11-516-047c
i�
I
L
M
r
M
N
IF
PLUMBING FIXTURE SCHEDULE
MARK
DESCRIPTION
SUPPLIED BY
INSTALLED BY
WASTE
VENT
H.W.
C.W.
MANUFACTURER
MODEL #
COLOR
REMARKS
P -1
WATER CLOSET (ACC.)
G.C. PLUMBER
G.C. PLUMBER
3'
2'
-
1"
AMERICAN STANDARD
MADERA 3043.102
WHITE
ELONGATED BOWL
DCV
SEAT
G.C. PLUMBER
- -
G.C. PLUMBER
- - -- - -- - - - - --
-
-
-
-
OLSONITE
#95
WHITE
OPEN FRONT SEAT LESS COVER
1 ALWAYS VERIFY BACKFLOW VALVE REQUIREMENTS AND APPROVAL FOR
FLUSH VALVE
G.C. PLUMBER
G.C. PLUMBER
-
-
-
-
ZURN
EXPOSED Z6000
CHROME PLATED
LOW CONSUMPTION (1.6 GPF)
P -2
WATER CLOSET
G.C. PLUMBER
G.C. PLUMBER
3'
2"
-
1"
AMERICAN STANDARD
MADERA 2234.015
WHITE
ELONGATED BOWL
G.C. PLUMBER
SEAT
G.C. PLUMBER
G.C. PLUMBER
--
-
-
-
OLSONITE
#95
WHITE
OPEN FRONT SEAT LESS COVER
-
FLUSH VALVE
G.C. PLUMBER
G.C. PLUMBER
-
-
-
-
ZURN
EXPOSED Z6000
CHROME PLATED
LOW CONSUMPTION (1.6 GPF)
P -3
URINAL
G.C. PLUMBER
G.C. PLUMBER
2"
1 -1/2"
PRE -RINSE UNIT
3/4"
AMERICAN STANDARD
WASHBROOK 6501.010
WHITE
MOUNT AT STANDARD WEIGHT
-
FLUSH VALVE
G.C. PLUMBER
G.C. PLUMBER
-
-
-
-
ZURN
EXPOSED 76003
CHROME PLATED
LOW CONSUMPTION (1.0 GPF)
P -3A
URINAL (ACC.)
G.C. PLUMBER
G.C. PLUMBER
2"
1 -1/2"
WASTE VALVE
3/4"
AMERICAN STANDARD
WASHBROOK 6501.010
WHITE
MOUNT AT ACCESSIBLE HEIGHT
P -8
FLUSH VALVE
G.C. PLUMBER
G.C. PLUMBER
-
-
-
-
ZURN
EXPOSED Z6003
CHROME PLATED
LOW CONSUMPTION (1.0 GPF)
P -4
COUNTERTOP SINK
MILLWRK VEND
MILLWRK VEND
1 -1/2'
1 -1/2"
1/2"
1/2"
CORIAM
-
810
GLACIER WHITE
OFFSET OVERFLOW
P -9
FAUCET
G.C. PLUMBER
G.C. PLUMBER
-
-
-
-
- - - - --
ELKAY
LK406GNO5174
CHROME PLATED
4" CENTERS, B" GOOSENECK, 0.5GPM MAX FLOW
EQUIP. VENDOR
GRID STRAINER
G.C. PLUMBER
G.C. PLUMBER
-
-
-
-°
SLOAN OPTIMA
ETF -460 -A
CHROME PLATED
W/ 1 -1/4" OUTLET TUBE
P -5
4 COMP. BAR SINK
EQUIP. VENDOR
G.C. PLUMBER
2" INDIR
-
1/2"
1/2'
-
-
-
SEE EQUIPMENT SCHEDULE
P -6
POT AND PAN SINK __...._.__.
EQUIP. VENDOR
G.C. PLUMBER
2" INDIR
-
3/4" (1400')
3/4`
-
-
-
SEE EQUIPMENT SCHEDULE
P -7
PRODUCE SINK
EQUIP. VENDOR
G.C. PLUMBER
2" INDIR
-
3/4" (140')
3/4"
-
-
--
SEE EQUIPMENT SCHEDULE
P -i
HAND WASH SINK
EQUIP. VENDOR
G.C. PLUMBER
1 -1/2"
1 -1/2
1/2"
1/2"
-
-
-
SEE EQUIPMENT SCHEDULE
P -9
MOP BASIN (24 "X36' )
G.C. PLUMBER
G.C. PLUMBER
2"
1 -1/2"
-
-
EL MUSTEE & SONS
65M
WHITE
WITH ELEVATED DRAIN SHELF
EQUIP. VENDOR
FAUCET
G.C. PLUMBER
G.C. PLUMBER
-
-
1/2"
1/2"
T&S
B- 0657 -01
POLISHED CHROME
MOUNT FAUCET AT 36"
P -13
CHEMICAL DISPENSER
EQUIP. VENDOR
EQUIP. VENDOR
-
-
1/2'
1/2"
-
-
-
PLUMBER TO PROVIDE: MIXING VALVE AND RPZ BFP
P-10
DUMP SINK
EQUIP. VENDOR
G.C. PLUMBER
1.5" INDIR
-
1/2"
1/2"
VERIFY LH /RH
WITH EQUIP VENDOR
-
SEE EQUIPMENT SCHEDULE
P -11
GLASS WASHER
EQUIP. VENDOR
G.C. PLUMBER
2" INDIR
-
1/2" (140')
1/2"
-
-
-
SEE EQUIPMENT SCHEDULE
P -12
DISHMACHINE
EQUIP. VENDOR
G.C. PLUMBER
2" INDIR
-
3/4" (140')
1/2"
-
-
-
W /DRAIN WATER TEMPERING KIT, SEE EQUIPMENT SCHEDULE
P -13
DUMP SINK / HAND
G.C. PLUMBER
G.C. PLUMBER
1.5" INDIR
-
1/2"
1/2"
-
-
-
SEE EQUIPMENT SCHEDULE. HAND SINK TO HAVE
WASH STATION
HANDS FREE WAND AND CHK VALVES ON WATER SUPPLY
P -14
DIPPER WELL
EQUIP. VENDOR
G.C. PLUMBER
1" INDIR
-
-
1/2"
DIPWELL
--
STAINLESS STEEL
DRAIN LINE FURNISHED AND INSTALLED BY G.C. PLUMBER
FD
FLOOR DRAIN (NON - PUBLIC)
G.C. PLUMBER
G.C, PLUMBER
3'
2"
-
-
WADE
1310
CAST IRON
UTILITY AREAS PROVIDE CAST IRON STRAINER
FD
FLOOR DRAIN (PUBLIC)
G.C. PLUMBER
G.C. PLUMBER
3"
2'
-
WADE
W1100
NICKEL BRONZE
PUBLIC AREAS PROVIDE NICKLE BRONZE STRAINER
FS
FLOOR SINK
G.C. PLUMBER
G.C. PLUMBER
- 3' _
2'
-
-
WADE
9130
BAKED ENAMEL
WITH ACID RESISTANT INTERIOR
TD
TRENCH DRAIN
G.C. PLUMBER
G.C. PLUMBER
3"
2"
-
-
ADVANCED TABCO
FTG1248
STAINLESS STEEL
HEAVY DUTY STAINLESS STEEL GRATE is STRAINER BASKET
HB
FROST PROOF HOSE BIBB
G.C. PLUMBER
G.C. PLUMBER
-
-
-
3/4"
WOODFORD
667
BRASS
NON - REMOVABLE ANTI - SIPHON DEVICE, LOSE KEY, BOX TYPE
GI
GEASE INTERCEPTOR
G.C. PLUMBER
G.C. PLUM DER
4"
2 "/3"
-
- -_-
-
- -_-_- - - - -. -....
SITE SPECIFIC
- -- -
SITE SPECIFIC
-- SITE _
SITE SPECIFIC
SW
SAMPLE WELL
G.C. PLUMBER
G.C. PLUMBER
-
--
-
-
SITE SPECIFIC
SITE SPECIFIC
SITE SPECIFIC
SAMPLE WELL FOR GREASE INTERCEPTOR
WF
WATER FILTRATION SYSTEM
EQUIP. VENDOR
G.C. PLUMBER
-
-
-
1"
-
-
-
SEE EQUIPMENT SCHEDULE
WH -1
WATER HEATER
G.C. PLUMBER
G.C. PLUMBER
_
-
1 -1/2"
1 -1/2"
A.O. SMITH
BTH -•250 XI
-
94% EXTRA HIGH EFFICIENCY
WS -1
WATER SOFTENER
EQUIP. VENDOR
G.C. PLUMBER
-
1 -1/2'
CUWGAN
HC -60
-
1" INDR
PIPING MATERIALS LEGEND
SEWER BELOW GRADE
CAST IRON
WASTE VENT ABOVE GRADE
SCHEDULE 40 PVC
COLD & HOT WATER (ABOVE GROUND)
ME 'L' COPPER
COLD WATER ( BURIED)
TYPE 'K' COPPER
GAS (ON ROOF)
SCHEDULE 40 BLACK IRON
GAS (INSIDE BUILDING)
SCHEDULE 40 BLACK IRON
CONDENSATE DRAIN
DWV COPPER
INDIRECT DRAIN (INSIDE BUILDING)
DWV COPPER
NOTE REFER TO PROJECT SPECIFICATION MANUAL
GAS DEMAND SCHEDULE
TAG
ITEM
DEMAND
BIU
119
4 BANK FRYER
366,000
120
3 BANK FRYER
488,000
121
CHAR BROILER
120,000
1 K
CONVECTION OVEN
44,000
GWH
GAS WATER HEATER
129,000
AND QUANTITIES OF POINT OF USE BACKFLOW PREVENTION PRIOR TO
PERFORMING WORK.
DESCRIPTION
TAG
VALVE MODEL
COFFEE / TEA BREWER
DCV
WATTS 3/4" # SD2 -FN
ECOLAB CHEMICAL DISPENSERS
-
TOTAL BTU DEMAND =
1,217,000
SEE KITCHEN EQUIPMENT PLANS FOR FINAL CONNECTION
REQUIREMENTS OF EQUIPMENT.
TOTAL DEVELOPED LENGTH OF TENANT SYSTEM = 35' -O'
2 PSI VEDIUM PRESSURE M
GAS PIPING SYSTEM SIZED FROM THE
PLUMBING CODE (2006 I.F.G.C..) TABLE 402.4(3)
LOW PRESSURE GAS (7 "WC /bz.)
GAS PIPING SYSTEM SIZED FROM THE
PLUMBING CODE (2006 I.F.G.C..) TABLE 402.4(2)
NOTE:
ALL COOKING SURFACES, KITCHEN EXHAUST SYSTEMS, GREASE
REMOVAL DEVICES AND HOODS SHALL BE PROTECTED WITH AN
APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEM AS SHOWN ON
KITCHEN AND HOOD DRAWINGS. THE ACTUATION OF THE FIRE
SUPPRESSION SYSTEM SHALL AUTOMATICALLY SHUT DOWN THE FUEL
SUPPLY TO THE COOKING EQUIPMENT AS SHOWN IN BOTH KITCHEN
AND PLUMBING DRAWINGS. THE FIRE SUPPRESSION SYSTEM SHALL
BE INTERLOCKED WITH THE GAS SOUNOID VALVES.
BACKFLOW PREVENTER SCHED
DESCRIPTION
TAG
VALVE MODEL
MAIN WATER SUPPLY
RPZ
WATTS 2" If 909M1 -S -QT
WATER FLITER CARBONATOR
RPZ
WATTS 1" f SS009QT -S
WATER SOFTENER
DCV
WATTS 1 1/2- # 007M2QT -S
ICE - MACHINE
DCV
WATTS 1/2- 1 SS007M3QT -S
INSTALL ADDITIONAL BACKFLOW PREVENTERS AT EQUIPMENT CONNECTIONS
FOR THE ITEMS LISTED BELOW WHEN REQUIRED BY LOCAL CODE.
CONTRACTOR TO FIELD VERIFY WITH LOCAL CODE OFFICIAL THE LOCATIONS
AND QUANTITIES OF POINT OF USE BACKFLOW PREVENTION PRIOR TO
PERFORMING WORK.
DESCRIPTION
TAG
VALVE MODEL
COFFEE / TEA BREWER
DCV
WATTS 3/4" # SD2 -FN
ECOLAB CHEMICAL DISPENSERS
RPZ
WATTS 1/2" # 009QT -S
HAND SINK
2. INSTALL MIXING VAVLE IN CABINET UNDER PLUMBING FIXTURE WHERE SHOWN.
CHECK VALVES
NOTE:
1. VERIFY MAIN WATER SUPPLY BACKFLOW PREVENTION REQUIREMENTS
WITH LOCAL CODE AT START OF CONSTRUCTION. PROVIDE BACKFLOW
PREVENTER ON MAIN SERVICE IF REQUIRED.
1 ALWAYS VERIFY BACKFLOW VALVE REQUIREMENTS AND APPROVAL FOR
ALL EQUIPMENT WITH AUTHORITIES HAVING JURISDICTION PRIOR TO
INSTALLATION
3. CARBONATOR TO HAVE STAINLESS STEEL RPZ VALVE.
4. PROVIDE Y STRAINERS FOR ALL RPZ VALVES.
5. ALL BACKFLOW PREVENTERS ON THE PROJECT NEW AND OR EXISTING
HAVE TO BE TESTED AND INSPECTED AS REQUIRED BY CODE AND THE
AUTHORITY HAVING JURISDICTION. PLUMBING CONTRACTOR TO PROVIDE
TESTING DOCUMENTATION TO THE OWNER OPERATOR FOR THEIR
RECORDS.
MIXING VALVE SCHEDULE MANUFACTURER: LAWLER
UNIT
MODEL
MIN
PSI LOSS
DISCHARGE
ASSE
NOTES:
NO.
2
GSM
AT 5 GPM
TEMP
APPROVALS
3 -COMP. SINK
MV -1
570
0.5
B
110 DEG F
1070, 1017
1,2,3,4
MV -2
516
0.5
12
110 DEG F
1016
1,2,3,4
NOTES:
1. NO SUBSTITUTIONS ALLOWED WITHOUT PRIOR APPROVAL FROM ENGINEER.
2. INSTALL MIXING VAVLE IN CABINET UNDER PLUMBING FIXTURE WHERE SHOWN.
3. INSTALL PER MANUFACTUER'S REQUIREMENTS.
4. PROVIDE DIAL TYPE THERMOMETER IN DISCHARGE WATER PIPING.
GREASE INTERCEPTOR SIZING
CALCULATION
MARK
DESCRIPTION
QTY.
TRAP
SIZE
D.F.U.
TOTAL
D.F.U.
[138/FS
HAND SINK KITCHEN
2
1.25
1.0
2.0 GW
EQUIP. VENDOR
3 -COMP. SINK
1
4"
6.0
6.0 GW
FAUCET
PRODUCE SINK
1
3"
5.0
5.0 GW
LAVATORIES
DIPPER WELL
1
3'
5.0
5.0 GW
DISHWASHER -
DISHWASHER
1
3"
5.0
5.0 GW
EQUIP. VENDOR
MOP SINK
1
3`
5.0
5.0 GW
POT & PAN SINK
COFFEPEA BREWERS
1
-
-
- GW
380 FD
WATER FILTER BEVERAGE STA.
1
3"
5.0
5.0 GW
B- 0133 -B
OR DRAIN (WALK-IN/MEAT)
1
3"
5.0
5.0 GW
G.C. PLUMBER
OR DRAIN EMGY KITCHEN
5
3'
0.0
0.0 GW
XTURE UNITS:
38.0 GW
rDF.
38.0 FU = 19 GPM (E QUAL TO 20 GPM /40 LOS CAPACITY REQUIRED)
NOTE: 2006 IPC, CH. 7, SEC. 709.3 - 1 GPM = 2 FIXTURE UNITS
15 -3950
1,500 GALLON INTERCEPTOR PROVIDED PER 2006 IPC
i
U Y Y V U V CS f U
EQUIPMENT SCHEDULE
MARK
#
DESCRIPTION
SUPPLIED BY
INSTALLED BY
MANUFACTURER
MODEL If
REMARKS "
P -5
106
4 COMP. BAR SINK
EQUIP. VENDOR
EQUIP. VENDOR
LACROSSE
SK74CD -BWW
G.C. PLUMBER TO MAKE FINAL CONNECTIONS
-
-
FAUCET
EQUIP. VENDOR
G.C. PLUMBER
LACROSSE
--
-�-
LAVATORIES
4
4 X 5 - 20
MOP SINK
1
1 X 10 = 10
DISHWASHER -
1
-
332,
CHEMICAL DISPENSER
EQUIP. VENDOR
EQUIP. VENDOR
ECOLAB
--
PLUMBER TO PROVIDE WATER TAP WITH 1/2- NPT h SHUT OFF VALVE AND RPZ BFF-
P -6
137
POT & PAN SINK
EQUIP. VENDOR
EQUIP. VENDOR
SELECT STAINLESS
8WW -3B1 524 -2D18
G.C. PLUMBER TO MAKE FINAL CONNECTIONS
-
-
PRE -RINSE UNIT
EQUIP. VENDOR
G.C. PLUMBER
T&S BRASS
B- 0133 -B
--
-
-
FAUCET
EQUIP. VENDOR
G.C. PLUMBER
T&S BRASS
8 -0156
--
-
-
WASTE VALVE
EQUIP. VENDOR
G.C. PLUMBER
T&S BRASS
15 -3950
-
-
331
CHEMICAL DISPENSER
EQUIP. VENDOR
EQUIP. VENDOR
ECOLAB
--
PLUMBER TO PROVIDE WATER TAP WITH 1/2- NPT is SHUT OFF VALVE AND RPZ BFP
P -7
138:
PRODUCE PREP SINK
EQUIP. VENDOR
EQUIP. VENDOR
SELECT STAINLESS
BWW- 1018 -018
G.C. PLUMBER TO MAKE FINAL CONNECTIONS
-
-
PRE -RINSE UNIT
EQUIP. VENDOR
G.C. PLUMBER
T&S BRASS
B- 0133 -8
--
-
-
SWING NOZZLE
EQUIP. VENDOR
G.C. PLUMBER
T &S BRASS
060X
--
HB
-
FAUCET
EQUIP. VENDOR
G.C. PLUMBER
T&S BRASS
3-- 0155 -LN
--
-
-
WASTE VALVE
EQUIP. VENDOR
G.C. PLUMBER
T&S BRASS
B -3950
--
P -8
107,
HAND WASH SINK
EQUIP, VENDOR
EQUIP. VENDOR
SELECT STAINLESS
3WW-PL-SHS-1-NF
G.C. PLUMBER TO MAKE FINAL CONNECTIONS
-
-
FAUCET
EQUIP. VENDOR
G.C. PLUMBER
T&S BRASS
B- 1146 -01
--
-
-
HANDS FREE WAND
EQUIP. VENDOR
G.C. PLUMBER
T&S BRASS
B- 0199 -23
PROVIDE CHECK VALVES ON WATER SUPPLIES
P -9
329
MOP SINK (24"X36`)
EQUIP. VENDOR
EQUIP. VENDOR
EL MUSTEE is SONS
65M
G.C. PLUMBER TO MAKE FINAL CONNECTIONS
.& __._..ND
-
330'
CHEMICAL DISPENSER
EQUIP. VENDOR
EQUIP. VENDOR
ECOLAO
- --
PLUMBER TO PROVIDE WATER TAP WITH 1/2" NPT SHUT OFF VALVE AND RPZ BFP
-10(R)
111 R
ICE BIN /BLENDER /DUMP SINK
EQUIP. VENDOR
EQUIP. VENDOR
LACROSSE
SK4- 241CRBWW +B
G.C. PLUMBER TO MAKE FINAL CONNECTIONS, MOUNT RECPTICAL HORIZ.
P -9 329
MOP SINK
RIGHT HANDED
3"
5.0
5.0 GW.
3.0
3.0
lip-1 -10(L)
111L
ICE BIN/BLENDER/DUMP SINK
EQUIP. VENDOR
EQUIP. VENDOR
LACROSSE
SK4- 241CLBWW +S
G.C. PLUMBER TO MAKE FINAL CONNECTIONS, MOUNT RECPTICAL HORIZ.
FD FOR (380) IWATER
FILTER BEVERAGE STA.
LEFT HANDED
3"
5.0
5.0 GW.
2.0
2.0
1
109
GLASS WASHER
EQUIP. VENDOR
EQUIP. VENDOR
HOBART
LXIC -6
G.C. PLUMBER TO MAKE FINAL CONNECTIONS
-
333
CHEMICAL DISPENSER
EQUIP. VENDOR
EQUIP. VENDOR
ECOLAB
--
PLUMBER TO PROVIDE WATER TAP WITH 1/2- NPT k SHUT OFF VALVE AND RPZ BFP
P -12
199
DISHMACHINE
EQUIP, VENDOR
EQUIP. VENDOR
HOBART
LXIH -4
G.C. PLUMBER TO MAKE FINAL CONNECTIONS
-
-
PRESSURE REGULATOR
EQUIP. VENDOR
G.C. PLUMBER
HOBART
PRESREC- 1 /20OR
--
-
-
6" LEGS
EQUIP. VENDOR
EQUIP. VENDOR
HOBART
BASE -LX
- -
-
-
DRAINWATER TEMPERING KIT
G.C. PLUMBER
G.C. PLUMBER
HOBART
ML- 130137
-
P -13
112
DUMP SINK/ HAND WASH
EQUIP. VENDOR
EQUIP. VENDOR
LACROSSE
SK3- H521R -BWW
- - - - - -- _._._._._ ..
HAND SINK TO HAVE HANDS FREE WAND AND CHK VALVES ON WATER SUPP LY
WF
380
WATER FILTER SYSTEM
EQUIP. VENDOR
G.C. PLUMBER
ECOLAB
EVERPURE
SERVICE FOR BEVERAGE DISPENSERS
WATER HEATER SIZING CALLS
FORMULA FOR MIXING HOT AND COLD WATER
j"- - X OF HOT WATER REQUIRED TO PRODUCE
H--C DESIRED MIXED TEMPERATURE
WHERE M = MIXED WATER TEMPERATURE
C - COLD WATER TEMPERATURE
H - HOT WATER TEMPERATURE
TEMPERATURE FACTORS -- COLD WATER
WHEN INCOMING MULTIPLY HOT WATER
COLD WATER IS LOAD BY
50' 0.90
60' 0.80
70' 0.70
GENERAL PURPOSE HOT WATER CONSUMPTION FOR VARIOUS KITCHEN
USAGES.
APPLICATION
QTY.
CONSUPTION (GPH)
4 -COMP BAR SINK
1
1 X 16 = 16
BLENDER STATION
2
2 X 5 = 10
DUMP SINK k HAND SINK
2
2 X 5 - 10
3 -COMP POT SINK
1
1 X 59 - 59
PRODUCE SINK
1
1 X 5= 5
HAND SINKS
3
3 X 5 - 15
LAVATORIES
4
4 X 5 - 20
MOP SINK
1
1 X 10 = 10
DISHWASHER -
1
1 X 29.8 - 28.8
GLASSWASHER -
1
1 X 28.8 - 28.8
TOTAL CONSUMPTION - 203 GPH REQ'D • 100'F RISE
TOTAL
CONSUMPTION
TEMP.
FACTOR
TOTAL
GPH REQUIRED
203 GPH
X 0.90
163-0 • 90' RISE
WATER HEATER SELECTED PROVIDES - 230 GPH • 100'F RISE
FIXTURE UNIT COUNT IPC 20068
MARK ITEM
DESCRIPTION
QTY.
PATRICK
V
ffy�yy... C
�.1 BLCES
, .
W.S.F.U.
PATRICK G.
BLEFS, , ARCHITECT
-
WATER CLOSET FL VALVE
WVVV VV..
0 2ND S UITE 30'r
-
N%iUP0LIS `I•I N v 55401
16.0 SAN.
PHONE:
(612) 338 -6677
P -3, P -3a
FAX:
2
(61 2) 338 -2995
_a
E -MAIL:
InfoOcmaroh.com
FIXTURE UNIT COUNT IPC 20068
MARK ITEM
DESCRIPTION
QTY.
SIZE
D.F.U.
TOTAL
D.F.U.
W.S.F.U.
P -1, P -2
WATER CLOSET FL VALVE
4
-
4.0
16.0 SAN.
10.0
0.55 -
P -3, P -3a
URINAL FL VALVE
2
-
2.0
4.0 SAN.
5.0
i]2
P -4
LAVATORY
4
1.25"
1.0
4.0 SAN.
2.0
FD
FLOOR DRAIN
10
3'
0.0
0.0 SAN.
-
4.19
FS FOR P -5 106
4 -COMP. BARSINK 2 FAUCETS
1
4'
6.0
6.0 SAN.
4.0
P -i 107
HAND SINK (BAR)-
1
1"
SHARED
-
2.0
F5 FOR P -11 109
GLASS WASHER BAR
1
3'
5.0
5.0 SAN.
4.0
4.0
FS FOR P -10 111
BLENDER STA BAR
2
3"
5.0
10.0 SAN.
2.0
4.0
FS FOR P -10 112
HANK SINK DUMP SINK BAR
2
3'
5.0
10.0 SAN.
2.0
4.0
FS
FLOOR SINK (W.H. /WTR. SFT.)
1
4"
6.0
6.0 SAN.
-
-
FS
FLOOR SINK WAIT STATION
3
3"
5.0
15.0 SAN.
-
-
FTD
TROUGH DRAIN ICE MACHINE
1
3'
5.0
5.0 SAN.
-
-
HB
HOSE BIB
2
-
-
-
0.0
0.0
P -i 107)
HAND SINK KITCHEN
2
1,25"
1.0
2.0 GW.
2.0
4.0
FS FOR P -6 137
3 -COMP. SINK
1 1
4"
6.0
6.0 GW.
4.0
4.0
FS FOR P -7 138
PRODUCE SINK
1 1
3'
5.0
5.0 GW.
4.0
4.0
FS FOR 194
DIPPER WELL
0
3"
1. 5.0
0.0 GW.
1.0
1.0
FS FOR P -12 199
DISHWASHER
1
3"
1 5.0
5.0 GW.
410
4 -.0
P -9 329
MOP SINK
1
3"
5.0
5.0 GW.
3.0
3.0
334
COFFEE BREWERS
1
-
-
-
1.b
1.0
FD FOR (380) IWATER
FILTER BEVERAGE STA.
1
3"
5.0
5.0 GW.
2.0
2.0
FD IFLOOR
DRAIN EMGY KITCHEN
4
3"
0.0
0.0 GW.
-
-
TOTAL FIXTURE UNITS:
1.0 SAN.
28.0 GW
103.0 0
103.
W.S.F.U.
103.0 FU = 70 GPM 2" METER AND WATER SERVICE ABLE E103.3(3)
D.F.U.
109.0 FU = 4" PIPING HORIZONTAL A 1/4" PER FOOT SLOPE (216 FU MAX.)
CONSULTANTS:
JAMES H. ART, P.E.
305 2ND ST NW, SUITE 105
NEW BRIGHTON, MN 55112
PHONE: (651) 632 -2300
FAX: (651) 632-2397 .
SEAL:
01111 111,jII16#
't�S
C E M 9•�g�'
No 63147 rl
STATE OF
C3 .
<<l�t�eetN�A��
I HEREBY CERTIFY THAT THE
PORTION OF THIS TECHNICAL
SUBMISSION DESCRIBED BELOW
WAS PREPARED BY ME OR UNDER
MY DIRECT SUPERVISION AND
RESPONSIBLE CHARGE. I AM A
DULY REGISTERED ENGINEER UNDER
THE LAWS OF THE STATE FLORIDA.
.LAMES H. ART
MAY 20, 2011 h°
DATE ISSUED
63167
F :EG. N0.
BLS _
BUFFALO WILD WINOS
CONSTRUCTION DEPARTMENT
5500 WAYZATA BLVD., STE 1600
MINNEAPOLIS, MN 55413
PHONE (952) 593 -0943 FAX (952) 593 -9777
EDMOND FA ARAN
THE SHOPS AT SUNSET PLACE
5701 SUNSET DRIVE; §1313A
SOUTH MIAMI, FL',33143
FRANCHISEE:
SETH DEKANTER
EMAIL_ ssth4Nc8'i etmsl!.com
y FRANCHISE .STOKE
SHEET TITLE:
PLUMBINS SCHEDULES
ET
)
WATER CALCULATIONS,
(2006 IPC) APPENDIX 'E'm
REVISioris:
DOMESTIC WATER SERVICE = 2" WATER METER AND 2" BLDG. PIPING
102.0 WSFU = 70 GPM - ON FLUSH VALVE SYSTEM - TABLE El 03.3(3)
CIO: DATE: ..
i
70 GPM = 0.55 PSI LOSS - FOR DISK TYPE 2" TAP /METER - TABLE El 03.3(4)
AVAIWLE PRESSURE APPROXIMATE -
6565 *
PSI
PRESS. LOSS ACROSS METER LOSS -
0.55 -
-PSI
STATIC PRESS. LOST (ELEV.) LOSS -
7.74
PSI
(1i' -0" X 0.43)
PROTECT NO:
1113:.001
GOVERNING FIXTURE - WATER CLOSET LOSS -
25
PSI
BACKFLOW PREVENTER - (2" RPZ) LOSS -
10 '
PSI
TOTAL PRESSURE AVAILABLE
21.71
PSI
DISTANCE FROM METER TO LAST FIXTURE
415'
5770.11
TOTAL DEVELOPED LENGTH OF SYSTEM (X 1.25)
518'
ALLOW. PRESS. 21.71 Y 100'
4.19
PSI
LOSS /100 FT. 511'
AVERAGE PRESS. DROP AVAILABLE FOR FRICTION
4.1'9
PSI
FRICTION LOSS -LBS. PER SO. IN. HEAD PER 100 -FOOT LENGTH
4.0
PSI
SMOOTH PIPE -- FIGURE E103.3(2) VELOCITY = 7.0 FPS
t
�r
.,,
*ny„
v
V14
C
iA ,
i
REVISioris:
�....
CIO: DATE: ..
i
BY.
i
I
: I
f'
PROTECT NO:
1113:.001
DRAWN BY
Mnl3
P400
5770.11
Em ml COPYRIGHT PATRICK G. BLEE:S, AIA 2011
t
�r
.,,
*ny„
v
V14
C
iA ,
i