Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-723-021
'- ' - RELOCATED STAINLESS \4F FIN. SOFFIT STEEL RODS. ATTACH TO CEILING ABOVE, !`�• Q' _F F Fk F F Fk F F Fk DISPLAY .. :. r PROVIDE BACKING AS 3 109 �._,• �,- REQUIRED. RELOCATED STAINLESS RELOCATED STAINLESS STEEL RODS. ATTACH STEEL RODS. ATTACH C~ n TO CEILING ABOVE, TO CEILING ABOVE, k F k k . k. PROVIDE BACKING AS 3 F PROVIDE BACKING AS FF F5 k REQUIRED. �- F .F. , REQUIRED. F `.. ....... ....... 3 F2 F2 F2 F2 3. 3 3. .... F.k' FIN. F' ff I� RELOCATED STAINLESS F3 . . . . .. . .. STEEL RODS. ATTACH I . . _ . . \ TO CEILING ABOVE, F2 PROVIDE BACKING AS F2 F2 F2. F2 F2 FP \. F REQUIRED. F2 w. m RELOCATED STAINLESS STEEL RODS. ATTACH TO CEILING ABOVE, PROVIDE BACKING AS REQUIRED. ...... . . . i I�FX F2 F2 F2 2 F2 F2 F2 • • • aL ...... F ... F N, OFFIT GI-2 F2 F2 F F2 F.3 F3 F F3 F3 F2 F3 w - • ..' .:4:1. ': F.'...::: `: F OPEN TO ABOVE :.. F2. F1A, • OPEN D K F2 F2 >"2 F2 F2 F2 ®X :F1k ::Fti..� �:' NEW MTL CANOPY ESP ® 4•- .• ::::::.:::. BLACK ALUCOBOND rt • SW 6258 SEE SHEET T 1 /A -16.3 F2 F2 F2 F2 F2 .7 ...• :::..::::.:.:..:. F3 F3 F3 F3 F F3 F3 3 3 : ' Ftik: ... N, / F2 OPEN TO ABOVE 2 F2 F2 F2 F2 ......... SALES F3 101 ';:: 3 ........ . FZ 2 e FZ /i ...t�.k RELOCATED STAINLESS FX STEEL RODS. ATTACH ® k TO CEILING ABOVE, E-B FZ F2 F2 F2 F2 F PROVIDE BACKING AS REQUIRED. F F3 F2 F2 . . . . . . . FIN, SOFT T F2 2 . / F2 F•3 F4 10' -G' A.F.F. 3 FZ . . . . . lOTTOM OF GRID F3 FZ OP N < FZ H U F2 �� . . . 11' -0' k FZ 102 F2 F2 0 F I F I - F � 2 STORAGE ', „�•� F3 104 F3 k ; FZ 3 Fk F3 FZ Al STAI 110 F b FX �5 �h 2 o �' EX j © F;k EX 2 F� ELEV ® , FZ /� FX 0 F� � EX 15'-9' tik FZ 3 j FC, OPEN DECK f / E2 SHIPPING 2 F ' • p 2 RELOCATED STAINLESq STEEL RODS. ATTAC TO CEILING ABOVE, PROVIDE BACKING AS REQUIRED, w STAIR STORAGE 103 WOMEN REST 105 .� MEN REST 106 r I/ _.,• (.r�^t E�1.�t1•«�� }:fit, �L�S { t , C-f JON '� -t��, � to ..� �►.� t:t Yi4� �!•"il�i'r,Ri �F'r�i!xa�G' ri ". w fil ••��v �"^A4�f.'I� Sir:......._.. -.. t�"'..��. s~� °,,�'?, ".•':� i r/ C7c•��*�- V' ATEfR fN F_ ` E. 'T',E" j0N I DA-177440 REFLECTED CEILING NOTES 1.) RE: MECH. FOR EXACT NUMBER, TYPE AND LOCATION OF SUPPLY, RETURN AND EXHAUST FIXTURES. 2.) RE: ELECT. FOR EXACT NUMBER, TYPE AND LOCATION OF OUTLETS. 3.) CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS. ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS AS INDICATED ON THE ARCHITECTURAL DRAWINGS. 4.) PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO PARTITION SURFACES, FREE FROM CURVES, BREAKS, OR OTHER IRREGULARITIES 5.) LIGHT FIXTURES, EXIT SIGNS AND OTHER CEILING ELEMENTS SHALL BE LOCATED IN CENTER OF INDIVIDUAL CEILING TILE U.O.N. OR AS DIRECTED BY ARCHITECT. G.) PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE VERIFY MANUFACTURER RECOMMENDATIONS. 7.) THE REFLECTED CEILING PLAN INDICATES THE LOCATION OF CEILING TYPES, CEILING FIXTURES, FAN MOTORS, AND ASSOCIATED ITEMS. REFER TO ENGINEERING DRAWINGS (LIGHTING PLAN) FOR CIRCUITING, WIRING LAY -OUT, AND ADDITIONAL INFORMATION. a.) ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE CEILING ELEMENTS ARE TO DE FOUND IN THE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS, BY THE DESIGN ENGINEERS. 9.) CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICTS CEILING FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC., PRIOR TO INSTALLATION. NEW PLUMSBING, MECHANICAAL FANS, DUCTS, CONDUITS, AND OTHER RELATED ITEMS SO AS TO NOT CONFLICT WITH LIGHTS AND ANY UNIQUE FIELD CONDITIONS. 10.) FURNISH AND INSTALL UNDERWRITERS LABORATORY, INC. (U.L.) LABELLED DEVICES THROUGHOUT. 11.) PROVIDE AND INSTALL EMERGENCY LIGHTING PER ADA /TITLE 24 REQUIREMENTS. 12.) ELECTRICAL CONTRACTOR TO PROVIDE ALL SWITCHES, DIMMERS, & PLATES, AS REQUIRED BY DESIGN, LOCATED 44" A.F.F. 6" FROM DOOR FRAME, U.O.N. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GANGED TOGETHER, AND FURNISHED WITH ONE COVER PLATE. 13.) N.L REFERS TO NIGHT LIGHT. DINING AREA SHOULD HAVE AT LEAST TWO LIGHTS THAT OPERATE THROUGH THE EVENING HOURS FOR SAFETY. 14.) ELECTRICAL CONTRACTOR TO LOCATE ALL TRANSFORMERS AT BAR ABOVE CEILING. LOCATION TO BE COORDINATED W/ G.C. 15.) CLEAN, REBALAST, RELAMP, REPLACE BROEK LENSES & ACRYLIC COVERS AT ALL EXISTING LIGHT FIXTURES TO REMAIN 16.) CEILINGS k DUCKS ON EXPOSED AREAS PAINT AND REPAIR AS NEEDED 17.) PAINT UPPER AREAS OF NEW DRYWALL WALLS MATCHING EXISTING 18.) EXTEND NEW ROUND DROPPED CEILING BOTTOM UNDER CONCRETE BEAM AT SECOND FLOOR 19.) ALL EXPOSED NEW AND EXISTING H.V.A.C. DUCT WORK, CONDUITS AND ANY ELEMENTS ATTACHED TO THE CLNG. TO BE PAINTED BLACK. 2 ALL EMERGENCY LIGHTS AND EXIT SIGNS TO BE BLACK FINISH. 21.) COORDINATE EXIT SIGNS LOCATION WITH SHEETS A -2.1 AND A -2.2. 3 21iNUIL�:) N.T.S. REFLECTED CEILING SCHEDULE 2x4 CEILING TILE (ACT -1 /ACT -2) Y Y V architect S FINISH SCHEDULE ON SHEE A -7.3. ARCHITECT INC. SEE DETAIL AT 4/A -4.1 ARCHITECTURE - IMERM DEU - M AI�""� W CALEIDOSCOPE GRID AT 10' -6" A.F.F.; SUITE $ 202 03 -000 COLOR RAL 2040 .:.:.....:.' ...:.......... DRYWALL CEILING. SEE DETAIL 5/A -4.1 ' • ' • • • • • ' • • ' SEE FINISH SCHEDULE ON SHEET A -7.3 CONCRETE DECK HEIGHT @ 15' -9" A.F.F. N.T.S. NOTE: PROVIDE MAIN RUNNERS CONTINUOUS IN LINE WITH EACH SIDE OF RECESSED LIGHT AND PARALEL MAXIMUM 4' -0" ON CENTERS IN THE CEILING FIELD. CROSS RUNNERS SHALL BE MAXIMUM 2' -0" ON CENTERS. PROVIDE ACCESSIBLE HOLD -DOWN CLIPS FOR ACOUSTIC TILES MORE THAAN 1 LS. /SQ.FT. PROVIDE MINIMUM 12 GAAUGE GALVANIZED STEEL HANGER WIRE MAXIMUM 4' -O" ON CENTERS ALONG MAAIN RUNNERS. 41 1 Yr. � N.T.S. t�� 9S G& HANGER R N 8?UCIR. S A R ION VAT IFFENERS 1 1,2" COLD ROLLED CHANNELS AT ' -0 O.C. MAX. AND „W01NR 6 OF ENDS, MAINTAIN 1 AT WALLS ,A N ;o' k4l TAIbTALLS O "P M I 5 /8° MINIMUM GYPSUM WALL BOARD 'U' CHANNEL TRIM USG #200 A WALL OR BACK OF EXTERIOR WALL FIRST FLOOR RCP 5 TYP. GYPSUM BOARD DETAILS 1/8„ = 1 -0 N.T.S. W v W u 4 V Y • u U V .+ V V u � • VWVV L ♦ V y Y Y V architect NORBERTO ROSENSTEIN ARCHITECT INC. , ARCHITECTURE - IMERM DEU - M AI�""� W 126 S. FEDERAL_ HIGHWAY SUITE $ 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX; (954) 922 -7388 EMAIL :info ,orosensteinarchitect.com WEB: www.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYRIGHT @ 2009 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM WITHOUT PERMISSION. N r !'�n�� DESIGNED :, DRAWN % 'G rf o / % � � % S.S. A/ i i CHECKED N. R. I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. ■ elton 6 n 17 A R Q U I T E C T 0 S ��P.o C I A S RUT :76.575.840-4C.) ' ` =fit AURELIO GONZ/�►1.;E 3330, 7 VITACURA `;,,_ , .-, `r'3 a. • F 0 8 -26-2010 REVISION Q S -19 -2010 REVISION Qt 8 -11 -2010 REVISION QA 8 -11 -2010 FIRE DEPT COMMENTS R E V I S 1 0 N S COMM. DATE 2010 -31 8 -5 -2010 Casaidteas. 5701 SUNSET DR. SUITE B -10 SOUTH MIAMI FLORIDA, 33143 FIRST FLOOR RCP A -4.1 19 0) L O LL FE CL L� r-I Y Q C7 C) cJ') 0 fT H V) U M �O 1p �© Q.� .Q L �O L "-J a E U a fu �ir>tl rH J T