04-1660(2)-013PLUM131-NIS NOTE5 GENERAL PROVIDE ( FURNISH AND IN5VALL ) ALL NECESSARY MATERIALS_ AND' LABOR FOR_ A, COMPLETELY OPERATIONAL fy. - PLUMBING 5Y5TEM A5 5HOWN ON THE DRAWINGS AND HEREIN 5PECIFIED. INSTALL IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE AND LOCAL ORDINANCES. SCOPE OF WORK: PROVIDE THE FOLLOWING COMPLETE SYSTEMS: A. SANITARY COLLECTION. B. DOMESTIC HOT AND COLD WATER. PAY FOR ALL FEE5, INSPECTIONS AND CONNECTION CHARGES REQUIRED. VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS WITH PIPE, FIXTURES, AND EQUIPMENT 5IZE5 PRIOR TO FABRICATION OR INSTALLATION CORDINATE REQUIREMENTS TO AVOID INTERFERENCE WITH OTHER TRADES. SUBMIT SHOP DRAWINGS FOR ARCHITECT/ ENGINEER APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF EQUIPMENT AND MATERIALS. Z "VTR SUBMIT SHOP DRAWINGS FOR ARCHITECT/ ENGINEER APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF EQUIPMENT AND MATERIALS. GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMAN5t11P FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. PROVIDE SHUT -OFF VALVES FOR EACH FIXTURE AND AIR CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM. PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS AND FASTENERS OF SIMILAR METALS OR 150LATE THEM FROM PIPING AND 5LA135 TO PREVENT CORROSION. PIPING DOMESTIC HOT AND COLD WATER: COPPER TUBING TYPE "K" OR "L" WITH SOLDER JOINTS. WOG BRONZE VALVES 125 P.5.1. MIN. PROVIDE PRE - MOLDED FIBER GLA55 INSULATION FOR HOT WATER LINES. SANITARY WASTE AND VENT: CAST IRON PIPING UNDER SLABS, CAST IRON NO -HUB OR COPPER D.W.V. ABOVE P.V.C. DRAIN PIPE AND FITTINGS MAY BE USED WHEN ALLOWED BY THE LOCAL JURI5DICTION. FIXED SECOND FLOOR PLUMBING PLAN 1/411 =l'—off i N / BTU [1400,000 L HEATER / � � j x'.1/2'► / N . / r DRYER BTU / �N po 5' / - 314 50,000 BTU WATER HEATER _T - -_j 2 STAGE REGULATORS MAIN 810 COCK TOTAL LOAD - 537,000 LONGEST RUN - 53' A GAS PIPING ISOMETRIC PLAN N.T.S. PLUMBING FIXTURE SCHEDULE 5YMBOL 5YM130L FIXTURE TYPE 52E C.W. N.W. DE5CRIPTION Pi Ir-) WATER CL05ET 3" 112' - P2 O LAVATORY 1 -1 /2 1/2' 1/2_ P3 rn BATH TUB 2' 1/2' 1/2' PROVIDE ANTI -5CALD VALVE P4 c �• KITCHEN 51NK I -I/ 112' 1/2' w / GARBAGE 015P05AL P5 ® 015HWA5HER vTR V NT THRU ROOF DI5P05AL s I TO GARBAGE P6 OVE FINISHED FLOOR LEVEL rDl FLOOR WA5HING MACHI. 2" I12' 1/2' P7 BIDET 2" 1/2' 1/2" =F,3 ® 15HOMR, 2' 112' 1/2" PLUME3ING LEGEND 120,000 BTU I RANGE :t.` o ., I L� 7 .---4 S=ao Q Q) DI cc in DRAI'VN BY: J.M. - K.C. DATE: 08 -00 -2004 SHEET F- S1 NITAKY SEWER LINE .- - - - - -- - ..._ ............... ......... ..... ...... VII NT LI N E CTG -- C EANOUT TO GRADE COLD WATER (C. W.) LINE HOT WATER (H.W.) LINE — FT PRESS. � TEMP. RELIEF LINE GTE VALVE CHECK VALVE UNION c �• H 5E 5113B V5 V CUUM BREAKER vlv V LVE IN VERTICAL vTR V NT THRU ROOF AFP A OVE FINISHED FLOOR LEVEL FLOOR CLEAN OUT — — — G,5 LINE 120,000 BTU I RANGE :t.` o ., I L� 7 .---4 S=ao Q Q) DI cc in DRAI'VN BY: J.M. - K.C. DATE: 08 -00 -2004 SHEET F-