Loading...
04-52-059c I I Z Q 0 4 Q O O CU M m Cu Co T 3 (D a �o Q m 0 / aT , C W O Q ti m � O / cD C, 3 O we GENERAL PLUMBING NOTES: 1. A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code and with all applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the plumbing work. C. ARRANGE AND PAY for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. E. ALL HORIZONTAL SANITARY PIPING 2' or smaller shall slope at 1/8" per foot minimum, 3" or larger shall slope at a 1/4" per foot minimum. 2. SHOP DRAWINGS: Contractor shall submit for approval, within 30 days of signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: water heaters, drains, piping and plumbing fixtures. No work shall proceed without the approval of these submittals. 3. PLUMBING FIXTURES: Fixtures shall be as specified and shall be furnished and installed by this contractor. Fixtures shall be complete with drains, traps, supplies and any other accessary required. 4. MATERIALS: A. PIPING a. il, waste and vent, and storm: Sanitary pipe, Hubless cost iron pipe fittings. b. Domestic water. Copper pipe, Type L with sweat wrought copper fittings. Type "M" in concealed spaces is acceptable. Isolate piping from concrete with insulating material. cpvc in apartments water distribution is acceptable as per owners request. c. Condensate drain: DWC PVC, except use DWV Copper pipe and fittings in a/c closets. d. Domestic water supply assembly. Chrome finish tubing with angle shut off valves. 5. ALL AUTOMATIC electric water heaters shall meet the standards of the latest energy efficiency code. 6. PIPING TEST AND DISINFECTION& A. Test: All sanitary and domestic water supply piping shall be tested for leaks before piping is concealed or connected to equipment and plumbing fixtures. B. Disinfection: All domestic water piping shall be disinfected by introducing a solution of calcium hypochlorite of 50 parts per million of chloride and as per AWWA Standards. 7. VALVES: Domestic water valves shall be of bronze body, sweat ends. 8. HOSE BIBBS: Shall be rough brass construction with shut off valve and vacuum breaker. 9. ALL OUTDOORS FLOOR dean outs shall be terminated up to grade and shall be marked 10. CONTRACTOR SHALL COORDINATE exact location of sanitary, and domestic water piping before starting any work. Notify Architect/Engineer of any deviations from design drawings. 11. CONTRACTOR SHALL PAY for any engineering services related to the revision of drawings as a result of any changes originated by the contractor. NOTE: Refer to book specifications for additional specifications. PLUMBING SYMBOL LEGEND FUSED DISCONNECT GATE VALVE TRENCH DRAIN SWITCH IN DRY AREA CHECK VALVE GROUNDED PLUG c ,• c ..• c 4" c.. c c v UNION v :.v- TO DRAINAGE SYSTEM . 4. ' . (SEE PLAN FOR SIZE) V MICRO PRESSURE SWITCH--------'.-,*. v V 18" X 18" WITH ADJUSTABLE CLAMP ; ' v :. v '; SUMP PIT :. 2" DISCHARGE r VENTED CABLE . � v v f. v 5 3/4' . • PUMP ' .v • ; MICRO PRESSURE OFF SWITCH 2' f v C ` ti c c •; •'v F �••c c'�;' c •,;' .•`, .c •c •,.'c .' ..e'ti;' ,•c• ,c .c �.c'.' c c c SUMP PUMP STRAINER SUMP PUMP DETAIL N.T.S. SUMP PUMP: ARMSTRONG SERIES 5310, MODEL 5310 -50, 1/2 HP, 115V/10, 50 GPM @ 25 FT TOTAL HEAD. COMPLETE WITH CONTROL PANEL SIMPLEX MODEL 112 WITH ALL ACCESSORIES REQUIRED FOR AN AUTOMATIC OPERATION. DRAIN SCHEDULE SYMBOL DESCRIPTION MANUFACTURER / MODEL SANITARY LINE — — VENT LINE SD STORM DRAIN LINE —� —� SAFEWASTE LINE D DRAIN PAN RISER R RELIEF LINES CD CONDENSATE LINE - COLD WATER LINE — - - — HOT WATER JOSAM 76701 1 _DP— DIN DRAIN PAN DRAIN LINE P -3A FIR FC❑ FLUSH CLEAN OUT FD FLOOR DRAIN Co CLEAN OUT VTR VENT THRU ROOF RWL RAIN WATER LEADER —pa— GATE VALVE P- PLUMBING FIXTURE 1/2" DESIGNATION DW FLOOR PENETRATI ❑N 1" IW 1 FI� WATER HAMMIER ARRESTOR C❑ ❑G CLEANOUT ON GRADE WH WALL HYDRANT HB HOSE BIBB W/ SHUT -OFF VALVE W AND VACUUM BREAKER AAV AIR ADMITTANCE VALVE AD AREA DRAIN PD PLANTER DRAIN SA SHOCK ABSORBER ED) CONDESATE RISER eRELIEF RISER ePAN DRAIN RISER eWATER RISER eSANITARY RISER FUSED DISCONNECT GATE VALVE TRENCH DRAIN SWITCH IN DRY AREA CHECK VALVE GROUNDED PLUG c ,• c ..• c 4" c.. c c v UNION v :.v- TO DRAINAGE SYSTEM . 4. ' . (SEE PLAN FOR SIZE) V MICRO PRESSURE SWITCH--------'.-,*. v V 18" X 18" WITH ADJUSTABLE CLAMP ; ' v :. v '; SUMP PIT :. 2" DISCHARGE r VENTED CABLE . � v v f. v 5 3/4' . • PUMP ' .v • ; MICRO PRESSURE OFF SWITCH 2' f v C ` ti c c •; •'v F �••c c'�;' c •,;' .•`, .c •c •,.'c .' ..e'ti;' ,•c• ,c .c �.c'.' c c c SUMP PUMP STRAINER SUMP PUMP DETAIL N.T.S. SUMP PUMP: ARMSTRONG SERIES 5310, MODEL 5310 -50, 1/2 HP, 115V/10, 50 GPM @ 25 FT TOTAL HEAD. COMPLETE WITH CONTROL PANEL SIMPLEX MODEL 112 WITH ALL ACCESSORIES REQUIRED FOR AN AUTOMATIC OPERATION. DRAIN SCHEDULE SYMBOL SERVICE MANUFACTURER / MODEL COLD WATER HOT WATER REMARKS F.D. FLOOR DRAIN JOSAM 30000- 5S -2 -50 AD AREA DRAIN JOSAM 23000- 50 -1 -30 (HEEL PROOF TOP) FD -1 FLOOR DRAIN (MECH. ROOMS) JOSAM 32120 -50 GO GARAGE DRAIN JOSAM 32320 -7 -17 TO TRENCH DRAIN JOSAM 76701 PERFORATED-"' VENT CAP 12' MIN. SLOPE 1/8'/ FT. I AC UNIT L- 3' UNION CONDENSATE TRAP DETAIL (APARTMENTS) N.T.S. FIXTURE CONNECTION SCHEDULE (RESIDENTIAL) MARK DESCRIPTION WASTE COLD WATER HOT WATER REMARKS P -1 WATER CLOSET 3" 1/2" - -- SELECTION BY OWNER P -2 LAVATORY COUNTER 1 1/2" 1/2" 1/2" SELECTION BY OWNER P -3 BATHTUB (NOTE 2) 1 1/2" 1/2" 1/2" SELECTION BY OWNER P -3A ROMAN BATHTUB (NOTE 2) 1 1/2" 1/2" 1/2" SELECTION BY OWNER P -4 SHOWER 1 1/2" 1/2" 1/2" SELECTION BY OWNER P -5 SINK 2 COMP /DISP. 1 1/2 1/2" 1/2" SELECTION BY OWNER DW DISHWASHER 1" IW --- 1/2 SELECTION BY OWNER REF REFRIGERATOR - -- 1/2" - -- SELECTION BY OWNER W WASHER 2" 1/2" 1/2" SELECTION BY OWNER NOTE: 1. RESIDENTIAL FIXTURE & TRIM SELECTION BY OWNER. CONTRACTOR TO INCLUDE COST OF FIXTURES IN THOR BID. 2. SHOWER VALVE SHALL BE OF THE ANTI - SCALD, PRESSURE COMPENSATING TYPE. 3. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH THE FLORIDA BUILDING CODE WATER CONSERVATION REQUIREMENTS 3/4" HEAT MARK TRAP CAPACITY HOT WATER TO SYSTEM. f— P & T RELIEF - VALVE. ELECTRIC WATER HEATER SHELF -COLD WATER SUPPLY — SHUT -OFF VALVE —HEAT TRAP —WATER SUPPLY TO HEATER. P & T RELIEF LINE FULL SIZE /--AIR GAP FITTING (JOSAM 88910) 3/4" TO OUTSIDE, TERMINATE POINTING DOWN 6" ABOVE GRADE. RAIN VALVE " �u�GALV. STEEL PAN W/� " 1 PAN DRAIN ALL SOLDERED SEAMS, 2 TO OUTSIDE, TERMINATE CLEAR ALL AROUND HEATER., POINTING DOWN 6" 24 GA. MIN. 1 1/2" HIGH ABOVE GRADE. TYPICAL SHELVED WATER HEATER DETAIL N.T.S. FIRE SAFING DETAILS PENETRATION FIRESTOP FOR 3" MAX. DIAM. INSULATED METAL PIPE THROUGH A CONCRETE FLOOR, 1" MIN. DEPTH OF 3M FIRE BARRIER MOLDABLE PUTTY. 4 1/2" SOLID MIN. CONC. SLAB. ANNULAR SPACE. ••d • . a' 3" MAX. DIA. METAL PIPE 3M UL SYSTEM #203 TRAP PRIMER FITTING LAVATORY WASTE 1" MIN. PACKING MATERIAL 1" MAX GLASS FIBER PIPE INSULATION. " "ORY IROME PLATED IPPLY (SPEED WAY Z EQUAL) OME PLATED UTCHEON LINE MUST PE TO TRAP PENETRATION FIRESIDE FOR MULTIPLE INSULATED METAL PIPE THROUGH A CONCRETE WALL, COPPER OR STEEL �7 MINERAL WOOL PIPE / _ PACKING. FLEXIBLE FOAM ORS SOLID CONCRETE GLASS FIBER R BLOCK WALL INSULATION. 1" DEPTH OF 3M 3M FlRE BARRIER il FIRE BARRIER FS -195 WRAP /STRIP. CP 25 CAULK. 3M UL SYSTEM j 152 ^OR DRAIN SH FLOOR FLOOR DRAIN TRAP RESEAL DETAIL N.T.S. ELECTRICAL WATER HEATER SCHEDULE MARK LOCATION CAPACITY KW. OR BTUH E.F. VOLTAGE MANUF'R. & MODEL j k GALLONS MIAMI, FL. 33155 UNITS 5, 6 & 7 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 EWH -1 (3 BEDR. & 2 1/2 BATHR) 47 5.5 KW 0.88 MIN. 208V / 10 LOCHINVAR ESJ50KK UNITS 1, 2 & 3 EWH -2 (2 BEDR. & 2 1/2 BATHR.) 40 4.5 KW 0.88 MIN. 208V / 10 LOCHINVAR ESJ40KK UNITS 4 EWH -3 (2 BEDR. & 2 1/2 BATHR.) 40 4.5 KW 0.88 MIN. 208V /10 LOCHINVAR ESJ40KK 3/4" HEAT COLD WATER SUPPLY TRAP SHUT -OFF VALVE HOT WATER TO HEAT TRAP SYSTEM. f— WATER SUPPLY P & T RELIEF TO HEATER. VALVE. P & T RELIEF LINE FULL SIZE ELECTRIC WATER AIR GAP FITTING O=MT7 HEATER (JOSAM 88910) DRAIN VALVE TO OUTSIDE, TERMINATE POINTING DOWN 6" ABOVE GRADE. FLOOR GALV. STEEL PAN W/ ALL SOLDERED SEAMS, 2" CLEAR ALL AROUND HEATER., 24 GA. MIN. 1 1/2- HIGH (UNIT 04 ONLY) TYPICAL FLOOR MOUNTED WATER HEATER DETAIL N.T.S. c ' . r � RAF P JOB NO. 03.140 JCHAS & ASSOCIATES, PA ARCHITECTURE PLANNING INTERIORS 4361 S.W. 11 TH STREET Miami, Florida 33146 TEL: (305) 989 3149 FAX: (305) 447 1501 JACHASTANET @ aol.com A R 0 0 1 2 6 1 1 OWNERS: PALMS OF SUNSET J.V. 5835 Blue Lagoon Drive, Suite 200 Miami, Florida 33126 T 786.275.8480 F 786.275.8474 V rW V ) O LLI q + � r Z Uj � M C0 a 0 w O� o ti0 ZW Q U) O 000 0. LO O DATE: 12 -14 -03 REVISIONS: A 03 -16 -04 BLDG. DEPT. REVISION 02 05 -25 -04 BLDG. DEPT. REVISION PROJECT No. 03 -060 DRAWN BY: CHECKED BY: RPJ SCALE: AS SHOWN SHEET No. J RPJ, I nc. Corteift Erb STATE OF FL CO. NO. (00006513) P E. NO. (16395) k 4977 S.W. 74th COURT MIAMI, FL. 33155 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 JCHAS & ASSOCIATES, PA ARCHITECTURE PLANNING INTERIORS 4361 S.W. 11 TH STREET Miami, Florida 33146 TEL: (305) 989 3149 FAX: (305) 447 1501 JACHASTANET @ aol.com A R 0 0 1 2 6 1 1 OWNERS: PALMS OF SUNSET J.V. 5835 Blue Lagoon Drive, Suite 200 Miami, Florida 33126 T 786.275.8480 F 786.275.8474 V rW V ) O LLI q + � r Z Uj � M C0 a 0 w O� o ti0 ZW Q U) O 000 0. LO O DATE: 12 -14 -03 REVISIONS: A 03 -16 -04 BLDG. DEPT. REVISION 02 05 -25 -04 BLDG. DEPT. REVISION PROJECT No. 03 -060 DRAWN BY: CHECKED BY: RPJ SCALE: AS SHOWN SHEET No. J