Loading...
04-1660(3)-012F+u1Y •I• V • I Vu10v I60 • I •♦ IU . .. - • • . ♦ I I Y I • FLU MB_ I NG, NOTES . V • Y U (J V ; V • 1 • V • V I GENERAL Iwo •" • IWI w Y •Y1• • V l,vfi • PROVIDE .(.FiJRNISI i A[) rN5j -'AQY ) ALL NECESSARY MATERIAL S✓AND. ff3R,r LCOMPLETELY OPERATIONAL PLUMBING 5Y5TEM AS SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE AND LOCAL ORDINANCES. SCOPE OF WORK: PROVIDE THE FOLLOWING COMPLETE SYSTEMS: A. SANITARY COLLECTION. B. DOMESTIC HOT AND COLD WATER. PAY FOR ALL FEES, INSPECTIONS AND CONNECTION CHARGES REQUIRED. VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO FABRICATION OR INSTALLATION CORDINATE REQUIREMENTS TO AVOID INTERFERENCE WITH OTHER TRADES, SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF EQUIPMENT AND MATERIALS. Z"VTR SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF EQUIPMENT AND MATERIALS. GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. MATERIALS PROVIDE SHUT -OFF VALVES FOR EACH FIXTURE AND AIR CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM. PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS AND FASTENERS OF SIMILAR METALS OR ISOLATE THEM FROM PIPING AND SLABS TO PREVENT CORROSION. PIPING DOMESTIC HOT AND COLD WATER: COPPER TUBING TYPE "K" OR "L" WITH SOLDER JOINTS. WOG BRONZE VALVES 125 P.S.I. MIN. PROVIDE PRE- MOLDED FIBER GLASS INSULATION FOR HOT WATER LINES. SANITARY WASTE AND VENT: CAST IRON PIPING UNDER SLABS, CAST IRON NO --HUB OR COPPER D.W.V. ABOVE P.V.C. DRAIN PIPE AND FITTINGS MAY BE USED WHEN ALLOWED BY THE LOCAL JURISDICTION. rwEc SECOND FLOOR PLUMBING PLAN 1/4" = II-Off r 400,000 BTU 3,00L HEATER 1 ►, N . L25,000 BTU DRYER .f -ACV . 314" J I_' 50,000 BTU WATER HEATER 2 STAGE REGULATORS MAIN 8/0 COCK 91 TOTAL LOAD - 537,000 LONGEST RUN - 53' 120,000 BTU L RANGE GAS PIPING ISOMETRIC PLAN N.T.S. PLUMBING FIXTURE SCHEDULE SYM50L 5YM50L FIXTURE TYPE SIZE C.W. H.W. DE5CRIPTION Pi [r_-) WATER CLOSET 3" 112' - T WATER (H.W.) LINE P2 Q LAVATORY 1 -112' 112' 112" TE VALVE P3 CHECK BATH TUB 2" Ill' 1/2" PROVIDE ANTI -SCALD VALVE P4 BIBS KITCHEN SINK 1-114- 112' 112" wl GARBAGE DISPOSAL P5 Z DISHWASHER Y AFF A DISCHARGE INTO GARBAGE DISPOSAL UNIT. PG FL r --- — --- WASHING MACHI. 2" I /2' 112" P7 CD BIDET 2" 112' I/2" Pty ® ]SHOWER 2" 1/2' 112" PLUMBING LEGEND - 5�NITARY SEWER LINE ................. ........... ........ V NT LINE CTG C EANOUT TO GRADE C LD WATER (C.W.) LINE ----- H T WATER (H.W.) LINE FT P E55. t- TEMP. RELIEF LINE -- ----�� G. TE VALVE CHECK VALVE ---I I�—— UNION �— -• HOSE BIBS V5 VACUUM BREAKER vlv V LVE IN VERTICAL vTR V NT THRU ROOF AFF A OVE FINISHED FLOOR LEVEL —� FGO FL OR CLEAN OUT --- — --- G 5 LINE � B w C � � a C\ t P-1 r "J • � r�+r �• `C � s :a � B w C � � a C\ t P-1 J. M. --W K. C. DATE; 08 -09 -2004 SHEET I 4 � a '1 ~ N 7 a C) ra, CU CO �a CSC J. M. --W K. C. DATE; 08 -09 -2004 SHEET I 4 � a '1 ~