11-516-047c i� I L M r M N IF PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION SUPPLIED BY INSTALLED BY WASTE VENT H.W. C.W. MANUFACTURER MODEL # COLOR REMARKS P -1 WATER CLOSET (ACC.) G.C. PLUMBER G.C. PLUMBER 3' 2' - 1" AMERICAN STANDARD MADERA 3043.102 WHITE ELONGATED BOWL DCV SEAT G.C. PLUMBER - - G.C. PLUMBER - - -- - -- - - - - -- - - - - OLSONITE #95 WHITE OPEN FRONT SEAT LESS COVER 1 ALWAYS VERIFY BACKFLOW VALVE REQUIREMENTS AND APPROVAL FOR FLUSH VALVE G.C. PLUMBER G.C. PLUMBER - - - - ZURN EXPOSED Z6000 CHROME PLATED LOW CONSUMPTION (1.6 GPF) P -2 WATER CLOSET G.C. PLUMBER G.C. PLUMBER 3' 2" - 1" AMERICAN STANDARD MADERA 2234.015 WHITE ELONGATED BOWL G.C. PLUMBER SEAT G.C. PLUMBER G.C. PLUMBER -- - - - OLSONITE #95 WHITE OPEN FRONT SEAT LESS COVER - FLUSH VALVE G.C. PLUMBER G.C. PLUMBER - - - - ZURN EXPOSED Z6000 CHROME PLATED LOW CONSUMPTION (1.6 GPF) P -3 URINAL G.C. PLUMBER G.C. PLUMBER 2" 1 -1/2" PRE -RINSE UNIT 3/4" AMERICAN STANDARD WASHBROOK 6501.010 WHITE MOUNT AT STANDARD WEIGHT - FLUSH VALVE G.C. PLUMBER G.C. PLUMBER - - - - ZURN EXPOSED 76003 CHROME PLATED LOW CONSUMPTION (1.0 GPF) P -3A URINAL (ACC.) G.C. PLUMBER G.C. PLUMBER 2" 1 -1/2" WASTE VALVE 3/4" AMERICAN STANDARD WASHBROOK 6501.010 WHITE MOUNT AT ACCESSIBLE HEIGHT P -8 FLUSH VALVE G.C. PLUMBER G.C. PLUMBER - - - - ZURN EXPOSED Z6003 CHROME PLATED LOW CONSUMPTION (1.0 GPF) P -4 COUNTERTOP SINK MILLWRK VEND MILLWRK VEND 1 -1/2' 1 -1/2" 1/2" 1/2" CORIAM - 810 GLACIER WHITE OFFSET OVERFLOW P -9 FAUCET G.C. PLUMBER G.C. PLUMBER - - - - - - - - -- ELKAY LK406GNO5174 CHROME PLATED 4" CENTERS, B" GOOSENECK, 0.5GPM MAX FLOW EQUIP. VENDOR GRID STRAINER G.C. PLUMBER G.C. PLUMBER - - - -° SLOAN OPTIMA ETF -460 -A CHROME PLATED W/ 1 -1/4" OUTLET TUBE P -5 4 COMP. BAR SINK EQUIP. VENDOR G.C. PLUMBER 2" INDIR - 1/2" 1/2' - - - SEE EQUIPMENT SCHEDULE P -6 POT AND PAN SINK __...._.__. EQUIP. VENDOR G.C. PLUMBER 2" INDIR - 3/4" (1400') 3/4` - - - SEE EQUIPMENT SCHEDULE P -7 PRODUCE SINK EQUIP. VENDOR G.C. PLUMBER 2" INDIR - 3/4" (140') 3/4" - - -- SEE EQUIPMENT SCHEDULE P -i HAND WASH SINK EQUIP. VENDOR G.C. PLUMBER 1 -1/2" 1 -1/2 1/2" 1/2" - - - SEE EQUIPMENT SCHEDULE P -9 MOP BASIN (24 "X36' ) G.C. PLUMBER G.C. PLUMBER 2" 1 -1/2" - - EL MUSTEE & SONS 65M WHITE WITH ELEVATED DRAIN SHELF EQUIP. VENDOR FAUCET G.C. PLUMBER G.C. PLUMBER - - 1/2" 1/2" T&S B- 0657 -01 POLISHED CHROME MOUNT FAUCET AT 36" P -13 CHEMICAL DISPENSER EQUIP. VENDOR EQUIP. VENDOR - - 1/2' 1/2" - - - PLUMBER TO PROVIDE: MIXING VALVE AND RPZ BFP P-10 DUMP SINK EQUIP. VENDOR G.C. PLUMBER 1.5" INDIR - 1/2" 1/2" VERIFY LH /RH WITH EQUIP VENDOR - SEE EQUIPMENT SCHEDULE P -11 GLASS WASHER EQUIP. VENDOR G.C. PLUMBER 2" INDIR - 1/2" (140') 1/2" - - - SEE EQUIPMENT SCHEDULE P -12 DISHMACHINE EQUIP. VENDOR G.C. PLUMBER 2" INDIR - 3/4" (140') 1/2" - - - W /DRAIN WATER TEMPERING KIT, SEE EQUIPMENT SCHEDULE P -13 DUMP SINK / HAND G.C. PLUMBER G.C. PLUMBER 1.5" INDIR - 1/2" 1/2" - - - SEE EQUIPMENT SCHEDULE. HAND SINK TO HAVE WASH STATION HANDS FREE WAND AND CHK VALVES ON WATER SUPPLY P -14 DIPPER WELL EQUIP. VENDOR G.C. PLUMBER 1" INDIR - - 1/2" DIPWELL -- STAINLESS STEEL DRAIN LINE FURNISHED AND INSTALLED BY G.C. PLUMBER FD FLOOR DRAIN (NON - PUBLIC) G.C. PLUMBER G.C, PLUMBER 3' 2" - - WADE 1310 CAST IRON UTILITY AREAS PROVIDE CAST IRON STRAINER FD FLOOR DRAIN (PUBLIC) G.C. PLUMBER G.C. PLUMBER 3" 2' - WADE W1100 NICKEL BRONZE PUBLIC AREAS PROVIDE NICKLE BRONZE STRAINER FS FLOOR SINK G.C. PLUMBER G.C. PLUMBER - 3' _ 2' - - WADE 9130 BAKED ENAMEL WITH ACID RESISTANT INTERIOR TD TRENCH DRAIN G.C. PLUMBER G.C. PLUMBER 3" 2" - - ADVANCED TABCO FTG1248 STAINLESS STEEL HEAVY DUTY STAINLESS STEEL GRATE is STRAINER BASKET HB FROST PROOF HOSE BIBB G.C. PLUMBER G.C. PLUMBER - - - 3/4" WOODFORD 667 BRASS NON - REMOVABLE ANTI - SIPHON DEVICE, LOSE KEY, BOX TYPE GI GEASE INTERCEPTOR G.C. PLUMBER G.C. PLUM DER 4" 2 "/3" - - -_- - - -_-_- - - - -. -.... SITE SPECIFIC - -- - SITE SPECIFIC -- SITE _ SITE SPECIFIC SW SAMPLE WELL G.C. PLUMBER G.C. PLUMBER - -- - - SITE SPECIFIC SITE SPECIFIC SITE SPECIFIC SAMPLE WELL FOR GREASE INTERCEPTOR WF WATER FILTRATION SYSTEM EQUIP. VENDOR G.C. PLUMBER - - - 1" - - - SEE EQUIPMENT SCHEDULE WH -1 WATER HEATER G.C. PLUMBER G.C. PLUMBER _ - 1 -1/2" 1 -1/2" A.O. SMITH BTH -•250 XI - 94% EXTRA HIGH EFFICIENCY WS -1 WATER SOFTENER EQUIP. VENDOR G.C. PLUMBER - 1 -1/2' CUWGAN HC -60 - 1" INDR PIPING MATERIALS LEGEND SEWER BELOW GRADE CAST IRON WASTE VENT ABOVE GRADE SCHEDULE 40 PVC COLD & HOT WATER (ABOVE GROUND) ME 'L' COPPER COLD WATER ( BURIED) TYPE 'K' COPPER GAS (ON ROOF) SCHEDULE 40 BLACK IRON GAS (INSIDE BUILDING) SCHEDULE 40 BLACK IRON CONDENSATE DRAIN DWV COPPER INDIRECT DRAIN (INSIDE BUILDING) DWV COPPER NOTE REFER TO PROJECT SPECIFICATION MANUAL GAS DEMAND SCHEDULE TAG ITEM DEMAND BIU 119 4 BANK FRYER 366,000 120 3 BANK FRYER 488,000 121 CHAR BROILER 120,000 1 K CONVECTION OVEN 44,000 GWH GAS WATER HEATER 129,000 AND QUANTITIES OF POINT OF USE BACKFLOW PREVENTION PRIOR TO PERFORMING WORK. DESCRIPTION TAG VALVE MODEL COFFEE / TEA BREWER DCV WATTS 3/4" # SD2 -FN ECOLAB CHEMICAL DISPENSERS - TOTAL BTU DEMAND = 1,217,000 SEE KITCHEN EQUIPMENT PLANS FOR FINAL CONNECTION REQUIREMENTS OF EQUIPMENT. TOTAL DEVELOPED LENGTH OF TENANT SYSTEM = 35' -O' 2 PSI VEDIUM PRESSURE M GAS PIPING SYSTEM SIZED FROM THE PLUMBING CODE (2006 I.F.G.C..) TABLE 402.4(3) LOW PRESSURE GAS (7 "WC /bz.) GAS PIPING SYSTEM SIZED FROM THE PLUMBING CODE (2006 I.F.G.C..) TABLE 402.4(2) NOTE: ALL COOKING SURFACES, KITCHEN EXHAUST SYSTEMS, GREASE REMOVAL DEVICES AND HOODS SHALL BE PROTECTED WITH AN APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEM AS SHOWN ON KITCHEN AND HOOD DRAWINGS. THE ACTUATION OF THE FIRE SUPPRESSION SYSTEM SHALL AUTOMATICALLY SHUT DOWN THE FUEL SUPPLY TO THE COOKING EQUIPMENT AS SHOWN IN BOTH KITCHEN AND PLUMBING DRAWINGS. THE FIRE SUPPRESSION SYSTEM SHALL BE INTERLOCKED WITH THE GAS SOUNOID VALVES. BACKFLOW PREVENTER SCHED DESCRIPTION TAG VALVE MODEL MAIN WATER SUPPLY RPZ WATTS 2" If 909M1 -S -QT WATER FLITER CARBONATOR RPZ WATTS 1" f SS009QT -S WATER SOFTENER DCV WATTS 1 1/2- # 007M2QT -S ICE - MACHINE DCV WATTS 1/2- 1 SS007M3QT -S INSTALL ADDITIONAL BACKFLOW PREVENTERS AT EQUIPMENT CONNECTIONS FOR THE ITEMS LISTED BELOW WHEN REQUIRED BY LOCAL CODE. CONTRACTOR TO FIELD VERIFY WITH LOCAL CODE OFFICIAL THE LOCATIONS AND QUANTITIES OF POINT OF USE BACKFLOW PREVENTION PRIOR TO PERFORMING WORK. DESCRIPTION TAG VALVE MODEL COFFEE / TEA BREWER DCV WATTS 3/4" # SD2 -FN ECOLAB CHEMICAL DISPENSERS RPZ WATTS 1/2" # 009QT -S HAND SINK 2. INSTALL MIXING VAVLE IN CABINET UNDER PLUMBING FIXTURE WHERE SHOWN. CHECK VALVES NOTE: 1. VERIFY MAIN WATER SUPPLY BACKFLOW PREVENTION REQUIREMENTS WITH LOCAL CODE AT START OF CONSTRUCTION. PROVIDE BACKFLOW PREVENTER ON MAIN SERVICE IF REQUIRED. 1 ALWAYS VERIFY BACKFLOW VALVE REQUIREMENTS AND APPROVAL FOR ALL EQUIPMENT WITH AUTHORITIES HAVING JURISDICTION PRIOR TO INSTALLATION 3. CARBONATOR TO HAVE STAINLESS STEEL RPZ VALVE. 4. PROVIDE Y STRAINERS FOR ALL RPZ VALVES. 5. ALL BACKFLOW PREVENTERS ON THE PROJECT NEW AND OR EXISTING HAVE TO BE TESTED AND INSPECTED AS REQUIRED BY CODE AND THE AUTHORITY HAVING JURISDICTION. PLUMBING CONTRACTOR TO PROVIDE TESTING DOCUMENTATION TO THE OWNER OPERATOR FOR THEIR RECORDS. MIXING VALVE SCHEDULE MANUFACTURER: LAWLER UNIT MODEL MIN PSI LOSS DISCHARGE ASSE NOTES: NO. 2 GSM AT 5 GPM TEMP APPROVALS 3 -COMP. SINK MV -1 570 0.5 B 110 DEG F 1070, 1017 1,2,3,4 MV -2 516 0.5 12 110 DEG F 1016 1,2,3,4 NOTES: 1. NO SUBSTITUTIONS ALLOWED WITHOUT PRIOR APPROVAL FROM ENGINEER. 2. INSTALL MIXING VAVLE IN CABINET UNDER PLUMBING FIXTURE WHERE SHOWN. 3. INSTALL PER MANUFACTUER'S REQUIREMENTS. 4. PROVIDE DIAL TYPE THERMOMETER IN DISCHARGE WATER PIPING. GREASE INTERCEPTOR SIZING CALCULATION MARK DESCRIPTION QTY. TRAP SIZE D.F.U. TOTAL D.F.U. [138/FS HAND SINK KITCHEN 2 1.25 1.0 2.0 GW EQUIP. VENDOR 3 -COMP. SINK 1 4" 6.0 6.0 GW FAUCET PRODUCE SINK 1 3" 5.0 5.0 GW LAVATORIES DIPPER WELL 1 3' 5.0 5.0 GW DISHWASHER - DISHWASHER 1 3" 5.0 5.0 GW EQUIP. VENDOR MOP SINK 1 3` 5.0 5.0 GW POT & PAN SINK COFFEPEA BREWERS 1 - - - GW 380 FD WATER FILTER BEVERAGE STA. 1 3" 5.0 5.0 GW B- 0133 -B OR DRAIN (WALK-IN/MEAT) 1 3" 5.0 5.0 GW G.C. PLUMBER OR DRAIN EMGY KITCHEN 5 3' 0.0 0.0 GW XTURE UNITS: 38.0 GW rDF. 38.0 FU = 19 GPM (E QUAL TO 20 GPM /40 LOS CAPACITY REQUIRED) NOTE: 2006 IPC, CH. 7, SEC. 709.3 - 1 GPM = 2 FIXTURE UNITS 15 -3950 1,500 GALLON INTERCEPTOR PROVIDED PER 2006 IPC i U Y Y V U V CS f U EQUIPMENT SCHEDULE MARK # DESCRIPTION SUPPLIED BY INSTALLED BY MANUFACTURER MODEL If REMARKS " P -5 106 4 COMP. BAR SINK EQUIP. VENDOR EQUIP. VENDOR LACROSSE SK74CD -BWW G.C. PLUMBER TO MAKE FINAL CONNECTIONS - - FAUCET EQUIP. VENDOR G.C. PLUMBER LACROSSE -- -�- LAVATORIES 4 4 X 5 - 20 MOP SINK 1 1 X 10 = 10 DISHWASHER - 1 - 332, CHEMICAL DISPENSER EQUIP. VENDOR EQUIP. VENDOR ECOLAB -- PLUMBER TO PROVIDE WATER TAP WITH 1/2- NPT h SHUT OFF VALVE AND RPZ BFF- P -6 137 POT & PAN SINK EQUIP. VENDOR EQUIP. VENDOR SELECT STAINLESS 8WW -3B1 524 -2D18 G.C. PLUMBER TO MAKE FINAL CONNECTIONS - - PRE -RINSE UNIT EQUIP. VENDOR G.C. PLUMBER T&S BRASS B- 0133 -B -- - - FAUCET EQUIP. VENDOR G.C. PLUMBER T&S BRASS 8 -0156 -- - - WASTE VALVE EQUIP. VENDOR G.C. PLUMBER T&S BRASS 15 -3950 - - 331 CHEMICAL DISPENSER EQUIP. VENDOR EQUIP. VENDOR ECOLAB -- PLUMBER TO PROVIDE WATER TAP WITH 1/2- NPT is SHUT OFF VALVE AND RPZ BFP P -7 138: PRODUCE PREP SINK EQUIP. VENDOR EQUIP. VENDOR SELECT STAINLESS BWW- 1018 -018 G.C. PLUMBER TO MAKE FINAL CONNECTIONS - - PRE -RINSE UNIT EQUIP. VENDOR G.C. PLUMBER T&S BRASS B- 0133 -8 -- - - SWING NOZZLE EQUIP. VENDOR G.C. PLUMBER T &S BRASS 060X -- HB - FAUCET EQUIP. VENDOR G.C. PLUMBER T&S BRASS 3-- 0155 -LN -- - - WASTE VALVE EQUIP. VENDOR G.C. PLUMBER T&S BRASS B -3950 -- P -8 107, HAND WASH SINK EQUIP, VENDOR EQUIP. VENDOR SELECT STAINLESS 3WW-PL-SHS-1-NF G.C. PLUMBER TO MAKE FINAL CONNECTIONS - - FAUCET EQUIP. VENDOR G.C. PLUMBER T&S BRASS B- 1146 -01 -- - - HANDS FREE WAND EQUIP. VENDOR G.C. PLUMBER T&S BRASS B- 0199 -23 PROVIDE CHECK VALVES ON WATER SUPPLIES P -9 329 MOP SINK (24"X36`) EQUIP. VENDOR EQUIP. VENDOR EL MUSTEE is SONS 65M G.C. PLUMBER TO MAKE FINAL CONNECTIONS .& __._..ND - 330' CHEMICAL DISPENSER EQUIP. VENDOR EQUIP. VENDOR ECOLAO - -- PLUMBER TO PROVIDE WATER TAP WITH 1/2" NPT SHUT OFF VALVE AND RPZ BFP -10(R) 111 R ICE BIN /BLENDER /DUMP SINK EQUIP. VENDOR EQUIP. VENDOR LACROSSE SK4- 241CRBWW +B G.C. PLUMBER TO MAKE FINAL CONNECTIONS, MOUNT RECPTICAL HORIZ. P -9 329 MOP SINK RIGHT HANDED 3" 5.0 5.0 GW. 3.0 3.0 lip-1 -10(L) 111L ICE BIN/BLENDER/DUMP SINK EQUIP. VENDOR EQUIP. VENDOR LACROSSE SK4- 241CLBWW +S G.C. PLUMBER TO MAKE FINAL CONNECTIONS, MOUNT RECPTICAL HORIZ. FD FOR (380) IWATER FILTER BEVERAGE STA. LEFT HANDED 3" 5.0 5.0 GW. 2.0 2.0 1 109 GLASS WASHER EQUIP. VENDOR EQUIP. VENDOR HOBART LXIC -6 G.C. PLUMBER TO MAKE FINAL CONNECTIONS - 333 CHEMICAL DISPENSER EQUIP. VENDOR EQUIP. VENDOR ECOLAB -- PLUMBER TO PROVIDE WATER TAP WITH 1/2- NPT k SHUT OFF VALVE AND RPZ BFP P -12 199 DISHMACHINE EQUIP, VENDOR EQUIP. VENDOR HOBART LXIH -4 G.C. PLUMBER TO MAKE FINAL CONNECTIONS - - PRESSURE REGULATOR EQUIP. VENDOR G.C. PLUMBER HOBART PRESREC- 1 /20OR -- - - 6" LEGS EQUIP. VENDOR EQUIP. VENDOR HOBART BASE -LX - - - - DRAINWATER TEMPERING KIT G.C. PLUMBER G.C. PLUMBER HOBART ML- 130137 - P -13 112 DUMP SINK/ HAND WASH EQUIP. VENDOR EQUIP. VENDOR LACROSSE SK3- H521R -BWW - - - - - -- _._._._._ .. HAND SINK TO HAVE HANDS FREE WAND AND CHK VALVES ON WATER SUPP LY WF 380 WATER FILTER SYSTEM EQUIP. VENDOR G.C. PLUMBER ECOLAB EVERPURE SERVICE FOR BEVERAGE DISPENSERS WATER HEATER SIZING CALLS FORMULA FOR MIXING HOT AND COLD WATER j"- - X OF HOT WATER REQUIRED TO PRODUCE H--C DESIRED MIXED TEMPERATURE WHERE M = MIXED WATER TEMPERATURE C - COLD WATER TEMPERATURE H - HOT WATER TEMPERATURE TEMPERATURE FACTORS -- COLD WATER WHEN INCOMING MULTIPLY HOT WATER COLD WATER IS LOAD BY 50' 0.90 60' 0.80 70' 0.70 GENERAL PURPOSE HOT WATER CONSUMPTION FOR VARIOUS KITCHEN USAGES. APPLICATION QTY. CONSUPTION (GPH) 4 -COMP BAR SINK 1 1 X 16 = 16 BLENDER STATION 2 2 X 5 = 10 DUMP SINK k HAND SINK 2 2 X 5 - 10 3 -COMP POT SINK 1 1 X 59 - 59 PRODUCE SINK 1 1 X 5= 5 HAND SINKS 3 3 X 5 - 15 LAVATORIES 4 4 X 5 - 20 MOP SINK 1 1 X 10 = 10 DISHWASHER - 1 1 X 29.8 - 28.8 GLASSWASHER - 1 1 X 28.8 - 28.8 TOTAL CONSUMPTION - 203 GPH REQ'D • 100'F RISE TOTAL CONSUMPTION TEMP. FACTOR TOTAL GPH REQUIRED 203 GPH X 0.90 163-0 • 90' RISE WATER HEATER SELECTED PROVIDES - 230 GPH • 100'F RISE FIXTURE UNIT COUNT IPC 20068 MARK ITEM DESCRIPTION QTY. PATRICK V ffy�yy... C �.1 BLCES , . W.S.F.U. PATRICK G. BLEFS, , ARCHITECT - WATER CLOSET FL VALVE WVVV VV.. 0 2ND S UITE 30'r - N%iUP0LIS `I•I N v 55401 16.0 SAN. PHONE: (612) 338 -6677 P -3, P -3a FAX: 2 (61 2) 338 -2995 _a E -MAIL: InfoOcmaroh.com FIXTURE UNIT COUNT IPC 20068 MARK ITEM DESCRIPTION QTY. SIZE D.F.U. TOTAL D.F.U. W.S.F.U. P -1, P -2 WATER CLOSET FL VALVE 4 - 4.0 16.0 SAN. 10.0 0.55 - P -3, P -3a URINAL FL VALVE 2 - 2.0 4.0 SAN. 5.0 i]2 P -4 LAVATORY 4 1.25" 1.0 4.0 SAN. 2.0 FD FLOOR DRAIN 10 3' 0.0 0.0 SAN. - 4.19 FS FOR P -5 106 4 -COMP. BARSINK 2 FAUCETS 1 4' 6.0 6.0 SAN. 4.0 P -i 107 HAND SINK (BAR)- 1 1" SHARED - 2.0 F5 FOR P -11 109 GLASS WASHER BAR 1 3' 5.0 5.0 SAN. 4.0 4.0 FS FOR P -10 111 BLENDER STA BAR 2 3" 5.0 10.0 SAN. 2.0 4.0 FS FOR P -10 112 HANK SINK DUMP SINK BAR 2 3' 5.0 10.0 SAN. 2.0 4.0 FS FLOOR SINK (W.H. /WTR. SFT.) 1 4" 6.0 6.0 SAN. - - FS FLOOR SINK WAIT STATION 3 3" 5.0 15.0 SAN. - - FTD TROUGH DRAIN ICE MACHINE 1 3' 5.0 5.0 SAN. - - HB HOSE BIB 2 - - - 0.0 0.0 P -i 107) HAND SINK KITCHEN 2 1,25" 1.0 2.0 GW. 2.0 4.0 FS FOR P -6 137 3 -COMP. SINK 1 1 4" 6.0 6.0 GW. 4.0 4.0 FS FOR P -7 138 PRODUCE SINK 1 1 3' 5.0 5.0 GW. 4.0 4.0 FS FOR 194 DIPPER WELL 0 3" 1. 5.0 0.0 GW. 1.0 1.0 FS FOR P -12 199 DISHWASHER 1 3" 1 5.0 5.0 GW. 410 4 -.0 P -9 329 MOP SINK 1 3" 5.0 5.0 GW. 3.0 3.0 334 COFFEE BREWERS 1 - - - 1.b 1.0 FD FOR (380) IWATER FILTER BEVERAGE STA. 1 3" 5.0 5.0 GW. 2.0 2.0 FD IFLOOR DRAIN EMGY KITCHEN 4 3" 0.0 0.0 GW. - - TOTAL FIXTURE UNITS: 1.0 SAN. 28.0 GW 103.0 0 103. W.S.F.U. 103.0 FU = 70 GPM 2" METER AND WATER SERVICE ABLE E103.3(3) D.F.U. 109.0 FU = 4" PIPING HORIZONTAL A 1/4" PER FOOT SLOPE (216 FU MAX.) CONSULTANTS: JAMES H. ART, P.E. 305 2ND ST NW, SUITE 105 NEW BRIGHTON, MN 55112 PHONE: (651) 632 -2300 FAX: (651) 632-2397 . SEAL: 01111 111,jII16# 't�S C E M 9•�g�' No 63147 rl STATE OF C3 . <<l�t�eetN�A�� I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. I AM A DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE FLORIDA. .LAMES H. ART MAY 20, 2011 h° DATE ISSUED 63167 F :EG. N0. BLS _ BUFFALO WILD WINOS CONSTRUCTION DEPARTMENT 5500 WAYZATA BLVD., STE 1600 MINNEAPOLIS, MN 55413 PHONE (952) 593 -0943 FAX (952) 593 -9777 EDMOND FA ARAN THE SHOPS AT SUNSET PLACE 5701 SUNSET DRIVE; §1313A SOUTH MIAMI, FL',33143 FRANCHISEE: SETH DEKANTER EMAIL_ ssth4Nc8'i etmsl!.com y FRANCHISE .STOKE SHEET TITLE: PLUMBINS SCHEDULES ET ) WATER CALCULATIONS, (2006 IPC) APPENDIX 'E'm REVISioris: DOMESTIC WATER SERVICE = 2" WATER METER AND 2" BLDG. PIPING 102.0 WSFU = 70 GPM - ON FLUSH VALVE SYSTEM - TABLE El 03.3(3) CIO: DATE: .. i 70 GPM = 0.55 PSI LOSS - FOR DISK TYPE 2" TAP /METER - TABLE El 03.3(4) AVAIWLE PRESSURE APPROXIMATE - 6565 * PSI PRESS. LOSS ACROSS METER LOSS - 0.55 - -PSI STATIC PRESS. LOST (ELEV.) LOSS - 7.74 PSI (1i' -0" X 0.43) PROTECT NO: 1113:.001 GOVERNING FIXTURE - WATER CLOSET LOSS - 25 PSI BACKFLOW PREVENTER - (2" RPZ) LOSS - 10 ' PSI TOTAL PRESSURE AVAILABLE 21.71 PSI DISTANCE FROM METER TO LAST FIXTURE 415' 5770.11 TOTAL DEVELOPED LENGTH OF SYSTEM (X 1.25) 518' ALLOW. PRESS. 21.71 Y 100' 4.19 PSI LOSS /100 FT. 511' AVERAGE PRESS. DROP AVAILABLE FOR FRICTION 4.1'9 PSI FRICTION LOSS -LBS. PER SO. IN. HEAD PER 100 -FOOT LENGTH 4.0 PSI SMOOTH PIPE -- FIGURE E103.3(2) VELOCITY = 7.0 FPS t �r .,, *ny„ v V14 C iA , i REVISioris: �.... CIO: DATE: .. i BY. i I : I f' PROTECT NO: 1113:.001 DRAWN BY Mnl3 P400 5770.11 Em ml COPYRIGHT PATRICK G. BLEE:S, AIA 2011 t �r .,, *ny„ v V14 C iA , i