11-959-023LANDLORD HVAC CRITERIA - THE LANDLORD WILL OPERATE THE CENTRAL COOLING DURING NORMAL PUBLISHED BUSINESS HOURS. NO PROVISION ARE AVAILABLE FROM THE LANDLORD SYSTEM FOR 24 HOUR COOLING OR HEATING. - ANY UNUSED HVAC EQUIPMENT, DUCTWORK, PIPING, WIRING, ETC WITHIN OR SERVING THE DEMISED PREMISES MUST BE REMOVED. - TENANTS' LEASED SPACES SHALL BE DESIGNED SUCH THAT THE ENTRY DOORS ARE TO REMAIN CLOSED WHILE HVAC SYSTEM(S) ARE IN OPERATION. LANDLORD'S BUILDING SYSTEM IS NOT DESIGNED TO ADEQUATEL CONDITION TENANTS' RETAIL SPACES WITH THE ENTRY DOORS OPEN. - KNOCKOUT PANELS, REMOVABLE CEILINGS OR WALL SECTORS SHALL BE PROVIDED FOR REMOVAL"/ REPLACEMENT OF EQUIPMENT LARGER THAT WILL FIT THROUGH THE MINIMUM STANDARD 24 "X24 ACCESS SIZE. - ALL UNEXPOSED SA AND OA DUCTWORK SHALL BE EXTERNALLY INSULATED WITH FIBERGLASS INSULATION WITH VAPOR BARRIER. - INTERNALLY LINED DUCTWORK MAY BE USED FOR ACOUSTIC PURPOSES ONLY, NOT AS A SUBSTITUTE FOR EXTERNAL INSULATION. - TENANT SHALL EMPLOY A BALANCING FIRM DESIGNATED BY THE LANDLORD. PROVIDE A CERTIFIED BALANCE REPORT TO THE LANDLORD WHEN CONSTRUCTION AS COMPLETED. - CONTRACTORS SHOULD FAMILIARIZE THEMSELVES WITH NOT ONLY THE CRITERIA ON THIS SHEET, BUT ALSO THE TENANT INFORMATION HANDBOOK MEP FP CRITERIA AND ANY UPDATED INFORMATION BY CONTACTING EITHER THE SIMON TENANT COORDINATOR OR TES ENGINEERING. ter. NUN I H KEY NOTES 0 EXISTING BATHROOM TO REMAIN AS IS. _(CLEAN DIFFUSERS OR REPLACE THEM IF NE ESSARY. VERIFY WITH ARCHITECT AND OWNER OCONTRACTOR TO VERIFY ALL EXISTING blICTWuTch & NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. O3 NEW CEILING IN THIS AREA. MECH. CONTRACTOR TO REPLACE ALL CEILING MOUNTED MECHANICAL EQUIPMENT WITH IMILAR EQUIPMENT AND WITH SAME OR BETTER PERFORMANCE. FIELD VERIFY. O NEW LOCATION OF EXISTING THERMOSTAT. ONEW DIFFUSER TO MATCH BUILDING STANDARD. SEE MECHANICAL SCHEDULE. 6O PROVIDE CABLE OPERATED VOLUME DAMPER. O DUCTWORK TO BE CAPPED. O8 EXISTING CHILLED WATER UNIT TO REMAIN AS IS. O9 EXISTING EXHAUST FAN TO REMAIN AS IS. 10 REPLACE EXISTING 6 "0 EXHAUST DUCTWORK WITH NEW GALVANIZED SHEET METAL DUCTWORK. LEGEND NEW wommonammumm EXISTING :A5E LINE MECHANICAL LEGEND ® NEW S/A CEILING DIFFUSER EF CEILING EXHAUST FAN FACE SIZE NEW R/A CEILING GRILLE MATERIAL FRAME FINISH DAMPER /A\ SUPPLY AIR CFM RANGE NOTES cFl DIFFUSER GRILLE DESIGNATION ® EXISTING S/A CEILING DIFFUSER SEE E / EXISTING RA CEILING GRILLE c RETURN /EXHAUST AIR DIFFUSER OR GRILLE DESIGNATION SLOT / LINEAR DIFFUSER EW- X EQUIPMENT TAG L_ VOLUME CONTROL DAMPER OT THERMOSTAT ► REDUCER OR INCREASER —� POC- POINT OF CONNECTION 4 -WAY NEW FLEX DUCT -- SUPPLY AIR LL_ Lf7 RETURN AIR SEE EXISTING FLEX DUCT d i v0- cu d -Mu /c DOOR UNDER CUT o NEW DUCTWORK B TITUS TMS AA 12X12 SCHEDULE A —A sHT. SECTION MARK OFF WHITE EXISTING DUCTWORK ;E� SHOE TAP DAMPER S "Z" BOOT TRANSFER DUCT D FIRE DAMPER U W AA DUCT SMOKE DETECTOR 24X24 BELLMOUTH TAP DD SEE PLAN OFF WHITE SIDEWALL EXHAUST FAN - NOT ALL SYMBOLS MAY - SEE NOTES APPLY TO THESE PLANS NUN I H KEY NOTES 0 EXISTING BATHROOM TO REMAIN AS IS. _(CLEAN DIFFUSERS OR REPLACE THEM IF NE ESSARY. VERIFY WITH ARCHITECT AND OWNER OCONTRACTOR TO VERIFY ALL EXISTING blICTWuTch & NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. O3 NEW CEILING IN THIS AREA. MECH. CONTRACTOR TO REPLACE ALL CEILING MOUNTED MECHANICAL EQUIPMENT WITH IMILAR EQUIPMENT AND WITH SAME OR BETTER PERFORMANCE. FIELD VERIFY. O NEW LOCATION OF EXISTING THERMOSTAT. ONEW DIFFUSER TO MATCH BUILDING STANDARD. SEE MECHANICAL SCHEDULE. 6O PROVIDE CABLE OPERATED VOLUME DAMPER. O DUCTWORK TO BE CAPPED. O8 EXISTING CHILLED WATER UNIT TO REMAIN AS IS. O9 EXISTING EXHAUST FAN TO REMAIN AS IS. 10 REPLACE EXISTING 6 "0 EXHAUST DUCTWORK WITH NEW GALVANIZED SHEET METAL DUCTWORK. LEGEND NEW wommonammumm EXISTING :A5E LINE ISSUED FOR PERMIT - ISSUED FOR CONSTRUCTION - KAMM CONSULTING PROJECT #: 2011 -0347 PROJECT MANAGER. Juan J. Bedaya ol mmwG Ar m m= m � 1407 West N JOB NO.: � ;, AIR DISTRIBUTION SCHEDULE 1.1025 TAG MANUF. & MODEL FACE SIZE NECK SIZE MATERIAL FRAME FINISH DAMPER THROW NC CFM RANGE NOTES SEE A TITUS TMS AA 24X24 SCHEDULE ALUM. SEE PLAN OFF WHITE - 4 -WAY MAX. 14 SEE SCH. SEE NOTES LL_ Lf7 c Q -p SEE d i v0- cu d oo N o (�\ B TITUS TMS AA 12X12 SCHEDULE I ALUM. SEE PLAN OFF WHITE - 4 -WAY MAX. 14 SEE SCH. SEE NOTES D U W AA TITUS 50F 24X24 SEE SCHEDULE ALUM. SEE PLAN OFF WHITE - - MAX. 14 - SEE NOTES 0 LL_ z 0 M /W Q V Lo W ( *) EQUIVALENT MANUFACTURER: METALAIRE, CARNES, T & B. NAILOR G ENEFAL NOTES 0 J 1. PROVIDE SPIN -IN COLLAR WITH VOLUME DAMPER AT TRUNK TO FLEX DUCT CONNECTION (SEE DETAIL). r M 2. PROVIDE TYPICAL 4 -WAY DIFFUSION, 2 -WAY OR 3 -WAY ONLY WHERE INDICATED ON PLANS. LU 3. REFER TO ARCHITECT PLANS FOR CEILING TYPE. 4. FINAL COLOR SELECTION SUBJECT TO ARCHITECT APPROVAL. W 0 5. FLEX DUCT SIZE TO BE SAME AS DIFFUSER NECK SIZE. 6. PROVIDE INSULATION ON THE BACK OF DIFFUSER IF IN UNCONDITIONED SPACE 7. PROVIDE VOLUME CONTROL DAMPERS FOR ALL RETURN GRILLES OR REGISTERS FOR BALANCED AIRFLOW. 8. DIFFUSERS & RETURN GRILLES TO BE MADE OF ALUMINUM. 8/A FLEX SCHEDULE 9. CONTRACTOR MUST SUBMIT CERTIFIED SUBMITTALS FOR ALL HVAC EQUIPMENT WHICH MUST BE APPROVED OE81t11 Z IROPORG= RRC}4T= W OMM PRIOR TO PURCHASE. 60" 50 -125 CFM SHEET N0: 80" 130 -200 CFM TI TLE: CONTRACTOR SHALL VERIFY WITH ARCHITECT AND TENANT /OWNER, 100" 205 -330 CFM MECHANICAL PLAN 11 1 PRIOR TO ANY PURCHASING OR INSTALLATION, IF A BULDING STANDARD HAS TO BE FOLLOWED REGARDING A SPECIFIC MODEL 120" 335 -450 CFM OR MANUFACTURER AND SHALL BRING ANY DISCREPANCY TO THE ATTENTION OF ENGINEER. 140" 455 -700 CFM ISSUED FOR PERMIT - ISSUED FOR CONSTRUCTION - KAMM CONSULTING PROJECT #: 2011 -0347 PROJECT MANAGER. Juan J. Bedaya ol mmwG Ar m m= m � 1407 West N JOB NO.: 1.1025 DRAWN /CHECKED BY: CML /DZK SCALE: AS NOTED ISSUE FOR: PERMIT 09/14/11 C5 �'� o CD c:) A M M 00 I Q N +> , �- _O aj LL_ Lf7 c Q -p X l� d i v0- cu d oo N o (�\ z�v- m Q) CD ON J A Q • — Vl� Lf') v D U W � u � H = a) -p U.— Q S U 0 LL_ z 0 M /W Q V Lo W cir) 0 J qt z Ld a .. r M LU z Z Ld _ > W 0 Q 0- <zm 5E Q Oro z =�0 Ld OE81t11 Z IROPORG= RRC}4T= W OMM SHEET N0: mloo TI TLE: MECHANICAL PLAN 11 1