05-1359(3)-027CAP FOR FUTU ^�
CONNECTION SOb
OR HEAT RECOVEF
3/4"
W�
BALANCING
VALVES
1/2" HOT WATI
RETUI
AQUASTAT
GRUNDFOS IN -LINE RECIRCULATING
PUMP MODEL #: UP15- 18BUC5 /TLC
ALL BRONZE Wr BUILT -IN CHECK
VALVE, 24 HOUR PROGAMMABLE
TIMER, AND AQUASTAT. (120/1/60)
112" HOSE BIBB W /VACUUM
BREAKER (TYP.)
5F'4
�8= OTHERS;
n 4c_ U 7.1111111111111"'11C
II—II I I I I I
C — I �__I' C = =] I —_ =� 1 --
II II _ II C - L = == �1 I I II C — =7 C = =J 1 = I I i!I II II
U_ —
I I !I I I I I I
C -- I r - -1 C --1 C - -J 1 = =—I I-
II
II II III II
C =_Il- II _11_ II II
n U I U Li
II
U II
U
CAP FOR FUTURE
CONNECTION SOLAR
OR HEAT RECOVERY
HEAT TRAP r 1
3/4" P &T
1, RELIEF PIPE
GAP (see note)
AIR GAP
AS REQUIRED ` I
BY CODE
\ AIR GAP ASSEMBLY
WATTS MODEL 909AG
3/4" P &T RELIEF PIPE OR SIMILAR WITH
TO OUTSIDE BUILDING SPLASH GUARD
TERMINATE 6" ABOVE
GRADE
i
WATER HEATER —
NOTE:
GAP SHALL BE AT LEAST
TWICE THE DIAMETER OF PIPE
WATER HEATER PIPING DIAGRA
M AND NEVER LESS THAN 1" r
/-SEE PLUMBING SITE PLAN
SEE PLUMBING SITE f FOR CONTINUATION
PLAN FOR CONTINUATION SEE PLUMBING SITE PLAN SDR 9.3 (SHEET P -1)
(SHEET P -1) FOR CONTINUATION
- 1/2" CW SUPPLY P PE (SHEET P -1) SECOND STAGE. LOWS GAS COCK 1/2 "' HOSE
- -� -- = PRESSURE REGULATOR
1/2" - - -- SDR 93 GAS COCK
1/2" SHUT -OFF SECOND STAGE. LOW G GAS FOR BBQ ,
VALVE IN VERTICAL PRESSURE REGULATOR (40,000 BTU /H)
1/2" CW G -
_�___�_ I I FOR ICE
EHD -31
112" REF BBQ ICE
ICOVERED
2 C41z C-sARACxE 112 ",i _ FAMILI' G
ql� TERt2ACE ROOM BREAKFAST �
I
I
I I
I I
I I
_ ® i END -31
1/2" HOSE BIBB W /VACUUM 17'-1" G ,--- --- - - - -_-
BREAKER (TYP,) \
r `
1/2" ;CW'
DOWN POR
' REFRIGERATOR
I
I I
REF
25' -4„ I
IG— G
IEHD -3 ' I _
I_ g DW
L—
I I I
I 0 I -
o SK l\ KITCHEN
I
D -31 1
1 , „
` I
9-1 G --- - - - - --
I
- -- _ - x112" 3/4" �
4_
3/4" CW, 3/4" HW & - �
112" HWR PIPES UP TO -
- - - -- \.J J-- --- - - -__J
ED SECOND FLOOR BATH EHD -31
5' -11" ---- GAS FOR COOKTOP AND
- - - - -- -OVEN (170,000 BTU /H)
1 r-- - - - - -- I 1
I I - I I
I I I I I
I I I I I
I I I
I I I
I I I
I I I I I
I I I I I
I I I I I
I I I I I
SUJIMh�11NC -c pp�, I I I I I
I I I I I
<BY OTN RS) COVERED � � LIvINn Room
I I I I
TESF,4CE
I I I I I
I I I I I
I I I I I
I I t I I
I I I I I
I I t I I
I I I I I
I I I I I
I I I I I
I I I
I I
I I
j - - -- 3/4" CW & 1/2" HW
N.T.S.
GWH:
GAS WATER HEATER "LOCHINVAR" (OR APPROVED EQUIVALENT) POWER
DIRECT VENT MODEL NO. SRL075, 6.OKW, 240/1/60. RECOVERY 75 GPH AT
90OF RISE. STORAGE 75 GAL. GLASS -LINED TANK, 10 YEAR WARRANTY.
ENERGY FACTOR (EF) 0.48
tAj
i^
11
L
WC 1/2"
BATH /2"
I '
I
I
1/2 "-
SH
112" HOSE BIBB W /VACUUM --
BREAKER (TYP.)
-1/2"
GU =ST
BEDROOM
/ SEE PLUMBING SITE PLAN
fFOR CONTINUATION
(SHEET P -1)
I 1 1/4" CW SUPPLY PIPE
E LBIBBW/VACUUM P.) 1! r- 1 -1/4" SHUT -OFF
VALVE IN VERTICAL
,
I
------ - - - - --
I '
L---- ---------- -�
------ - - - --,
FANTRT
1 1/4"
I 1
I I
I I
I 1
I I I I
I I I I I
I I I t I
li i I DINING
i I I ROOO_'I
I I f I I
I I I I
I I I I
I 1
� I I
11/4 "-�I I I
I I �
I I I
I I �
GAS DOWN FOR
WATER HEATS - - --
' I (70,000 BTU /H) IN -LINE
RECIRCULATING
G 1/2" PUMP
EHD -31 - -- - -- "" _ _ ---
WINE/ r4 uuu i
1/2 STOF„4GE GWH I
W
1/2„ 1 ------ - - - - --
" 1 Il7 3/4"
1 1/2" L (o �
/2" (L
- - - - -- '1/
- -Yt r v2"
-- - - - - - - I It WC
1I}1'
) I IOIUD
ROCM -- - - - -__
Q----------- - - -T�-
, 1
, 1
I I
I I I
�I I
I I I
I I 1
FOYER
I I I I
3/4 ") ,� 3/4" CW & 1/2" HW
PIPES UP TO SECOND '
112' I I i FLOOR BATH
I I I I
PIPES UP TO SECOND I i
FLOOR BATH - - - - - - - 1,
FIRST FLOOR UJ4T N
SCALE : 1/4' 1' -oil I �l ��,
3/4" 1/2'1 ,
3/4"
1/2"
,-�- LS
I �
I
LAU —NDRy
' Roots
I
I j
I
� I
I
I
I
I
I �
A/C
i
�� L \ B,4TN �l
w WC
C - -
I
I
DI C
C— S H
MAID'S
3EDROO1 -1
1/2"
1/2" HOSE BIBB W /VACUUM J
BREAKER (TYP.)
3/4" P &T RELIEF VALVE PIPE
TO OUTSIDE BLDG. TERMINATE
6" ABOVE GRADE
I . .
I
I
I
I
I
Eh_
I
I
I
I
I
1
I
I
I
I
I
'T - - --
PLANS ARE PROTECTED UNDER THE COPYRIGHT LAWS pp FLORIDA:
ALL RIGNTS RESERVED
CONTRACTOR SHALL VERIFY AIID BE RESPONSIBLE FOR ALL MMENSlONS AND CONDRpN3 q,, THE
JOB. THE DESIGN PROFESSIONAL MUST BE NOTIFIED IN WRITING OF ANY VARIATION DFT)C THE PLANS, FROM ALL IDEAS DESIGN ARRANGEMENTS AND PL 431NDICATEO OR REPRESENTED BY THIS DRA"INGS ARE
OWNED ,AN D THE PROPERTY OF THE DESIGN PROFESSIONAL ANp WERE CREATED EWLVEDµp
CEVEIOPED FOR ON AND IN CONNECTI_V1 7H THE SPECIFIED PRQIECT ANY Ci'l°NGF.S 70 THESE
PLANS W7TNOUT THE WRITTEN APPROVAL .11 HE DESIGN pROFESSI
EXECUTED FROM THESE PLANS iMTHOUT EXPRESSED APPROVAL OF TVIE pB3,ESiKy1AL
GROUP, PAOMHARMLESS TO ANY L THE D I' IGN MS, SU T OR IL TIGg= BY ANYEERW ESTE PD P TING
OF THE PROJECT. NO PART THEREOF OF THESE PLANS SHALL BE CORED OR REPRODUCED BYµY
MEANS, OR USED IN CONNECTION WITH µY WORK OTHER THMi FOR THE SPECIFIC PROJECT FOR
WHICH THEY HAVE BEEN PREPAREDVNTHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL
THE ENGINEERING
CONSULTING GROUP, P.A.
CA. SM MECHANICAL, ELECTRICAL, PLUMBING, 8
FIRE PROTECTION ENGINEERING DESIGN c • • • • c ° ° t,.� ��t
0R>--
Fax
E-mail
Address
Ernesto Rodriguej -
•
Mechanical Engineef
(305) 6633191 P.E. # 58155,
(305)663 -8788 ICJ
tec910uP@tecprGup -pa corn - •" • .`� L�I.p�K"°� `,'
5001 S W. 74 CT, Sufte 204, Miami FL 33155
o
0
o
I
C co
O O Ij
00 L0
O U
a 0
H
to
rU� z "�
h� � p :'o
o
U
r�
0
Cv
co
dr
Ln 0
1�
Q/,
O
CMp
Z
w
W
1.4
co
O
a.
O
a
cc
Lk Ild
O
C\2
U
z�
E-,
.O
CO
wwh--1
E,
sheet
w
waMc
E" CO
00 CO d4
d'
..
z
.
z
o
z
a°�a
N
E
CD
u
a
0
c
J
m
O
'^
0
O a
Ln 0
1�
Q/,
CMp
Z
W
W
XY6�--11
U
c�
.O
s.
sheet
no.
F94
4 of 5