04-52-047a w Cr w M O O CU LC7 u7 m Cu U QJ 0 3 T3 Q U a 0 v m 0 W O Q u m 0 / co 3 O TURNING V4 FOR SMACNA STANDARDS. I.....Ii TYPICAL 90- DEGREE VANED ELBOW DETAIL. WOOD JOIST & DECK. HANGER WIRE 12 GAUGE (MIN.) SCREWS FASTENERS. DUCT SHEET METAL CHANNEL SUSPENDED CEILING (SEE ARCH. DRAWINi DUCT HANGER DETAIL N.T.S. HVAC SYMBOL LEGEND SYMBOL DESCRIPTION ® SUPPLY DUCT DESIGN MANUFACTURER RETURN /EXHAUST DUCT IIIIIIII FLEXIBLE DUCT ACCESORIES ELBOW W/ TURNING VALVES REF. S &R REFRIGERANT SUCTION & LIQUID LINES CEILING DIFFUSER CEILING EXHAUST FAN TITUS 250 -AA EXHAUST REGISTER OCOOLING THERMOSTAT O.B.D. X: AIR DEVICE TYPE AX B OX # CFM # - -- TITUS 4FL AXB: NECK SIZE SA SUPPLY AIR RA RETURN AIR EA EXHAUST AIR CU CONDENSING UNIT 4"' AFF ABOVE FINISH FLOOR CFM CUBIC FEET PER MINUTE FCU FAN COIL UNIT EF EXHAUST FAN CONDENSING UNIT 6" M IN. --� FASTEN C.U. TO CONCRETE - PAD USING (4) 1/4" CONCRETE SCREWS WITH 1.5" EMBEDMENT MINIMUM AS PER MFG. CERTIFIED DATA. PROVIDE (4) 1/2" ISOMODE PADS AT EACH SCREW CONCRETE BASE W/ 6X6- 10 /10WWF 6" MIN. ' SEAL ENTRANCE OF REFRIGERANT LINES INTO P.V.C. PIPE W/ IMPERMEABLE, RESILIENT MATERIAL NOTE: CONCRETE CREWS SHALL BE RATED FOR 500 LBS. MIN. PULL -OUT CAPACITY. UNIT A DRAIN NEOPR METAL TYPICAI RETURI FLOOR 1 1/2" X 26 GA. GALV. STEEL HANGER STRAP (5' O.C.) AIR DUCT (SEE PLAN VIEW) LOW FRICTION LOSS BRANCH TAKE -OFF FITTING METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY SEAL JOINT W/ DUCT SEALER AND 6' MAX. TAPE AIR FLOW INSULATE TOP OF DIFFUSER. DIFFUSER W/ OPPOSED BLADE DAMPER ADAPTOR ROUND TO SQUARE IF REQUIRED SUPPORT FROM UNDERSIDE OF STRUCTURE. AIR FLOW INSULATED FLEX. DUCT BAND OF SAME SIZE AS HANGER STRAP SEAL JOINT WITH DUCT SEALER AND TAPE FLEXIBLE DUCT CONNECTION DETAIL N.T.S. POWER & CONTROL CONNECTIONS 6" MIN. 4" MIN. CONDENSING UNIT MOUNTING DETAIL N.T.S. STRUCTURE OF FLOOR ABOVE SUPPLY AIR DUCT DISCONNECTED SWITCH FAN SECTION FAN COIL UNIT TO BE MOUNTED WITH WALL METAL SHELVES. REFRIGERANT PIPES FROM COND. UNIT COIL SECTION AUX. FLOAT SWITH.% FLOAT SWITH SHALL STOP FAN COIL UNIT IF INDICATED. FAN COIL UNIT MOUNTING DETAIL N.T.S. (TYPICAL RESIDENCE UNIT) NOTE: NO COMBUSTIBLES ALLOWED IN A/C CLOSET. LIQUID LINE W/O INSULATION PVC SCH.40 PIPE SIZED 2" LARGER THAN THE PIPE AND INSULATION ENCASED. (4 "0 1A MIN.) SUCTION LINE W/ 1/2" ARMAFLEX INSULATION & VAPOR BARRIER NOTES, DETAILS, SCHEDULES - HVAC_ SC4LE:NiS. 'BIBhii COORDINATE WITH PLUMBING CONTRACTOR FOR WATER HEATER ELEVATION. HVAC NOTES 1. GENERAL A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code and with all applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the HVAC work. C. ARRANGE AND PAY for all permits licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. Compressors shall be guranteed for a period of five years. E. As built drawings shall be submitted to owner at the completion of project. 2. SHOP DRAWINGS: Contractors shall submit for approval, within 30 days after signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: fans, air conditioning units, air outlets. No work shall proceed without approval of these submittals. 3. DESIGN PARAMETERS: A. Outdoor design temperature (Summer): 917 DB and 797 WB B. Outdoor design temperature (Winter): 45'F C. Indoor design temperature (Summer): 787 DB D. Indoor design temperature (Winter): 727 DB 4. ALL THERMOSTATS SHALL have heating mode maximum setting of 75 F, and cooling mode minimum setting of 70 F. The thermostat shall be arranged to prevent the simultaneous operation of heating and cooling. 5. ELECTRICAL CONTROLS AND POWER WIRING: Under electrical contract. 6. EQUIPMENT SPECIFIED BY manufacturer's number shall include all accessories, controls, etc., listed in the catalog as standard with the equipment. Optional or additional accessories shall be furnished as specified. 7. MATERIALS: A. REFRIGERANT PIPING: Shall be type L soft drawn, copper tubing, dehydrated for refrigerant use. Sized as shown on drawings or as per air conditioning equipment manufacturer's recommendations. B. INSULATION: Refrigerant suction piping shall be insulated with 1/2" thick foamed plastic insulation, fire retardant type. Insulation shall be installed in piping before assembly. No split insulation will be acceptable. Seal joints with manufacturer's approved adhesive and grey tape. C. DUCTWORK: a. All supply air ductwork shall be fiberglass ductboard, fabricated and installed as per latest edition of SMACNA "Fibrous Glass Duct Manual ". 1 -1/2" thick R -6.0 in uncond. space. 1" thick R -4.2 in cond. space. b. All exhaust ductwork shall be galvanized sheet metal duct not lighter than 26 gage. c. All duct dimensions are clear inside dimensions. d. Flexible insulated ductwork with 1 1/2" thick fiberglass insulation with FRK vapor barrier, class I air duct, U.L. R -6.0 MIN. e. Dryer ductwork: 26 ga. min. galvinized steel, having a smooth interior surface with joints running in the direction of airflow and without sheet metal screws or other fastners in the air stream. Maximum length shall not exceed 25 feet. wall caps shall be provided with backdraft damper. 8. Provide metal round fittings with scoop at all flexible duct connection to supply duct. 9. TEST AND BALANCE: Contractor shall test and balance all ventilation and air conditioning systems. Submit four copies of Test and Balance Report to owner for approval. 10. CONTROLS: Air conditioning units shall be started and stopped thru individual thermostat. Individual thermostats shall start /stop supply fans and activate cooling /heating systems as selected. 11. Mechanical plans in general, are diagrammatic in nature, and are to be read in conjuction with arch. Plumbing, electrical and structural plans and shall be considered as one set of documents. Duct and piping offsets, bends and transitions will be required to provide and install a complete functional system and shall be provided by the contractor at no additional cost to the owner. 12. Contractor shall verify job conditions prior to ordering, fabrication or installation of materials or equipment. Notify architect /engineer of any conflicts before fabrication. AIR DISTRIBUTION SCHEDULE UNIT DESIGNATION UNIT DESIGNATION FCU -1 FCU -2 DESIGN MANUFACTURER SIMBOL USE TYPE ACCESORIES & MODEL Mo. OSUPPLY AIR CEILING DIFFUSER O.B.D. TITUS 250 -AA OB SUPPLY AIR WALL REGISTER O.B.D. TITUS 272FS (D RETURN AIR WALL / CEILING - -- TITUS 4FL DESIGN MANUFACTURER RHEEM REGISTER RHEEM RHEEM OL EXHAUST AIR WALL LOUVER ALUMINUM BIRDSCREEN RUSKIN 4O NOTE: 1. ALL AIR DISTRIBUTION DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION. 2. COORDINATE COLOR FINISH WITH ARCHITECT, WHITE BAKED ENAMEL STANDARD. 3. ARROWS INDICATE DIRECTION OF AIR DISTRIBUTION. 4. DADE COUNTY APPROVED. SPLIT A/C UNIT SCHEDULE UNIT DESIGNATION UNIT DESIGNATION FCU -1 FCU -2 FCU -2A FCU -3 TOILET AREA SERVED UNITS 4 UNITS 1,2,3 UNIT 1 UNITS 5,6,7 LOCATION LOCATION A/C CLOSET A/C CLOSET A/C CLOSET A/C CLOSET CLG. EXHAUSTER OPERATING WEIGHT 92.0 92.0 109 109.0 4200 DESIGN MANUFACTURER RHEEM RHEEM RHEEM RHEEM MODEL NO. RBHC17J11SFG RBHC17J11SFH RBHK21511SFC RBHC21JIlSFG FAN TIP SPEED, FPM MAX. EER, MIN. 12.0 12.0 13.60 12.0 - -- - -- TOTAL AIR, CFM 1000 1200 1200 1400 0.375 MCA /MOCP 38.4/48.0 38.4/48.0 38.4/48.0 38.4/48.0 FAN MOTOR STARTER TYPE Z L":Lr EXT. STATIC PRESS., INCHES OF H2O 0.4 0.4 0.4 0.4 - -- MECH. CONTRACTOR FAN MOTOR H.P. (NON - OVERLOAD) 1/4 1/4 1/2 1/3 MASONARY OPENING REQUIRED ELECTRICAL SERVICE AVAILABLE 208/1/60 208/1/60 SCALE: 208/1/60 0.3 0.6 FACE VELOCITY, FPM -- -- -- -- Z D a DESIGN AIR ACROSS COIL, CFM 1000 1200 1200 1400 o U z TQTAL-CAPACI , BTUH 28,400 34,000 36,200 41,000 Z GRAND o TO LL SENSIBLE BTUH 20,800 24,800 26,400 29,900 / ALUM /PLASTIC ALUM /PLASTIC _CAPACITY, 0: 0 MULTIBLADE BACKDRAFT DAMPER YES YES LZ ov EN RING AIR TEMP. OF DB /WB 80/67 80/67 80/67 80/67 SOLID STATE SPEED CONTROL NO COIL MODEL NO. RCHA -36A1 RCHJ -36A2 RCGJ -36A2 RCHA -48A2 NO NO FILTER TYPE & THICKNESS PERM & WASH PERM & WASH PERM & WASH PERM & WASH FILTER AND FILTER FRAME NO NO NO QUANTITY AND SIZE (1)19.75X21 (1)16.25X21 (1)19.75X21 (1)19.75X21 FACE VELOCITY FPM. MAX. HEAT /REHEAT COIL TYPE ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL Of W ELECTRICAL SERVICE AVAILABLE 208/1/60 208/1/60 208/1/60 208/1/60 = AUXILIARY ELECTRIC HEAT, KW 7.3 7.3 7.3 7.3 STAGES AND KW /STAGE 1/7.3KW 1/7.3KW 1/7.3KW 1/7.3KW UNIT DESIGNATION CU -2 CU -1 CU -2A CU -3 TYPE OF FAN PROPELLER PROPELLER PROPELLER PROPELLER ~ Z NO. OF FANS AND FLA 1 -1.3 FLA 1 -2.0 FLA 1 -2.0 FLA 1 -2.0 FLA D o AMBIENT AIR TEMP., ODB 95' 95' 95' 95' Z in CONDENSING TEMP., '�7 DB -- -- -- -- o NO. OF COMPRESSORS 1 1 1 1 Z 0 0 COMPRESSORS RPM MAX. -- -- -- -- W CAPACITY REDUCTION 0 -100% 0 -100% 0 -100% 0 -100% 0 MCA /MOCP 19/30 23/35 23/35 27/45 a ELECTRICAL SERVICE AVAILABLE 208/1/60 208/1/60 208/1/60 208/1/60 OPERATING WEIGHT,LBS. 169 185 185 255 DESIGN MANUFACTURER RHEEM RHEEM RHEEM RHEEM MODEL NO. RAMB030JAZ RAMS036JAZ RAMB036JAZ RAMB042JAZ REFRIGERANT LINE SUCTION & LIQUID 3/4 " -1/4" 3/4" -5/16" 3/4" -5/16" 1 -1/8" - 5/16" NOTES: 1. ALL FAN COIL UNITS SHALL BE PROVIDED WITH FACTORY INSTALLED CIRCUIT BREAKER. 2. ALL THERMOSTATS SHALL BE PROGRAMABLE TYPE. VENTILATION FAN SCHEDULE UNIT DESIGNATION EF -1 EF -2 GEF -1 AREA SERVED TOILET TOILET BASEMENT PARKING OPERATING WEIGHT, LBS 15 17 275 LOCATION CEILING CEILING CEILING FAN TYPE CLG. EXHAUSTER CLG. EXHAUSTER IN LINE EXHAUSTER SMOKE CONTROL TOTAL AIR, CFM 50 80 4200 DRIVE TYPE DIRECT DIRECT DIRECT FAN WHEEL TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL 0� FAN TIP SPEED, FPM MAX. - -- --- --- ILL FAN SPEED, RPM - -- - -- - -- Z TOTAL STATIC PRESSURE, IN OF WATER 0.1 0.1 0.375 FAN MOTOR HP. (NON- OVERLOAD) 0.7 AMPS 1.1 AMPS 1.0 AMPS , FAN MOTOR STARTER TYPE WALL SWITCH WALL SWITCH MOTOR RATED SWITCH STARTER FURNISHED BY - -- - -- MECH. CONTRACTOR 03 -060 ELECTRICAL SERVICE AVAILABLE 120 -1 -60 120 -1 -60 208 -1 -60 MASONARY OPENING REQUIRED - -- - -- - -- SCALE: ZONES 0.3 0.6 0.6 DESIGN MANUFACTURER BROAN BROAN COOK MODEL NUMBER S50U S80U 180SQI -B SERVICE SWITCH YES (WALL) YES (WALL) YES SMOKE DETECTOR ( U.L. APPROVED) NO NO NO FIRE DAMPER - -- - -- - -- w CONSTRUCTION ALUM /PLASTIC ALUM /PLASTIC GALV. STEEL 0: 0 MULTIBLADE BACKDRAFT DAMPER YES YES YES (n w BIRDSCREEN NO NO NO U a SOLID STATE SPEED CONTROL NO NO YES THERMOSTAT CONTROL NO NO NO FACTORY FABRICATED CURB NO NO NO FILTER AND FILTER FRAME NO NO NO HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR - X FIRE DAMPER(S) - X SMOKE DAMPER(S) - X FIRE RATED ENCLOSURE - X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY _ X FIRE STOPPING - X SMOKE CONTROL - X CJ oO�fl • o I�,PJ, Inc. STATE OF FL CO. NO. (000065130 ) P.E. NO. (� 16395) 4977 S.W. 74th COURT MIAMI, FL 33155 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 JCHAS & ASSOCIATES, PA 0 43M &W. '11 TH STRIEL7 MWrN, Ratio 33146 TEL- (305) 969 3149 FAX: (305) 4471501 JACFIASTANI T O d M A R 0 0 1 2 6 1 1 OWNERS: PALMAS OF SUNSET J.V. 5835 Blue Lagoon Drive, Subs 200 Mlerrrl, Fbrkia 33126 T 786275.8480 F 786275.8474 x ` ' R AEL P A Jit. (1639 ��M v� oO�fl • o I�,PJ, Inc. STATE OF FL CO. NO. (000065130 ) P.E. NO. (� 16395) 4977 S.W. 74th COURT MIAMI, FL 33155 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 JCHAS & ASSOCIATES, PA ARCHITECTURE PLANNING INTERIORS 43M &W. '11 TH STRIEL7 MWrN, Ratio 33146 TEL- (305) 969 3149 FAX: (305) 4471501 JACFIASTANI T O d M A R 0 0 1 2 6 1 1 OWNERS: PALMAS OF SUNSET J.V. 5835 Blue Lagoon Drive, Subs 200 Mlerrrl, Fbrkia 33126 T 786275.8480 F 786275.8474 ��M v� O T Z M 0� ® 11 III O � ILL nn� U � O010 IuL, . MO L� a , A T E: D12-14-03 REVISIONS: PROJECT Na 03 -060 DRAWN BY: n T. L ILS CHECKED BY: RPJ SCALE: AS SHOWN SHEET No. AC -4