11-516-0410 cV DETAIL NOT USED r15 SCALE: NONE P101 WALL/EQUIVALENT STRUCTURE FASTEN 3 -5/16" X 1 -3/8" CEILING WASTE PIPE TO FLANGE TO WALL STRUCTURE G" AFF SINK /FIXTURE ABOVE 3/8" MINIMUM � PIPE CLAMP THREADED ROD NOTE: TRIANGULATE BRACING WASTE PIPE DETAIL NOT USED 1� TO FLOOR SINK SCALE: NONE P101 BELOW UNDER DL— 1 AIL PIPES SUP ORT 17 SCALE: NONE P101 NOTES: 1. PROVIDE CLEANOUT IN TURNS AND ENDS OF DRAIN PIPING 2. INSTALL PIPE AS HIGH AS POSSIBLE, ANCHORED TO WALL OF COOLER WITH SUPPORTS AS MAX OF G' CENTERS. USE TYPE M HARD COPPER TUBE AND FITTINGS WITH LEAD -FREE SOLDER JOINTS. PROVIDE CHROMATONE PAINT ON PIPE EXTERIOR OF COOLER. CONDENSER AND DRAIN PAN LOCATED INSIDE OF COOLER /FREEZER. CONDENSATE DRAIN LINE SLOPED AT 1/4" PER 1' -0" HEAT CABLE SHALL BE - FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. PLUMBING CONTRACTOR SHALL FURNISH \�\ AND INSTALL 1" INSULATION OVER HEAT CABLE AND CONDENSATE PIPE IN FREEZER ONLY DRILL HOLE IN SIDE OF COOLER. PROVIDE GROMMET OR SLEEVE WITH SILICONE SEAL TO MAKE WATER TIGHT PROVIDE TRAP AT BOTTOM OF OF RISER FLAT ®� FLOOR SINK AGAINST WALL. DISCHARGE WITH AIR GAP MIN OF TWICE PIPE DIAMETER. DETAICONDENSATE L LINE DETAIL DRAIN 1i SCALE: NONE P101 CD :2 04 0 t2 N 7 7 TRENCH DRAIN #3 • 12' --0" OC SEE STRUCTURAL 8" VERIFY WIl MANUFACTURE SLOPE TO TRENCH DRAIN 1/4" /FOOT INVERT DETAIL TYPICAL TRENCH DRAIN 19 SCALE: NONE P101 DETAIL NOT USED 11 SCALE: NONE P101 THREADED FLUSH CLE SCHED. 40 2" CLEANOI TEE FITTING FINISHED WALL SURFACE ACCESS COVER AND FRAME CLEANOUT WITH ACCESS COVER INSTALLED IN A STANDARD 3%" METAL STUD WALL DETAIL WALL CLEANOUT rl 2 SCALE: NONE P101 PACK ANNULAR SPACE SLEEVE FLUSH IF WALL IS GYPSUM BETWEEN SLEEVE AND WITH WALL WALLBOARD, PROVIDE PIPE SOLID WITH GALVANIZED STEEL PIPE OR FIBERGLASS INSULATION MINIMUM 19 GA GALVANIZED (FOR ACOUSTICS) SHEET METAL SLEEVE. CAULK t PATRICK G. ILEES„ ARCHITECT y y �` yl 219 N: 2ND ST., SUITE 301 .,lfNREA9- OR GROUT SLEEVE IN PLACE .�." PHONE: (612) 33E -6677 AS REQUIRED. CENTER PIPE (AND E—MAIL: Info*cmorch.com INSULATION) IN SLEEVE. JAMES H. ART, P.t. INSULATION CONTINUES NEW BRIGHTON, MN 55112 PIPE OR CONDUIT THRU SLEEVE: DO NOT __ __ _____ _____________ --------------- - - - - -- FAX: (651) 632 -2397 . BUTT AGAINST WALL t UNINSULATED PIPE INSULATED PIPE IF WALL IS PRECAST CONCRETE CORE DRILL ______ AND OMIT SLEEVE. __=== = = = - -_ __________- IF WALL IS MASONRY '. UNIT CONSTRUCTION ''• OR POURED CONCEALED PIPE WILL '" ' ' CONCRETE, PROVIDE NOT HAVE ESCUTCHEON %EXPOSED GALVANIZED STEEL TO COVER PENETRATION PIPE SLEEVE GROUTED INTO WALL PIPE SHALL HAVE ESCUTCHEON TO COVER REFER TO ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. PENETRATION. REFER TO SPECIFICATIONS FOR ALTERNATIVE INSTALLATIONS. DETAIL PENETRATION THROUGH NON FIREWALL r7_� SCALE: NONE P101 DETAIL NOT USED 14 SCALE NONE P101 CONDENSATE DRAIN PIPING IN WALL FRAMII OR EXPOSED SPILL CONDENSATE DRAIN PIPING OVER FLOOR DRAIN 2" AIR GAP ---- L PROVIDE P —TRAP WHEN REQUIRED. FLOOR FUNNEL DRAIN TURN ELBOW OUT OVER DRAIN DE1 AIL CONDENSATE TERMINATION 7 SCALE: NONE P101 PROVIDE ONE PIECE SPUN ALUMINUM BASE WITH, GRADULATED STEPPED PVC BOOT, AND ADJUSTABLE STAINLESS STEEL CLAMPS. SET SASE IN BED OF MASTIC REFER TO ARCHITECTS DRAWING FOR APPLICATION MINIMUM 12" ABOVE ROOF OF VENT PIPE BOOT INSTALLATION WITH ROOFING MATERIAL ROOF INSULATION II II III III ROOF DECK 111 111 PROVIDE SLEEVE IF lam-- ANCHOR PIPE TO ROOF REQUIRED BY TYPE DECK OR JOISTS WITH OF ROOF DECK U -BOLT AROUND PIPE MINIMUM 12" BELOW ROOF AND ANGLE IRON OR SCREWED TO DECK OR JOIST REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MINIMUM TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE. PROVIDE 1" FIBERGLASS INSULATION WITH ALL- SERVICE JACKET ON VENT PIPE INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY FLASHING AND CONTERFLASHING WITH ROOFING CONTRACTOR. DE TAIL VENT PENETRATION i SCALE: NONE P101 CLEANOUTS IN ENDS OF PIPE FLOOR 12.2 � 2" 4" MAINTAIN AIR GAP TWICE PIPE DIAMETER FLOOR SINK ROUTE COMBINED SANITARY DRAIN LINE TO WALL. ROUTE VENT UP, AND SANITARY DOWN AS SHOWN ON PUNS. ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. DWV COPPER PIPE, FITTINGS AND CONNECTORS ALL AROUND SINK. DETAILSCULLERY SINK DRAIN SCALE: NONE P101 ANCHOR -- PER NFPA NOTE: BUILDING STRUCTURE MAY VARY MATCH INSTALLATION TO BUILDING STRUCTURE REFER TO STRUCTURAL DRAWINGS FOR ATTACHMENT. 3/8" ALL- THREAD ROD FOR < =4" PIPE. FOR LARGER PIPE SIZES SEE NFPA 13. HANGER - GRINNEL FIG. 69 --° ON INSULATED PIPE. PROVIDE PIPE SUPPORT SHIELD. DETAILPIPE HANGER 10 SCALE. NONE P101 D` 1 AIL NOT USED 1 SCALE: NONE Plpl FINISHED FLOORS CLEAN -OUT JATION WYE /8 BEND DETAILCLEAN-OUT r2 SCALE: NONE P101 FLOOR DRAIN 36" SQ. STRAINER FLUSH MIN. WITH FINISH FLOOR FIN. FLOOR—,,,,, SLOPE TO FLOOR DRAIN 1/4" CLAMP PAN INTO DRAIN ROUGH FLOOR SLAB \ / DEEP SEAL �✓ P —TRAP DETAILTYPICAL FLOOR DRAIN 3 SCALE. NONE p101 FINISHED SHORT SWEEP DETAIL END OF RUN 4 SCALE NONE P101 8" SODA POP LINE PIPE CAP CONCRETE FLOOR 3" MINIMUM WITH CAP LONG RADIUS 90' ELECTRICAL SWEEP ELBOW. —�—� DETAIL I" ITH CAP LINE 5 SCALE NONE P101 FLOOR SINKS SHALL BE 36" SO. MIN. INSTALLED WITH SINK TIGHT TO FININSHED FIN. FLOOR 12 x12" OOR CLAMP PAN TIGHTLY ; INTO DRAIN FLANGE ROUGH FLOOR SLAB FLANGE DOME STRAINER DEEP SEAL P -TRAP DETAIL TYPICAL FLOOR SINK i SCALE: NONE P101 SEAL: t��t�tl�tittilrrr��� � , •Iw • No 1431 r ^' w w • � STATE OF +I[►� I HERESY CERTIFY THAT THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW' WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. I AM A DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE FLORIDA. JAMES H. ART DATE - MAY 0, 2011 DATE ISSUED 63167 BEG. N0. BUFFALO WILD VINGS CONSTRUCTION DEPARTMENT 5500 WAYZATA BLVD., STE 1600 MINNEAPOLIS, MN 55416 PHONE (952) 59 --"43 FAX (552) 593 -9757 EDMOND FARRAN THE SHOPS AT SUNSET PACE 5701 SUNSET DRIVE, 113 13A SOUTH MIAMI, FL 33143 FRANr>iISEE SETH DEKANTER EMAIL- sathidakC hetmatl.csm FRANCHISE STORE SHEET TIT LE: i�lASTE do VENT DETAILS PERMIT ET REVISIONS: NO: DATE: BY- PROJECT NO: fi . r•rr" rr• DRAWN BY: c, • 4 a F u � • u, PATRICK C BLESS k t PATRICK G. ILEES„ ARCHITECT y y �` yl 219 N: 2ND ST., SUITE 301 .,lfNREA9- 0LI.S,'Wt4 ° N55401 .�." PHONE: (612) 33E -6677 FAX: (6122) 338 -2993 E—MAIL: Info*cmorch.com CONSULTANTS: JAMES H. ART, P.t. 305 2ND ST NW, SUITE 105 NEW BRIGHTON, MN 55112 PHONE: (651) 6932 -2300 FAX: (651) 632 -2397 . t SEAL: t��t�tl�tittilrrr��� � , •Iw • No 1431 r ^' w w • � STATE OF +I[►� I HERESY CERTIFY THAT THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW' WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. I AM A DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE FLORIDA. JAMES H. ART DATE - MAY 0, 2011 DATE ISSUED 63167 BEG. N0. BUFFALO WILD VINGS CONSTRUCTION DEPARTMENT 5500 WAYZATA BLVD., STE 1600 MINNEAPOLIS, MN 55416 PHONE (952) 59 --"43 FAX (552) 593 -9757 EDMOND FARRAN THE SHOPS AT SUNSET PACE 5701 SUNSET DRIVE, 113 13A SOUTH MIAMI, FL 33143 FRANr>iISEE SETH DEKANTER EMAIL- sathidakC hetmatl.csm FRANCHISE STORE SHEET TIT LE: i�lASTE do VENT DETAILS PERMIT ET REVISIONS: NO: DATE: BY- PROJECT NO: 111136.001 .. DRAWN BY: . Mel p 1 0 1 j 5770.11 COPYRIGHT PATRICK G. SLEES, AIA 2011