Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-723-013
I� .••.1. -1 ICI:'• �I- 1�I —I ❖.• �'•..I_ -- VISI JAI 1 •• •Y • ON • i k' 1 � 1 zs I ' ■ 1 O WOM E RUST 20 i 0 I 0 LE H .' � I 25 5 --0 ' 0 0 Fo� O O O O 0 \ FE "R" 32'-7 in C)()F MEN RES 204 _ - -- ' � TECH OI - - \ —''�— COMMON PATH _ 15 Ass I TECH UTILITY °o AL 201 Mississippi LOCKERS \ FE,R., C \ is is \ \ \ 23 \ .. ©� Is— ON Fe 02 "!�• `' ' o �'g �� �• ,`o� �1 CONFERENCE AIR 82' it EL V / 21 \ u a /OFFICE FE "R. / 209 212 10 CORR / 21 ELEC 210 o ! LIV , SECOND, .FLOOR LIFE SAFETY PLAN BASIC CRITERIA CALL. EGRESS CAPACITY A. PRIME CODE OCCUPANCY AREA OCUPPANT OCCUPANTS 1.FLORIDA BUILDING CODE (FBC) 2007 1b. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, (SF GROSS) LOAD 2.FBC CHAPTER 11 FLORIDA ACCESSIBILITY MATERIALS (TYPE "SR ") If,—PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN RECESSED CABINET PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "R") 1d. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, CODE FOR BUILDING CONSTRUCTION 2001 SALES (201) 10,132 1/60 169 3.NFPA 101 LIFE SAFETY CODE 2003 LOCKERS (202) 412 1/50 9 B. TYPE OF CONSTRUCTION 332 1/100 1/300 1 1.INTERIOR RENOVATION EXISTING BUILDING OFFICE 06) THOUGHT THE BUILDING IN ACCORDANCE WITH NFPA 13 4 2.FBC CONSTRUCTION TYPE TRAINING (208) (NET)378 1/50 8 31IRE SPRINKLERED BUILDING OFFICE (209) 1,653 1/100 17 ELEC. ROOM (210) 117 1/300 1 C. OCCUPANCY CATEGORY DATA (212) 103 1/300 1 1.FBC MERCANTILE GROUP M CONFERENCE 214 357 1/100 4 2.FBC STORAGE GROUP S TECHNOLOGY 215 91 1/100 1 3.FBC BUSINESS GROUP B TECHNOLOGY 216 48 1/100 1 TOTAL 216 REQUIRED EGRESS WIDTH PER PERSON LEVEL: SECOND DOORS = 0.2 "x 216 PERSONS = 43.2" STAIRS = 0.3% 216 PERSONS = 64.8" PROVIDED EGRESS WIDTH PER PERSON LEVEL: SECOND DOORS = 192 " /0.2" = 960 PERSONS STAIRS � 117 " /0.3" = 390 PERSONS LIFE SAFETY LEGEND 1H FIRE RATED WALL ---------------- 2H FIRE RATED WALL — — 4i� FEE, FIRE EXTINGUISHER CABINET FK_B1 FIRE DEPARTMENT KNOX —BOX 81 Q EXIT SIGN "kP EMERGENCY LIGHT ® SMOKE DETECTOR F� FIRE ALARM CONTROL PANEL IU SPEAKER STROBE 1 TE: q4N 0 SEE SHEET A -10.1 & A -10.2 FOR WALL TYPES REFER TO FIRE ALARM do SPRINKLER DRAWINGS FOR DETAILS LIFE SAFETY NOTES la. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN SURFACED — MOUNTED CABINET PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "S ") 1b. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN SEMI— RECESSED CABINET PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "SR ") If,—PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN RECESSED CABINET PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "R") 1d. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN RECESSED ENAMEL —STEEL CONTAINER PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "E ") 2.,—LOCATE ONE (1) TYPE FIRE EXTINGUISHER IN EACH FIRE HOSE VALVE EXTINGUISHER CABINET ON EACH FLOOR. 3 —REFER TO DETAILS FOR RECESSED & SEMI— RECESSED CABINET DETAILS. 4. ONE FIRE EXTINGUISHER IS REQUIRED PER EACH 2500 SF OF FLOOR AREA, BUT NOT LESS THAN ONE TO EACH PATH OF EGRESS OR WITHIN A TRAVEL DISTANCE OF 75 FEET. 5.—SUPERVISED AUTOMATIC FIRE SPRINKLER SYSTEM PROVIDED THOUGHT THE BUILDING IN ACCORDANCE WITH NFPA 13 2 I LIFE SAFETY NOTES U YUV4v VY•"� � III W4YWY UYVYU :Y W•� = iY G y W W Y 4 v Ce W U U r. u Y Y W U U�.L l UU •, W • Ln rl C:) architect ,o 100 NORBERTO ROSENSTEIN ARCHITECT INC. ARC MTW - NT@IIOR DESM - M -ANNNG to 126 S. FEDERAL HIGHWAY 13- SUrTE # 202. DANIA BEACH, FLORIDA 33004 q� PH: (954) 922 -6551 `'- FAX= (954) 922 -7388 O EMAIL :info•ro8en8teinarchitect.com WEB: www.rosensteinarchitect.com `•j J L STATE REG. NO. AR0016674 O NATL. REG. NO. 69178 O LL COPYRIGHT @C 2009 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED O IN ANY FORM WITHOUT PERMISSION. u f N DESIGNED .G N.R. ,�+' %. , ./ /�, �� �`� �/ /�%% Vii, 3 N DRAWN j f/ ` S.S. TI CHECKED N.R. I HEREBY CERTIFY THAT THESE PLANS O WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. elton + Ian i 1710 "i'1i�t,:I.� III, A R Q U I T E C T 0 S A •�'a 0 C I A S fu• r RUT :76.575.840 -8 �",• ,�r�jr1 AURELIO GONZAL�'i0330 I U VITACURA '� W �Ff•,,:r o0 r.�� M O N Q� �O CL 0 S -26-2010 REVISION -N Q2 8 -14J-2010 REVISION V 0 a -11 -2010 REVISION 0 0 8-11 -2010 FIRE DEPT COMMENTS a R E V I S 1 0 N S V) 4_J COMM. DATE 2010 --31 8---5 -2010 Casa om WGIS 5701 SUNSET DR. SUITE B -10 SOUTH MIAMI FLORIDA, 33143 SECOND FLOOR LIFE SAFETY PLAN A -2.2 of 19 E O ..C_ N Co Q fu