07-1661-072s
•
•
•
•
I
1��•�M''�dY �� "M'�'�`��yl i�'�"�m,+wmy, V s+u'h,n* �n+.�YU ryyd..f�.P +.
ELECTRICAL SCHEDULE
CONN.
NO.
QTY.
L'I'EM DESCRIPTION
V
0
L
T
S
P
H
A
s
E
6675 Westwood Blvd.
WAD
STUB
ABOVE
FLOOR TO t
ELECTIUM CoN'T' TO II W
FINAL CONNECTION To:
�
HOUR
REMARKS
CIRCUIT DESIGNATION
ldlf.
AMP
HP.
JUNC.
BOX 011=
FIJ18H
JUNC.
EQ. NTD
BOX
EQ. VTD OVI'f
OUTLET
/
BY B.C.
1
1
UPRIGHT REFRIGERATOR
120
1
8.0
1/3
M
90"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P)
LMA-21
6
1PRINTERS
(TYPICAL REQUIREMENTS, ALL)
120
1
15.OEA
•E
- ch
co
E.C. TO PROVIDE DEDICATED CIRCUIT, ISOLATED GROUND AND EMPTY CONDUIT FOR comm. CIRCUIT. LOAD IS FOR VIRCUIT SIZE.
SEE FLOOR PLAN
6A
4
PRINTERS (CHEF'S COUNTER)
l5.OEAl
NOTE
•
E.C. TO CONNECT FROM J -BOX ON COLUMN THRU CHASE TO EQUIPMENT MOUNTED OUTLET.
SEE FLOOR PLAN
88
2
PRINTERS (BACK BAR)
15.0
30"
•
GROMMET IN BAR TOP?
SEE FLOOR PLAN
6C
9
PRINTER (FRONT BAR)
15.0
0
24"
•;,
SEE FLOOR PLAN
6D
BE
2
2
PRINTER (BACK PREP LINE )
PRINTER PANTRY COUNTER
15.OEA
15.0
BY
24"
•
•
ROUGH -IN TO FINISH ABOVE 58'H CIVERHSELF
E.C. TO CONNECT FROM J -BOX AT WALL THRU CHASE TO EQUIPMENT MOUNTED OUTLET.,
SEE FLOOR PLAN
SEE FLOOR PLAN
6F
1
PRINTER (ISLAND BAR)
15.OEA
O
U
NOTE
•
E.C. TO STUB UP FROM BELOW COMPRESSOR AND MOUNT ON TOP OF REFRIGERATOR.
SEE FLOOR PLAN
7
1
RAISED RAIL REFRIGERATOR
120
1
12.0
1/3
18'
•
n
CORD AND PLUG PROVIDED (NEMA 5 -20P)
LMA -19
9
1
EXHAUST HOOD LIGHTS
120
1
5.0
1
WFA
U
W
•
E.0 TO WIRE HOOD LIGHTS TO SWITCH ON HOOD; E.C. TO PROVIDE LAMPS FOR HOOD.
LMH -4
19
1
HALF HEIGHT HOLDING CABIINET
120
1
1.04
8.6
18'
•
Q
J
O
CORD AND PLUG PROVIDED (NEMA 5 -15P)
LMH-6
20
1
FIRE SUPPRESSION SYSTEM
NOTE
0
z
•
SEE FIRE PROTECTION NOTE THIS PAGE"
LMH -8
21
1
EXHAUST HOOD LIGHTS
120
1
10.0
SPECIFICATIONS WERE PREPARED UNDER MY
WFA
OF MY
•
AND ZONING ORDINANCES.
SIGNED
E.0 TO WIRE HOOD LIGHTS TO SWITCH ON HOOD; E.C. TO PROVIDE LAMPS FOR HOOD.
LMH -10
22
1
FRYERS WITH BUILT -IN FILTER
120
1
SCHEDULE
7.0
1/3 1
18'
•
CORD AND PLUG PROVIDED (NEIMA 5 -15P)
LMH -12
23
1
DOUBLE STACKED CONVECTION OVEN
120
120
1
1
11.6
11.6
3/4
3/4
18"
18"
•
•
CORD AND PLUG PROVIDED FOR EACH OVEN DECK (NEMA 5 -15P).
LMH -14
LMH -16
25
1
BUN TOASTER
208
1
2.78
13.4
48'
•
CORD AND PLUG PROVIDED (NEVA 6 -20P)
LMH -7,9
27
1
REFRIGERATED EQUIPMENT STAID
120
1
10.0
1/4
18'
•
CORD AND PLUG PROVIDED (NEMA 5 -20P). E.C. TO USE 010 WIRE.
LMH'11
32
2
FIRE SYSTEM PULL
1201
1 1
1
NOTE
SEE FIRE PROTECTION NOTE THIS PAGE. x'
LKA -9. LMA -9
34
35
1
1
COMPRESSOR FOR #64
COMPRESSOR FOR /41 & /43
208
208
3
3
6.2
6.2
1.5
1.5
WFA
WFA
•
•
LOCATED ON ROOF
LOCATED ON ROOF
LAA- 36,38,40
LOA- 8,8,10
37
1
STEAMER
208
3
9.0
28.1
18'
•
E.C. TO PROVIDE CORD & PLUG TO ALLOW FOR SERVICE.
LMH -1,3,5
40
1
MICROWAVE OVEN
120
1
1.0
13.2
NOTE
•
E.C. TO CONNECT FROM J -BOX ON COLUMN THRU CHASE TO EQUIPMENT MOUNTED RECEPTACLE CORD AND PLUG PROVIDED (N&k 5-15P)
LMA -2
41
1
REMOTE REFRIGERATOR
120
1
12.0
NOTE
•
•
E.C. TO CONNECT FROM J -BOX ON COLUMN THRU CHASE TO EQUIPMENT MOUNTED JUNCTION BOX.
LMA -4
42
1
TWO HOLE STEAM TABLE
208
1
12.0
NOTE
•
E.C. TO CONNECT FROM J -BOX ON COLUMN THRU CHASE TO EQUIPMENT MOUNTED JUNCTION BOX.
LMA-1.3
43
1
REMOTE REFRIGERATOR
120
1
12.0
NOTE
•
•
E.C. TO CONNECT FROM J -BOX ON COLUMN THRU CHASE M EQUIPMENT MOUNTED JUNCTION BOX.
LMA -6
45
1
UPRIGHT FREEZER
120
1
11.3
1/2
90
•
CORD AND PLUG PROVIDED (NEMA 5 -15P)
LMA -5
47
1
REFRIGERATED WELL
120
1
7.0
1/4
NOTE
•
E.C. TO CONNECT FROM J -BOX ON COLUMN THRU CHASE TO EQUIPMENT MOUNTED JUNCTION BOX. >
LMA-8
48
1
MICROPHONE
NOTE
•
E.C. TO RUN EMPTY CONDUIT DOWN COLUMN AND TO BLANK BOX AT CENTER OF CHEF'S COUNTER.
BLANK CONDUIT FROM COLUMN TO RUN ABOVE CEILING. MICROPHONE CONTRACTOR TO PROVIDE AND RUN WIRES *0. AV AREA.
SEE REMARKS NOTE.
52
3
DUAL HEAT LAMPS
208
1
0.1EA
NOTE
•
E.C. TO STUB CONNECTION FROM J -BOX ON COLUMN. E.C. TO THEN CONNECT TO REMOTE INFINITE SWITCHES M ,U ED IN
CHEF'S COUNTER THRU CHASE PROVIDED, TO HEAT LAMPS. LIGHTS LOCATED IN THE CENTER BETWEEN EACH DU SET TO BE
ON SEPERATE SWITCHES.
LMA -10.12
LMA -14
3
LIGHTS BETWEEN EACH DUAL
120
1
2.5EA
NOTE
•
57
1
COFFEE BREWER
1
15.6
48"
•
CORD AND PLUG BY E.C. BY OWNER, VERIFY REQ. PRIOR TO ROUGH -IN.
LKA -11
60
1
UNDERCOUNTER REFRIGERATOR
120
1
10.0
1/4 1
18'
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) ,>
LMA -7
64
1
REMOTE REFRIGERATOR
120
1
12.0
1
24'
•
•
E.C. TO CONNECTION FROM J -BOX IN WALL TO EQUIPMENT MOUNTED JUNCTION BOX.
LMA-11
66
1
DUAL HEAT LAMP
208
1
7.8
1
NOTE
•
E.C. TO STUB CONNECTION FROM J -BOX ON COLUMN. E.C. TO THEN CONNECT TO REMOTE INFINITE SWITCHES MOUNTED IN
CHEF'S COUNTER THRU CHASE PROVIDED, TO HEAT LAMPS. LIGHTS LOCATED IN THE CENTER BETWEEN EACH DUAL,#SET TO BE
ON SEPERATE SNATCHES. !
LMA -13,15
LMA -17
1
LIGHTS BETWEEN DUAL HEAT LAMP
120
1
2.0
NOTE
•
76
1
DISHMACHINE
WITH BUILT -IN BOOSTER HEATER
208
208
3
3
30.0
91.7
83.9
70'
70"
•
•
TWO SEPARATE CONNECTIONS FOR DISH MACHINE AND BOOSTER HEATER. °�
LKA -1,3,5
LKA -2'4'6
78
1
TABLE LIMIT SWITCH
30'
•
•
E.C. TO INTERCONNECT TO DISHMACHINE IN CONDUIT IN WALL (ITEM 076). A
SEE REMARKS NOTE
83
100
1
1
MIXER (60 QT.)
COOLER COMPRESSOR
208
208
3
3
10.0
8.1
2.7
2.0
WFA
48'
•
•
E.C. TO PROVIDE CORD AND PLUG
LOCATED ON ROOF
LAA- 7.9.11
LAA- 12,14,16
101
1
COOLER COIL
120
1
2.7
WFA
•
E.C. TO FIELD WIRE TEMPERATURE CONTROLS, LIQUID LINE SOLENOID VALVES AND DEFROST TIME CLOCK AT COIL IN'-DE
WALK -IN COOLER.
LM -18
103
1
WALK -IN COOLER /FREEZER
120
1
20EA I
WFA
•
LOAD IS FOR BREAKER SIZE. E.C. To PIPE THRU TOP OF COOLER TO DOOR LIGHT W/J -BOX. MOUNT AND WIRE E'fW LIGHTS
AS SHOWN; CONDUIT TO BE RUN ON EXTERNAL TOP OF COOLER/FREEZER. LOW -TEMP HIGH - OUTPUT BALLAST TOPERATE IN
TEMPERATURES TO -20`F SUPPLIED BY KEC. BULBS SUPPLIED BY E.C. E.C. TO PROVIDE FROM THIS SAME CIRCI IT A DUPLEX
FOR TEMP. ALARM FOR COOLER AND FREEZER. (1.0 AMP EACH).
LM -20
105
1
1
FREEZER COIL
FREEZER COIL
208
120
1
1
6.3
20.0
WFA
•
E.C. TO FIELD WIRE TEMPERATURE CONTROLS, LIQUID LINE SOLENOID VALVES AND DEFROST TIME CLOCK AT COIL II IDE WALK -IN
FREEZER. E.C. TO PROVIDE DUPLEX AT COIL FOR DRAIN LINE HEATER. LOAD IS FOR CIRCUIT SIZE
LM-22.24
LAA -26
106
1
FREEZER COMPRESSOR
208
3
10.7
2.0
WFA
•
LOCATED ON ROOF r °"
LAA- 35,37,39
108
1
ICE MACHINE
208
3
12.0
72'
•
20 AMP CIRCUIT REQUIRED
LM-13,15,17'
119
1
REMOTE ICE MACHINE CONDENSER
NOTE
CONDENSER FAN MOTORS ARE POWERED FROM ICE MACHINE CONTROL PANEL CONDUIT W /(2) WIRES FOR CONNECI9N REQUIRED
BETWEEN ICE MACHINE & CONDENSER TERMINATING W /JB AT CONDENSER. VERIFY LOCATION ON ROOF; MAIMUM 5b' IDEAL.
SEE REMARKS NOTE
122
1
REMOTE ICE MACHINE CONDENSER
NOTE
CONDENSER FAN MOTORS ARE POWERED FROM ICE MACHINE CONTROL PANEL. CONDUIT W /(2) WIRES FOR CONNECION REQUIRED
BETWEEN ICE MACHINE & CONDENSER TERMINATING W /JB AT CONDENSER. VERIFY LOCATION ON ROOF; MAIMUM 5 °- IDEAL.
SEE REMARKS NOTE
127
1
1 ICE MACHINE
208
3
12.01
1 72'
•
20 AMP CIRCUIT REQUIRED
LAB -2.4.6
129
1
WALK -IN BEER COOLER
120
1
20EA
WFA
•
LOAD IS FOR BREAKER SIZE. E.C. TO PIPE THRU TOP OF COOLER TO DOOR LIGHT W/J -BOX, MOUNT AND WIRE WRA LIGHTS
AS SHOWN; CONDUIT TO BE RUN ON EXTERNAL TOP OF COOLER. LAW -TEMP HIGH - OUTPUT BALLAST TO OPERATE .(IN
TEMPERATURES TO -20'F SUPPLIED BY KEC. BULBS SUPPLIED BY E.C. E.C. TO PROVIDE FROM THIS SAME CIRCUIT A DUPLEX
FOR TEMP. ALARM (1.0 AMP). >
LAB-8
132
1
BEER COOLER COIL
120
1
2.7
WFA
•
E.C. TO FIELD WARE TEMPERATURE CONTROLS, LIQUID LINE SOLENOID VALVES AND
DEFROST TIME CLOCK AT COIL INSIDE WALK -IN COOLER. '�
LAB -7
133
1
BEER COOLER COMPRESSOR
2081
3
8.1
2.0
1 NOTE
1 LOCATED ON ROOF
LAB -1,3,5
135
4
CARBONATOR
1201
1
7.OEA
1
98"
1 BY OWNER. VERIFY REQ. PRIOR To ROUGH -IN.
LAA -19. LM -21, LAA -23, LM -25
138
1
UNDERBAR PLUGMOLD
120
1
20.0
WHIP
•
E.C. TO PROVIDE & WIRE PLUGMOLD TO UNDERSIDE OF BAR TOP; SEE. ARCH. DINGS; ENGINEER TO SIZE CIRCUIT/V AD FOR
PWGMOLD AND LIGHTS FOR EACH BAR: WHIPS TO COME ABOVE 37'H EQUIPMENT BACKSPLASHES.
L.KA -25
LKA -27
UNDERBAR LIGHTS
120
1
20.0
WHIP
•
139
1
BOTTLE COOLER
120
1
9.3
1/3
18"
ICORD AND PLUG PROVIDED (NEMA 5 -15P) 15 AMP CIRCUIT REQUIRED. /
LKA -7
148
10
CASH REGISTERS
120
1
15.0
24"
•
E.C. To PROVIDE DEDICATED CIRCUIT, ISOLATED GROUND & EMPTY CONDUIT FOR COMM. CIRCUIT; LOAD IS FOR CIR UIT SIZE.
BY OWNER - VERIFY REQUIREMENTS. (TYPICAL ALL): E.C. TO COORDINATE OUTLET PLACEMENT WITH ARCHITECTURAU,BACKBAR.
SEE FLOOR PLALN
147
1
BACK BAR REFRIGERATOR
120
1
8.8
1/3
18"
•
CORD AND PLUG PROVIDED (NE)AA 5 -15P) C
LKA -12
150
2
UNDERBAR PLUGMOLD
120
1
20.0
WHIP
•
E.C. TO PROVIDE & WIRE PLUGMOLD TO UNDERSIDE OF BAR TOP; SEE. ARCH. DINGS; ENGINEER TO SIZE CIRCUIT /LIVID FOR
PL,UGMOLD AND LIGHTS FOR EACH BAR; WHIPS TO COME ABOVE 37'H EQUIPMENT BACKSPLASHES. ,a
LKA -13, LKA -20
LKA-15. LKA -22
UNDERBAR LIGHTS
120
1
20.0
WHIP
•
158
1
j BOTTLE COOLER
120
j 1
9.3
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) 15 AMP CIRCUIT REQUIRED. A
LKA -24
172
1
BOTTLE COOLER
120
1
9.3
1/3
18'
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) 15 AMP CIRCUIT REQUIRED. STUB UP FROM FLOOR.'
_
177
1
PASS -THRU BACK BAR REFRIGERATOR
120
1
8.8
1/3
STUB
•
CORD AND PLUG PROVIDED (NEMA 5 -15P); E.C. TO STUB UP BELOW COMPRESSOR AND MOUNT OUTLET IN HOUSWG.
LKA -19
178
1
PASS -THRU BACK BAR REFRIGERATOR
120
1
8.8
1/3
STUB
•
CORD AND PLUG PROVIDED (NEMA 5 -15P); E.C. TO STUB UP BELOW COMPRESSOR AND MOUNT OUTLET IN HOUSINQv
LKA -21
i 184
2
UNDERBAR PLUGMOLD
120
1
20.01
WHIP
•
E.C. TO PROVIDE & WIRE PLUGMOLD TO UNDERSIDE OF BAR TOP; SEE. ARCH. DINGS; ENGINEER TO SIZE CIRCUIT/LOAD FOR
PWGMOLD AND LIGHTS FOR EACH BAR. WHIPS TO COME ABOVE 37'H EQUIPMENT BACKSPLASHES. '
LBA -1, L.BA -5
LBA -3. LBA -7
UNDERBAR LIGHTS
120
1
20.01
WHIP
•
185
1
BOTTLE COOLER
120
1
9.3
1 1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) 15 AMP CIRCUIT REQUIRED.
LBA -6
192
1
PASS -THRU BACK BAR REFRIGERATOR
120
1
8.8
1/3
18"
•
CORD AND PLUG PROVIDED (NE)AA 5 -15P)
LRA -8
• 202
2
UNDERBAR PLUGMOLD
120
1
20.0
WHIP
•
E.C. TO PROVIDE & WIRE PLUGMOLD TO UNDERSIDE OF BAR TOP; SEE. ARCH. DWGS; ENGINEER TO SIZE CIRCUIT/ FOR
PLUGMDLD AND LIGHTS FOR EACH BAR: WHIPS TO COME ABOVE 3711 EQUIPMENT BACKSPLASHES.
LKB -1
LKB -3
UNDERBAR LIGHTS
120
1
20.0
WHIP
•
210
1
2 -DOOR UNDERCOUNTER REFRIGERATOR
1201
1
8.8
1/3
18"
•
CORD AND PLUG PROVIDED (NE)AA 5 -1'5P)
LKB -5
211
1
SUSHI CASE CONTROL WIRING
1201
1
15.0
18"
•
•
FOR REFRIGERATION CONTROLS.
L KB -7
212
1
2 -DOOR UNDERCOUNTER REFRIGERATOR
120
1
8.8
1/3
18"
•
ICORD AND PLUG PROVIDED (NEMA 5 -15P) ,
LKB -9
213
1
1 SUSHI CASE CONTROL WIRING
120
1
15.0
18'
1 •
•
IFOR REFRIGERATION CONTROLS.
LKB -11
214
1
ITOASTER OVEN
120
1
12.5
48"
•
ICORD AND PLUG PROVIDED (NEMA 5 -15P) +
LKB -13
215
1
MICROWAVE OVEN
120
1
1.2
16.8
48"
•
ICORD AND PLUG PROVIDED (NEMA 5 -20P)
l K8 -15
216
1
BOTTLE COOLER
120
1
9.3
1/3
18'
•
ICORD AND PLUG PROVIDED (NE)AA 5 -15P) 15 AMP CIRCUIT REQUIRED.
L.KB -17
217
1
2 -DOOR BACK BAR REFRIGERATOR
120
1
8.8
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) /'
LKB -19
220
1
COMPRESSOR FOR /211 & /213
2081
1
1
9.5
1.0
WFA
•
VERIFY LOCATION WITHIN SPACE ABOVE CEILING IN KITCHEN
LAA -32 34
• 300
11
CASH REGISTERS
120
1
15.0
24"
•
E.C. TO PROVIDE DEDICATED CIRCUIT, ISOLATED GROUND & EMPTY CONDUIT FOR COMM. CIRCUIT; LOAC IS FOR CIR UTT SIZE.
BY OWNER - VERIFY REQUIREMENTS. (TYPICAL ALL)
SEE FLOOR PLALN
• 301
12
1PRINTER (FRONT BAR)
120
1
15.OEA
24"
•
SEE FLOOR PLALN
• 312
2
UNDERBAR PLUGMOLD
120
1
20.0
WHIP
•
E.C. TO PROVIDE & WIRE PLUGMOLD TO UNDERSIDE OF BAR TOP; SEE. ARCH. DINGS; ENGINEER TO SIZE CIRCUIT /OAD FOR
PWGMOLD AND LIGHTS FOR EACH BAR; WHIPS TO COME ABOVE 37"H EQUIPMENT BACKSPLASHES.
LMB -1
LMB -3
UNDERBAR LIGHTS
120
1
20.01
WHIP
•
321
1
BOTTLE COOLER
120
1
9.3
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) 15 AMP CIRCUIT REQUIRED. ;rd
LMB -2
332
1
BOTTLE COOLER
120
1
9.3
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) 15 AMP CIRCUIT REQUIRED.
LMB -4
333
1
2 -DOOR BACK BAR REFRIGERATOR
120
j 1
1
8.8
1/3
1
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) A
L.MB -6
334
1
2 -DOOR BACK BAR REFRIGERATOR
120
1
8.8
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P)
LMB -8
• 341
5
CARBONATOR
120
1
7.OEA
98"
•
BY OWNER, VERIFY REQ. PRIOR TO ROUGH -IN.
LEA -22, LBA -24, LBA -26. LBA -28. LBA -30.
342
1
ICE MACHINE
208
3
12.0
72"
•
20 AMP CIRCUIT REQUIRED t
LBA- 32,34,36
347
1
REMOTE ICE MACHINE CONDENSER
NOTE
CONDENSER FAN MOTORS ARE POWERED FROM ICE MACHINE CONTROL PANEL. CONDUIT W /(2) WIRES FOR CONNECTON REQUIRED
BETWEEN ICE MACHINE & CONDENSER TERMINATING W /JB AT CONDENSER. VERIFY LOCATION ON ROOF, MAIMUM 5 IDEAL
SEE REMARKS NOTE
• 349
2
UNDERBAR PLUGMOLD
120
1
20.0
WHIP
•
E.C. TO PROVIDE & WIRE PLUGMOLD TO UNDERSIDE OF BAR TOP; SEE. ARCH. DINGS; ENGINEER TO SIZE CIRCUIT/ L FOR
PLUGMOLD AND LIGHTS FOR EACH BAR. WHIPS TO COME ABOVE 37'H EQUIPMENT BACKSPLASHES.
LBA-9, LM -13
L.BA -17 LBA -15
UNDERBAR LIGHTS
120
1
20.0
WHIP
•
353
1
2 -DOOR BACK BAR REFRIGERATOR
120
1
8.8
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P)
LBA -17
359
1
2 -DOOR BACK BAR REFRIGERATOR
120
1
8.8
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P)
LBA -19
365
1
BOTTLE COOLER
120
1
9.3
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) 15 AMP CIRCUIT REQUIRED.
LBA -21
357
1
BOTTLE COOLER
120
1
9.3
1/3
18"
•
CORD AND PLUG PROVIDED (NEMA 5 -15P) 15 AMP CIRCUIT REQUIRED.
LBA -23
CO
8
CONVENIENCE OUTLET
120
1
O.OEA
48'
•
SEE FLOOR PLALN
COA
1
CONVENIENCE OUTLET
120
1
O.OEA
NOTE
•
E.C. TO CONNECT FROM J -BOX IN WALL /COLUMN TO EQUIPMENT MOUNTED OUTLET.
LMA -20
COB
LCOC
1
2
CONVENIENCE OUTLET
CONVENIENCE OUTLET
120
120
1
1
20.0
120.0
1
WFA
1 WFA
I
1
•
•
FROM ABOVE TO 78" AFF. WITH TWIST LOCK RECEPTACLE.
1 E.C. TO CONNECT FROM J -BOX IN COLUMN TO EQUIPMENT MOUNTED OUTLET.
UM-22
SEE FLOOR PLALN
• - INDICATES ITEMS PROVIDED BY OWNER OR BY OTHERS. /
VERIFY ALL REQUIREMENTS PRIOR TO ROUGH -IN. t�
CITY OF SOUT
BU"DING DE -r.
ELECTRICAL SECTIoPI
1 �
APPROVED BY.
DATE: ~_
I ISSUED FOR PERMIT OcL 08, 2007
ISSUED FOR CONSTRUCTION • -Ott.:-
KAMMCONSULTTNGPROJECT #: 2007 -0307' .. •• F�
PROJECT MANAGER Nicholas Melisiotis, P.E. V •, •r f�� •• 't'
1407 West Ne o Cc�er Dnve .
G
$ % Deerfield $each, rich
O �(� QO EeAAM Phone 954.949.21 9.22b1
17 • Z tA�Y engineeringg dGlcam . i
Certificatift ofA 'b 189:
DIRECTOR OF ELECTRICALENGINEERINGCe ber i 2�b7
�j Lon T. Carte Florida License #35249
Q DIRECTOR OF MECHANICAL ENGINEERING
Mircea Pella Florida License 948798
I - -
Maverick Architecture &
- - - -Design, Ilc.
6675 Westwood Blvd.
Suite 140
Orlando, Florida 32821
T: 407.351.8787
F: 407.351.9254
E:
Info @MaverickArchDes.com
AA. 26000903 AR.
91835
a conceptually
independent forum
M
M
M
r
CU
0
•E
- ch
co
1} L
.,C
o
05
CV
0
H
z
W
O
U
c
o
�
n
O
w
`o
m
U
W
Z
O
Q
J
O
0
z
I HEREBY CERTIFY THAT THESE DRAWINGS AND
SPECIFICATIONS WERE PREPARED UNDER MY
DIRECT SUPERVISION AND TO THE BEST
OF MY
KNOWLEDGE COMPLY WITH THE STATE BUILDING
AND ZONING ORDINANCES.
SIGNED
STATE REGISTRATION
DATE
EQUIPMENT
SCHEDULE
E302
Drawing No.