Loading...
11-516-028Albs u M N n N ti GENERAL NOTES: 1. KITCHEN VENDOR TO PROVIDE REMOTE CONDENSERS ON ROOF FOR FOR ALL COOLERS, FREEZERS is ICE MACHINES. COORDINATE CONDENSATE LINE LOCATION WITH WITH REMOTE CONDENSER LOCATIONS ON ROOF. 2. ALL EQUIPMENT USED ON THIS PROJECT IS SHALL BE UL LISTED AND BEAR THE UL 710 LISTED LABEL 3. DUCT SMOKE DETECTORS SHALL PROVIDE SHUT DOWN IN 30 SECONDS OR LESS 'MECHANICAL SYMBOLS SYMBOL DESCRIPTION SYMBOL DESCRIPTION CFM PER PERSON DIRECTION OF FLOW CFM REQUIRED LINED DUCTWORK ® THERMOSTAT 7.5 RECTANGULAR ELBOW WITH TURNING VANES © TEMPERATURE SENSOR YYYYYIN ROUND FLEXIBLE DUCT CONNECTION 7.5 HUMIDITY SENSOR 2081 RO DEGREE ELBOW DOWN --- G<— GATE VALVE 5 90 DEGREE ELBOW UP —1�1— CHECK VALVE} 1525 FLEXIBLE DUCT CONNECTION 0 STRAINER ® SUPPLY AIR DEVICE — —I— UNION � DUCT SIZE TRANSITION RESTROOMS PRESSURE GAUGE CHWS CHILLED WATER SUPPLY 0 THERMOMETER CHWR CHILLED WATER RETURN E.A. EXIIAUST AIR CWS CONDENSER WATER SUPPLY (D—F.D. FIRE DAMPER CWR CONDENSER WATER RETURN H.O.A. HAND - OFF - AUTOMATIC HWS HOT WATER SUPPLY N.C. NORMALLY CLOSED HWR HOT WATER RETURN N.O. NORMALLY OPEN RS REFRIGERANT SUCTION M.A. MIXED AIR RL REFRIGERANT LIQUID O.A. OUTSIDE AIR FOT FLAT ON TOP REL A. RELIEF AIR -D CONDENSATE DRAIN PITCHED R.A. RETURN AIR — — BACKDRAFT DAMPER SD DUCT OR UNIT MOUNTED SMOKE DETECTOR �— POINT OF CONNECTION MANUAL BALANCING DAMPER O SMOKE DETECTOR REMOTE RESET SWITCH R— MOTORIZED DAMPER © CO2 DETECTOR Z CEILING RETURN AIR DEVICE NOTE: NOT ALL SYMBOLS PRO MAY ON THIS SUPPLY DUCT RISER AM -1 8A. OUTSIDE AIR REQUIREMENTS OCCUPANCY TYPE GROSS FLOOR AREA SO. FT. PEOPLE REQUIRED OUTSIDE AIR BASED ON ASHRAE 62 2004 CFM PER PERSON CFM PER SQ. FT. CFM REQUIRED BAR 853 15 7.5 0.18 266 DINING 2656 215 7.5 0.1E 2081 OFFICE 78 0 5 0.06 5 KITCHEN 1525 15 0 0.7 1068 STORAGE /UTILITY 500 0 0 0.12 60 RESTROOMS 389 6* 50* 0 300 TOTALS 6001 245 — — 3790 *BASED ON 6 FIXTURES AT 50CFM /FIXTURE AIR BALANCE SCHEDULE TAG CFM SUPPLY CFM RETURN CO2 /OA MIN. CO2 /OA MAX. * CFM EXHAUST* IX —AHU -1 4620 1125 RG -1 800 1200 — EX —AHU -2 3740 1120 TITUS MODEL N0, 50F; FINISH TO MATCH CEILING/WALL COLOR. TYPE 3 FRAME. PROVIDE BALANCING DAMPER. 1000 1600 — IX —AHU -3 2080 310 EWT -F 300 600 — IX —AHU -4 4340 1240 1800 1000 1600 — EF -1 — — 45 — — 4900 EF -2 — — 1800 — — 450 EF -3 — — 45 - — — I CARRIER 39LA06KA—AL—ARN-19I 2080 720 12 70 1 60 TOTAL 14780 3795 45 3100 5000 5350 AIR BALANCE: 350 CFM NEGATIVE PRESSURE NOTE- AIR BALANCE SHALL BE PROVIDED BY GENERAL CONTRACTOR— OWNER APPROVED AIR BALANCING CONTRACTOR. *BASED ON UPPER LIMIT OF MINIMUM OUTDOOR AIR INTAKE, USING CO2 CONTROL INTAKE /EXHAUST WILL BE HIGHER IN THE ATMOSPHERIC COOLING MODE, USING THE ECONOMIZER CONTROL FEATURE. DIFFUSER SCHEDULE TAG DESCRIPTION DD -1 TITUS MODEL HERO BLADE 13285; FINISH BLACK, PROVIDE OPPOSED BLADE DAMPER. DD -2 TITUS MODEL HERO BLADE 301RL; FINISH WHITE, NO DAMPERS. CD -1 TITUS MODEL NO. TMSA; COLOR TO MATCH CEILING. SIZE AS INDICATED. PROVIDE OPPOSED BLADE DAMPER. TYPE 3 FRAME. ** CD -2 TITUS MODEL NO. TMRA; COLOR TO MATCH CEILING. SIZE AS INDICATED. PROVIDE OPPOSED BLADE DAMPER. TYPE 1 FRAME. RG -1 TITUS MODEL NO. 50F; COLOR TO MATCH CEILING. ME 3 FRAME. PROVIDE BALANCING DAMPER. RG -2 TITUS MODEL NO. 350ZL; COLOR TO MATCH DUCT OR WALL TYPE 1 SURFACE MOUNT FRAME. PROVIDE BALANCING DAMPER. TG -1 TITUS MODEL NO. 350ZFL; FINISH TO MATCH WALL TYPE 1 FRAME. PROVIDE BALANCING DAMPER. WALL — MOUNTED. EG -1 TITUS MODEL N0, 50F; FINISH TO MATCH CEILING/WALL COLOR. TYPE 3 FRAME. PROVIDE BALANCING DAMPER. ** DIFFUSERS IN DINING AND B SHALL BE BLACK. DIFFUSERS IN KITCHEN AND OFFICE SHALL BE WHITE. PAINT ALL OTHER DIFFUSERS TO MATCH CEILING COLOR ELECTRIC DUCT HEATER SCHEDULE UNIT NO. MANUFACTURER MODEL SIZE KW /STAGES BTUH NOTES DH -1 INDEECO QUA — SLIP —IN 10X8 1.5 KW /1 STAGE 15,355 1, 2, 3 NOTES: 1. PROVIDE THERMAL CUTOUT, AIR FLOW SWITCH, DOOR INTERLOCK DISCONNECT SWITCH AND STEP CONTROLLER. 2. CONTROLS SHALL BE COMPATIBLE WITH ROOF TOP UNIT CONTROLS. 3. PROVIDE FACTORY 24 VOLT THERMOSTAT WITH REMOTE SENSOR. AIR HANDLING UNIT SCHEDULE (EXISTING UNITS) SHEET TITLE: il..,. U4L+tG V i• MECHANICAL SCHEDULES CFM O.A.CFM ELECTRIC HEATING SECTION KW CHILLED WATER COOLING COIL NO: DATE: i. P(per }y.�(' / /�_, t' .-AT4 ,-1 I C UNIT MANUFACTURER MODEL TOTAL PROJECT NO: PATRICK G. FLEES, ARwHITECT TOTAL MOH j 4 v cj -- 219 N. 2Nb St., S�61TF� 301 F ROWS / FPI GPM EWT -F LWT -F NOTES EX—AHU -1 CARRIER 39LAIOKA— AQ— AMJ -19 4620 1800 20 184 142 6 / 12 31.01 45 57 1. EX— AHU -2 CARRIER 39LAOIKA—AQ—APS-191 3740 1800 20 151 73.5 6 / 9 150.8 45 57 1. EX— AHU -3 I CARRIER 39LA06KA—AL—ARN-19I 2080 720 12 70 1 60 6 / 12 1 76.0 45 57 1. IX— EX-4 CARRIER 39LA12KA— AS— AW -191 4340 2160 20 187 167 6 / 12 221.7 45 57 1. NOTES: 1. CLEAN, SERVICE AND REFURBISH ALL EXISTING AIR HANDLING UNITS. GREASE AND LUBRICATE FANS AND BEARINGS. UNIT HOUSINGS SHALL BE CLEANED INSIDE AND OUT OF ALL DEBRIS AND DUST. REPLACE AND RE— TENSION FAN BELTS. REPLACE AND /OR REPAIR DOOR LATCHES AND UNIT CLOSURES AS REQUIRED FOR PROPER OPERATION. CLEAN AND SERVICE ALL EXISTING ASSOCIATED DAMPERS. LUBRICATE ALL DAMPER SHAFTS BEARINGS AND LINKAGES. REPLACE ALL DAMAGED BROKEN DAMPERS AND LINKAGES. FIELD VERIFY THAT ALL DAMPERS CAN MODULATE THROUGH FULL RANGE OF OPERATION (0% — 100% OPEN) AFTER REPAIRS HAVE BEEN MADE. REPLACE/REPAIR ALL DAMAGED BLADE SEALS. AM -1 8A. SCALE BASED ON A 30 "x42" SHEET SIZE CONSULTANTS. JAMES H. ART, P.t 305 2ND ST NW, SUITE -105 NEW BRIGHTON, MN 55112 PHONE: (651) 632 -2300 FAX: (651) 632 --2397 SEAL: �1 \8t��111I1/8��j No 6 7 • w • r �" Y* STATE OF ": •,,�� 16", toopx %twilts- HEREBY CERTIFY THAT TIME PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. 1 AM A DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE FLORIDA. JAM -7S H. ART MAY 20, 2011 DATE ISSUED 63167 P.EG. N0. BUFFALO WILD CONSTRUCTION DEPARTMENT 5500 WAYZATA FSLVD., STE 1500 MINNEAPOLIS, MN 55416 PHONE (952) 593 -9943 FAX (252) 593, -/787 EDMOND FA.RRAN THE SHOPS AT SUNSET PLACE 5701 SUNSET DRIVE,: ID13A SOUTH MIAMI, FL` 33143 FRANCHISEE: SETH DEKANTER EMAIL sethdekVietmellxom FRANCHISE STORE SHEET TITLE: il..,. U4L+tG V i• MECHANICAL SCHEDULES PERMIT 'SET REVISIONS: NO: DATE: i. P(per }y.�(' / /�_, t' .-AT4 ,-1 I C i i ua �G uBL, -EES i i. PROJECT NO: PATRICK G. FLEES, ARwHITECT � • V j 4 v cj -- 219 N. 2Nb St., S�61TF� 301 MIW417kPOLIS_. °MN �55401 `• PHORL (612) —6677 FAX: (612) 338 -2995 E —MAIL: Info0cmarch.com CONSULTANTS. JAMES H. ART, P.t 305 2ND ST NW, SUITE -105 NEW BRIGHTON, MN 55112 PHONE: (651) 632 -2300 FAX: (651) 632 --2397 SEAL: �1 \8t��111I1/8��j No 6 7 • w • r �" Y* STATE OF ": •,,�� 16", toopx %twilts- HEREBY CERTIFY THAT TIME PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. 1 AM A DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE FLORIDA. JAM -7S H. ART MAY 20, 2011 DATE ISSUED 63167 P.EG. N0. BUFFALO WILD CONSTRUCTION DEPARTMENT 5500 WAYZATA FSLVD., STE 1500 MINNEAPOLIS, MN 55416 PHONE (952) 593 -9943 FAX (252) 593, -/787 EDMOND FA.RRAN THE SHOPS AT SUNSET PLACE 5701 SUNSET DRIVE,: ID13A SOUTH MIAMI, FL` 33143 FRANCHISEE: SETH DEKANTER EMAIL sethdekVietmellxom FRANCHISE STORE M 0,2 /2 Y 5770.11 COPYRIGHT PATRICK G. BLESS, AIA 2011 SHEET TITLE: MECHANICAL SCHEDULES PERMIT 'SET REVISIONS: NO: DATE: BY: i i i i. PROJECT NO: r 1113+6.001 DRAWN BY- TCK M 0,2 /2 Y 5770.11 COPYRIGHT PATRICK G. BLESS, AIA 2011