11-516-0420 y� N n 0 N IF 7 GENERAL NOTES 1. CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH MECHANICAL AND PLUMBING DRAWINGS AND SPECIFICATIONS. NEITHER THE DRAWINGS NOR THE SPECIFICATIONS SHALL BE COMPLETE WITHOUT THE OTHER. 2. PRIOR TO FINAL RID, THE PLUMBING CONTRACTOR SHALL VISIT THE SPACE AND FIELD VERIFY THE LOCATIONS OF ALL EXISTING PIPING TO REMAIN, UTILITY STUB -INS, ETC., FOR MECHANICAL AND PLUMBING SYSTEMS WITHIN THE SPACE. ALL TAP FEES, IMPACT FEES AND PUBLIC ASSESSMENT FEES SHALL BE INCLUDED IN THIS CONTRACTOR'S PRICE, 3. PLUMBING CONTRACTOR IS RESPONSIBLE FOR CONFORMANCE TO ALL LOCAL CODES AND HEALTH DEPARTMENT REGULATIONS. PROVIDE CLEARANCE FOR CLEANING BEHIND AND UNDER EXPOSED PIPING AS REQUIRED BY HEALTH DEPARTMENT. CONFORM TO HEALTH DEPARTMENT REQUIREMENTS FOR LOCATIONS OF FLOOR SINKS AND FLOOR DRAINS. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH BUILDING CODE, STATE AND /OR LOCAL HEALTH AUTHORITIES. 4. PLUMBING CONTRACTOR SHALL VERIFY ALL EQUIPMENT ROUGH -INS AND DETERMINE THE MOST FEASIBLE AND ECONOMICAL LOCATION TO INSTALL THE NEW WASTE LINES BELOW THE EXISTING SW, BASED ON CURRENT PLUMBING CONDITIONS. ROUGH -INS SHOWN ARE FOR EQUIPMENT ITEMS SUPPLIED BY KITCHEN EQUIPMENT VENDOR. ALL EQUIPMENT SUPPLIED BY OTHERS MUST BE VERIFIED BY THE RESPECTIVE TRADES, UNLESS OTHERWISE NOTED INDIVIDUALLY. PROVIDE SHUT -OFF VALVES TO EACH PLUMBING FIXTURE AND WHERE NOTED ON PLANS. FOR EQUIPMENT SCHEDULE, SEE DRAWING P400. FOR PLUMBING FIXTURE SCHEDULE, SEE DRAWING P400. 5. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE BASE BUILDING SYSTEMS. 6. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE BY THE ROOFING CONTRACTOR AT THE EXPENSE OF THE PLUMBING CONTRACTOR. 7. ALL DIMENSIONS ARE FROM FINISHED WALLS AND /OR COLUMN CENTERLINES. FLOOR DIMENSIONS: "AFF (ABOVE FINISHED FLOOR)- ARE TO THE CENTERLINE OF THE ROUGH -IN. S. ALL WATER LINES SHALL HAVE AN ACCESSIBLE SHUT OFF VALVE AT EACH CONNECTION POINT. 9. PLUMBING CONTRACTOR SHALL INSTALL NEW HAND SINKS, MOP SINKS, AND HOSE BIBBS WITH MIXING VALVES AND VACUUM BREAKERS. 10. ALL PLUMBING MATERIALS AND LABOR NECESSARY TO PERFORM COMPLETE CONNECTION OF EQUIPMENT WILL BE PROVIDED BY PLUMBING CONTRACTOR. 11. PLUMBING CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT ANY CONFLICTS TO THE ARCHITECT /ENGINEER PRIOR TO THE START OF WORK. 12. FOR ALL FIXTURES: HOT is COLD WATER CONNECTIONS ARE 1/2" UNLESS OTHERWISE NOTED. 13. ALL HOT AND COLD WATER PIPING TO BE INSULATED WITH FIBERGLASS INSULATION PER THE INTERNATIONAL ENERGY CONSERVATION CODE. COLD WATER PIPING TO HAVE CONTINUOUS VAPOR BARRIER. 14. CONTRACTOR TO FIELD VERIFY THAT GAS PRESSURE CAN BE DELIVERED TO SITE AT A MINIMUM OF 14 IN WC. GAS LINES SHALL HAVE AN ACCESSIBLE SHUT OFF VALVE AT EACH CONNECTION. 15. PLUMBING CONTRACTOR SHALL INSTALL ANSUL VALVE IN ACCESSIBLE LOCATION. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ALL LOCAL CODES. 16. ALL NEW /EXISTING NATURAL GAS PIPING TO BE SUPPORTED /RESUPPORTED WITH NEW POLY SUPPORTS. NATURAL GAS PIPING SHALL BE PRIMED AND PAINTED. 17. WATER LINES TO BE INSIDE OF WALLS, SURFACE MOUNTED WORK IS NOT ACCEPTABLE. 18. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL WATER HAMMER ARRESTORS IN LINE BEFORE ALL SOLENOID VALVES. I.E. AT DISHWASHER, DISPOSER(S), ICE MAKER(S), STEAMER(S), ETC. mmonj KEY NOTES O1 EXISTING FIRE SPRINKLER SYSTEM TO REMAIN. CONTRACTOR SHALL VERIFY ALL VALVES, HEADS AND ALARMS ARE IN GOOD CONDITION. REPAIR AND /OR REPLACE AS NEEDED. OEXISTING WATER METER TO REMAIN. CONTRACTOR SHALL VERIFY EXISTING WATER METER IS IN OPERABLE CONDITION. OPLUMBING CONTRACTOR SHALL TEST AND REUSE EXISTING REDUCED PRESSURE ■ACKFLOW (RPZ) BACKFLOW PREVENTER. IF NECESSARY, PLUMBING CONTRACTOR SHALL PROVIDE, PER CODE, RPZ BACKFLOW PREVENTER ON EXISTING DOMESTIC WATER SYSTEM. EXISTING WATER HEATERS TO REMAIN. VERIFY EXISTING WATER HEATERS ARE IN GOOD WORKING ORDER. CONTRACTOR SHALL REFURBISH AND /OR REPLACE BURNERS, IGNITORS, T&P VALVE. FLUSH AND SANITIZE UNITS IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. OPROVIDE BALANCING GLOBE VALVE AND CHECK VALVE AT TIE -IN POINT TO RECIRCULATING SYSTEM. OPROVIDE 1/4- HW(140') FOR CHEMICAL DISPENSER WITH 1/2" THREADED NIPPLE. SEE DETAIL 2/P201. INSTALL VALVES ON HORIZONTAL PIPING ABOVE CEILING. COORDINATE LOCATION WITH OWNER AND ALL OTHER TRADES PRIOR TO INSTALLATION. INSTALL MIXING VALVE ABOVE THE CEILING. OPROVIDE 1/2- HW(140') is 1 /2 -CW TO GLASS WASHER. OPROVIDE CHECK VALVE AND SHUT -OFF VALVE AT TIE -IN POINT TO RECALCULATING SYSTEM. VALVES SHALL BE ACCESSIBLE FROM BAR SIDE. 10 CONTRACTOR SHALL VERIFY EXACT LOCATION, PRESSURE AND SIZE OF EXISTING SERVICE AND METER WITH UTILITY PRIOR TO BEGINNING WORK. GAS DISTRIBUTION SIZING IS BASED ON 7" W.C. ON OUTLET SIDE OF METER. SEE SHEET P301 FOR GAS PIPING SCHEMATIC AND GAS PIPE SIZES. 11 LOCATE 2 -1/2" AUTOMATIC GAS SHUTOFF SOLENOID VALVE BELOW KITCHEN CEILING, AT ACCESSIBLE LOCATION. VERIFY REQUIREMENTS WITH LOCAL AUTHORITIES. VERIFY LOCATION WITH OWNER PRIOR TO INSTALLATION. <12 > CONTRACTOR SHALL REPLACE EXISTING GAS PIPING DOWNSTREAM OF SOLENOID VALVE. SEE GAS PIPING DETAIL 24/P202. I_ 13 VERIFY EXISTING WALL HYDRANT IS IN OPERABLE CONDITION. IF IN NEED OF REPLACEMENT, PROVIDE A NEW FREEZE -PROOF WALL HYDRANT (WH) WITH WALL BOX. USE WOODFORD - MODEL #67C, FIELD TESTABLE 3/4- NON- FREEZE LOOSE KEY. LOCATE SHUT -OFF VALVE INSIDE BUILDING. 14 PROVIDE TRAP PRIMING FOR NEW FLOOR DRAINS /SINKS. SEE RISER DIAGRAM ON SHEET P200 AND SEE SHEET P100 FOR TRAP PRIMER LINES. PROVIDE 1202 PLASTIC ACCESS PANEL FOR TRAP PRIMER ACCESS AND MAINTENANCE. 15 PROVIDE 1" COLD WATER LINE TO SODA SYSTEM WATER FILTERS. FILTERS BY OTHERS. WATER SUPPLY TO CARBONATORS PROVIDED THRU A STAINLESS STEEL RPZ VALVE ON WATER FILTER SYSTEM. SEE WATER FILTER SCHEMATIC ON SHEET P201. 1 C MIXING VALVE: PROVIDE VALVE WHERE INDICATED. SEE SCHEDULE ON SHEET MO.0. INSTALL MIXING VALVE BELOW FIXTURE IN CABINET OR ABOVE CEILING WHERE APPLICABLE IN AN ACCESSIBLE LOCATION. COORDINATE MOUNTING LOCATION WITH CONSTRUCTION MANAGER PRIOR TO INSTALLATION. MIXING VALVE SHALL BE PROVIDED WITH DIAL TYPE THERMOMETER ON DISCHARGE PIPING. SET DISCHARGE PIPING TEMPERATURE TO 110'F. 17 RELOCATE EXISTING HAND SINK AND FAUCET. VERIFY IN GOOD CONDITION. REPAIR AS NEEDED. <a> RELOCATE, REFURBISH TO 'LIKE -NEW' CONDITION AND REINSTALL EXISTING DISHWASHER IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. SANITIZE UNIT IN ACCORDANCE WITH LOCAL CODES. <9> EXISTING RESTROOM FIXTURES TO REMAIN. CONTRACTOR SHALL VERIFY IN GOOD CONDITION. <20 > EXISTING MOPSINK BASIN TO REMAIN. REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL INFORMATION. VERIFY FAUCET AND DRAIN IN GOOD OPERATING CONDITION. 21 > EXISTING KITCHEN FIXTURES /EQUIPMENT TO REMAIN. CONTRACTOR SHALL VERIFY FAUCETS, WATER AND WASTE PIPING TO EACH ARE IN GOOD CONDITION. SANITIZE IN ACCORDANCE WITH LOCAL REQUIREMENTS. QCONTRACTOR SHALL PROVIDE NEW 3/4" HOT WATER RECIRCULATION LINE WHERE SHOWN ON PLAN OR ROUTE AS NECESSARY IF OBSTRUCTIONS EXIST. <23> REFURBISH AND SANITIZE EXISTING WATER SOFTENERS IN ACCORDANCE WITH vV MANUFACTURER'S REQUIREMENTS AND IN ACCORDANCE WITH LOCAL CODES. GREASE REMOVAL SYSTEM: PROVIDE MAHONEY JMEC- 50 -IDC DIRECT PUMP SYSTEM. SYSTEM INCLUDES STORAGE TANK, EXTRACTION WAND WITH HOSE, AND PUMP. PROVIDE PIPING FROM GREASE COLLECTION TANK TO EXTRACTION WAND AT FRYERS AS RECOMENDED BY MANUFACTURER. COORDINATE INSTALLATION OF 2- GREASE DISCHARGE PIPING TO OUTSIDE WITH ARCHITECT AND LANDLORD PRIOR TO BEGINNING WORK. VERIFY INSTALLATION REQUIREMENTS WITH MANUFACTURER PRIOR TO PERFORMING WORK. EXISTING DOMESTIC CW SYMBOL LIST ABBREVIATIONS FD FLOOR DRAIN FS FLOOR SINK FCO FLOOR CLEAN -OUT WCO WALL CLEAN -OUT VTR VENT THROUGH ROOF IND. W. INDIRECT WASTE WH WALL HYDRANT PIPE SIZES SHOWN ON SHEET P301 REFER TO P400 FOR PLUMBING FIXTURE AND MECHANICAL EQUIPMENT SCHEDULE PATIO 127 RECIRC - - —� 140' S' ncs �nn �T MV -1 1 fr CW VF ALCOVI TO 118 1 El FIRE PROTECTION GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTING WITH A CERTIFIED FIRE PROTECTION SPECIALIST. FIRE PROTECTION SPECIALIST SHALL PROVIDE, FOR APPROVAL, CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO THE GOVERNING AUTHORITIES HAVING JURISDICTION. THE DOCUMENTS SHALL INCLUDE BUT NOT BE LIMITED TO THE INSTALLATION OF A NEW FIRE PROTECTION SYSTEM AND /OR THE ADJUSTMENT OF AN EXISTING SPRINKLER SYSTEM. ALL FIRE PROTECTION SYSTEMS SHALL BE COORDINATED WITH ALL OTHER TRADES AND ARCHITECTURAL CHARACTERISTICS OF THE PROJECT. rr V 13 3/4" 1 I C- 13 WH I i� EXISTING GAS METER •• V V LEGEND — —W— — SANITARY WASTE • RWL RAINWATER LEADER v U 'y3" 9'1 „ 1 UNDERGROUND GW GREASE WASTE RAINWATER LEADER • V '�'' Ss. 1fN BLEES V — —V— — VENT aG GAS METER PATRICK G. RLEES. ARCHITECT SCHEDULE 40 2.19 N� 2ND S%, 1UITE 301 — PVC PIPING O WATER METER CW COLD WATER pp TIE INTO EXISTING E —MAIL: Info*cma rch.com PIPING (CW) v HW HOT WATER PIPING BALANCING GLOBE VALVE 110'F (HW) NEW BRIGHTON, MN 551.12 PHONE: (651) 632 --2300 GATE VALVE HOT WATER PIPING 1G0'MW 160-F (160'HW) c3] RECALCULATING PUMP HOT WATER PIPING RHW RECIRC (HWR) F! REDUCED PRESSURE BACKFI OW PREVENTER G GAS MIXING VALVE FLOOR SINK CD CONDENSATE LINE d FLOOR DRAIN — — TP — — TRAP PRIMER LINE E, BALL VALVE 13 WH I i� EXISTING GAS METER •• V V r3 •u••Y Y•E' .Vj]'� T� .' f� V V4• V • • ••• V V v U 'y3" 9'1 „ 1 PATRICK • V '�'' Ss. 1fN BLEES V V Vim: PATRICK G. RLEES. ARCHITECT G•..• 2.19 N� 2ND S%, 1UITE 301 • '-wrW °55401 v • • u �14!NNEA°G`LIS, PHONE: (612 ) 338 --6677 FAX: (612) 338 --2995 E —MAIL: Info*cma rch.com CONSULTANTS: JAMES H. ART, P.E. 305 2ND ST NW, SUITE' 105 NEW BRIGHTON, MN 551.12 PHONE: (651) 632 --2300 FAX: (651) 632 -2397 rl_" WATER AND GAS PLAN �OOSCALE: 1/4' -1' -0" 0 4' B' 16 1 N cm 111==31 SCALE BASED ON A 30 "x42" SHEET SIZE SEAL: •r e ~,` ,v No 631 •. ,. A ; STATE OF . w I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. I AM A DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE FLORIDA. JAMES H. ART MAY 20, 2011 DATE ISSUED _.. _.. __..._ 63167 PEG. NO. BUFFALO WILD WINGS COPJSTRUCTION DEPARTMENT 5500 WAYZATA BLVD., ' STE 1500 MINNEAPOLIS, MN 55416 PHONE (952) 5993 -1943 FAX (152) 593 -9137 EDMOND FARRAN THE SHOPS AT SUNSET PLACE 5701 SUNSET DRIVE; #913A SOUTH MIAMI, FL' 33143 f FRANCHISEE: SF-TH DEKANTER EMAIL:- ssthdskChstms1c*m FRANCHISE STORE SHEET TITLE: WATER AND GAS DISTRIBUTION PLAN, PERMIT 'SET REVISIONS: NO: DALE: BY: I r - ........_ .._ .......... .......... .. .. I r � I -- ---- - - - - -- is PROJECT N0: 11136.001 DRAWN BY: Mill P200 5770.11 COPYRIGHT PATRICK G. BLEB S, AIA 2011