Loading...
04-52-034JCHAS & ASSOCIATES, PA ARCHITECTURE PLANNING INTERIORS 4361 S.W. 11 TH STREET Miami, Florida 33146 TEL: (305) 989 3149 FAX (305) 447 1501 i \ ; � JACHASTANET � aol.com 15 15 15 _ 15 / 15 15 A R 0 0 1 2 6 1 1 hPi 13 OWNERS: PALMS OF SUNSET J.V. I — 5835 Blue Lagoon Drive, Suite 200 Miami, Florida 33126 T 786.275.8480 PLAN PLAN PLAN - — F 786.275.8474 PLAN — PLAN PLAN - - - -�7 PLAN — — - -07 PLAN - _ — PLAN ' ' \ I. - - �Hl H B7, I 'I 41 ' , BASE f 16 BASE 16 BASE 16 BASE ' 16 BASE -- 16 BASE 16 BASE /� BASE BASE / / , / Li17 — 17 — 17 7 77 ^ METAL FRAME METAL FRAME METAL FRAME D 8" CMU WALL 8" CMU WALL 8" CMU WALL 8" CMU WALL u 8" CMU WALL I 8" CMU WALL 5/8 " GYP. BOARD BOTH SIDES 5/8" GYP. BOARD ONE SIDES CERAMIC TILE BOTH SIDES ONE SIDE: 5/8" GYP. BOARD BOTH SIDES: 5/8" GYP. BOARD ONE SIDE: CERAMIC TILE ONE SIDE: CERAMIC TILE ' I BOTH SIDES: CERAMIC TILE BOTH SIDES: PAINTED CERAMIC TILE ONE SIDE ONE SIDE: 3/4" SMOOTH STUCCO ONE SIDE: 3/4" SMOOTH STUCCO ONE SIDE: 5/8" GYP. BOARD FINISH FINISH MATERIAL LEGEND GENERAL NOTES FOR ALL PARTITIONS: ° _j ° NUMBER DESCRIPTION W 3 -5/8 ", 25 GAUGE GALV. METAL STUDS X16" O.C. 1. USE MOISTURE RESISTANT "GREEN BOARD" @ WET AREAS WHERE (n TILE IS NOT USED (INCLUDES ALL BATHROOM, KITCHENS, LAUNDRY a '; 2O 6 ", 25 GAUGE GALV. METAL STUDS @ 16" O.C. ROOMS AND AHU CLOSETS. O W I y -- _ V c� 2. GYPSUM BOARD SHALL BE CONTINUOUS TO UNDERSIDE OF CEILING 3-5/8", 25 GAUGE, GALV. METAL TRACK. p ALL FIRE RATED PARTITIONS & ALL PENETRATIONS SHALL HAVE M 1 ., PROPER UL. RATED FIRE SAFING AS PER ASTM E 814 & UL 1479 W M 6", 25 GAUGE, GALV. METAL TRACK. v TEST CRITERIA. SEE PENETRATION DETAILS —10 O5 8 ", CONC. WALL OR COLUMN O = w 0 U � V -0 J , ~� 4 3 5/8" 20 GAUGE GALV. METAL STUD FRAMING 3. PROPER BRACING OF STUDS SHALL BE THE RESPONSIBILITY OF THE C ~ OJ 17 PLAN - PLAN`--*__ - CONTRACTOR. O LL O7 1X2 P.T. WOOD FURRING ® 16" O.C. — ° rII W fA 8 PAPER - BACKED METAL LATH 4. AT ALL FIRE RATED WALLS, Q IT SHALL BE THE CONTRACTORS U) �. RESPONSIBILITY TO ENSURE PROPER CONSTRUCTION UNDER U.L. co — — 9O 3/4" CDX EXTERIOR GRADE PLYWOOD DESIGN CRITERIA. O � - -- - --" �• - - - - -; - - -- �� _ — -"'��� �"'� 10 5/8- WATER RESISTANT GYP. BOARD ° O / 5• MASONRY NOT TO BE BROKEN AT LOCATION OF ELECTRICAL O RECEPTACLES 8" 18 8" CMU 17 - -- `' 17 12 / 6. ALL FIRE RATING SHOWN FOR PARTITIONS REFER TO FIRE RESISTANT ' a� O 5 8" GYP. BOARD RATING PER UNDERWRITERS LABORATORIES, OR GYPSUM ASSOC. - -- 1s -- - -- is 16 —7 3/4" STUCCO, SMOOTH FINISH — PRIMED & PAINTED FIRE RESISTANCE DESIGN MANUAL ( LATEST EDITION) 14 ° CERAMIC TILE J 7. PROVIDE MOISTURE RESISTANT (M.R.) DRYWALL FULL HEIGHT AT UNDERSIDE OF CONIC. SLAB PERIMETERS OF TUBS & SHOWERS 8" CONCRETE WALL 8" CONCRETE WALL 8" CMU 8" CONCRETE WALL ^ I NOT USED 16 TOP OF FLOOR SLAB J ONE SIDE: 3/4" SMOOTH STUCCO ONE SIDE: 5/8" GYP. BOARD IVI ONE SIDE: 5/8" GYP. BOARD N j7 SCHEDULED FINISH FLOOR &BASE BOARD 8' ALL PLUMBING HORIZONTAL BRANCHES & TRAPS WHICH OCCUR FINISH O BELLOW SLABS TO BE WRAPPED W /NOISE BARRIER MATERIAL USE ; 3/4 RIGID INSUL. TO STRUCTURE ABOVE - - E A R NON REINFORCED ACOUSTICAL BARRIER MANUFACTURED BY O18 - R -4.2 MIN. E -A -R DIVISION CABOT CORPORATION (WB -10) OR EQUAL ( NOT REQUIRED IF CAST IRON) 9. ALL ELECTRICAL RECEPTACLES AT STUD PARTY WALLS TO BE STAGGERED A MIN. OF 1' -0" APART (NO BACK TO BACK OUTLETS) PERIMETER OF OUTLET BOXES TO BE SEALED W/ ACOUSTICAL CAULKING. 10. EXTERIOR FINISH TO BE STUCCO ON SCRATCH COAT. 11. WALL HUNG FIXTURES. STUDS IN NON- BEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES & WALL CABINETS TO BE 20 GA. METAL STUDS @ 16" O.C.FOR THE ATTACHMENT OF EACH WALL HUNG PLUMBING FIXTURE AND WALL CABINET IN 2 LAYERS 5/8 ' TYPE Y GYP BD. INSTALLD PER UL N0. U415 SYSTEM B ( 2 HR. ARE RATED 12• CORRIDOR PARTITIONS, SMOKESTOP PARTITIONS, HORIZONTAL EXIT f PARTITIONS, EXIT ENCLOSURES, AND FIRE RATED WALLS REQUIRED TO HAVE PROTECTED OPENINGS SHALLL BE EFFECTIVELY AND D AT E: PLAN 1" GYP FIRE CODE SHAFT PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER 12 -14 -03 ON 2 1'2 CH STUDS (25 CA AT 24' 0.C.) ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING AND IN REVISIONS: LATERAL BRACING 0 4"0" O.C. CONCEALED SPACES. SUGGESTED WORDING: FIRE AND SMOKE ON 2 1'2 CH STUDS (25 CA AT 24' O.C.) BARRIER PROTECT ALL OPENINGS. ,HAFT 11_ OOR SIDE AND CEILING RUNNERS 'J" SHAPED RUNNER 2 1/2' PROJECT No. 24 MSG GA PER UL NO. U415 03-060 DRAWN BY: `. CHECKED BY: JC METAL FRAME O 5/8" GYP. BOARD BOTH SIDES 2 HR. FIRE RATED WALL PER UL DESIGN NO. U -415 SCALE: FIRE FESISANCE DIRECTOR VOL 1 PAGE 740 -741 AS SHOWN - - - - -24 -MSG GA PER UL NO. U415 - - - - -- SHEET No. 0