Loading...
04-52-0160 it1 r f� 1 2 3 4 5 A A4 CONCRETE I DOWN SPOUT W/ I EMEWSENCY PRE CAST OVERFLOW CONC. SPLASH SCUPPER(TYPJ BLOCK I 11' -9" 25' -6" 11-111 11-91 21_611 9._0.. 2'4'1' -0" ELEV. 25'-foll _ �1 _ ���• I •�� ••�'•�i I II II I p 1 = TOP of EYEBROW N ! i DOWN SPOUT W/ L �n I • �••� � - I I LI = = dI = _ _ II �_ I I _ _ I I _ _ RI - = Q I _= _ iIiI _ = _ I I I ! PRE- ENGNERE D t ��l WO TRUSSES PRE CAST ELEV. 25' -9" CONC. SPLASH TOP OF ROOFLPJ ! j I BLOCK 3 A _ _ �,! I I I I A -WTYP. Ise__- _.},�_ =v � _ i I _ ELEV. + 30' -6" C4 z E a 1' -8" X 1' -e" I I I I n AiA 1 WALL MOUNTED Fl = _ _ _ _ A TOP OF WALL CONCRETE ri 1294 SF HOR 'L S.S. ACCESS PAN£ I� 4: IZ TYR I I N EMERGENCY y �+ 510 /2 = 255 8F VERT. qn _ _ _ OVERFLOW TOTAL - 154S SF _ _ _ _ _ _ = I ELEV. + 28' -6" SCUPPER (TYPJ S I I I I TOP OF WALL ` 1,4 " FT. min I I I I DOWN SPOUT W/ �� TOP OF ROOF(HP) I I = u ii I o _i I ! ELEV. + 25' -6" B C — ELEV. +26 -4 f- _____T = = = -= CONC. SPLASH TOP of ROOF(NP) I 1 II it I 1 I II I Top OF EYEBROW I � BLOCK I II II I I I I ELEV. + 28' -6" _ ELEV. + 28' -6" L -11- - _ -H- J TOP OF PARAPET r TOP OF PARAPET " e cj ql I q " ELEV. + 25'- 6 "(LP) TOP OF ROOF � ON CONCRETE SL 0 EMI=RGENCY v 1�a" FT. mtn 12,_0„ r OVERFLOW £LEY. + 32' -6" ELEV. + 23' -8" 5 .'UPPER (TYPJ toP of PARAPET BOTTOM OF £Y£BROw e Q ELEV. + 28' -6" -I ELEV. + 28' -6" in TOP of PARAPET `r AREA 2 TOP OF PARAPET VP ca 45' -8" 1031 SF NOR v 534 /2 = 261 8F VERT. ;h `^ TOTAL = 104 SF C Ev + 26' -4" TOP OF ROOF(HP) y SL ON B B 'Q" FT. min. AREA 3 1' -8" X 1' -8" ' - 1526 BF NOR FLUBW MOUNTED CRICKET 561 /2 - 281 SF VERT. PRE - ENGINEERED CONCRETE TOTAL - 1,801 SF S.S. ACCESS PANEL WOOD TRUSSES EMERGENCY 10 -8 24 O.G. OVERFLOW o E �- E SCUPPER (TYR) F- dk ELEV. + 30' -6" n I hI I � - _ _ ��tIIIr I ! I ! I IIIIII I I ! I !!Ip III I ! I IIIIII I I I I IIIIII I I I I I p_IIIIII I I I I @ p I 1 1 q 1 p I 1 IlI i III I �pp p II _ TOP OF WALL ELEV. + 25 9" 0 TOP of EYEB " R OW III III I DOWN SPOUT W/ ELEV. 25' - 3 PRE CAST TOP OF ROOF -gZ • �,• I II II II II Hz �II p I II II p I '� �4 �� �• •� f = it ll II !! IQ II p !I 11 _ _ ELEV. + 28 -6 CONC. SPLASH II 11 ,.11 1 11 II II 1 TOP OF WALL /� • k= =�I II II II II II 1 p II II p = — BLOCK 131-611 1 3.31-111 - - �- •, .• HJ - L t 17+ 1 - I - I "ri 1' -0" GOWN SPOUT U11 2' -1" N SPOUT 1' -8 6Qt PRE casT PRE CAST CONCRETE PRE �T CONC. SPLASH EMERGENCY C.SPLASH BLOCK OVERFLOW CK 25' -4" SCUPPER lT1rPJ A MIAMI DARE PRODUCT CONTROL APPROVAL ROOF TILES MPR 13Y ' MONIER" OR RAINFALL RATE= 5" PER HOUR APPROVAL EQUAL REF: SIGNATURE SERIES MISSION "S" STYLE: PINTO, COLOR BUTTERCUP BLEND NAILED ON S& HOT TAR MOPPED SLATE ON 300 TM CAPPED FELT ROOF FLAN GRADE ROOFI NAILS AT 12" OC, ON 5/8 EXT GRADE CDX (32/16) PLYWOOD NAILED W /8d NORTH COMMON MAILS AT 6" OC AT PANEL EDGES, SCALE : 1 /8" = �' -0" ® 6" OC AT INTERMEDIATE SUPPORTS AND 4" OC ALONG SIDE PANELS ROOF D A I NAGS CAL CUL ATOMS DESCRIPTION AREA 1 AREA 2 AREA 3 HORIZONTAL PROJECTED ROOF AREA 1294 OF NOR. 1031 OF HOR. 1526 SF NOR VERTICAL PROJECTED ROOF AREA 510 /2 = 255 8F VERT. 534 /2 = 261 BF VERT. 561 /2 = 281 8F VERT. TOTAL ( HOP. + VERT.) TOTAL - 1,549 OF TOTAL - 1,304 SF TOTAL - 1001 SF VERTICAL COND. OR LEADER(DOWNSPOUT) DIAMETER REQUIRED (PER MC- PLUMB. 11062) (2) 3" DIA. = 3,520 S.F. (2) 3" DIA. = 3,520 S.F. (2) 3" DIA. = 3,520 Sr-. VERTICAL COND. OR LEADER(DOWNSPOUT) DIAMETER PROVIDED (2) 4" DIA. = 1,360 S.F. (2) 4" DIA. = 1,360 S.F. (2) 4" DIA. = 1 ,360 SF EMERGENCY OVERFLOW SCUPPER REQUIRED (PER F5C- PLUMB. 11063) 50 SQ. IN. 50 so. IN. 50 SQ. IN. EMERGENCY OVEIRFLOW PROVIDED (2) 48 = 96 50. IN. (3) 48 = 144 SQ. IN. (2) 48 = 96 SQ. IN. REMARKS NOTE: RAINFALL RATE = 5" PER HOUR GENERAL ROOFING NOTES 1. ROOFING PLAN IS GENERAL IN NATURE AND INDICTATES APPROXIMATE CONDITIONS AT THE PROJECT SITE. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD SURVEY M REGARD TO QUANTITY, DIMENSIONS. ELEVATIONS, ROOF SLOPES CONDITIONS AND CONFORMANCE TO CODE. 2. CONTRACTOR SHALL CAREFULLY EXECUTE ALL WORK TO CARRY OUT ALL WORK REQUIRED TO MEET THE INTENT OF THE DRAWINGS. 3. ALL ROOF MOUNTED EQUIPMENT, CURBS. WOODWORK AND SHEET METAL WORK SHALL BE FASTENED SAFELY TO RESIST A MIN" 146 MPH WIND VELOCITY AS SPECIFIED IN F.B.G. (2001 EDITION) UNLESS OTHERWISE NOTED. 4. CONTRACTOR SHALL PERFO` I A ROOF SLOPE SURVEY TO VERIFY SLOPE CONDITIONS OF THE PROJECT PRIOR TO COMMENCEMENT OF ROOFNG WORK AN ADDITIONAL SURVEY SHALL BE CONDUCTED AFTER COMPLETION OF ROOFING WORK FOR CONFORMANCE TOTHE REQUIREMENT OF THE CONTRACT DOCUMENTS. 5. CONTRACTOR SHALL COORDINATE WITH MECH. ELEG. AND PLUMBING AS REQUIRED. 6. MAINTAIN A MIN. OF 10' -0" CL. FROM ANY EXHAUST TO ANY FRESH AIR INTAKE. 1. SHEET METAL FLASHING, ROOFING ACCESSORIES AND DRAINAGE COMPONENTS t0 BE SHOP FABRICATED 22 GA. COMMERCIAL GRADE PAINTED SHEET METAL. 8. MINIMUM INSULATION "R" VALUE , COMPLY WITH FBC IF HIGHER "R" VALUE IS REQUIRED. 3 FOR ROOF PIPE OR CONDUIT PENETRATIONS USE URETHANE INSULATED FLEXIBLE OR RIGID CONDUITS MODELS MEF -20, FEF -IA MF'R BY "THALLER ROOFNG SPECIALTIES PRODUCTS INC. OR APPROVED EQUAL INSTALL PER MPR SPECIFICATIONS. DO NOT USE PITCH POCKETS. 10. ALL ROOFING MATERIAL SYSTEM, INSULATION BOARD AND INSTALLATIONS SHALL COMPLY WITH FBC AND HAVE MIAMI DADE PRODUCT CONTROL APPROVAL. SUBMIT SHOP DWG6. To THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. - ,?L -ES 4 •C�,� ,c� � r JCHAS & ASSOCIATES, PA ARCHITECTURE PLANNING INTERIORS 4361 S.W. 11 TH STREET Miami, Florida 33146 TEL: (305) 989 3149 FAX: (305) 447 1501 JACHAWANET@aci.com A R 0 0 1 2 6 1 1 OWNERS: PALMS OF SUNSET J.V. 5835 Blue Lagoon Drive, Suite 200 Miami, Florida 33126 T 786.275.8480 F 786.275.8474 U) �W V ) D W O q M ..L. r Z w ct) O F c �.. ti O Q LL W U) d, Q O 0 C O I..L DATE: 12 -14 -03 REVISIONS: PROJECT No. 03 -060 DRAWN BY: CHECKED BY: JC SCALE: AS SHOWN SHEET No. A -2.4