Loading...
04-1538-007W/M W/M W/M NEW PARTITION NEW DOOR EXIST. EXIST. OFFICE 4 OFFICE 3 EXIST. EXIST. EATING AREA EXIST. OFFICE 2 OFFICE 5 2 "0 VENT NEW 2 "0 1/4 to 0 C.W 2 "0 VENT 6 3 4 C.W NEW " s� / ® 3 "0 2*0 XIST. NFERENCE ROOM 3 "0 ® TO EXIST. O SEWER LINE EXIST. BATHROOM 7 EXIST 4 "0 SEWER LINE AREA 1 SC 1/4" = 1' tl L to 07 c 18 "MIN � ® W NEW BATHROOM OF ICE 1 POSITION NEW 2" 0 VENT 2-0 �^l 1/4- 0 C.W 4 "0 SEWER LINE 1/4" 0 C.W 3/4" 0 C.W 3 00 AREA 3 SC 1/4 = 1' s» � as» ti a I , K", n VTORY COYER ALL HATER PIPE 18" IF HOT HATER IS PROVIDED BANDI AAPPE WATER CLOSET RATHROOM ARVATIONS 12 "MIN � 33 -36 BACK WALL E.F. GRILLED 54 "MIN 36" MIN SEAL PENETRATION OF DUCT INTO ENCLOSURE W /3M 128 FIRE SEAL 5/8" TYPE "X" GYP WALL 8D ENCLOSURE AROUND FAN HOUSING 5/8" TYPE "X" GWB CEILING EXHAUST FAN DETAIL N.T.C. TOILLET PAPER MIN 33— 36 17-19 1 SIDE WALL 5' GENERAL PLUMBING NOTES 1, A, SCOPE OF WORK: THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY ON THE DRAWING SPECIFIED HERE IN AND /OR AS NEEDED FOR A COMPLETE SYSTEM. INCLUDING BUT NOT NECESSARILY LIMITED TO: 1, RESIDENTIAL COLD AND HOT WATER PIPING SYSTEMS 2, SANITARY DRAIN AND VENT SYSTEM (N/A) 3. PLUMBING FIXTURES AND TRIM 4. AIR CONDITIONING CONDENSE DRAINS 5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER_:` \`, 6. PIPING INSULATION 7. SUPPORTS AND HANGERS B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE. WITH THE LATEST EDITION OF THE FLORIDA BUILDING- CODE, PLUMBLING., LOCAL ORDINANCES AND IN COMPLIANCE WITH: THE FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION AND HRS, REGULATIONS! IN THE EVENT OF CONFLICT BETWEEN ANY CODE OR REGULATIONS:: THE MORE STRINGENT REQUIREMENTS WILL, GOVERN. % 2. CONTRACTOR TO VERIFY AT SITE THE LOCATION ELEVATION 'AND SIZE OF ALL EXISTING LINES FOR CONNECTIdN ,-BEF'ORE,-.INS:TALLATI ❑N OF ANY PIPING. ;< 3, UNDERGROUND METAL PIPING SHALL BE PRO,T.ECTEILrWITH A COAT OF BITUMINOUS COMPOUND BEFORE COVERING, BTTUMASTIC OR EQUAL. 4, ALL FIXTURES SHALL BE PROTECTED AGAINST--'WATER HAMMER WITH AIR CHAMBERS OR SHOCK ABSORBERS AS INDICATED ON PLANS, 5, ALL FLOOR DRAINS TO HAVE TRAP PRIMERS X' LINE FROM THE NEAREST PLUMBING FIXTURE. 6. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH APPROVED MATERIALS SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS AND CONCEALED FOULING SURFACES, ALL FIXTURE TRIM TO BE CHROME PLATED. FIXTURES SHALL BE PROVIDE WITH SUPPORTS, HANGERS, ETC. 7. WASTE LINES TO SLOPE 1/8 FT, UNLESS OTHERWISE NOTED. 8, VENT LINES TO EXTEND 9" MIN. ABOVE ROOF AND FLASH WITH LEAD, 9, WATER PIPE BELLOW GROUND SHALL BE COPPER TYPE. ABOVE GROUND TO BE COPPER TYPE. 10. PIPING INSULATION: A, SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT PROPER INTERVALS ACCORDING WITH CODE. B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION, SLABS OR MASONRY WALLS. CAULKS OPENINGS BETWEEN PIPE AND SLEEVES. C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS PROVIDE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE DIAMETER TO COVER THE SLEEVED OPENING FOR THE PIPES. PROVIDE CHROMIUM PLATED ESCUTCHEONS ON BATHROOM. 11. INSPECTIONS AND TESTS A. CONTRACTORS SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE AUTHORITIES HAVING JURISDICTION. AS THE WORK PROGRESS ALL SYSTEM SHALL BE TESTED BY CODE AND / OR LOCAL REGULATIONS. B. DRAINAGE PIPING BEFORE INSTALLATION OF ANY DRAINS, THE END OF SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTIONS IS MADE BY AN OWNER REPRESENTATIVE. 12. STERILIZE ALL WATER LINES WITH A MIXTURE OF 2 POUNDS OF CHLORINATED LIMED TO 1000 GALLONS OF WATER (50PPM OF AVAILABLE CHORINE), RETAIN MIXTURES IN PIPES 24 HOURS AND FLOSS THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 1 I I I� 5" fi Ri FOR FLAN N d' d- O O O z O t d- LO Q O z m J Ln LO L— O ff) J 0) :E - . O Q = CL Ld m Q CC) z � z O Sly Vcvl5ion PIC — 2004 z� 0 s N I � � C-0