Loading...
10-723-039DOORS AND FRAMES METAL DOORS 01 PROVIDE DOORS AS INDICATED AT DOOR SCHEDULE. 02 SD1 -100, TYPE III, STYLE 3, FULL FLUSH SEAMLESS, 1 -3/4" THICK, INTERNALLY REINFORCED, MANUFACTURER'S STANDARD CORE. FINISH HARDWARE 01 PROVIDE FINISH HARDWARE OF HEAVY COMMERCIAL DUTY TYPE AND AS REQUIRED. 02 PROVIDE DOOR LOCK CYLINDERS FOR DOORS, CYLINDERS SHALL BE 6 PIN KEY REMOVABLE CORE CONSTRUCTION KEYING FEATURE MASTER KEYED. (MEDECO LOCK SYSTEM) 03 KEYING - COORDINATE KEYING WITH TENANT REPRESENTATIVE. CARPENTRY PROVIDE ALL CARPENTRY WORK AS REQUIRED FOR PROPER INSTALLATION OF ALL FIXTURES AND EQUIPMENT. LUMBER MATERIALS - PROVIDE LUMBER GRADE MARKED, COMPLYING WITH AMERICAN SOFTWOOD STANDARD PS- 20 -70, SIZED S4S, SURFACE DRY WITH 19% MAXIMUM MOISTURE CONTENT. PROVIDE SOUTHERN PINE, DOUGLAS FIR -LARCH OR HEM -FIR SPECIES, STANDARD AND BETTER GRADE. ALL LUMBER SHALL BE FIRE- RETARDANT, LIMITED COMBUSTIBLE AND TREATED FIRE RETARDENT COATING ON ALL SIDES. USE "FLAM CONTROL NO. 10 -10 FLAT INTUMESCENT FIRE RETARDENT PAINT" BY FLAME CONTROL COATINGS, INC. (716) 2S2 -1399 SURFACE PREPARATION: SURFACE PREPARATION SHOULD BE CARRIED OUT ACCORDING TO GOOD PAINTING PRACTICES. ALL DIRT, GREASE, OIL, WAX, RUST, AND OTHER FOREIGN MATTER MUST BE REMOVED. NEW WOOD, FIBERBOARD, AND OTHER SURFACES HAVING UNEVEN OR EXCESSIVE POROSITY SHOULD BE SEALED WITH FLAME CONTROL NO. 3001 ALKYD PRIMER, AND ALLOWED TO DRY A MINIMUM OF 16 HOURS BEFORE APPLYING NO. 10 --10. APPLICATION: FLAME CONTROL NO. 10 -10 IS READY TO USE. IT CAN BE APPLIED BY BRUSH, ROLLER, AIRLESS OR CONVENTIONAL HEAVY DUTY SPRAY EQUIPMENT. STIR THOROUGHLY AND APPLY, USING A FULL BODIED COAT. IF THINNING IS REQUIRED, USE ONLY MINERAL SPIRITS. DO NOT APPLY IN TEMPERATURES BELOW 5OF (10C) SUGGESTED COVERAGE RATE: 190 TO 250 SQ.FT. /US. GALLON (4.7 TO 6.1 M2 /L) IN ONE OR TWO COATS. SEE FIRE HAZARD CLASSIFICATION FOR SPECIFIC COVERAGE. DRIES TO TOUCH IN APPROXIMATELY 4 HOURS. ALLOW AT LEAST 24 HOURS DRYING TIME BEFORE OVERCOATING. FOR THINNING AND CLEANING EQUIPMENT, USE MINERAL SPIRITS. TINTING: AVAILABLE IN WHITE, OFF WHITE, AND PASTEL SHADES, OR MAY BE FIELD TINTED WITH OIL TINTING COLORANTS. TINTING COLORATNS SHOULD NOT EXCEED 2 FLUID OUNCES PER GALLON. PACKAGING: STANDARD PACKAGING, 1 GALLON, 5 GALLON, AND 55 GALLON CONTAINERS. CAUTION COMBUSTIBLE. THE LIQUID COATING CONTAINS PETROLEUM DISTILLATES, DUDE CARE MUST BE EXERCISED DURING AND AFTER APPLICATION UNTIL THE COATING IS DRY. KEEP AWAY FROM HEAT, SPARKS, AND FLAME. AVOID CONTACT WITH SKIN. AVOID BREATHING VAPORS OR SPRAY MIST. OPEN WINDOWS AND DOORS OR USE OTHER MEANS TO ENSURE FRESH AIR ENTRY DURING APPLICATION AND DRYING. IF YOU EXPERIENCE EYE WATERING, HEADACHES OR DIZZINESS, INCREASE FRESH AIR OR WEAR RESPIRATORY PROTECTION (NIOSH /MSHA TC 23C OR EQUIVALENT) OR LEAVE THE AREA. DO NOT TAKE INTERNALLY. CLOSE CONTAINER AFTER EACH USE. USE WITH ADEQUATE VENTILATION. NOTICE: REPORTS HAVE ASSOCIATED REPEATED AND PROLONGED OCCUPATIONAL OVER -- EXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND INHALING THE CONTENTS MAY BE HARMFUL OR FATAL. CONSULT THE MATERIAL SAFETY DATA SHEET FOR THIS PRODUCT, PRIOR TO OPENING CONTAINER. PROVIDE COUNTER OF THE DIMENSIONS SHOWN IN DRAWINGS. ` INTERIOR WOOD TRIMMING AND MOULDING PROVIDE MOULDING AND TRIMS AS SHOWN ON DRAWINGS. 01 WOOD SPECIES AS SPECIFIED ON DETAILS. 02 MOULDINGS AND TRIM AVAILABLE AT: R.H. is SONS WOOD PRODUCTS 5150 N.W. 37 AVENUE MIAMI, FL 33142 (305) 634 -7935 CHARLIE HERNANDEZ CABINETRY "O1 ALL MILLWORK SHOWN SHALL BE CONSTRUCTED OF FIRE RETARDANT HARDWOOD AND PLYWOOD WITH VENEER CORE, 3/4" MINIMUM THICKNESS UNLESS NOTED OTHERWIDE. (FIRE RETARDANT, LIMITED COMBUSTIBLE) 02 ALL INTERIOR SURFACES TO RECEIVE PLASTIC LAMINATE. 03 ALL MILWORK CONSTRUCTION TO COMPLY WITH AWI REQUIREMENTS FOR "CUSTOM" GRADE. REVEAL OVERLY CONSTRUCTION. 04 ALL EXPOSED HARDWARE TO BE BRASS ALUMINUM FINISH. STANLEY OR EQUAL. 05 VOID 06 ALL CABINET DOORS SHALL HAVE EXPOSED HINGES, COORDINATE WITH TENANT. 07 OVERHEAD CABINETS SHALL BE SECURED TO WALL BLOCKING AND STRUCTURE ABOVE WITH 1/4" TREADED RODS, PROVIDE ADEQUATE REINFORCEMENT AT CABINET WALLS AT SUPPORT POINTS. GYPSUM DRYWALL PANELS - TAPERED EDGE, 4S" WIDE IN LENGHTS WHILE AVAILABLE TO MINIMIZE JOINTS AND THICKNESS, AS INDICATED. 01 SCREW TYPE STEEL STUDS -- ASTM C 645 GALVANIZED STEEL, 26 GAUGE 3 -5 /8 EXCEPT AS NOTED OTHERWISE. 02 PROVIDE RUNNER CHANNELS, FURRING CHANNELS, FURRING AND ACCESSORIES AS REQUIRED FOR COMPLETE CEILING AND PARTITION METAL SYSTEM. 03 INSTALL J MOLDINGS ALONG ALL THE EXPOSED EDGES OF SHEETROCK INCLUDING THE EDGES FACING OR NEXT TO CEILING. ACCESSORIES 01 FASTENERS - SCREWS, MANUFACTURER'S RECOMMENDED TYPE AND LENGTH FOR APPLICATION INTENDED. 02 TRIM - "DURA --A- BEAD" CORNER BEAD, NO. 200A, 2006, 200C METAL TRIMS. 03 JOINT TREATMENT - PERF -A -TAPE SYSTEM WITH MANUFACTURER'S RECOMMENDED JOINT AND TAPING COMPOUNDS TO PROVIDE SMOOTH SANDED FINISH READY FOR PAINT. 04 PROVIDE J MOLDING ALONG ALL THE EXPOSDED EDGES OF SHEETROCK INCLUDING THE EDGE FACING OR ALONG THE CEILING. INSTALL METAL SUPPORT AND DRYWALL SYSTEM IN ACCORDANCE WITH U.S. GYPSUM BULLETINS SA 923 AND SA 927. CURRENT EDITION. IN ALL AREAS THAT ARE TO RECEIVE A SUSPENDED CEILING, THE SURFACES ARE TO BE OF FINISHED DRYWALL. FINISH IS TO BE PER THE PAINT SCHEDULE SHOWN ON THE DRAWINGS. 1 N.T.S. PAINTS AND COATINGS PART I GENERAL: 1.01 SECTION INCLUDES. A. SURFACE PREPARATION. B. FIELD APPLICATION OF PAINTS, STAINS, VARNISHES, AND OTHER COATINGS. 1.02 QUALITY ASSURANCE A. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN PERFORMING THE WORK OF THIS SECTION WITH MINIMUM THREE YEARS EXPERIENCE. 1.03 ENVIRONMENTAL REQUIREMENTS A. DO NOT APPLY MATERIALS WHEN SURFACE AND AMBIENT TEMPERATURES ARE OUTSIDE THE TEMPERATURE RANGES REQUIRED BY THE PAINT PRODUCT MANFUACTURER B. PROVIDE LIGHTING LEVEL OF SOFT. CANDLES MEASURED MID - HEIGHT AT SUBSTRATE SURFACE. 1.04 EXTRA MATERIALS A. SUPPLY 1 GALLON OF EACH COLOR; STORE WHERE DIRECTED. B. LABEL EACH CONTAINER WITH COLOR IN ADDITION TO THE MANUFACTURER'S LABEL. PART II PRODUCTS: 2.01 MANUFACTURERS A. PAINTS: 1. BEJAMIN MOORE k CO: WWW.BENJAMINMOORE.COM 2.02 PAINTS AND COATINGS - GENERAL A. PAINTS AND COATINGS: READY MIXED, EXCEPT FIELD - CATALYZED COATINGS. PREPARE PIGMENTS: 1, TO A SOFT PASTE CONSISTENCY, CAPABLE OF BEING READILY AND UNIFORMLY DISPERSED TO A HOMOGENEOUS COATING. 2. FOR GOOD FLOW AND BRUSHING PROPERTIES. 3. CAPABLE OF DRYING OR CURING GREE OF STREAKS OR SAGS. 2.03 PAINT SYSTEMS - EXTERIOR A. PRESSURE TREATED WOOD, LATEX, 3 COAT: 1. ONE COAT OF LATEX PRIMER SEALER. 2. FLAT: TWO COATS OF LATEX ENAMEL. B. WOOD AND FIBER CEMENT SIDING, OPAQUE, LATEX, 3 COAT: 1. ONE COAT OF LATEX PRIMER SEALER. 2. FLAT: TWO COATS OF LATEX ENAMEL. C. NOT USED. D. CONCRETE /MASONRY, OPAQUE, ALKYD, 3 COAT: 1. ONE COAT OF BLOCK FILLER. 2. FLAT: TWO COATS OF ALKYD ENAMEL. E. PAINT ME- -OP -3A - FERROUS METALS, UNPRIMED, ALKYD, 3 COAT: 1. ONE COAT OF ALKYD PRIMER. 2. SEMI - GLOSS: TWO COATS OF ALKYD ENAMEL, F. PAINT MGE -OP-3A - GALVANIZED METALS, ALKYD, 3 COAT: 1. ONE COAT GALVANIZE PRIMER. 2. SEMI - GLOSS: TWO COATS OF LATEX ENAMEL. 2.04 PAINT SYSTEMS - INTERIOR A. WOOD, OPAQUE, LATEX, 3 COAT: 1. ONE COAT OF LATEX PRIMER SEALER. 2. SEMI - GLOSS, TWO COATS OF ALKYD ENAMEL. B. WOOD, TRANSPARENT, VARNISH, STAIN: 1. FILLER COAT (FOR OPEN GRAINED WOOD ONLY) 2. ONE COAT OF STAIN. 3. ONE COAT SEALER 4. SATIN: TWO COATS OF VARNISH. C. CONCRETE /MASONRY, OPAQUE, LATEX, 3 COAT: 1. ONE COAT OF BLOCK FILLER. 2. FLAT: TWO COATS OF LATEX ENAMEL. D. FERROUS METALS, UNPRIMED, ALKYD, 3 COAT: 1. ONE COAT OF ALKYD PRIMER 2. SEMI - GLOSS: TWO COATS OF ALKYD ENAMEL, LOW LUSTER. E. GYPSUM BOARD /PLASTER, LATEX- ACRYLIC, 3 COAT: 1. ONE COAT OF ALKYD PRIMER SEALER. 2. FLAT: TWO COATS OF LATEX ENAMEL - ACRYLIC. PART III EXECUTION: 3.01 EXAMINATION A. VERIFY THAT SURFACES ARE READY TO RECEIVE WORK AS INSTRUCTED BY THE PRODUCT MANUFACTURER. B. MEASURE MOISTURE CONTENT OF SURFACES USING AN ELECTRONIC MOISTURE METER. DO NOT APPLY FINISHES UNLESS MOISTURE CONTENT OF SURFACES ARE BELOW THE FOLLOWING MAXIMUMS. 1. PIASTER AND GYPSUM WALLBOARD: 12 PERCENT 2. MASONRY, CONCRETE, AND CONCRETE UNIT MASONRY: 12 PERCENT. 3. INTERIOR WOOD, 15 PERCENT, MEASURED IN ACCORDANCE WITH ASTM D 4442, 4. EXTERIOR WOOD, 15 PERCENT, MEASURED IN ACCORDANCE WITH ASTM D 4442. 5. CONCRETE FLOORS, S PERCENT. 3.02 PREPARATION A. SURFACE APPURTENANCES: REMOVE OR MASK ELECTRICAL PLATES, HARDWARE, LIGHT FIXTURE TRIM, ESCUTCHEONS, AND FITTINGS PRIOR TO PREPARING SURFACES OR FINISHING. B. SURFACES: CORRECT DEFECTS AND CLEAN SURFACES WHICH AFFECT WORK OF THIS SECTION. REMOVE OR REPAIR EXISTING COATINGS THAT EXHIBIT SURFACE DEFECTS. C. MARKS: SEAL WITH SHELL AC THOSE WHICH MAY BLEED THROUGH SURFACE FINISHES. D. IMPERVIOUS SURFACES: REMOVE MILDEW BY SCRUBBING WITH SOLUTION OF TETRA - SODIUM PHOSPHATE AND BLEACH. RINSE WITH CLEAN WATER AND ALLOW SURFACE TO DRY. E. CONCRETE AND UNIT MASONRY SURFACES TO BE PAINTED: REMOVE DIRT, LOOSE MORTAR, SCALE, SALT OR ALKALI POWDER, AND OTHER FOREIGN MATTER. REMOVE OIL AND GREASE WITH A SOLUTION OF TRI- SODIUM PHOSPHATE; RINSE WELL AND ALLOW TO DRY. REMOVE STAINS CAUSED BY WEATHERING OR CORRODING METALS WITH A SOLUTION OF SODIUM METASILICATE AFTER THROUGHLY WETTING WITH WATER. ALLOW TO DRY. F. GYPSUM BOARD SURFACES TO BE PAINTED: FILL MINOR DEFECTS WITH FILLER COMPOUND. SPOT PRIME DEFECTS AFTER REPAIR. G. CONCRETE FLOORS TO BE PAINTED: REMOVE CONTAMINATION, ACID ETCH, AND RINSE FLOORS WITH CLEAR WATER. VERYIFY REQUIRED ACID - ALKALI BALANCE IS ACHIEVED. ALLOW TO DRY. H. GALVANIZED SURFACES TO BE PAINTED: REMOVE SURFACE CONTAMINATION AND OILS AND WASH WITH SOLVENT. APPLY COAT OF ETCHING PRIMER. I. UNCOATED STEEL AND IRON SURFACES TO BE PAINTED. REMOVE GREASE, MILL SCALE, WELD SPLATTER, DIRT, AND RUST. WHERE HEAVY COATINGS OF SCALE ARE EVIDENT, REMOVE BY HAND WIRE BRUSHING OR SANDBLASTING; CLEAN BY WASHING WITH SOLVENT. APPLY A TREATMENT OF WEATHERING OF CORRODING METALS WITH A SOLUTION OF SODIUM METASILICATE AFTER THOROUGHLY WETTING WITH WATER. ALLOW TO DRY J. INTERIOR WOOD ITEMS TO RECEIVE TRANSPARENT FINISH: WIPE OFF DUST AND GRIT PRIOR TO SEALING, SEAL KNOTS, PITCH STREAKS, AND SAPPY SECTIONS WITH SEALER. FILL NAIL HOLES AND CRACKS AFTER SEALER HAS DRIED, AND LIGHTLY BETWEEN COATS. PRIME CONCEALED SURFACES WITH GLOSS VARNISH REDUCED 25 PERCENT WITH THINNER, K. EXTERIOR WOOD TO RECEIVE OPAQUE FINISH: REMOVE DUST, GRIT, AND FOREIGN MATTER. SEAK KNOTS, PITCH STREAKS, AND SAPPY SECTIONS. FILL NAIL HOLES WITH TINTED EXTERIOR CALKING COMPOUND AFTER PRIME COAT HAS BEEN APPLIED. BACK PRIME CONCEALED SURFACES BEFORE INSTALLATION. L. EXTERIOR WOOD TO RECEIVE TRANSPARENT FINISH: REMOVE DUST, GRIT, AND FOREIGN MATTER; SEAL KNOTS, PITCH STREAKS, AND SAPPY SECTIONS WITH SEALER. FILL NAIL HOLES WITH TINTED EXTERIOR CALKING COMPOUND AFTER SEALER HAS BEEN APPLIED. PRIME CONCEALED SURFACES. M. WOOD DOORS TO BE FIELD - FINISHED: SEAL WOOD DOOR TOP AND BOTTOM EDGE SURFACES WITH CLEAR SEALER. N. METAL DOORS TO BE PAINTED: PRIME METAL DOOR TOP AND BOTTOM EDGE SURFACES. 3.03 APPLICATION A. APPLY PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. DO NOT APPLY FINISHES TO SURFACES THAT ARE NOT DRY. ALLOW APPLIED COATS TO DRY BEFORE NEXT COAT IS APPLIED. C. APPLY EACH COAT TO UNIFORM APPEARANCE. APPLY EACH COAT OF PAINT SLIGHTLY DARKER THAN PRECEDING COAT UNLESS OTHERWISE APPROVED. D. SAND WOOD SURFACES LIGHTLY BETWEEN COATS TO ACHIEVE REQUIRED FINISH. E. VACUUM CLEAN SURFACES OR LOOSE PARTICLES. USE TACK CLOTH TO REMOVE DUST AND PARTICLES JUST PRIOR TO APPLYING NEXT COAT. 3.04 FINISHING MECHANICAL AND ELECTRICAL EQUIPMENT A. REMOVE UNFINISHED LOUVERS, GRILLES, COVERS, AND ACCESS PANELS ON MECHANICAL AND ELECTRICAL COMPONENTS AND PAINT SPERATELY. B. REINSTALL ELECTRICAL COVER PLATES, HARDWARE, LIGHT FIXTURE TRIM, ESCUTCHEONS, AND FITTINGS REMOVED PRIOR TO FINISHING. 3.05 SCHEDULE - SURFACES TO BE FINISHED A. DO NOT PAINT OF FINISH THE FOLLOWING ITEMS: 1. ITEMS FULLY FACTORY- FINISHED UNLESS SPECIFICALLY NOTED. 2. FIRE RATING LABELS, EQUIPMENT SERIAL NUMBER AND CAPACITY LABELS. B. PAINT THE SURFACES DESCRIBED BELOW UNDER SCHEDULE - PAINT SYSTEMS. C. MECHANICAL AND ELECTRICAL, USE PAINT SYSTEMS DEFINED FOR THE SUBSTRATES TO BE FINISHED. 1. PAINT ALL INSULATED AND EXPOSED PIPES, CONDUIT, BOXES, INSULATED AND EXPOSED DUCTS, AND HANGERS, BRACKETS, COLLARS AND SUPPORTS OCCURRING IN FINISHED AREAS, UNLESS OTHERWISE INDICATED. 2. PAINT ALL EXPOSED HVAC DIFFUSERS TO MATCH ADJACENT MATERIALS. 3. PAINT SHOP- PRIMED ITEMS OCCURRING IN FINISHED AREAS. 4. PAINT INTERIOR SURFACES OF AIR DUCTS AND CONVECTOR AND BASEBOARD HEATING CABINETS THAT ARE VISIBLE THROUGH GRILLES AND LOUVERS WITH ONE COAT OF FLAT BLACK PAINT TO VISIBLE SURFACES. 5. PAINT DAMPERS EXPOSED BEHIND LOUVERS, GRILLES, TO MATCH FACE PANELS, SUSPENDED ACOUSTICAL CEILING PART I GENERAL: 1.01 SECTION INCLUDES A. SUSPENDED METAL GRID CEILING SYSTEM. B. ACOUSTICAL UNITS. 1.02 SECTION INCLUDES A. PROVIDE 5 PERCENT OF TOTAL ACOUSTICAL UNIT AREA OF EACH TYPE OF ACOUSTICAL UNIT FOR SMOKEY BONES'S USE IN MAINTENANCE OF PROJECT. PART II PRODUCTS: 2.01 ACOUSTICAL UNITS A. MANUFACTURERS: 1. USG CORPORATION: WWW.USG.COM B. ACOUSTICAL UNITS - GENERAL: ASTM E 1264, CLASS A. 2.02 SUPSENSION SYSTEM(S) A. MANUFACTURERS: 1. SAME AS FOR ACOUSTICAL UNITS. B. SUSPENSION SYSTEMS - GENERAL: ASTM C 635, DIE CUT AND INTERLOCKING COMPONENTS, WITH STABILIZER BARS, CLIPS, SPLICERS., PERIMETER MOULDINGS, AND HOLD DOWN CLIPS AS REQUIRED. 2.03 ACCESSORIES A. SUPPORT CHANNELS AND HANGERS: GALVANIZED STEEL; SIZE AND TYPE TO SUIT APPLICATION, SEISMIC REQUIREMENTS, AND CEILING SYSTEM FLATNESS REQUIREMENT SPECIFIED. B. PERIMETER MOULDINGS: SAME MATERIAL AND FINISH AS GRID. PART III PRODUCTS: 3.01 INSTALLATION - SUSPENSION SYSTEM A. INSTALL SUSPENSION SYSTEM IN ACCORDANCE WITH ASTM C 636, ASTM E 550, AND MANUFACTURER'S INSTRUCTIONS AND AS SUPPLEMENTED IN THIS SECTION. B. RIGIDLY SECURE SYSTEM, INCLUDING INTEGRAL MECHANICAL AND ELECTRICAL COMPONENTS, FOR MAXIMUM DEFLECTION OF 1:360. C. INSTALL AFTER MAJOR ABOVE- CEILING WORK IS COMPLETE. COORDINATE THE LOCATION OF HANGERS WITH OTHER WORK. D. HANG SUSPENSION SYSTEM INDEPENDENT OF WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT. WHERE CARRYING MEMBERS ARE SPLICED, AVOID VISIBLE DISPLACEMENT OF FACE PLANE OF ADJACENT MEMBERS. E. WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR SPACING OF HANGERS, REINFORCE THE NEAREST AFFECTED HANGERS AND RELATED CARRYING CHANNELS TO SPAN THE EXTRA DISTANCE. F. DO NOT SUPPORT COMPONENTS ON MAIN RUNNERS OR CROSS RUNNERS IF WEIGHT CAUSES TOTAL DEAD LOAD TO EXCEED DEFLECTION CAPABILITY. G. SUPPORT FIXTURE LOADS USING SUPPLEMENTARY HANGERS LOCATED WITHIN 6 INCHES OF EACH CORNER, OR SUPPORT COMPONENTS INDEPENDENTLY. H. DO NOT ECCENTRICALLY LOAD SYSTEM OR INDUCE ROTATION OF RUNNERS. I. PERIMETER MOULDING: INSTALL AT INTERSECTION OF CEILING AND VERTICAL SURFACES AND AT JUNCTIONS WITH OTHER INTERRUPTIONS. 1. USE LONGEST PRACTICAL LENTHS. 2. OVERLAP AND RIVET CORNERS. 3.02 INSTALLATION - ACOUSTICAL UNITS. A. INSTALL ACOUSTICAL UNITS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. FIT ACOUSTICAL UNITS IN PLACE, FREE FROM DAMAGED EDGES OR OTHER DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION. C. FIT BORDER TRIM NEATLY AGAINST ABUTTING SURFACES. D. INSTALL UNITS AFTER ABOVE- CEILING WORK IS COMPLETE. E. INSTALL ACOUSTICAL UNITS LEVEL, IN UNIFORM PLANE, AND FREE FROM TWIST, WARP, AND DENTS. F. CUTTING ACOUSTICAL UNITS. 1. MAKE FIELD CUT EDGES OF SAME PROFILE AS FACTORY EDGES. 3.03 ERECTION TOLERANCES. A. MAXIMUM VARIATION FROM FLAT AND LEVEL SURFACE: 1/8 INCH IN 10 FEET. B. MAXIMUM VARIATION FROM PLUMB OF GRID MEMBERS CAUSED BY ECCENTRIC LOADS: 2 DEGREES. 2 1 PARTITION N.T.S. DRYWALL CORNER BEAD .5 10' GYPSUM WALL BOARD n TARE AND JOINT COMPOUND METAL STUDS 3 5 /B" 5" K) 90 CORNER UM tD Z n °) n BOUND DS 0 17 CORNER DETAIL F.,. Uu NLR •LAU GYPSUM WALL BOARD L STUDS • 16" O.C. 3 5 /4' 5- ® PARTITION END DETAIL CORNER 25 GA. META GUSSET P�ATfS 1 -0 LONG SPACED 3 -D D.C. PANE AND JOINT COMPOUND 5 /9" GYPSUM WALL BOARD METAL STUBS • 16" R.C. s5/2 5 45� CORNER DETAIL 5/B 3" YPSUM WALL BOARD AL STUDS AT 16' O.C. WALL BASE SEE FINISH LE FOR TYPE RUNNER ATTACHED WITH POWER DRIVEN FASTENERS (HILTI OR EQUAL) • 16' O.G. © BASE DETAIL V HANGER WIRE AT ok O.C. AND WITHIN i' OF ENDS SNAP ON STIFFENERS AS REQUIRED 1 1/�" GOLD ROLLED CHANNELS Aj 4 -0 O.C. MAX. AND WITHIN R OF ENDS. MAINTAIN 1' CLEAR AT WALLS METAL FURRING AT 24. O.C. MAX. AND WITHIN t OF WALL C14P TO CHANNELS AND MAINTAIN 1 CLEARANCE FROM WALLS 5 /8" MINIMUM GYPSUM WALL BOARD 'U' CHANNEL TRIM USG /200 A WALL OR BACK OF EXTERIOR WALL O GYPSUM WALL BOARD CEILING DETAILS �WW � WWWWW W YV VV VV VY 4V V VV VU YYY YUY V V W •VV• V v Y V V V U Y U U r • U Y U • Y r Y V V W V V W U W U U V V U Y • • YYU u uVU • •rr• •r Y•• ••• •Cr• Y • • Y Y Y W Y Y r r••• r •yrY. • •vW Y v••Y r +C:11 "Y Or SOUTH V!Ar;iI BUILD[t, "G DEPT. "4''TR'UCTUrZA' ECTiON �i N � 00 Q N M .--I pl a vi f N 0 architect NORBERTO ROSENSTEIN ARCHITECT INC. , ANCHTECTURE - NTEFlIOPI DESIGN - PLANING 126 S. FEDERAL HIGHWAY SUITE If 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922.7388 EMAIL :infoorosensteinarchitect.com WEB: www.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYRIGHT © 2009 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM WITHOUT PERMISSION. DESIGNED �%I DRAWN A CHECKED'���f,��/ N. R. W,,, I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. elton + leniz A R Q U I T E C T 0 S A S 0 C I A D 0 S RUT :76.575.840 -8 AURELIO GONZALEZ A ;30 VITACURA r Qi 8-11 -2010 REVISION A 8-11 -2010 FIRE DEPT COMMENTS R E V I S 1 0 N S COMM. DATE 2010 -31 8 -5 -2010 ■ Casa mi seer. 5701 SUNSET DR. SUITE B -10 SOUTH MIAMI FLORIDA, 33143 NOTES / DETAILS A -11 19 �i N � 00 Q N M .--I pl a vi f N 0