11-959-032MATERIAL DATA STRUCTURAL SPECIFICATIONS GENERAL ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENT GOVERNING EDITION OF THE FLORIDA BUILDING CODE. REINFORCING STEEL BARS FOR REINFORCING SHALL BE GRADE 60 DEFORMED BARS CONFORMING TO ASTM A106 OR A615. LAP SPLICES SHALL BE IN ACCORDANCE WITH ACI 318 - CURRENT EDITION UNLESS NOTED OTHERWISE ON THE PLANS. BARS TO BE WELDED OR FIELD BENT SHALL CONFORM TO ASTM A106. SLAB MEMBRANE - 15 MIL STEGO WRAP VAPOR BARRIER OR EQUIVALENT, MEETING ASTM E1145, CLASS 'C' REQUIREMENTS OR BETTER. LIGHT GAGE METAL FRAMING I. LIGHT GAGE METAL FRAMING SHALL BE DESIGNED AND FABRICATED BY A FRANCHISED LIGHT GAGE METAL FRAMING FABRICATOR (ICC -ES ER- 4943). 2. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE LIGHT GAGE METAL FRAMING TO BE INSTALLED AS SHOWN ON THE STRUCTURAL AND ARCHITECTURAL DRAWINGS, INCLUDING LAYOUT, SIZE OF MEMBERS, AND CONNECTION DETAILS. IN ADDITION TO THE ABOVE DRAWINGS CALCULATIONS SHOWING ALL STRESSES AND DEFLECTION CAUSED BY DEAD AND LIVE LOADS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. DRAWINGS AND CALCULATIONS SHALL BE SIGNED BY A REGISTERED CIVIL ENGINEER OF THE STATE OF FLORIDA. 3. LIGHT GAGE METAL FRAMING DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE APPLICABLE REQUIREMENTS OF THE 2001 F.B.C. 4. LIGHT GAGE METAL FRAMING FABRICATOR SHALL OBTAIN ALL NECESSARY APPROVALS FROM THE PUBLIC AGENCIES INVOLVED IN GOVERNING CONSTRUCTION. 5. ARC WELDING ELECTRODES SHALL BE E60 SERIES FOR LIGHT GAUGE METAL FRAMING 6. SECTIONS 18, 20GA, FY = 33 KSI. 1. SECTIONS 16GA, FY = 50 KSI. FASTENERS ALL FASTENERS USED FOR LIGHT GAGE METAL ATTACHMENTS TO STRUCTURAL STEEL SHALL BE 1/4' SELF DRILLING SCREWS (S.D.S.) BY HILTI PRODUCT OR EQUAL. ALL FASTENERS USED FOR METAL STUDS AND METAL JOIST CONNECTIONS SHALL BE 010 -16 SCREWS U.N.O. (USE FLATHEADS WHERE SURFACE IS TO BE FINISHED WITH GYP. BOARD OR PLYWOOD). ALL FASTENERS USED AT CONCRETE EMBEDMENTS, SHALL BE POWDER DRIVEN FASTENERS BY HILTI PRODUCT OR EQUAL. (ICC -ESR- 1663). STRUCTURAL STEEL AND MISCELLANEOUS IRON STRUCTURAL STEEL AND MISCELLANEOUS IRON SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENT EDITION OF THE A15C CODE OF STANDARD PRACTICE. I. WIDE FLANGE AND STRUCTURAL TEE SHAPES SHALL CONFORM TO ASTM A992. 2. CHANNELS AND ANGLES SHALL CONFORM TO ASTM A36. 3. STRUCTURAL PLATE SHALL CONFORM TO ASTM A36 OR ASTM A512 GR50. ALL STRUCTURAL STEEL AND MISCELLANEOUS IRON SHALL RECEIVE SHOP PRIME COAT EXCEPT ON SURFACES RECEIVING WELDS, EMBEDDED IN CONCRETE, OR AT SLIP CRITICAL HIGH STRENGTH BOLTS WHICH SHALL BE TOUCHED UP AFTER CONNECTION IS COMPLETE. STRUCTURAL STEEL AND MISCELLANEOUS IRON WHICH 15 TO HAVE SPRAY ON FIREPROOFING SHALL NOT BE PAINTED. STRUCTURAL STEEL PERMANENTLY EXPOSED TO WEATHER SHALL RECEIVE TWO COATS OF SEMI -GLOSS ALKYD ENAMEL COMPATIBLE WITH PRIMER HOLLOW STRUCTURAL SECTIONS - ASTM A500, GRADE B, Fy =46 KSI (TYP, UNO) MACHINE BOLTS. ANCHOR BOLTS. STUDS AND THREADED RODS 1. BOLTS AND RODS SHALL CONFORM TO ASTM A301 GRADE A OR B OR A36. 2. NUTS SHALL BE AS SHOWN BELOW AND FINISH SHALL MATCH FASTENER. FASTENER GRADE AND SIZE NUT CLASS NUT STYLE ASTM A3(o OR ASTM A301A,1'4' TO ly' ASTM A563 -A HEX A5TM A36 OR ASTM A301A, OVER I)V2' TO 4' ASTM A563 -A HEAVY HEX ASTM A3015, Y4' TO 4' ASTM A563 -A HEAVY HEX 3. HEADED STUDS AND WELDING SHALL CONFORM TO AWS DI.I- CURRENT EDITION, TYPE B STUDS, WELDING ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS PER AWS 'STANDARD QUALIFICATION PROCEDURE' TO PERFORM THE TYPE OF WORK REQUIRED. ALL WELDING SHALL BE IN ACCORDANCE WITH THE CURRENT AWS WELDING CODE. ARC WELDING ELECTRODES SHALL BE E10 SERIES FOR A36, A512 4 A992 MATERIAL, AND E80 SERIES FOR A106 REINFORCING STEEL. WELD METAL TOUGHNESS SHALL BE REPORTED ON THE ELECTRODE MANUFACTURER'S CERTIFICATE OF COMPLIANCE. ALL ELECTRODES SHALL BE LOW HYDROGEN WITH A MINIMUM CVN VALUE OF 20 FT -L55 AT -207 F. EXCEPTIONS: METAL DECK WELDING, STAIR AND HANDRAIL WELDING, LIGHT GAGE STEEL WELDING. TACK WELDS, AIR -ARC GOUGING AND FLAME CUTTING SHALL NOT BE PERFORMED WITHOUT ADEQUATE PREHEAT OR INCORPORATION INTO THE FINAL WELD. THE FILLER METAL MANUFACTURER'S PUBLISHED RECOMMENDATIONS SHALL BE THE BASIS FOR DETERMINING THE ALLOWABLE RANGE OF ESSENTIAL VARIABLES FOR THE PRE QUALIFIED WPS. UNLESS NOTED OTHERWISE ON THE PLANS, BACK -UP BARS FOR CJP WELDS SHALL BE REMOVED FOLLOWED BY BACKGOUGING AND BACKWELDING. FRAMING REQUIRED OBSERVATIONS BY SIMICTURAL ENGINEER OF RECORD- 2. STEEL 4 MISC. METALS FRAMING 3. CONTRACTOR SHALL NOTIFY ENGINEER A MINUMUM OF 2 WORKING DAYS PRIOR TO THE TIME WHEN HIS PRESENCE 15 REQUIRED. PLEASE NOTE THAT THESE OBSERVATIONS ARE INDEPENDENT OF INSPECTIONS REQUIRED BY THE CITY BUILDING DEPARTMENT. EPDXY EPDXY RE51N ADHESIVE SHALL BE 5ET -XP AS MANUFACTURED BY SIMPSON STRONG -TIE OR EQUAL(ICC -E5 REPORT E5R - 2508). THE TYPE AND PROPORTIONS SHALL BE AS RECOMMENDED BY THE MANUFACTURER FOR THE CONDITION AND USE. PREPARATION OF CONCRETE INCLUDING DRILLING OF HOLES FOR ANCHORS, AS WELL A5 EPDXY AND ANCHOR INSTALLATION SHALL BE AS RECOMMENDED BY THE MANUFACTURER SUBMITTALS SUBMITTALS FOR THE ENGINEERS REVIEW WILL BE REQUIRED AS FOLLOWS: I. STRUCTURAL STEEL AND MISCELLANEOUS METALS SHOP DRAWINGS. 2. WELDING PROCEDURE SPECIFICATIONS (AND PQR IF APPLICABLE). CONTRACTOR SHALL SUBMIT TWO SETS OF PRINTS FOR REVIEW. FABRICATOR SHALL NOT PROCEED NOR SUBMIT TO CITY OFFICIAL UNTIL SUBMITTALS HAVE BEEN REVIEWED AND 5TAMPED BY THE ENGINEER. 3. LIGHT GAGE METAL SHOP DRAWINGS. 4. STORE FRONT SHOP DRAWINGS. CONCRETE CONCRETE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENT EDITION OF ACI 301 4 318. CONCRETE SHALL BE READY -MIXED CONCRETE IN ACCORDANCE WITH ASTM C94. MAXIMUM WATER - CEMENT RATIO, BY WEIGHT 28 DAY COMPRESSIVE STRENGTH NON -AIR ENTRAINED AIR ENTRAINED 2500 PSI CONCRETE .50 .50 3000 PSI CONCRETE .55 .55 AT THE CONTRACTOR'S OPTION, AN AIR ENTRAINING AGENT CONFORMING TO THE LATEST REVISION OF A5TM SPECIFICATION C260 MAY BE ADDED TO THE CONCRETE TO PROVIDE SPECIFIED AMOUNTS OF ENTRAINED AIR CEMENT SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PORTLAND CEMENT PER ASTM DESIGNATION C150, TYPE II. CONCRETE MIN 28 DAY MAX SIZE MAX TOTAL AIR ELEMENT 7,OMPRE5SIVE AGGREGATE SLUMP CONTENT EQ STRENGTH (INCHES) (INCHES) (51.) SLABS ON GRADE 3000 1 4 4%t15% FOOTINGS 3000 1 4 4 %tl.5go SLUMP WILL BE MEASURED AT THE TRUCK DISCHARGE. PUMPING OF CONCRETE MAY REQUIRE ADMIXTURES TO INCREASE SLUMP BEYOND THE MAXIMUM SLUMP LISTED ABOVE. ADMIXTURES ARE SUBJECT TO THE ENGINEER'S REVIEW. THE SPECIAL INSPECTOR SHALL BE PROVIDED WITH A BATCH TICKET AND WEIGHT TAG UPON DELIVERY OF EACH LOAD OF CONCRETE. ALL CONCRETE SHALL BE PLACED WITH MECHANICAL VIBRATION UNLESS NOTED OTHERWISE. NON - SHRINK GROUT NON - SHRINK GROUT SHALL BE PLOWABLE, WITH A MINIMUM COMPRESSIVE STRENGTH OF 5000 pal. NON - SHRINK GROUT SHALL BE MASTERFLOW 928 GROUT AS MANUFACTURED BY MASTER BUILDERS OR APPROVED EQUAL. SPECIAL INSPECTION NON- SHRINK/EXPANSIVE GROUT TAKE TEST SPECIMENS AND CONTINUOUSLY INSPECT THE PLACEMENT OF NON - 5HRINK/EXPANSIVE GROUT. BOLTS INSTALLED IN CONCRETE PERIODICALLY INSPECT INSTALLATION OF BOLTS AND CONTINUOUSLY INSPECT PLACEMENT OF CONCRETE AROUND SUCH BOLTS. STRUCTURAL STEEL AND MISCELLANEOUS IRON VERIFY THAT MILL CERTIFICATES SHOW STRUCTURAL STEEL AND MISCELLANEOUS IRON 15 IN COMPLIANCE WITH PROJECT SPECIFICATIONS. WELDING VERIFY WELDER CERTIFICATIONS, COMPLIANCE WITH WELDING PROCEDURE SPECIFICATIONS AND FOR (IF APPLICABLE). CONTINUOUSLY INSPECT ALL STRUCTURAL WELDING, INCLUDING WELDING OF REINFORCING STEEL. EXCEPTIONS: I. FLOOR AND ROOF DECK WELDING MAY HAVE PERIODIC INSPECTION. 2. WELDED STUDS USED FOR DIAPHRAGM OR COMPOSITE CONSTRUCTION MAY HAVE PERIODIC INSPECTION. 3. WELDED SHEET STEEL FOR COLD FORMED STEEL FRAMING MAY HAVE PERIODIC INSPECTION. 4. WELDED OF STAIRS AND RAILING SYSTEMS MAY HAVE PERIODIC INSPECTION. NONDESTRUCTIVE TESTING: 1. ALL COMPLETE JOINT PENETRATION WELDS ON MATERIALS 5/f6' THICK AND GREATER REQUIRE ULTRASONIC TESTING. THE RATE OF TESTING MAY BE REDUCED TO 2E % IF THE FAILURE RATE MEETS THE REQUIREMENTS OF CBC SECTION 1104 AND AWS SECTION 6.20. 2. PARTIAL JOINT PENETRATION WELDS WITH EFFECTIVE THROAT THICKNESS OF 3'4' OR GREATER REQUIRE ULTRASONIC TESTING. 3. WELDS ON BASE METAL THICKER THAN lY' REQUIRE ULTRASONIC TESTING. SPECIAL INSPECTOR THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE HIS COMPETENCE TO THE SATISFATCTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF A CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE APPLICABLE DESIGN DRAWINGS AND SPECIFICATIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, THE ENGINEER OR ARCHITECT OF RECORD, AND ANY OTHER DESIGNATED PERSONS ON A WEEKLY BASIS. ALL DISCREPANCIES SHALL SE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE PROPER DESIGN AUTHORITY AND TO THE BUILDING OFFICIAL. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WEATHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF HIS KNOWLEDGE, IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS, AND THE APPLICABLE WORKMANSHIP PROVISION OF THIS CODE. GENERAL NOTES I. CONSIDER GENERAL NOTES AS APPLYING ALL DRAWINGS. 2. DO ALL WORK IN ACCORDANCE WITH ALL STATE AND LOCAL BUILDING CODES IN AFFECT AT PLACE AND TIME OF CONSTRUCTION. 3. PROVIDE SPECIAL INSPECTION AS REQUIRED BY STRUCTURAL SPECIFICATIONS. 4. CONSTRUCT THOSE FEATURES OF THE PROJECT, WHICH MAY NOT BE FULLY SHOWN, IN MANNER SIMILAR TO THAT USED FOR SIMILAR FEATURES. 5. OMISSION OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE DRAWING, NOTES AND DETAILS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND RESOLVED PRIOR TO THE PROCEEDING WITH THE WORK. 6. CONTRACTOR SHALL REVIEW THE NEED FOR TEMPORARY, SHORING, CHEMICAL GROUTING OR UNDERPINNING PRIOR TO EXCAVATION. CONTRACTOR SHALL DESIGN AND INSTALL ALL TEMPORARY BRACING, ETC- REQUIRED DURING ALL STAGES OF WORK. 1. CONTRACTOR SHALL SUBMIT IN WRITING, ANY REQUEST FOR MODIFICATIONS TO THE PLANS AND SPECIFICATIONS. SHOP DRAWINGS SUBMITTED FOR REVIEW DO NOT CONSTITUTE 'IN WRITING' UNLESS IT IS CLEARLY NOTED THAT SPECIFIC CHANGES ARE BEING REQUESTED. 8. ALL CONSTRUCTION WORK SHALL CONFORM TO 2001 FLORIDA BUILDING CODE. 9. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION AND NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 10.RETURN TO ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF OPENINGS AND PENETRATIONS. COORDINATE PENETRATIONS. NO NEW OPENING SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT. II. REFER TO ARCH, MECH, AND ELECTRICAL DRAWINGS FOR LOCATION AND SIZE OF BLOCK OUT, INSERTS, OPENINGS, AND CURBS. DIMENSIONS ARE NOT SHOWN ON STRUCTURAL DRAWINGS. 12. GENERAL CONTRACTORS SHALL VERIFY WITH STRUCTURAL ENGINEER ALL MECH. UNIT LOCATIONS PRIOR TO INSTALLATIONS. 13. CONSTRUCTION LIABILITY. CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS AGREE THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONTRACTOR AND HIS SUBCONTRACTORS WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB 51TE CONDITIONS DURING THE COURSE OF CONTRACTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THAT THI5 REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS FURTHER AGREE TO DEPEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPT LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. ABBREVIATIONS STANDARD SIERRA ENGINEERING GROUP STRUCTURAL ABBREVIATIONS OD OVER O/ PARALLAM ABBREVIATION ABBR EQUAL EQ ABOVE FINISH FLOOR AFF EVERY OTHER E/O ADDITIONAL ADD'L EXISTING (E) ALTERNATE ALT FAR SIDE FS ANCHOR BOLTS AB FINISH FLOOR FF ARCHITECTURAL ARCH FLOOR FLR ATTACHMENT ATTACH FLOORJOIST FJ BEAM BM FOOTING FTG BEARING BRG FOUNDATION FND BETWEEN B' TWN FRAMING FRM'G BLOCKING BLK'G GALVANIZED GALV BOTTOM BOTT GAUGE GA BOTTOM OF BO GIRDER GDR CAMBER CAME GLUE -LAM GLB CEILING CLG GYPSUM WALL BOARD GWB CHANGE CHG HANGER HGR CHANNEL C HEADED WELDED STUD HW5 CLEARANCE CLR HEADER HDR COLLECTOR COLL HEIGHT HT COLUMN COL HIGH STRENGTH HS CONCRETE CONC NIGH STRENGTH BOLT HSB CONCRETE MASONRY UNIT CMU HOLLOW STEEL SECTION HSS CONDENSING UNIT CU HOLDOWN HD CONNECTION CONN HORIZONTAL HORIZ CONTINUOUS CONT HOT DIPPED GALVANIZED HDG DEEP DP IN51DE DIAMETER ID DIAGONAL DIAL MACHINE BOLT MB DIAMETER DIA MANUFACTURER MFR DIMESION DIM MATERIAL MAT'L DOUBLE DBL MAXIMUM MAX DRAWING DWG MECHANICAL MECH DRAWINGS DWGS METAL MTL EACH EA MICROLLAM ML EACH WAY EW MINIMUM MIN EDGE NAILING EN NEAR 51DE NS ELECTRICAL ELEC NEARSIDE AND FAR SIDE NSFS ELEVATION ELEV ON CENTER OC EMBEDMENT EMBED OPEN WEB JOIST O W J OPENING OPNG OUTSIDE DIAMETER OD OVER O/ PARALLAM PARA PLATE I1? PLYWOOD PLYWD POLYETHYLENE PE PRESSURE TREATED PTDF DOUGLAS FIR RAFTER RFTR REINFORCEMENT RE INF REQUIRED REQ'D ROOF TOP UNIT RTU SEE ARCH DRAWING SAD SELF DRILLING SCREWS SDS SHEATHING 5HTG SHEET 5HT SIMILAR SIM SLAB ON GRADE SOG STANDARD STD STEEL STL STIFFENER 5TIF STRINGER STRNG'R STRUCTURAL 5TRUCT TAPERED STEEL GIRDER TSG THREADED ROD THRDRD TOUNGE AND GROOVE T4G TOP AND BOTTOM T45 TOP OF TO TRUSS JOIST TJI TUBE STEEL TS TYPICAL TYP UNLESS NOTED OTHERWISE LINO VERIFY -IN -FIELD VIF VERTICAL VERT WELDED - WIRE - FABRIC WWF WIDE FLANGE W WITH W/ WITHOUT W/O PROJECT DATA- I. PLANS AND CALCULATIONS FOR THE STRUCTURAL DEIGN _WERE_OA;�ED = _ UPON: THE 2001 FLORIDA BUILDING CODE. _ - _ _ --- _ ; _ _ _ ASCE STANDARD 1 -05. 2. _VERTICAL: _ CEILING DEAD LOAD = 6.0 P5F =" WINDS SPEED CRITERIA: WIND SPEED = 150 MPH WIND EXPOSURE - C DESIGN HEIGHT - 45 FT IMPORTANCE FACTOR - 1.00 SHEET INDEX 50.0 GENERAL NOTES AND SPECS 50.1 TYPICAL METAL STUD FRAMING DETAILS 50.2 TYPICAL METAL STUD FRAMING DETAILS 51.0 SLAB PLAN 4 CEILING FRAMING PLAN 52.0 ELEVATIONS 53.0 SECTIONS 4 DETAILS CITY OF SOUTH M BUILDING DEPT. EPT. STRUCTURAASECTl0N "j"r'rtr)VED BY: I IL SEG JOB NO.: 11089 DRAWN /CHECKED BY: HN /FNC SCALE: AS NOTED ISSUE FOR: PERMIT 09/14/11 .nooMrn d, CQ to a ,O 0 o�w�a F� o V2 zo � (n � CO mtoa2w a M � z� .w Mu 5.'yS;, 51132 S ATE OF 0 RIOP� TONAL 999 w 5, ,cz ° W G W M DC O O m LL W 7= CD a- M I- O LLJ W cl: Z LL z � W w F- CD Q 0 0* :D w �-' = r%. O I- U) L0 U) DEBRA Z. KROPORNICKI. ARCHITECT i . 1 S000 TITLE: SPECIFICATIONS AND GENERAL NOTES