07-1661-083WATER HEATER FRESH AIR INTAKE
3" OR 4" PVC, ABS OR CPVC
INTAKE VERTICALLY OR HORIZONTALLY.
3" MAX. 50 EQUIVALENT FEET,
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT 4" MAX. 120 EQUAVALENT FEET.
FIELD CONDITIONS. REFER TO ISOMETRIC RISER FOR PIPE SIZES. OVIDE A 2107
SIZES. SET HEATER THERMOSTAT AT 110' F. TEMPERATURE AND
150 PSI PRESSURE
RELIEF VALVE
HEAT TRAP WITH TEST LEVER
SIZED WITH AGA /CGA
TEMPERATURE STEAM
RATING 10% OVER
HOT WATER TO FIXTURES E`TEq0j q'11 ,
AS SHOWN ON PLANS PROVIDE A HARD,
COPPER RELIEF
VALVE DISCHARGE OF
PROVIDE FULL PORT BALL LINE FULL SIZE U
SHUTOFF VALVES ' VALVE OUTLET RUN
Lj
TO FLOOR DRAIN IN SAME 8
ROOM WITH
A VISIBLE AIR GAP IN
PROVIDE PIPE UNIONS, SAME ROOM PER FLORIDA
DIELECTRIC IF REQUIRED BUILDING CODE 2004 SEC.
FOR DISSIMILAR METALS. 504.7 AND 504.7.1
GAS SHUTOFF COCK
� MIN. 4 GAL. COLD WATER SUPPLY
6" LONG DIRT LEG EXPANSION TO WATER HEATER.
GROUND JOINT UNION TANK
RECIRCULATION
BURNER THERMOSTAT CHECK PUMP AQUASTAT AW
AND PRESSURE REGU- VALVE TIME CLOCK
_ "
LATOR FURNISHED HEAT TRAP
WITH WATER HEATER.
HOT WATER
WATER HEATER EXHAUST VENT FLOOR RECIRCULATION LINE
3" OR 4" PVC, ABS OR CPVC
VENT VERTICALLY OR HORIZONTALLY.
3" MAX. 50 EQUIVALENT FEET,
4" MAX. 120 EQUAVALENT FEET.
DRAIN VALVE BY DRAIN PAN WITH
ROVIDE A DRAIN -PAN, RUN HEATER MANUFACT. MINIMUM 2" HIGH SIDES
OVERFLOW LINE TO FLOOR DRAIN
IN THE SAME ROOM WITH AN
AIR GAP. 8
NOTE: DETAIL BASED ON "A.O. SMITH CYCLONE" MODEL FOR THE PRE - ENGINEERED
VENTILATION SYSTEM. CONSULT WITH ACTUAL MANUFACTURE FOR EXACT VENTILATION REQUIREMENTS
IF DIFFERENT MODEL IS INSTALLED.
GAS WATER HEATER DETAIL
NOT TO .SCALE
I
NOTES: 1. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP
2. PITCH DRAIN FOR PROPER RUNOFF.
3. MANUALLY PRIME FILL TRAP BEFORE START -UP TO FORM
INITIAL DRAIN SEAL.
4. SUPPORT LENGTHY DRAIN LINES TO PREVENT SAG AND
CONDENSATE OVERFLOW.
A/C UNIT CLEANOUT VENT LINE
CAP (TYP.) PERFORATED
CAP
F�F PITCH
DRAIN PAN
PITCH d
DRAIN PIPE v ••
TO MATCH DRAIN
OUTLET SIZE. ..
(a) THIS DIMENSION IN INCHES MUST BE
EQUAL TO THE MAXIMUM FAN SUCTION
THIS STANDARD DETAIL MUST (NEGATIVE) STATIC PRESSURE IN INCHES
BE REVIEWED AND SITE WG (WITH DIRTY FILTERS, COILS, AND
ADAPTED BY CONTRACTOR MAXIMUM AIR FLOW) + 1" W.G.
PRIOR TO USE FOR FINAL
EQUIPMENT. (b) THIS DIMENSION IN INCHES MUST BE
.EQUAL TO MIN. 1/2 OF THE (a) ABOVE
(c) EQUALS (a) + (b) + PIPE DIA. +
+ INSULATION
DRAW THRU UNINOT TCONDENSATE TRAP
SCALE
PROVIDE TEST TEE
WITH SCREWED COUNTER-
SUNK ABS PLASTIC PLUG:
TAPERED - THREAD WITH
TFE JOINT COMPOUND.
J
WHERE CLEANOUT TEE _
IS CONCEALED IN A
CHASE OR PARTITION,
PROVIDE A ROUND 18
GAUGE STAINLESS STEEL
COVER WITH BEVELED l
EDGES AND FLATHEAD
MACHINE SCREW.
E ' A:
CONCRETE
FLOOR
SLAB
COLUMN OR PARTITION
AS SHOWN ON FLOOR PLAN
CLEANOUT FACE SHALL
BE WITHIN 4" OF WAU_
SURFACE. PROVIDE
PIPE EXTENSION IF REQUIRED.
NOTE:
PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES
NOT SERVED WITH A FLOOR CLEANOUT. LOCATE ABOVE FIXTURE FLOOD RIM
WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS.
WALL CLEANOUT DETAIL
NOT TO SCALE
BY GAS COMPANY (VERIFY) BY PLUMBING CONTRACTOR
PRESSURE TEST COCK =Ar-r _,�-- BUILDING WALL.
GAS METER OF CFH GAS PIPE UP INTO BLDG.
CAPACITY SHOWN SIZE AS SHOWN ON PLAN.
ON PLANS USE BLACK STEEL PIPE.
STRAINER PIPE INCREASER.
(OPTIONAL) -
DIRT LEG AT BOTTOM
OF RISER ANCHOR
RISER TO WALL.
GRADE OR FLOOR
PAVEMENT I
+L
PRESSURE REGULATOR TO REDUCE PRESSURE TO 7" WC.
SHUT -OFF VALVE
VERIFY REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY.
CONTRACTOR SHALL PAY ALL GAS COMPANY FEES FOR' INSTALLATION.
USE WELDED OR SCREWED PIPE AND FITTINGS PER PLUMBING SPECS.
GAS SERVICE•'"DETAIL
NOT TO SCALE
PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT
IN PARTITION OR CHASE WHERE SHOWN ON PLAN. HORIZONTAL VENT
BELOW FLOOR IS NOT PERMITTED. OTHER VENTING METHODS MAY BE
USED IF APPROVED BY LOCAL CODE.
CONCRETE FLOOR
d .4 e.
MEMBRANE CLAMP-
ING COLLAR AND
SEEPAGE PAN
MAXIMUM TAILPIECE
LENGTH IS 2 FEET
UNLIMITED DISTANCE SLOPE WASTE AT
WHERE ENLARGED WASTE TWO PERCENT
LINE IS USED AS A
COMBINATION DRAIN
AND VENT SYSTEM.
PROVIDE TRAP PRIMER MAX.10' ON 3" WAS
MAX.6' ON 2" WASTE
LOCATE FLOOR DRAINS WHERE SHOWN ON DIMENSIONED ARCHITEC-
TURAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR DRAIN,
MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE
WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC. IF SITUATION
IS FLOOR SLAB ON GRADE, PROVIDE BACKFILL PER SPECIFICATIONS.
IF CONCRETE FLOOR IS NOT EXISTING, SET DRAIN IN PLACE AND POUR
AROUND IT. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL
IT. SET DRAIN BODY IN PLACE AND POUR AROUND IT. RECESS TOP OF
FLOOR DRAIN 1/2" BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT.
FLOOR DRAIN DETAIL
NOT TO SCALE
I
PLUMBING NOTES
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH FBC 2004,
APPLICABLE LOCAL CODES, RULES AND ORDINANCES.
2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE
HIMSELF WITH ALL EXISTING CONDITIONS.
3. ALL MATERIALS SHALL BE NEW.
4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST
CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. ALL
EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE
A PART OF THIS CONTRACT.
5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION
AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK.
6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND
TESTS, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO
BEGINNING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR
ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES.
7. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES,
PIPING, EQUIPMENT, ETC.
8. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH
THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT
PRIOR TO BEGINNING CONSTRUCTION.
9. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES
PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES.
10. WATER DISTRIBUTION PIPING ABOVE AND BELOW GROUND SHALL BE TYPE "L" COPPER.
COORDINATE WITH LOCAL JURISDICTION FOR ADDITIONAL REQUIREMENTS.
PROVIDE ALTERNATE FOR CPVC PIPING EQUAL TO BFGOODRICH "FLOINGUARD GOLD" FOR WATER
KNOWN OR DETERMINED TO HAVE ACIDIC CHARACTERISTICS. CONTRACTOR SHALL PERFORM A
WATER TEST TO DETERMINE WATER CHEMISTRY PRIOR TO ANY WORK OR PIPING INSTALLATION
AND SHALL SUBMIT TEST RESULTS TO ENGINEER FOR REVIEW AND APPROVAL.
11. SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE CAST IRON OR PVC, WHERE CODE ALLOWS.
PVC MAY NOT BE USED THRU RATED ASSEMBLIES OR IN PLENUMS.
12. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND APPROPRIATELY
MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR
TO INSTALLATION.
13. FURNISH AND INSTALL APPROVED WATER HAMMER ARRESTORS FOR ALL (GROUP) PLUMBING
FIXTURES, SIZED AND LOCATED PER MANUF.'S INSTALLATION INSTRUCTIONS AND WH -PDI 201.
14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND
EQUIPMENT CONNECTIONS. .
15. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PADS OR MATERIAL.
16. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY 'ROTECTED FROM
.FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL /FLOOR
SLEEVES WITH FIRE RATED FOAM, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS
AS PART OF THE PLUMBER'S WORK.
17. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM
DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BY
OWNER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE
AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION
WHICH MAY HAVE BEEN DAMAGED.
18. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES AND ALL WATER HAMMER
ARRESTORS. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND
MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED.
19. PROVIDE COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS
PANEL FOR ALL WALL CLEANOUTS FINISH TO MATCH FIXTURE TRIM.
20.N0 COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES
WHERE USED AS RETURN AIR PLENUMS. .
21. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR
EQUIPMENT ROOMS.
22. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCIBLE DIAGRAM
LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNER /OPERATOR.
23. ALL CONDENSATE DRAIN PIPING SHALL BE TYPE "L" COPPER WITH ARMAFLEX INSULATION
PER TABLE 411.1 F.B.C. 2004 WHERE USED IN A RETURN AIR PLENUM. PVC PIPING WITH
ARMAFLEX INSULATION MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES.
�_�E L'U, BING DRAWINGS FOR SIZE AND LOCATION OF PIPING.
CONDENSATE DRAIN PIPING SHALL BE INSULATED AND PIPE INSTALLATION SHALL INCLUDE A
CLEANOUT AT EACH CHANGE IN DIRECTION.
24. CONDENSATE LINES SHALL NOT DRAIN ON THE ROOFING SYSTEM OR ANY OF ITS COMPONENTS
AND CONDENSATE LINES NEED NOT COMPLY WITH MIN. CLEARANCE REQUIREMENTS
PER FBC 2004, PAR. 1522.3.5
25. PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL
SHUT -OFF.
26. WATER PIPING INSULATION SHALL BE ARMAFLEX OR EQUAL INSTALLED IN ACCORDANCE
WITH MANUFACTURERS INSTRUCTIONS FOR ALL HOT WATER PIPING. WHERE DOMESTIC
WATER TEMPERATURES CAN CAUSE SWEATING ALL COLD WATER PIPING SHALL BE INSULATED
WITH ARMAFLEX INSULATION, THICKNESS AS PER TABLE 411.1 OF FLORIDA ENERGY CODE.
27. ALL HORIZONTAL RAINWATER PIPING THAT RECEIVES CONDENSATE DISCHARGE FROM AIR
9,1710NJIINO .,EQUIPMENT SHALL BE INSULATED WITH 1" THK. ARMAFLEX.
28. TENANT SHALL COMPLETELY REMOVE ALL UNUSED PIPING, INCLUDING SANITARY, VENT, GAS
AND WATER SUPPLY PIPING. DO NOT ABANDON.
SHOCK ARRESTOR SCHEDULE
P.D.I. DESIGNATION MANUF. & MODEL FIXTURE UNITS CONNECTION
A SIOUX CHIEF 652 -A 1 -11 1/2"
B SIOUX CHIEF 653 -B 12 -32 3/4"
C SIOUX CHIEF 654 7C 33 -60 1"
SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO
ACCESS DOOR REQUIRED. CONFORMS TO ANSI /ASSE 1010 STANDARDS.
SLOPE OF HORIZ.
SIZE (inches)
DRAINAGE PIPE
MINIMUM SLOPE (inch per foot)
2-1/2 or less
PDA
1/4
3to6
EQUIPMENT SCHEDULE & DETAILS
1/8
8 or larger
P3.1
1/16
TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2004
1 i
PLUMBING SHEET INDEX
SHEET#
- DESCRIPTION
PDA
PLUMBING NOTES, LEGENDS, AND DETAILS
PO.2
EQUIPMENT SCHEDULE & DETAILS
P2.1
SANITARY PLAN > > >
P3.1
DOMESTIC WATER & GAS PLAN
P5.1
SANITARY ISOMETRICS
P6.1
DOEMSTIC WATER & GAS ISOMETRICS
,
,
„
,
Mave�i�k'Arci�itecture &
Design, Ilc.
6675 Westwood Blvd.
Suite 140
Orl d 1
PLUMBING FIXTURE SCHEDULE
PLUM
ING LEGEND
HLAV
WHITE, WITH SLOAN POLARIS FAUCET #SL -2711. CONTRACTOR TO SU PLY CONCEALED ARM SUPPORT
CARRIER FOR MOUNTING OF LAV. WADE MODEL # 520 -M36. SUPPL`� PLUMAEREX MODEL # 43::.,
CO
CLEAN OUT
LAVATORY, AMERICAN STANDARD DECLYN WALL HUNG #0321.075 WHITE W/ SLOAN POLARIS SL -2711
LAV
SANITARY SEWER PIPING
FD-
FLOOR DRAIN /
WCO
S- - - -
VENT PIPING
CW
DOMESTIC COLD WATER
ELONGATED RIM AND 1 -1/2" TOP SPUD, AMERICAN STANDARD 2234.015 MADERA AQUAMETER, 1.6
S- - --i
DOMESTIC COLD WATER PIPING
HW
DOMESTIC HOT WATER /
S- - -
HOT WATER PIPING (120')
WITH ELONGATED RIM AND 1 -1/2" TOP SPUD. 18" HIGH AMERICAN STANDARD #3043.102 ELDERLY
HWC
NEW CADET AQUAMETER, 1.6 GPF TOILET WITH SLOAN ROYAL #111 FLUSH VALVE AND A COMFORT
S- - - -
HOT WATER PIPING (140')
HB
HOSE BIBB
UR
WALL MOUNTED, WHITE URINAL. WALL CARRIER, WADE # 400AM11.
WATER HEATER SHALL BE 85 GAL. TURBOCHARGER GAS WATER HEATER.
GM
LOCHINVAR MODEL EPN150 -085, 150,000 BTU /HR NAUTRAL GAS INPUT.
S-- CD
CONDENSATE PIPING
GENERAL NOTES:
(2) - ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF FBC 2004.
GATE VALVE
SUPPLY TUBES, AND CLEANOUT COVER PLATES SHALL BE OF THE SAME FINISH AS THE ABOVE
SPECIFIED FAUCET AND PER ARCHITECTURAL FINISH SCHEDULE.
(4) - ALL FIXTURES SHALL BE ROUGHED IN PER MANUFACTURER CUT SHEET TO MAINTAIN UNIFORMITY.
S-- G -S
GAS PIPING
i
GAS COCK
WATER HAMMER ARRESTER (PDI No.)
S
PIPE RISl� UP
�--D -S
PIP E DOWN OR DROP
6 FD
FLOOR DRAIN
CAPPED END OF PIPE
�I
CHECK VALVE
�-
POINT OF `CONNECTION
GAS SOLENOID VALVE
P -TRAP
PLUMBING FIXTURE SCHEDULE
HANDICAP LAVATORY, AMERICAN STANDARD, DECLYN WALL HUNG LAVATORY MODEL #0321.075.
HLAV
WHITE, WITH SLOAN POLARIS FAUCET #SL -2711. CONTRACTOR TO SU PLY CONCEALED ARM SUPPORT
CARRIER FOR MOUNTING OF LAV. WADE MODEL # 520 -M36. SUPPL`� PLUMAEREX MODEL # 43::.,
INSULATION KIT. MUST MEET A.D.A. CODE.
LAVATORY, AMERICAN STANDARD DECLYN WALL HUNG #0321.075 WHITE W/ SLOAN POLARIS SL -2711
LAV
FAUCET. CONTRACTOR TO SUPPLY CONCEALED ARM SUPPORT CARRIER FOR MOUNTING OF LAVATORY.
WADE MODEL # 520
WCO
WALL CLEANOUT, WADE MODEL # 8590 TAPPED PLUG WITH 8480R.
WATER CLOSET, FLUSH VALVE BOWL; FLOOR MOUNTED, SIPHON JET ACTION VITREOUS CHINA,
ELONGATED RIM AND 1 -1/2" TOP SPUD, AMERICAN STANDARD 2234.015 MADERA AQUAMETER, 1.6
WC
GPF TOILET WITH A SLOAN ROYAL #111 FLUSH VALVE AND A COMFORT SEAT MODEL # C106C OPEN
FRONT SEAT LESS COVER.
HANDICAP WATER CLOSET - FLUSH VALVE BOWL; FLOOR MOUNTED, SIPHON JET, VITRROUS CHINA
WITH ELONGATED RIM AND 1 -1/2" TOP SPUD. 18" HIGH AMERICAN STANDARD #3043.102 ELDERLY
HWC
NEW CADET AQUAMETER, 1.6 GPF TOILET WITH SLOAN ROYAL #111 FLUSH VALVE AND A COMFORT
SEAT MODEL # C106C, OPEN FRONT SEAT LESS COVER.
URINAL AMERICAN STANDARD, WASHBROOK #6501.010, FLUSH VALVE SLOAN ROYAL #186 -1,
UR
WALL MOUNTED, WHITE URINAL. WALL CARRIER, WADE # 400AM11.
WATER HEATER SHALL BE 85 GAL. TURBOCHARGER GAS WATER HEATER.
GM
LOCHINVAR MODEL EPN150 -085, 150,000 BTU /HR NAUTRAL GAS INPUT.
RECIRC
RECIRCULATING PUMP TACO MODEL # 007
GENERAL NOTES:
(2) - ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF FBC 2004.
3 - ALL FIXTURE TRIM PACKAGES INCLUDING BUT NOT LIMITED TO TRAP, ANGLE STOP, FLUSH VALVE,
SUPPLY TUBES, AND CLEANOUT COVER PLATES SHALL BE OF THE SAME FINISH AS THE ABOVE
SPECIFIED FAUCET AND PER ARCHITECTURAL FINISH SCHEDULE.
(4) - ALL FIXTURES SHALL BE ROUGHED IN PER MANUFACTURER CUT SHEET TO MAINTAIN UNIFORMITY.
t
an o, Florida 3282
T: 407.351.8787
F: 407.351.9254
E:
Info @MaveBrickArchDes.com
AA. 26000903 AR.
91835
a conceptually
independent forum
M
r
� M
> M
N 0
CC) LL
cn •E
co ICU
C
Lid -rl- -r
��0
v!
m
w
co
0
C Q
o W
CL 0
U
w L1J
CD IX
0
I HEREBY CERTIFY THAT 11iESE DRAWINGS AND
SPECIFICATIONS WERE PREPARED UNDER MY
DIRECT SUPERVISION AND TO THE BEST OF MY
KNOWLEDGE COMPLY WITH THE STATE BUILDING
I
AND ZONING ORDINANCES.
SIGNED _
STATE REGISTRATION
DATE
ISSUED FOR PERMIT Oe� Og' 2007 PLUMBING NOTES
ISSUED FOR CONSTRUCTION
KAMM CONSULTING PROJECT #: 2007 -0307
PROJECT MANAGER Nicholas Melisiotis, P.E. l '
M M 1407 West N Crntec ve
Deerfield Beac �Icirida' gg442
Phone 954.949 £B 54.949.2201
engineering sulting.com
nsu 9 Certification o u oriza ' #1189
DIRECTOR OF ELECTRICAL ENGINEERING +
Lon T. Carte Florida License #35249
DIRECTOR OF MECHANICAL ENGINEERING * ' i Drawing N0.
Mircea Pella Florida License #4E79b • ' ' .a'j • -' '.
�• .....•• .� s .