VA AHU FAN = 750 VA TOTAL =34579 VA 34579 VA /240 V = 144.1 AMPS O 200 A. 120/240 V. 1 PHASE 3 W. SERVICE RATING 3 - 3/0 Cu, IN "CONDUIT CONDUCTOR EQUIP ST�TT BETWEEN GROUNDING THE GROOUUI��TGI IN IN OAF THE SERVICE EQUIPVENT. -� NEI ELEC, PANEL TO cCwPIN 1/2" ELECTRICAL RISER DIAGRAM SCALE: N.T.S. WP GFI ELECTRICAL NOTES A -36I � A -36 1. ALL WORK SHALL COMPLY WITH N.E.C., AND ALL OTHER APPLICABLE CODES AND /OR AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT. 2. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL WIRES, CONDUITS, CONNECTORS, ETC. TO ACHIEVE A COMPLETE ELECTRICAL SYSTEM. WHERE ELECTRICAL EQUIPMENT, OUTLET, OR OTHER FEATURES ARE REQUIRED BY CODE, BUT NOT SHOWN ON THE PLANS, THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL SAME, AS REQUIRED BY CODE. 3. ALL ELECTRICAL WIRES USED SHALL BE ROMEX TYPE. 4. THE ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS, APPROVALS, AND INSPECTIONS. 5. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND PROCURING TEMPORARY POWER DURING CONSTRUCTION ACCESSIBLE TO ALL TRADES. 6. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO CLEARLY LABEL THE CIRCUITS AT THE PANEL WITH THEIR CORRESPONDING AREA CONTROLLED BY THAT CIRCUIT. 7. THESE PLANS CONSTITUTE A COMPLETE SET OF PLANS, THEREFORE NO SECTION STANDS ON ITS OWN. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THIS PLAN WITH ALL OTHER PLANS IN SET, AS WELL HIS ACTUAL WORK WITH ALL OTHER TRADES, TO MINIMIZE CONFLICTS AT THE JOB SITE. EXISTING ELEC. METER TO BE REMOVED AND RELPACED W/ NEW AMP 200 METER DISC/ COMBO, LINES AND (PROVIDE NEW UNDER GROUND ELEC. SERVICE AS REQ'D. EEE(= -TR1( =:AE EE( =,'EI 1 CI SWITCH DISCONNECT SWITCH ;3 THREE -WAY SWITCH D ELECTRIC PANEL *p SWITCH W/ DIMMER [33 ELECTRIC METER Q DUPLEX RECEPTACLE WP WEATHER PROOF Q CEILING MOUNTED FIXTURE GFI GROUND FAULTED WALL WALL MOUNTED FIXTURE INTERRUPTER O ® RECESSED CEILING FIXTURE FLOOD LIGHT EXHAUST FAN FAN W/ LIGHT NOTE: GENERAL CONTRACTOR TO COORDINATE EQUIPMENT MOUNTING HEIGHT WITH F.F. ELEV. AND FLOOD ZONE REQUIREMENTS. T.O.S. +10.0' NGVD A -36 GFI STORAGE ROOM A -36 -- GFI –3� ! TOILET --� ,4 WP GFI /�� 0A -38 f A -38 XA - \ 38 ) \ I � A -38 A -38 I D A -36 — _ - T;o.s. +10.0' NGw ELECTRICAL PLAN SCALE: 1/4"= 1 ' -0" US. Structureo, Inc. Structural Engineers 4444 SOUTHWEST 71st AVE, #103 MIAMI, FLORIDA 33155 305.665.4555 FAX 305.665.5522 usstructu resin c.com CA 8439 Q) L O 4-j 0U� ) %/) O W U -C L J—) •� O W 4-' U) LL Q) OO O O E Lo p o O C Ln U' W Q0 Q � � Cfl -� 00 O O Lo cj� rr) R E V I S I 0 N S: 1 09 -15 -05 09 -26 -05 SEAL: JOSE A.- TOLEIJO, -R.E.`" STRUCTURAL- ENGINEEI2' , F�P�E:, #54891 , DRAWN, JAT CHECKED JAT DATE August 1, 2005 SCALE As Indicated JOB NO. SDP 05.035.2 SHEET E -1 OF 8 SHEETS