KEY NOTES--
O MOUNT OUTLET AFF INSIDE QF CASH INFAP = J
FIXTURE. -
O EXTEND ONE EMPTY 3/4" CONDUIT WITH PULL
STRING FROM SPEAKER LOCATION TO SPEAKER
WIRE TERMINATION BOX IN NON SALES AREA.
TERMINATE AS INSTRUCTED BY EQUIPMENT
SUPPLIER.
03 PROVIDE NEW FIRE ALARM STROBE AS
INDICATED. CONNECT TO EXISTING NOTIFICATION
APPLIANCE CIRCUIT FOR OPERATION.
GENERAL NOTES
1. ALL OUTLETS SHALL BE INSTALLED AS DIMENSIONED,
ANY DISCREPANCIES AS TO LOCATION BETWEEN PLAN
AND EXISTING FIELD CONDITIONS SHALL BE CLARIFIED
WITH THE ARCHITECT BEFORE COMMENCEMENT OF
WORK.
2. ALL ELECTRICAL AND TELEPHONE WORK SHALL BE
INSTALLED IN STRICT ACCORDANCE WITH THE
ELECTRICAL CODE, NATIONAL BOARD OF FIRE
UNDERWRITERS, PUBLIC UTILITIES COMPANY,
TELEPHONE COMPANY, AND ALL OTHER AUTHORITIES
HAVING JURISDICTION.
3. ALL COVERPLATES AND DEVICES (TELEPHONE, DATA,
ELECTRIC, SWITCH) SHALL BE COLORED TO MATCH
ADJACENT FINISH.
4. ALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH
2 (TWO) PULL STRINGS BACK TO THE TELEPHONE
EQUIPMENT.
5. THE GENERAL CONTRACTOR SHALL PROVIDE ALL
CUTTING AND PATCHING OF ALL CHASES IN FLOOR,
WALLS AND CEILING AS REQUIRED.
6. ALL SURFACES WITH EXISTING OUTLETS TO BE
REMOVED, SHALL BE PATCHED FLUSH NTH
ADJACENT WALL SURFACES.
7. EXCEPT WHERE NOTED, ALL ELECTRICAL, TELEPHONE
AND DATA OUTLETS ARE TO BE MOUNTED AT 18"
AFF.
8. CENTERLINE TO CENTERLINE DIMENSIONS OF ANY
OUTLET PAIR OR GROUP SHALL NOT EXCEED 6 ".
9. PROVIDE MINIMUM 10% SPARE CIRCUITS IN EXISTING
ELECTRICAL PANEL WHERE APPLICABLE. PROVIDE
BREAKER LOCKOUTS FOR A/C UNITS AND SEPARATE
CIRCUIT OUTLETS AT TELEPHONE EQUIPMENT.
10. ALL WHIPS AND J -BOXES AS INDICATED FOR
DISPLAY FIXTURE SHALL NOT BE VISIBLE FROM THE
STORE. ALL BOXES, CONDUITS AND WIRING MUST BE
COMPLETELY HIDDEN. LOCATION OF WHIPS SHALL BE
COORDINATED WITH THE MILL WORKER PRIOR TO
INSTALLATION.
11. IT IS THE RESPONSIBILITY OF THE GC TO ASSURE
THAT UNDER FLOOR UTILITIES ARE NOT HARMED
DURING THE FLOOR CUTTING /DRILLING OPERATION.
LOW VOLTAGE SYMBOL LEGEND
SYMBOL
DESCRIPTION
REMARKS
0
TELEPHONE /DATA OUTLET WITH 3/4" CONDUIT
EXTEND CAT -V CABLES BACK TO
SCALE:
STUBBED OUT FROM WALL 6" ABOVE CEILING.
TELEPHONE BOARD.
MOUNT 18" A.F.F. TO CENTER LINE OF OUTLET
PERMIT
UNLESS OTHERWISE NOTED.
09/14/11
SPEAKER WIRE TERMINATION BOX.
SEE ARCHITECTURAL DRAWINGS FOR
l'J
EXACT SPEAKER LOCATIONS.
BOSE SPEAKER (#D5 -165) WITH WHITE FINISH
GC TO PROVIDE AND INSTALL
MOUNTED TO UNISTRUT CHANNEL AT 11' -0"
SPEAKERS, UNISTRUT SUPPORT,
A.F.F.
METAL CONDUIT AND SPEAKER WIRING
�,D r' ',I-
6 co c)
o
BACK TO ELECTRICAL ROOM AUDIO
A m 00
M I
o
Q
Q
SYSTEM. PAINT UNISTRUT TO MATCH
N
_p 1
EXISTING DECK /DUCT PAINT COLOR.
O 1,D
GC TO CORRDINATE SPEAKER WIRING
: In
WITH LIFE SAFETY CONTRACTOR FOR
> O d
Q
MUSIC SYSTEM EMERGENCY SHUT
E
oU
DOWN.
O
THERMOSTAT
SEE SHEET M100 FOR MORE
O cu
Z d'
FIRE ALARM CEILING MOUNTED HORN- STROBE.
EXISTING TO REMAIN.
1150 cd
NUMERAL ADJACENT TO DEVICE INDICATES
A
kD
CANDELA RATING.
�
FIRE ALARM STROBE. NUMERAL ADJACENT TO
MATCH EXISTING BUILDING STANDARD.
75 cd
DEVICE INDICATES CANDELA RATING.
U
E
EXISTING
Q)
ISSUED FOR PERMIT
ISSUED FOR CONSTRUCTION -
CONSULTING KAMM
PROJ CT �
MANAGER. PRO 2011 -0347
Juan J. ya ���`,```ON •�• CARL /''��I
m M 1407 West Ne Centas_ N
Deerfield Beac orida 3 2
Phone 954.949200 Fax 95 .949.2201
onsu engineering @ICammQonsult�lg.mm9
Certification oEAF*rization V89
'4
m
JOB NO.:
11025
DRAWN /CHECKED BY:
CML /DZK
SCALE:
AS NOTED
ISSUE FOR:
PERMIT
09/14/11
�,D r' ',I-
6 co c)
o
A m 00
M I
o
Q
Q
N
_p 1
O 1,D
: In
0)
> O d
Q
d
E
oU
(U d N
r'
CL
\
O cu
Z d'
Cn
o p�
cu
0
A
kD
Q • —
U
W �
U
�-
H
Q)
U.—
Q0
U
a
0
0
o W
M
Q V
L(i
Q
W
o J
M.
z
Ld a
r
M
.�
(y)
LU
F J LL
z Z
a
Ld
Ld 0
>
0 �
LU
Q
a- Q
z
Z CL
Q �r 0
0 D
w �. =
1` 0
F- �WLC)W
CEBM Z KROPOId M FROG=
WL OM4=
SHEET NO:
E102
TI TLE:
LOW VOLTAGE
PLAN