04-04-069ELECTRICAL ABBREVIATIONS WHERE ABBREVIATIONS ARE USED IN THE DOCUMENTS AND NOT LISTED IN THE FOLLOWING, REFER TO ANSI /IEEE STANDARD 100 AND FOR MECHANICAL EQUIPMENT REFER T THE MECHANICAL SYSTEMS ABBREVIATIONS SCHEDULE. A AMPERE AC ALTERNATING CURRENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AL ALUMINUM ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BC BELOW CEILING BKR BREAKER CATV CABLE TELEVISION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING CO CONDUIT ONLY CN TL CONTROL CPU CENTRAL PROCESSING UNIT CU COPPER CT CURRENT TRANSFORMER DC DIRECT CURRENT DIM DIMMER DISC DISCONNECT SWITCH DN DOWN E EMERGENCY EC EMPTY CONDUIT EX EXISTING FAA FIRE ALARM ANNUNCIATOR FACP FIRE ALARM CONTROL PANEL FDR FEEDER FL FLOOR F FUSE OR FUSED FVNR FULL VOLTAGE NON REVERSING GEN GENERATOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GRC OR GRS GALVANIZED RIGID STEEL CONDUIT G OR GND GROUND H OR HT HEIGHT HID HIGH INTENSITY DISCHARGE HP HORSEPOWER HOA HAND - OFF - AUTOMATIC HZ HERTZ ISO ISOLATED J OR JB JUNCTION BOX K KILO, THOUSAND KCMIL THOUSAND CIRCULAR MILLS LED LIGHT EMITTING DIODE M MOTOR MATV MASTER ANTENNA TELEVISION MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MH MAN HOLE MLO MAIN LUGS ONLY MT MOUNT. MTG MOUNTING _ NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NF NON FUSED NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NIL NIGHT LIGHT NO NORMALLY OPEN NTS NOT TO SCALE OC ON CENTER OL OVERLOAD P POLE PC PHOTO ELECTRIC CONTROL PNL PANELBOARD PT POTENTIAL TRANSFORMER PVC POLY -VINYL CHLORIDE R RELAY RC REMOTE CONTROL RECPT RECEPTACLE REF REFERENCE RMS ROOT MEAN SQUARE SFL SUB FEED LUGS SYM SYMMETRICAL SW SWITCH SWBD SWITCHBOARD TBB TELEPHONE BACKBOARD TEL TELEPHONE TV TELEVISION TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR TYP TYPICAL UC UNDER COUNTER UG UNDERGROUND UL UNDERWRITER'S LABORATORY UPS UNINTERRUPTED POWER SUPPLY V VOLTS VA VOLT- AMPERE W WATTS WP WEATHERPROOF XFMR TRANSFORMER XP EXPLOSION PROOF Y WYE _ Z IMPEDANCE _OTTED :Fri Dec 12 09:41:22 2003 iNlT:\ 5200 \52316 \Cad \Etec\52316E01.dwg iER H t ee ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION MTG HT (NOTE L -2)I $ SINGLE POLE SINGLE THROW TOGGLE SWITCH. 48" $3 THREE -WAY TOGGLE SWITCH. 48" $K S.P,S.T, KEY TYPE TOGGLE SWITCH. J U U J sM MANUAL MOTOR RATED SWITCH WITH OVERLOAD PROTECTION. C+ 01500 DIMMER SWITCH, 600 WATTS OR WATTAGE AS INDICATED. 48" 43 3 -WAY DIM, SWITCH, 600 WATTS OR WATTAGE AS INDICATED. 48" J V J - PUSHBUTTON CONTACT SWITCH 48" E� SINGLE RECEPTACLE OUTLET. 1$" �/O U DUPLEX RECEPTACLE OUTLET. WALL / CEILING MOUNTED 1811/ U DOUBLE DUPLEX RECEPTACLE OUTLET. 1$" U J U J J DUPLEX RECEPTACLE OUTLET ABOVE COUNTER. 48" GF & /GF G.F.C,I. DUPLEX RECEPTACLE OUTLET, WALL MOUNTED / ABOVE COUNTER. 18 "/48" IG(t)_- ISOLATED GROUND DUPLEX RECEPTACLE OUTLET. 18" WP()- WEATHERPROOF DUPLEX RECEPTACLE OUTLET. 18" ® FLOOR MOUNTED DUPLEX RECEPTACLE OUTLET. U U ® FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE OUTLET. V i SPECIAL PURPOSE DUPLEX RECEPTACLE OUTLET L -6 18" UUJ SPECIAL PURPOSE FLOOR MTD DUPLEX REC, OUTLET L -6 JJJ AMMETER. VUUJ ®v VOLTMETER. v DED DEDICATED CIRCUIT L -8 U X -1, 3, 5 ARROWHEAD INDICATES HOMERUN. X -1, 3, AND 5 ADJACENT TO HOMERUN ARROWHEADS INDICATES HOMERUN TO PANEL X, CIRCUIT NUMBERS 1, 3, AND 5, L -1,3,9 J / 3,5\ INDICATES CIRCUIT CONTINUATION OF CIRCUITS 3 AND 5 OF PANEL X. L -1,3,9 U U RACEWAY INSTALLED CONCEALED IN WALL AND /OR ABOVE CEILING. J O RACEWAY INSTALLED CONCEALED IN SLAB OR BELOW GRADE. RACEWAY INSTALLED EXPOSED. J J U U U J GROUND. U J J J J U U 0 / • CONDUIT UP / CONDUIT DOWN. CONDUIT STUB -UP ABOVE FINISHED FLOOR. CONDUIT TERMINATION (STUB -OUT), (2 5H /Q] JUNCTION BOX. CEILING / WALL / FLOOR MOUNTED. TELEPHONE TERMINAL BACKBOARD. L -7 / / OUTLET AND FLUORESCENT LIGHT FIXTURE. OVERHEAD / WALL MOUNTED. Q /b--' OUTLET AND INCANDESCENT, H,I,D., OR COMPACT FLUORESCENT LIGHT FIXTURE. OVERHEAD / WALL MOUNTED, <a OUTLET AND INCANDESCENT, H.I.D., OR COMPACT FLUORESCEIN CEILING MOUNTED WALL WASHER, OUTLET AND BATTERY POWERED EMERGENCY LIGHT 80 -96" E OUTLET AND FLUORESCENT STRIP OR INDUSTRIAL LIGHT FIXTURE. " OUTLET AND LIGHTING TRACK WITH LAMP HEADS. L -10 OUTLET AND EXIT LIGHT FIXTURE. CEILING / WALL MOUNTED, PROVIDE ARROWS INDICATED. L -3 OUTLET AND EGRESS AND /OR EMERGENCY LIGHT FIXT. WITH BATTERY PACK. L -3 DFO FIRE ALARM SPEAKER & STROBE CEILING MOUNTED. FA P FIRE ALARM CONTROL PANEL. F❑ FIRE ALARM MANUAL INITIATING STATION. 48" CD FIRE ALARM SPEAKER & STROBE, WALL MOUNTED 6' -8" /OD SMOKE DETECTOR, WALL / CEILING MOUNTED. QH /GH THERMAL DETECTOR, CEILING / WALL MOUNTED. d FIRE SUPPRESSION SYSTEM FLOW SWITCH. QT FIRE SUPPRESSION SYSTEM TAMPER SWITCH. [- DUCT MOUNTED SMOKE DETECTOR, cT CURRENT TRANSFORMER ❑D ELECTRIC METER FT{►. FIRE COMMUNICATIONS TELEPHONE JACK. 48" FT FIRE COMMUNICATIONS TELEPHONE HANDSET 48" Q/Q FIRE ALARM VISUAL SIGNAL, WALL / CEILING MOUNTED. 80 "/- ►/( TELEPHONE OUTLET, WALL MOUNTED / ABOVE COUNTER. L -4 18 "/- PP TELEPHONE OUTLET,PAYPHONE L -4 5401/- > WALL MOUNTED DATA OUTLET, L -5 18" WALL MOUNTED COMBINATION PHONE DATA OUTLET. L -4,5 18" ® FLOOR MOUNTED TELEPHONE OUTLET. L -4 ® FLOOR MOUNTED COMBINATION PHONE DATA OUTLET. L -4,5 6H/ (S WALL CEILING MOUNTED COAXIAL CABLE OUTLET. 18" 0 EQUIPMENT AS INDICATED. FLUSH MOUNTED PANELBOARD. SURFACE MOUNTED PANELBOARD. IT DRY TYPE TRANSFORMER. MOTOR CONNECTION. 60A/3/3R LLI NON- FUSIBLE DISCONNECT SWITCH. RATING / POLES / NEMA ENCLOSURE. 60A/3/3R/40A `z FUSIBLE DISCONNECT SWITCH. RATING / POLES / NEMA ENCLOSURE / FUSE RATING. ❑D CONTACTOR. TS ELECTRONIC TIME SWITCH ® MAGNETIC MOTOR STARTER ® REMOTE SWITCHING STATION q MAGNETIC DOOR HOLDER UUJ JJUJU J J UJJ JUJU J U U 0 J J J U U ej V U J U J J J J U U J JJJ J J U C+ U J J J J U ] J J V J U J E! U JU U O J J UUU JJe, JJJ U e1J U J U U J U U J U J J U U U J J ti, U U J J U J J U U J U U U J U U J J U U U J U V U J UUe] JUJ UUJ UUJJ JJJ tiJJUJ VUUJ J u J v J } J U J J J J J U J J U U J J O J J U U U J J V V U J J J J U U UJJ V LEGEND NOTES: L -1 EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN ALL BRANCH CIRCUIT RACEWAYS. L -2 UNLESS NOTED, MOUNTING HEIGHT DIMENSIONS ARE TO THE CENTER OF THE DEVICE OR OUTLET ABOVE GRADE OR FINISHED FLOOR. L -3 FURNISH AND INSTALL 1" CONDUIT HOMERUNS FROM EACH TELEPHONE OUTLET TO NEAREST TELEPHONE BACKBOARD, UNLESS OTHERWISE INDICATED OR SPECIFIED. L -4 FURNISH AND INSTALL 1" CONDUIT HOMERUNS FROM EACH DATA OUTLET TO NEAREST DATA SYSTEM BACKBOARD: FURNISH AND INSTALL PLENUM -RATED CABLE WITHOUT CONDUIT ABOVE DROP CEILINGS. L -5 SPECIAL PURPOSE RECEPTACLE OUTLET, REFER TO KEYNOTES ON RESPECTIVE DRAWING FOR DESCRIPTION. L -6 TELEPHONE BACKBOARD TO BE PLYWOOD, PAINTED WITH FLAME RETARDANT PAINT. PROVIDE GROUND CONDUCTOR AND DOUBLE DUPLEX RECEPTACLE. SEE SPECIFICATIONS. L -7 DEDICATED CIRCUITS SHALL NOT SHARE A COMMON GROUND OR NEUTRAL CONDUCTOR WITH NON- DEDICATED CIRCUITS. DEDICATED CIRCUITS SHALL BE INSTALLED IN INDIVIDUAL RACEWAY SYSTEMS. L -8 EACH BRANCH CIRCUIT SHALL CONSIST OF ONE PHASE CONDUCTOR, ONE NEUTRAL CONDUCTOR AND ONE GROUND CONDUCTOR. SIZE OF CONDUCTOR SHALL BE ##12 AWG UNLESS OTHERWISE NOTED, SINGLE PHASE HOMERUNS MAY BE COMBINED INTO THREE PHASE (A,B,C) 5 -WIRE HOMERUNS AT THE DISCRETION OF THE CONTRACTOR. L -9 REFER TO ARCHITECTURAL DRAWING FOR EXACT LENGTH OF THE LIGHTING TRACK AND QUANTITY OF LAMP HEADS FOR EACH LIGHTING TRACK. GENERAL NOTES; G -1 CAPITAL LETTERS BESIDE LIGHTING SYMBOL INDICATES FIXTURE TYPE. LOWER CASE LETTER INDICATES SWITCH LEG OR DIMMER DESIGNATION. G -2 REFER TO MECHANICAL DRAWINGS FOR DUCT SMOKE DETECTOR LOCATIONS AND QUANTITIES. OPERATION SHALL INCLUDE DUAL CONTACT BASE WITH LOCAL EQUIPMENT SHUTDOWN AND FIRE ALARM SIGNAL INITIATION. G -3 WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOMERUN, THE CONDUCTOR AND CONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT. G -4 REFER TO THE APPROPRIATE DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT INSTALLED UNDER OTHER DIVISIONS OF THE DOCUMENTS, WHICH REQUIRE ELECTRICAL SERVICE G -5 PROVIDE OUTLET BOX FITTING FOR EACH DEVICE. SIZE TO ACCOMODATE DEVICE AND CONDUCTORS. G -6 ALL CONDUITS PENETRATING ROOF SHALL BE SEALED - SEE ARCHITECTURAL DRAWINGS & DETAILS. G -7 ROOF MOUNTED MECHANICAL EQUIPMENT SHALL HAVE POWER & CONTROL RACEWAY ROUTED WITHIN EQUIPMENT ROOF CURB, G -8 DISCONNECT SWITCHES, MOTOR STARTERS AND OTHER ELECTRICAL EQUIPMENT INSTALLED ABOVE ACCESSIBLE CEILINGS, AND REQUIRING ACCESS FOR MAINTENANCE, SHALL BE INSTALLED WITH BOTTOM OF DEVICE A MAXIMUM ONE(1) FOOT ABOVE CEILING TO PROVIDE READY ACCESSIBILITY. CODE REQUIRED CLEARENCES SHALL BE MAINTAINED. G -9 MECHANICAL, PLUMBING, FIRE PROTECTION AND OTHER EQUIPMENT ARE SHOWN ON FLOOR PLAN IN APPROXIMATE LOCATION. COORDINATE WITH M, P, FP AND CONTRACT DRAWINGS /SUBMITTALS FOR EXACT LOCATION OF EQUIPMENT. G -10 GENERAL DIAGRAMMATIC RACEWAY INTERCONNECTIONS OF EQUPMENT, FIXTURES AND DEVICES ARE INDICATED ON FLOOR AND REFLECTED CEILING PLANS. REFER TO STRUCTURAL AND ARCHITECTURAL PLANS FOR ELEVATION CHANGES AND RACEWAY ROUTES. G -11 REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURES, QUANTITY SHALL BE AS INDICATED ON ELECTRICAL DRAWINGS. G -12 ALL FLUSH FLOOR MOUNTED DEVICES SHALL BE INSTALLED IN A FLUSH FLOOR OUTLET BOX WITH LEVELING SCREWS. PROVIDE DUPLEX FLIP -LID COVER FOR DUPLEX REPLACES SCREW COVERS FOR ALL OTHER DEVICES. PROVIDE BRASS CARPET FLANGES FOR ALL FLUSH FLOOR BOXES. ALL COVERS SHALL BE BRASS. G -13 ALL DEVICES IN PUBLIC AREA SHALL BE LEVITON "DECORA" TYPE WITH WHITE FINISH, G -14 IF APPLICABLE, REMOVE ALL EXISTING ELECTRICAL PANELS, CONDUITS AND LIGHTS IN EXISTING BUILDING EXCEPT AS INDICATED. G -15 ALL ELECTRICAL WORK TO BE INSTALLED IN ACCORDANCE WITH THE 2002 EDITION OF THE NATIONAL ELECTRICAL CODE ADOPTED BY THE UNIFORM CONSTRUCTION CODE - STATE OF FLORIDA AND ANY OTHER PARTY HAVING JURISDICTION. G -16 THIS SET OF DRAWINGS IS DIAGRAMMATIC IN NATURE AND INDICATES THE GENERAL ARRANGEMENT OF THE VARIOUS SYSTEMS AND APPROXIMATE LOCATIONS OF THE EQUIPMENT, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THAT THERE IS ADEQUATE SPACE AT THE LOCATIONS INDICATED FOR ALL EQUIPMENT PRIOR TO INSTALLATION OF SAME. THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL DIMENSIONS IN THE FIELD, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. G -17 ELECTRICAL CONTRACTOR SHALL SECURE SHOP DRAWINGS FROM OTHER CONTRACTORS AND VERIFY EXACT ELECTRICAL CHARACTERISTICS OF EQUIPMENT TO BE WIRED PRIOR TO ROUGH -IN. IF DISCREPANCIES ARE NOTED BETWEEN THE ELECTRICAL CONTRACT DRAWINGS AND OTHER CONTRACTOR SHOP DRAWINGS, ELECTRICAL CONTRACTOR IS TO NOTIFY ENGINEER AT ONCE. FAILURE TO PERFORM THIS DUTY WILL NOT RELIEVE THE ELECTRICAL CONTRACTOR OF THE RESPONSIBILITY TO CORRECT WIRING DEFICIENCIES` AT NO EXPENSE TO THE OWNER. G -18 SHALLTBE MADEO ADVAIILABLE GROUND-FAULT ELECTRICAL INSPECTOR TEST OF RE THE LTS ELECTRICAL PLANS EXAMINER PRIOR TO THE FINAL ELECTRICAL INSPECTION. G -19 ALL WATER COOLERS SHALL BE WALL MOUNTED WITH ELECTRICAL CONNECTIONS MADE FROM JUNCTION BOX FLUSH - MOUNTED IN WALL BEHIND COOLER HOUSING. LOCATE THE JUNCTION BOX FOR ACCESSIBILITY FROM WITHIN COOLER HOUSING. �- rJ SALTZ MICHELSON A R C H I T E C T S 3501 Griffiri Road Ft. Lauderdale, FL 33312 (954) 2662700 Fx: (954) 266 -2701 smaGsaltzmichelson. cons ?5� U U ` JJ�u UUJJ � � OOfJU�J U Udp7 JO U JJUU U U POect l4v'; ' J U000 JJ OOJJJ 2003 -160 �JUJ J O JIJ 9.,�v J awn By: Checked By: w a 12 -16 -03 PERMIT SET ��tj,tl,,lt1 h r 's1 .°0, )_k Thompson Company, Inc. 3399 Peachtree Ro" N.E. Suite 1210 TC1 #52316 Atlanta, CA 30326 404 -266 --1400 phone 404- 364 -0895 fax REVISIONS: LEGENDS & ABBREVIATIONS