GENERAL NOTES
1. CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH MECHANICAL AND PLUMBING DRAWINGS AND SPECIFICATIONS.
NEITHER THE DRAWINGS NOR THE SPECIFICATIONS SHALL BE COMPLETE WITHOUT THE OTHER.
2. PRIOR TO FINAL RID, THE PLUMBING CONTRACTOR SHALL VISIT THE SPACE AND FIELD VERIFY THE LOCATIONS OF
ALL EXISTING PIPING TO REMAIN, UTILITY STUB -INS, ETC., FOR MECHANICAL AND PLUMBING SYSTEMS WITHIN THE
SPACE. ALL TAP FEES, IMPACT FEES AND PUBLIC ASSESSMENT FEES SHALL BE INCLUDED IN THIS CONTRACTOR'S
PRICE,
3. PLUMBING CONTRACTOR IS RESPONSIBLE FOR CONFORMANCE TO ALL LOCAL CODES AND HEALTH DEPARTMENT
REGULATIONS. PROVIDE CLEARANCE FOR CLEANING BEHIND AND UNDER EXPOSED PIPING AS REQUIRED BY HEALTH
DEPARTMENT. CONFORM TO HEALTH DEPARTMENT REQUIREMENTS FOR LOCATIONS OF FLOOR SINKS AND FLOOR
DRAINS. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH BUILDING CODE, STATE AND /OR LOCAL HEALTH
AUTHORITIES.
4. PLUMBING CONTRACTOR SHALL VERIFY ALL EQUIPMENT ROUGH -INS AND DETERMINE THE MOST FEASIBLE AND
ECONOMICAL LOCATION TO INSTALL THE NEW WASTE LINES BELOW THE EXISTING SW, BASED ON CURRENT
PLUMBING CONDITIONS. ROUGH -INS SHOWN ARE FOR EQUIPMENT ITEMS SUPPLIED BY KITCHEN EQUIPMENT VENDOR.
ALL EQUIPMENT SUPPLIED BY OTHERS MUST BE VERIFIED BY THE RESPECTIVE TRADES, UNLESS OTHERWISE NOTED
INDIVIDUALLY. PROVIDE SHUT -OFF VALVES TO EACH PLUMBING FIXTURE AND WHERE NOTED ON PLANS. FOR
EQUIPMENT SCHEDULE, SEE DRAWING P400. FOR PLUMBING FIXTURE SCHEDULE, SEE DRAWING P400.
5. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE BASE BUILDING SYSTEMS.
6. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE BY THE ROOFING CONTRACTOR AT THE EXPENSE OF
THE PLUMBING CONTRACTOR.
7. ALL DIMENSIONS ARE FROM FINISHED WALLS AND /OR COLUMN CENTERLINES. FLOOR DIMENSIONS: "AFF (ABOVE
FINISHED FLOOR)- ARE TO THE CENTERLINE OF THE ROUGH -IN.
S. ALL WATER LINES SHALL HAVE AN ACCESSIBLE SHUT OFF VALVE AT EACH CONNECTION POINT.
9. PLUMBING CONTRACTOR SHALL INSTALL NEW HAND SINKS, MOP SINKS, AND HOSE BIBBS WITH MIXING VALVES AND
VACUUM BREAKERS.
10. ALL PLUMBING MATERIALS AND LABOR NECESSARY TO PERFORM COMPLETE CONNECTION OF EQUIPMENT WILL BE
PROVIDED BY PLUMBING CONTRACTOR.
11. PLUMBING CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT ANY CONFLICTS TO THE
ARCHITECT /ENGINEER PRIOR TO THE START OF WORK.
12. FOR ALL FIXTURES: HOT is COLD WATER CONNECTIONS ARE 1/2" UNLESS OTHERWISE NOTED.
13. ALL HOT AND COLD WATER PIPING TO BE INSULATED WITH FIBERGLASS INSULATION PER THE INTERNATIONAL ENERGY
CONSERVATION CODE. COLD WATER PIPING TO HAVE CONTINUOUS VAPOR BARRIER.
14. CONTRACTOR TO FIELD VERIFY THAT GAS PRESSURE CAN BE DELIVERED TO SITE AT A MINIMUM OF 14 IN WC. GAS
LINES SHALL HAVE AN ACCESSIBLE SHUT OFF VALVE AT EACH CONNECTION.
15. PLUMBING CONTRACTOR SHALL INSTALL ANSUL VALVE IN ACCESSIBLE LOCATION. INSTALLATION SHALL BE IN
ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ALL LOCAL CODES.
16. ALL NEW /EXISTING NATURAL GAS PIPING TO BE SUPPORTED /RESUPPORTED WITH NEW POLY SUPPORTS. NATURAL
GAS PIPING SHALL BE PRIMED AND PAINTED.
17. WATER LINES TO BE INSIDE OF WALLS, SURFACE MOUNTED WORK IS NOT ACCEPTABLE.
18. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL WATER HAMMER ARRESTORS IN LINE BEFORE ALL SOLENOID
VALVES. I.E. AT DISHWASHER, DISPOSER(S), ICE MAKER(S), STEAMER(S), ETC.
mmonj
KEY NOTES
O1 EXISTING FIRE SPRINKLER SYSTEM TO REMAIN. CONTRACTOR SHALL VERIFY ALL VALVES,
HEADS AND ALARMS ARE IN GOOD CONDITION. REPAIR AND /OR REPLACE AS NEEDED.
OEXISTING WATER METER TO REMAIN. CONTRACTOR SHALL VERIFY EXISTING WATER METER IS
IN OPERABLE CONDITION.
OPLUMBING CONTRACTOR SHALL TEST AND REUSE EXISTING REDUCED PRESSURE ■ACKFLOW
(RPZ) BACKFLOW PREVENTER. IF NECESSARY, PLUMBING CONTRACTOR SHALL PROVIDE, PER
CODE, RPZ BACKFLOW PREVENTER ON EXISTING DOMESTIC WATER SYSTEM.
EXISTING WATER HEATERS TO REMAIN. VERIFY EXISTING WATER HEATERS ARE IN GOOD
WORKING ORDER. CONTRACTOR SHALL REFURBISH AND /OR REPLACE BURNERS, IGNITORS,
T&P VALVE. FLUSH AND SANITIZE UNITS IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS.
OPROVIDE BALANCING GLOBE VALVE AND CHECK VALVE AT TIE -IN POINT TO RECIRCULATING
SYSTEM.
OPROVIDE 1/4- HW(140') FOR CHEMICAL DISPENSER WITH 1/2" THREADED NIPPLE. SEE DETAIL
2/P201.
INSTALL VALVES ON HORIZONTAL PIPING ABOVE CEILING. COORDINATE LOCATION WITH OWNER
AND ALL OTHER TRADES PRIOR TO INSTALLATION. INSTALL MIXING VALVE ABOVE THE
CEILING.
OPROVIDE 1/2- HW(140') is 1 /2 -CW TO GLASS WASHER.
OPROVIDE CHECK VALVE AND SHUT -OFF VALVE AT TIE -IN POINT TO RECALCULATING SYSTEM.
VALVES SHALL BE ACCESSIBLE FROM BAR SIDE.
10 CONTRACTOR SHALL VERIFY EXACT LOCATION, PRESSURE AND SIZE OF EXISTING SERVICE
AND METER WITH UTILITY PRIOR TO BEGINNING WORK. GAS DISTRIBUTION SIZING IS BASED
ON 7" W.C. ON OUTLET SIDE OF METER. SEE SHEET P301 FOR GAS PIPING SCHEMATIC
AND GAS PIPE SIZES.
11 LOCATE 2 -1/2" AUTOMATIC GAS SHUTOFF SOLENOID VALVE BELOW KITCHEN CEILING, AT
ACCESSIBLE LOCATION. VERIFY REQUIREMENTS WITH LOCAL AUTHORITIES. VERIFY LOCATION
WITH OWNER PRIOR TO INSTALLATION.
<12 > CONTRACTOR SHALL REPLACE EXISTING GAS PIPING DOWNSTREAM OF SOLENOID VALVE. SEE
GAS PIPING DETAIL 24/P202. I_
13 VERIFY EXISTING WALL HYDRANT IS IN OPERABLE CONDITION. IF IN NEED OF REPLACEMENT,
PROVIDE A NEW FREEZE -PROOF WALL HYDRANT (WH) WITH WALL BOX. USE WOODFORD -
MODEL #67C, FIELD TESTABLE 3/4- NON- FREEZE LOOSE KEY. LOCATE SHUT -OFF VALVE
INSIDE BUILDING.
14 PROVIDE TRAP PRIMING FOR NEW FLOOR DRAINS /SINKS. SEE RISER DIAGRAM ON SHEET
P200 AND SEE SHEET P100 FOR TRAP PRIMER LINES. PROVIDE 1202 PLASTIC ACCESS
PANEL FOR TRAP PRIMER ACCESS AND MAINTENANCE.
15 PROVIDE 1" COLD WATER LINE TO SODA SYSTEM WATER FILTERS. FILTERS BY OTHERS.
WATER SUPPLY TO CARBONATORS PROVIDED THRU A STAINLESS STEEL RPZ VALVE ON WATER
FILTER SYSTEM. SEE WATER FILTER SCHEMATIC ON SHEET P201.
1 C MIXING VALVE: PROVIDE VALVE WHERE INDICATED. SEE SCHEDULE ON SHEET MO.0. INSTALL
MIXING VALVE BELOW FIXTURE IN CABINET OR ABOVE CEILING WHERE APPLICABLE IN AN
ACCESSIBLE LOCATION. COORDINATE MOUNTING LOCATION WITH CONSTRUCTION MANAGER
PRIOR TO INSTALLATION. MIXING VALVE SHALL BE PROVIDED WITH DIAL TYPE THERMOMETER
ON DISCHARGE PIPING. SET DISCHARGE PIPING TEMPERATURE TO 110'F.
17 RELOCATE EXISTING HAND SINK AND FAUCET. VERIFY IN GOOD CONDITION. REPAIR AS
NEEDED.
<a> RELOCATE, REFURBISH TO 'LIKE -NEW' CONDITION AND REINSTALL EXISTING DISHWASHER IN
ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. SANITIZE UNIT IN
ACCORDANCE WITH LOCAL CODES.
<9> EXISTING RESTROOM FIXTURES TO REMAIN. CONTRACTOR SHALL VERIFY IN GOOD CONDITION.
<20 > EXISTING MOPSINK BASIN TO REMAIN. REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL
INFORMATION. VERIFY FAUCET AND DRAIN IN GOOD OPERATING CONDITION.
21 > EXISTING KITCHEN FIXTURES /EQUIPMENT TO REMAIN. CONTRACTOR SHALL VERIFY FAUCETS,
WATER AND WASTE PIPING TO EACH ARE IN GOOD CONDITION. SANITIZE IN ACCORDANCE
WITH LOCAL REQUIREMENTS.
QCONTRACTOR SHALL PROVIDE NEW 3/4" HOT WATER RECIRCULATION LINE WHERE SHOWN ON
PLAN OR ROUTE AS NECESSARY IF OBSTRUCTIONS EXIST.
<23> REFURBISH AND SANITIZE EXISTING WATER SOFTENERS IN ACCORDANCE WITH
vV MANUFACTURER'S REQUIREMENTS AND IN ACCORDANCE WITH LOCAL CODES.
GREASE REMOVAL SYSTEM: PROVIDE MAHONEY JMEC- 50 -IDC DIRECT PUMP SYSTEM. SYSTEM INCLUDES
STORAGE TANK, EXTRACTION WAND WITH HOSE, AND PUMP. PROVIDE PIPING FROM GREASE COLLECTION
TANK TO EXTRACTION WAND AT FRYERS AS RECOMENDED BY MANUFACTURER. COORDINATE INSTALLATION OF
2- GREASE DISCHARGE PIPING TO OUTSIDE WITH ARCHITECT AND LANDLORD PRIOR TO BEGINNING WORK.
VERIFY INSTALLATION REQUIREMENTS WITH MANUFACTURER PRIOR TO PERFORMING WORK.
EXISTING
DOMESTIC
CW
SYMBOL LIST
ABBREVIATIONS
FD FLOOR DRAIN
FS FLOOR SINK
FCO FLOOR CLEAN -OUT
WCO WALL CLEAN -OUT
VTR VENT THROUGH ROOF
IND. W. INDIRECT WASTE
WH WALL HYDRANT
PIPE SIZES
SHOWN ON
SHEET P301
REFER TO P400
FOR PLUMBING
FIXTURE AND
MECHANICAL
EQUIPMENT
SCHEDULE
PATIO
127
RECIRC -
- —� 140'
S' ncs �nn
�T
MV -1
1 fr CW
VF
ALCOVI TO
118 1 El
FIRE PROTECTION
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
CONTRACTING WITH A CERTIFIED FIRE PROTECTION SPECIALIST.
FIRE PROTECTION SPECIALIST SHALL PROVIDE, FOR APPROVAL,
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO THE
GOVERNING AUTHORITIES HAVING JURISDICTION. THE DOCUMENTS
SHALL INCLUDE BUT NOT BE LIMITED TO THE INSTALLATION OF
A NEW FIRE PROTECTION SYSTEM AND /OR THE ADJUSTMENT OF
AN EXISTING SPRINKLER SYSTEM. ALL FIRE PROTECTION
SYSTEMS SHALL BE COORDINATED WITH ALL OTHER TRADES
AND ARCHITECTURAL CHARACTERISTICS OF THE PROJECT.
rr V
13
3/4"
1 I
C-
13
WH
I
i�
EXISTING
GAS METER
•• V V
LEGEND
— —W—
— SANITARY WASTE
•
RWL RAINWATER LEADER
v U
'y3" 9'1 „ 1
UNDERGROUND
GW
GREASE WASTE
RAINWATER LEADER
• V
'�'' Ss. 1fN
BLEES
V
— —V—
— VENT
aG
GAS METER
PATRICK G. RLEES. ARCHITECT
SCHEDULE 40
2.19 N� 2ND S%, 1UITE 301
—
PVC PIPING
O
WATER METER
CW
COLD WATER
pp
TIE INTO EXISTING
E —MAIL: Info*cma rch.com
PIPING (CW)
v
HW
HOT WATER PIPING
BALANCING GLOBE VALVE
110'F (HW)
NEW BRIGHTON, MN 551.12
PHONE: (651) 632 --2300
GATE VALVE
HOT WATER PIPING
1G0'MW
160-F (160'HW)
c3]
RECALCULATING PUMP
HOT WATER PIPING
RHW
RECIRC (HWR)
F!
REDUCED PRESSURE BACKFI OW PREVENTER
G
GAS
MIXING VALVE
FLOOR SINK
CD
CONDENSATE LINE
d
FLOOR DRAIN
— — TP —
— TRAP PRIMER LINE
E,
BALL VALVE
13
WH
I
i�
EXISTING
GAS METER
•• V V
r3 •u••Y Y•E'
.Vj]'� T� .' f� V V4• V
•
•
••• V V
v U
'y3" 9'1 „ 1
PATRICK
• V
'�'' Ss. 1fN
BLEES
V
V Vim:
PATRICK G. RLEES. ARCHITECT
G•..•
2.19 N� 2ND S%, 1UITE 301
•
'-wrW °55401
v • • u �14!NNEA°G`LIS,
PHONE: (612 ) 338 --6677
FAX: (612) 338 --2995
E —MAIL: Info*cma rch.com
CONSULTANTS:
JAMES H. ART, P.E.
305 2ND ST NW, SUITE' 105
NEW BRIGHTON, MN 551.12
PHONE: (651) 632 --2300
FAX: (651) 632 -2397
rl_" WATER AND GAS PLAN
�OOSCALE: 1/4' -1' -0"
0 4' B' 16 1 N
cm 111==31
SCALE BASED ON A 30 "x42" SHEET SIZE
SEAL:
•r
e ~,` ,v
No 631 •.
,.
A ; STATE OF . w
I HEREBY CERTIFY THAT THE
PORTION OF THIS TECHNICAL
SUBMISSION DESCRIBED BELOW
WAS PREPARED BY ME OR UNDER
MY DIRECT SUPERVISION AND
RESPONSIBLE CHARGE. I AM A
DULY REGISTERED ENGINEER UNDER
THE LAWS OF THE STATE FLORIDA.
JAMES H. ART
MAY 20, 2011
DATE ISSUED
_.. _.. __..._ 63167
PEG. NO.
BUFFALO WILD WINGS
COPJSTRUCTION DEPARTMENT
5500 WAYZATA BLVD., ' STE 1500
MINNEAPOLIS, MN 55416
PHONE (952) 5993 -1943 FAX (152) 593 -9137
EDMOND FARRAN
THE SHOPS AT SUNSET PLACE
5701 SUNSET DRIVE; #913A
SOUTH MIAMI, FL' 33143
f
FRANCHISEE:
SF-TH DEKANTER
EMAIL:- ssthdskChstms1c*m
FRANCHISE STORE
SHEET TITLE:
WATER AND GAS
DISTRIBUTION PLAN,
PERMIT 'SET
REVISIONS:
NO: DALE: BY:
I
r
- ........_ .._ .......... .......... .. .. I
r �
I
-- ---- - - - - --
is
PROJECT N0: 11136.001
DRAWN BY: Mill
P200
5770.11
COPYRIGHT PATRICK G. BLEB S, AIA 2011