Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-516-034
M IL OI SEE DEVIL 3/E110 FOR WII Lutrsn cable GRX —C2L -346: (Nor,— Plenum) or GRX —PCIL -3465 (Plenum retd). Otherwise use 2 #1 AWG (1.0mm2) and 1 Melds #1461 (•r quWalont). 2f12 AWG (2.5mm2) ❑ Input Power. Use 2 #12 AWG (2.5mm2). u M N f` O 17 C14 IN N NEUTRAL 120V VIA HMECLOC P7 -1 LIGHTING CONTACTOR LC1 EXTERIOR SIGNAGE AND LIGHTING A. PROVIDE ELECTRICALLY HELD CONTACTOR WITH 120V COIL, NORMALLY OPEN 3OA /1P RATED CONTACTS. CONTACTOR SHALL FAIL WITH CIRCUITS IN "ON" CONDITION. MAIN UNIT 1 GRX - 3506 -T -WH 6 ZONE CONTROL UNIT 4 GANG US DEEP BACKBOX SCENES 1 - 4, R /L, AND OFF NEW ROOM 1 GRX ADDRESS: Al I5�LUTRON DIMMING SYSTEM E110 SCALES NONE RESTROOM LIGHTING AND EXHAUST FAN KITCHEN LIGHTING BAR LIGHTING DINNING 3 NEON SIGNS DINNING 3 NEON SIGNS DINNING 3 NEON SIGNS DINNING B NEON SIGNS RESTROOM AND LATE NIGHT BWW SIGNS DISPLAY WINDOW RECEPTACLES SPARE LIGHTING CONTACTOR LC2 INTERIOR ALL OFF A. PROVIDE ELECTRICALLY HELD CONTACTOR WITH 120V COIL, NORMALLY OPEN 3OA /1P RATED CONTACTS. CONTACTOR SHALL FAIL WITH CIRCUITS IN "ON" CONDITION. FLUO. ZONE: DM -1A FLUO. ZONE: DM-1B FLUO. ZONE: DM -2A FLUO. ZONE: DM -21i FLUO. ZONE: DM -3 FLUO. ZONE: DM -4 INC. 9 ZONE: DM -5 INC. FLUID. bl.ZONE: DM -6A FLUO. 9 ZONE: DM -6B G PC PROGRAMMING k TIMECLOCK 4" SQUARE BOX NEW ROOM 1 ADDRESS: 16 DIMMING SCHEDULE Zone NEUTRAL Voltage Laaoi Type 120V VIA DINING D1 LIGHTS 120V, 20A TIMECLOC EXTERIOR SIGNS P1 -1 EXTERIOR SIGNS DINING D1 LIGHTS EXTERIOR SIGNS DIM -28 EXTERIOR SIGNS FLUOR. EXTERIOR SIGNS 120V, 20A EXTERIOR SIGNS SPARE LIGHTING CONTACTOR LC1 EXTERIOR SIGNAGE AND LIGHTING A. PROVIDE ELECTRICALLY HELD CONTACTOR WITH 120V COIL, NORMALLY OPEN 3OA /1P RATED CONTACTS. CONTACTOR SHALL FAIL WITH CIRCUITS IN "ON" CONDITION. MAIN UNIT 1 GRX - 3506 -T -WH 6 ZONE CONTROL UNIT 4 GANG US DEEP BACKBOX SCENES 1 - 4, R /L, AND OFF NEW ROOM 1 GRX ADDRESS: Al I5�LUTRON DIMMING SYSTEM E110 SCALES NONE RESTROOM LIGHTING AND EXHAUST FAN KITCHEN LIGHTING BAR LIGHTING DINNING 3 NEON SIGNS DINNING 3 NEON SIGNS DINNING 3 NEON SIGNS DINNING B NEON SIGNS RESTROOM AND LATE NIGHT BWW SIGNS DISPLAY WINDOW RECEPTACLES SPARE LIGHTING CONTACTOR LC2 INTERIOR ALL OFF A. PROVIDE ELECTRICALLY HELD CONTACTOR WITH 120V COIL, NORMALLY OPEN 3OA /1P RATED CONTACTS. CONTACTOR SHALL FAIL WITH CIRCUITS IN "ON" CONDITION. FLUO. ZONE: DM -1A FLUO. ZONE: DM-1B FLUO. ZONE: DM -2A FLUO. ZONE: DM -21i FLUO. ZONE: DM -3 FLUO. ZONE: DM -4 INC. 9 ZONE: DM -5 INC. FLUID. bl.ZONE: DM -6A FLUO. 9 ZONE: DM -6B G PC PROGRAMMING k TIMECLOCK 4" SQUARE BOX NEW ROOM 1 ADDRESS: 16 DIMMING SCHEDULE Zone Description /Fixture Type Voltage Laaoi Type DIM -1A DINING D1 LIGHTS 120V, 20A FLUOR. DIM -13 DINING- NIGHT LIGHTS D1 LIGHTS 120V, 20A FLUOR. DIM -2A DINING D1 LIGHTS 120V, 20A FLUOR. DIM -28 DINING- NIGHT LIGHTS D1 LIGHTS 120V, 20A FLUOR. DIM -3 15AR C k C1 LIGHTS 120V, 20A FLUOR. DIM -4 SPARE 120V, 20A FLOUR. DIM -5 ORDERING, QUEUING B LIGHTS 120V, 20A INC DIM -6A ENTRY, ORDERING, TAKEOUT C 4c C1 LIGHTS 120V, 20A FLUOR. DIM -66 ENTRY, ORDERING- NIGHT LIGHTS C k C1 LIGHTS 120V, 20A I FLUOR. LIGHT FIXTURE SCHEDULE ME DESCRIPTION FURNISHED BY INSTALLED NY MANUFACTURER MODEL III A OUTDOOR DOWNLIGHT C.M. ELEC CONTR PRESCOLITE CFTD832HD- STFDf02HPL- 11-124 All OUTDOOR FLUORESCENT SIGN FIXTURE C.M. ELEC CONTR COLUMBIA 3LA4- 1 --44HO -921 I LOW VOLTAGE MONO -POINT C.M. ELEC CONTR CON -TECH MCT -24163 MLA1012LVI/MLA1816 C FLUORESCENT RECESSED DOWNLIGHT C.M. ELEC CONTR PRESCOLITE CFC3642TH -DM -120 ADVMARKX - STCB6A -WH -WT C1 FLUORESCENT RECESS® DOWNLIGHT C.M. ELEC CONTR PRESCOLITE CFCI642THEB- DM- MW26- STCB6A -WH W 1 ELECTR. DIMMING BALLAST CF PAT10 CEILING FAN (IF APPLICABLE) C.M. ELEC CONTR CRAFTMADE OPXL52 -Fl D1/EM 8" DIA BLACK CYLINDER FIXTURE WITH 90 MINUTE EMERGENCY BATTERY C.M. ELEC CONTR SOLERA SRBC- 2- PLT26- 120-0- SGB -BLK CNP- BWW -MKX D2 EXTERIOR DOWN LIGHT C.M. ELEC CONTR GOTHAM CFZ12- 2- 26DTT -84P- 120- WLI• -DBL EM -1 DUAL EMERGENCY HEADS WITH BATTERY BACKUP C.M. ELEC CONTR DUAL -LITE LZ12 -BLACK EM -2 WEATHERPROOF EMERGENCY LIGHT C.M. ELEC CONTR DUAL -LITE OCR-S-4-VERIFY VOLTAGE EX -1 EXIT SIGN WITH DIRECTIONAL CHEVRON (SEE PLANS) C.M. ELEC CONTR DUAL -LITE LXURBE EX -2 BLACK COMBINATION EMERGENCY Q EXIT TWO HEAD C.M. ELEC CONTR DUAL -LITE LTURB --3 -1111LACK F UNDERCAIINET W ROCKER SWITCH 1 5/16'H X 38 "L X 5 'D C.M. ELEC CONTR AIREY-THOMPSON 12- 1- 17Ti -0 F1 UNDERCABINET W ROCKER SWITCH 1 5/16-H X 481 X 5 "D C.M. ELEC CONTR AIREY- THOMPSON 12- 1- 32TI -0 H1 WALL SCONCE C.M. ELEC CONTR LIGHTOLIER 4909 -BK H2 WALL SCONCE C.M. ELEC CONTR LIGHTOLIER 3660 -IK J2 COVE LIGHT C.M. ELEC CONTR LITHONIA C225- MVOLT-- OSIOIS K LOW VOLTAGE LE.D. STIP LIGHT - UNDER CABINET LIGHTING C.M. ELEC CONTR WAC LIGHTING LED -T24 -5 L EXTERIOR WALL BRACKET C.M. ELEC CONTR KIM LIGHTING CFL1 -42PL- 120 -5L -Ps N FIBERGLASS FLUORESCENT ENCLOSED k GASKETED, WET LOCATION, HIGH OUTPUT C.M. ELEC CONTR BY COOLER MANUFACTURE M FIBERGLASS FLUORESCENT ENCLOSED h GASKETED, WET LOCATION, HIGH OUTPUT C.M. ELEC CONTR COLUMBIA LTG. WN4- 248HO- 120 -DR -NSF R5 EM 2' X 4' TROFFER FIXTURE WITH 90 MINUTE EMERGENCY BATTERY C.M. ELEC CONTR LITHONIA 2GT9432- AI2- MVOLT- GE310 -IS/ EL14 FOR EM BATTERY R7 EM 2' X 2' PARABOLIC FIXTURE WITH 90 MINUTE EMERGENCY BATTERY C.M. ELEC CONTR LITHONIA 2PM3N- GI- 2U316- 91D- MVOLT -GEB1 IS/ EL14 FOR EM BATTERY W 2" EXTERIOR WALL CYLINDER SCONCE C.M. ELEC CONTR INTENSE LTG IVWC10CF2420L Z EXTERIOR WALL PACK C.M. ELEC CONTR LITHONIA TWH- 150M- TBSC -WAUPT ZIA EXTERIOR POLE LIGHT C.M. ELEC CONTR ARCHITECTUAL AREA LIGHTING ALB14W-SSHGINC- ILK --120- FRAI- 4125FM -DO -P POLE- VALMONT 0200 - 4040454 I ' I I GENERAL NOTES:, 1. ALL FIXTURES IN THE BAR AND FOOD PREP AREAS SHALL HAVE SHATTER -PROOF LENSES. 2. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING MOUNTING HEIGHTS. 3. NO SUBSTITUTIONS FOR FRONT OF HOUSE FIXTURES. 4. C.M. TO PURCHASE LIGHTS AND FIXTURES. LIGHTING CONTACTOR CONTROL NOTES: 1. CONTACTORS ARE SHOWN WITH TYPICAL LOADS AND CIRCUIT ASSIGNMENTS. LOADS, CIRCUIT ASSIGNMENTS AND NUMBER OF CONTACTORS MAY VARY BY RESTAURANT LOCATION, VERFIY EXACT REQUIREMENTS WITH FLOOR PLANS, ELECTRICAL PANEL SCHEDULES AND PROJECT MANAGER. EC SHALL MAKE ALL MODIFICATIONS AS REQUIRED. EC TO ATTAIN INFORMATION ON ANY ADDITIONAL ENERGY CODE REQUIREMENTS FROM LOCAL AUTHORITY. 2. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL WIRING, CONNECTIONS, TERMINATIONS, EQUIPMENT, RELAYS, SWITCHES, CABINETS, AUXILIARY CONTACTS, ETC. FOR A COMPLETE, FULLY OPERATIONAL AND CODE COMPLIANT LIGHTING CONTROL SYSTEM. 3. ALL COMPONENTS FOR THIS LIGHTING CONTROL SYSTEM SHALL 15E FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 4. ALL COMPONENTS SHALL BE UL LISTED AND LABELED. 5. ALL CONTACTORS SHALL BE LOCATED IN A NEMA 1 ENCLOSURE WITH SCREW TYPE COVER MOUNTED AS DIRECTED BY OWNER /ARCHITECT. G. ALL CONTACTORS SHALL BE RATED FOR 30 AMP LOADS UNLESS OTHERWISE NOTED. 7. COIL VOLTAGES FOR ALL CONTACTORS SHALL BE 120 VOLT UNLESS OTHERWISE NOTED. S, THE CONTACTOR SHALL BE UL LISTED FOR A MINIMUM 10,000 AMPS RMS SYMMETRICAL INTERRUPTING CAPACITY FOR THE CONTACTOR SHORT CIRCUIT WITHSTAND RATING, 9, ASCO 641A TIMECLOCK ASSEM15LY AND ENCLOSURE A THE ASCO MODEL 641A LIGHTING CONTROL PANEL PERMITS MANUAL AND AUTOMATIC 11ME CLOCK /PHOTOCELL CONTROL OF 4, i, OR 12 LIGHTING CIRCUITS RATED 20 AMPERES. B. IDEALLY SUITED FOR AUTOMATIC AND MANUAL ON /OFF COLOR CONTROL OF PARKING LOT LIGHTING, SIGNS, BUILDING EXTERIOR AND INTERIOR SAFETY LIGHTING, AND SECURITY k RECREATION LIGHTING AREAS. C. IN AUTOMATIC MODE, THE PANEL USES A TIME CLOCK AND A REMOTE PHOTOCELL SIGNAL TO CLOSE THE CONTACTOR; THE TIME CLOCK OPENS THE CONTACTOR AT A PRESET TIME. D. LIGHTS CAN BE TURNED ON AND OFF MANUALLY WITHOUT OPENING PANEL, BY USING THE H -O -A SWITCH ON THE FRONT DOOR. 3- POSI1ION DOOR CONTROL SWITCH: MANUAL - CONTACTOR CONTACTS CLOSED - LIGHTS ON. OFF - CONTACTOR CONTACTS OPEN - LIGHTS OFF. AUTOMATIC - TIME CLOCK OPERATES CONTACTOR AT PRESET TIME IF PHOTOCELL INDICATES A NEED FOR LIGHTING. REFER TO CONTACTOR WIRING DIAGRAMS FOR ADDITIONAL INFORMATION. MOUNTED TO UNDERSIDE OF DECK OR STRUCTURE PER N.E.C. (PAINT BLACK) 'PROVIDE MIDWEST /CROUSE HINDS (PART # TPRFHI2) SWIVEL. METAL CONDUIT - LENGTH AS REQUIRED TO POSITION FIXTURE AT 12' -6" A.F.F. (PAINT BLACK) ��-- FIXTURE CANOPY WITH INTEGRAL TRANSFORMER k J -BOX MOUNTED TO UNDER SIDE OF DECK OR STRUCTURE PER N.E.C.. PROVIDE CON -TECH DIMMABLE CANOPY TRANSFORMERS MLA- 1816.(PAINT BLACK) FIXTURE STEM EXTENSION SYMPHONY #MLA1OXXLV -3 SERIES 12" -TYPE 1' FIXTURE VERIFY INSTALLATION METHOD /STEM LENGTH AT ALL TYPE B FIXTURE INSTALLTION LOCATIONS 4 1B` FIXTURE MOUNTING E110 SCALE: NO SCALE N I PHPM- PA -DV -WH TO GRAFIK EYE MOUNTING LAMPS FIXTURE VA VOLTS RECESSED (1) 42W CFL 100 120 END ARM MOUNT (1) F48T12 /CW/H0 140 120 MONOPOINT (1) Q50MR16 /C/FL.40 EXN 50 120 RECESSED (1) F26TBX 830 /A/ECO 28 120 RECESSED (1) F26T3X 230 /A/ECO 28 120 SURFACE - 150 120 PENDANT (1) 26W TRT 28 120 SURFACE (1) 26W DTT 22 120 SURFACE rri 30 120/277 SURFACE ❑ Z HIM2 8 VERIFY SURFACE 8 120 SURFACE 30 120 SURFACE F - F25T8 /SP41/ECO SPEAKER - SEE ELEC. DWGS. 120 SURFACE Ft - F32Ti /SP41/ECO GYPSUM BOARD CEILING - SLI A705 FINISH SCHEDULE FOR PAINT COLORS 120 SURFACE (1)100 W Ala 100 120 SURFACE (1)100 W A1! 100 120 RECESSED (2)F25Ti 46 120 SURFACE LED STRIP 2W/FT 24V SURFACE (1) F42TBX 44 120 SURFACE LED 50 120 SURFACE (2) F4ST12 /CW/HO 130 120 RECESSED (4) F32T9/SP41 CO 108 120 RECESSED (2) F31Ti /SP41/EC0 54 120 SURFACE (2) 42WTBX ai 120 SURFACE (1) 150W MH PULSE START 175 120 POLE (1) 32W SPIRAL C.F. 32 120 • • W••4V VVV U v • U U J' V, Y N • • x PATRICK • W .;.:r:s .0 BALLAST REMARKS T.7 1 c G'` (1) ELECT. Woe �. �J l� w�. �7 NOTE #3. PROVIDE WITH BLACK FINISH. PATRICK G, BLESS. AI'�CHITECT (1) ELECT. PROVIDE 12" STEMS FOR EIGHT (i) B' FIXTURES OVER IAA • . Y . • • ° Y " • V • �V+ Y DIMMING T GYPBOARD CEILING- REFER TO LIGHTING PLAN FOR LOCATION.- y��r� N'tEi� S r•s RS�%ITE 301 DIMMING Y � u „ U . ,H 1 N_Eh".'� LI :, - �= "55401 (1) ELECT. ACOUSTICAL CEILING PHONE: (612) 338 -6677 DIMMING I FAX: (61) 338 --2995 E —MAIL: info!0cmarch.com (1) ELECT. J -BOX MOUNTED TO BOTTOM SIDE OF DECK. SEE DETAIL Ik2/E110 DIMMING "EM" FIXTURES SHALL BE CONNECTED WITH UNSWITCHED CIRCUIT t (1) ELECT. J-BOX MOUNTED TO BOTTOM SIDE OF DECK. SEE DETAIL 1k2/'E170 DIMMING CONSULTANTS: MOUNT BOTTOM AT APPROX. 13' -0" AFF (ABOVE PAINT LINE) UNLESS NOTED OTHERWISE. VERIFY EXACT LOCATION WITH WILLIAM F. T H I E S S E, P.E. ARCH PRIOR TO ROUGH -IN -- MOUNT AT 9' -0" AFT. VERIFY VOLTAGE, REUSE EXISTING 305 2ND ST NW, SUITE 105 WIRING, CONNECT TO EXISTING EXIT SIGN. NEW BRIGHTON, MN 55112 BLACK HOUSING, MOUNT BOTTOM AT a' -0" AFT PHONE: (651) 632 - -2300 -- MOUNT BOTTOM AT 8' -0' AFF FAX: (651) 632 -2397 (1) ELECT. MOUNT UNDER BAR WHITE, PRISMATIC LENS VERIFY WITH ARCHITECT (1) ELECT. MOUNT UNDER BAR WHITE, PRISMATIC LENS VERIFY WITH ARCHITECT E (1) ELECT. (1) ELECT. COW TRANSFORMER PROVIDED WITH KIT. MOUNT AT SERVER STATIONS ABOVE WORK CEILING IN NEMA 1 ENCLOSURE ® PROVIDE FACTORY WALL MOUNTING HARDWARE (1) ELECT. LAMPS AND FIXTURE SHALL BE PROVIDED BY COOLER MANUFACTURES (1) MAG. LAMPS SHALL BE PROVIDED BY BWW VENDER (FD LAWRENCE) (1) ELECT. "NL' FIXTURES SHALL BE CONNECTED WITH UNSWTCHED CIRCUIT (1) ELECT. "NL" FIXTURES SHALL BE CONNECTED WITH UNSWITCHED CIRCUIT b L COLOR AS SELECTED BY C.M. LIGHTING SYMBOLS LEGEND Q J -LOX ® SUPPLY AIR DIFFUSER - REF MD' DWGS FOR SIZE INFORMATION CEILING HEIGHT A.F.F. CEILING TYPE /FINISH 0 OUTLET OA CANOPY LIGHT - - - - - - UNDERCOUNTER STRIP LIGHT b L EXTERIoR STEM LIGHT RETURN AIR DIFFUSER -REF MET DWGS FOR SIZE INFORMATION Al 41' TROUGH LIGHTING 0C /D RECESSED OR SUSPENDED CAN LIGHT FIXTURE ' EXTERIOR CEILING FAN .STAG V PENDANT MONO POINT LIGHT TYPICAL 2' -0' FROM WALL, UNLESS NOTED OTHERWISE R4 2'X4' FLUORESCENT LIGHT FIXTURE 1� JUNCTION BOX FOR POSSIBLE MONO POINT LIGHT LOCATIONS. TYPICAL 2' -0" FROM WALL 8 S -0" O.C., UNLESS OTHERWISE NOTED EM -1 • EMERGENCY IATTT]tY LIGHT El 2'X2' FLUORESCENT LIGHT FIXTURE SUSPENDED PGEELS. W)ITTyr.N VNYL- FACED rri EXIT AND EMERGENCY BATTERY LIGHT ® N TYPE MOISTURE -PROOF FIXTURE SUPPLIED BY COOLER MANUFACTURER - LAMPS PROVIDED BY OWNER ❑ Z HIM2 EXTERIOR WALL PACK LIGHT FIXTURE COMPACT FLUORESCENT WALL SCONCE �W NEW EXTERIOR LIGHT JUSPENDED GRID WITH LAY-IN ACOU`TIC CEILING TILE C -A TELEVISION BY OWNER - SEE ELEC. DWGS. T.V. PROJECTOR BY OWNER - SEE ELEC. DWGS. F /F1 © UNDER BAR LIGHT FIXTURE 4 SPEAKER - SEE ELEC. DWGS. Ir TRACK LIGHTING SYSTOJ GYPSUM BOARD CEILING - SLI A705 FINISH SCHEDULE FOR PAINT COLORS VIDEO CAMERA SEE ELEC. COMMUNICATION PLAT DWGS. TO LIGHTS 2P2T RELAY FUNISHED BY ELEC CONTRACTOR CONTROLLER 1 N H SPST SWITCH FURNISHED BY ELEC CONTRACTOR TO CONTROL 3 RELAYS FOR NIGHT LIGHT SYSTEM. PROVIDE POWER FROM NEAREST 120V UNSWITCHED CIRCUIT. LABEL SWITCH AS NIGHT LIGHTS. SWITCH TO BE LOCATED ADJACENT TO DIMMING CONTOL. LUTRON DIMMING SYSTEM NIGHT LIGHT DETAIL. E110 SCALE, NONE STANDING METAL SEAP ROOFING. -1/2" RIGID INSULATED METAL DECK. CREW WIRING J -BOX TO PATIO CEILING SHEET METAL. ROVIDE MIDWEST /CROUSE HINDS (PART # TPRFHI2) SWIVEL 1/2" BLACK PENDANT SUPPLIED WITH FIXRURE. CUT TO APPROPRIATE LENGTH ON JOBSITE. TYPE "D2' FIXTURE I Oe, t W im V Iz FINISHED FLOOR PATIO TYPE D2 K'_2_'�DEI"AIL PA1l. ,W RX1111! mm, !110 NO SCALE SUSPENDED FROM TOP CHORD Ot SUPPLEMENTAL FRAMING (TYPICAL). PROVIDE 4" ROUND JUNCTION BOX. ___�J BOX BY ELECTRICAL CONTRACTOR. = PROVIDE MIDWEST /CROUSE HINDS (PART f. TPRF11I2) .: WAIVEL BLACK PENDANT BY ELECTRICAL CONTRACTOR. CUT TI APPROPRIATE LENGTH ON JOBSIT ��J -BOX GY ELECTRICAL CONTRACTOR _L TYPE 'Di' FIXTURE I` °o mO J v Cs s I Cq 2 FINISHED FLOOR 1 DETAIL .». �, „• �. 1110 NO SCALE SEAL: E IN '`/tWti1l11 /1)Jj�j • N 55 71 • •� •� r_ I HERESY CERTIFY THAT THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE; CHARGE. I AM A DULY REGISTERED ENGINE=ER UNDER THE LAWS OF THE STATE; FLORIDA. WILLIAM F. THIESSE MAY 20, 2011 DATE ISSUED 55971 REG. NO. BUFFALO WILD 'WINGS CONSTRUCTION DEPARTMENT 5500 WAYZATA BLVD., STE 1600 MINNEAPOLIS, MN 55416 PHONE (952) 51Z -9943 FAX (952) 593 -9797 EDMOND FARRAN THE SHOT'S AT SUNSET PLACE 5701 SUNSET DRIVE, #1313A SOUTH MIAMI, FL_ 331 43 FRANCHISEE- SETH DEKANTER EMAIL: ssthiokQh*tmsll.cam FRANCHISE SWORE SHEET TITLE: LIGHTING DETAILS AND SCHEDULES PERMIT SET REVISIONS: NO: DATE: BY: I- PROJECT N0: 11136.001 DRAWN BY: DWI E 1 10 r 5770.11 COPYRIGHT PATRICK G. GLEES, AIA 2011