04-1538-007W/M W/M W/M
NEW PARTITION
NEW DOOR
EXIST. EXIST.
OFFICE 4 OFFICE 3
EXIST.
EXIST. EATING AREA
EXIST. OFFICE 2
OFFICE 5
2 "0 VENT
NEW 2 "0
1/4 to 0 C.W
2 "0 VENT
6 3 4 C.W
NEW " s� /
® 3 "0
2*0
XIST.
NFERENCE ROOM 3 "0
® TO EXIST.
O SEWER LINE
EXIST.
BATHROOM
7
EXIST 4 "0 SEWER LINE
AREA 1 SC 1/4" = 1'
tl L
to
07 c
18 "MIN
� ® W
NEW BATHROOM OF ICE 1
POSITION NEW
2" 0 VENT
2-0 �^l
1/4- 0 C.W
4 "0 SEWER LINE 1/4" 0 C.W 3/4" 0 C.W 3 00
AREA 3 SC 1/4 = 1'
s» � as»
ti
a I , K",
n
VTORY
COYER ALL HATER PIPE
18" IF HOT HATER IS PROVIDED
BANDI AAPPE
WATER CLOSET
RATHROOM ARVATIONS
12 "MIN
� 33 -36
BACK WALL
E.F. GRILLED
54 "MIN
36" MIN
SEAL PENETRATION OF
DUCT INTO ENCLOSURE
W /3M 128 FIRE SEAL
5/8" TYPE "X" GYP
WALL 8D ENCLOSURE
AROUND FAN HOUSING
5/8" TYPE "X"
GWB CEILING
EXHAUST FAN DETAIL
N.T.C.
TOILLET
PAPER
MIN 33— 36
17-19 1
SIDE WALL
5'
GENERAL PLUMBING NOTES
1, A, SCOPE OF WORK:
THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY ON THE
DRAWING SPECIFIED HERE IN AND /OR AS NEEDED FOR A COMPLETE
SYSTEM. INCLUDING BUT NOT NECESSARILY LIMITED TO:
1, RESIDENTIAL COLD AND HOT WATER PIPING SYSTEMS
2, SANITARY DRAIN AND VENT SYSTEM (N/A)
3. PLUMBING FIXTURES AND TRIM
4. AIR CONDITIONING CONDENSE DRAINS
5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER_:` \`,
6. PIPING INSULATION
7. SUPPORTS AND HANGERS
B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE. WITH
THE LATEST EDITION OF THE FLORIDA BUILDING- CODE, PLUMBLING.,
LOCAL ORDINANCES AND IN COMPLIANCE WITH: THE FLORIDA ENERGY
EFFICIENCY CODE FOR BUILDING CONSTRUCTION AND HRS, REGULATIONS!
IN THE EVENT OF CONFLICT BETWEEN ANY CODE OR REGULATIONS::
THE MORE STRINGENT REQUIREMENTS WILL, GOVERN. %
2. CONTRACTOR TO VERIFY AT SITE THE LOCATION ELEVATION 'AND
SIZE OF ALL EXISTING LINES FOR CONNECTIdN ,-BEF'ORE,-.INS:TALLATI ❑N
OF ANY PIPING. ;<
3, UNDERGROUND METAL PIPING SHALL BE PRO,T.ECTEILrWITH A COAT
OF BITUMINOUS COMPOUND BEFORE COVERING, BTTUMASTIC OR EQUAL.
4, ALL FIXTURES SHALL BE PROTECTED AGAINST--'WATER HAMMER WITH
AIR CHAMBERS OR SHOCK ABSORBERS AS INDICATED ON PLANS,
5, ALL FLOOR DRAINS TO HAVE TRAP PRIMERS X' LINE FROM THE
NEAREST PLUMBING FIXTURE.
6. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH APPROVED
MATERIALS SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL
BE FREE FROM DEFECTS AND CONCEALED FOULING SURFACES, ALL
FIXTURE TRIM TO BE CHROME PLATED. FIXTURES SHALL BE PROVIDE
WITH SUPPORTS, HANGERS, ETC.
7. WASTE LINES TO SLOPE 1/8 FT, UNLESS OTHERWISE NOTED.
8, VENT LINES TO EXTEND 9" MIN. ABOVE ROOF AND FLASH WITH
LEAD,
9, WATER PIPE BELLOW GROUND SHALL BE COPPER TYPE. ABOVE
GROUND TO BE COPPER TYPE.
10. PIPING INSULATION:
A, SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT
PROPER INTERVALS ACCORDING WITH CODE.
B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION,
SLABS OR MASONRY WALLS. CAULKS OPENINGS BETWEEN PIPE AND
SLEEVES.
C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR
CEILINGS PROVIDE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND
OF SUFFICIENT OUTSIDE DIAMETER TO COVER THE SLEEVED OPENING
FOR THE PIPES. PROVIDE CHROMIUM PLATED ESCUTCHEONS ON
BATHROOM.
11. INSPECTIONS AND TESTS
A. CONTRACTORS SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO
THE AUTHORITIES HAVING JURISDICTION. AS THE WORK PROGRESS ALL
SYSTEM SHALL BE TESTED BY CODE AND / OR LOCAL REGULATIONS.
B. DRAINAGE PIPING BEFORE INSTALLATION OF ANY DRAINS, THE END
OF SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH WATER
TO HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTIONS IS
MADE BY AN OWNER REPRESENTATIVE.
12. STERILIZE ALL WATER LINES WITH A MIXTURE OF 2 POUNDS OF
CHLORINATED LIMED TO 1000 GALLONS OF WATER (50PPM OF
AVAILABLE CHORINE), RETAIN MIXTURES IN PIPES 24 HOURS AND
FLOSS THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN
SERVICE.