07-1661-068(A) GI 1%2" 60" MINIMUM X 1 -1/2- X 0.054 (16 GA.) SEE ARCH. RETAINING ANGLES MUST OVERLAP STRUCTURE OPENING 100- 1" MINIMUM AND COVER CORNERS OF OPENINGS AS SHOWN. FIRE RESISTIVE MATERIAL (B) CLEARANCE: 1/8" PER LINEAR FOOT 140- BOTH DIMENSIONS DUCT SHALL ATTACH (C) STEEL SLEEVE: TO SLEEVE (STYLE "B -) (B) (D) APPROVED FIRE DAMPER, CURTAIN BLADE TYPE e WITH 212• FUSIBLE LINK 91835 (E) SECURE RETAINING ANGLES TO SLEEVE a conceptually NO. 10 STEEL SCREWS independent forum (F) SECURE DAMPER TO SLEEVE ON 8- CENTERS WITH WOOD STUD NO. 10 STEEL SCREWS I SEE ARCH. I (H) I (F) (G) CONNECT DUCT TO SLEEVE WITH BREAKAWAY CONNECTION (H) FULLY GASKETED HINGED CAM LOCK FIRE DAMPER > ACCESS DOOR. LABEL "FIRE DAMPER ACCESS ". 'i NOTE •, •0 ALL SMOKE AND FIRE DAMPERS (G) co (UNDER 16- IN HEIGHT) SHALL BE (A) r OVERSIZED BY 2" AND TRANSITIONED (E) t• "a DOWN TO DUCT SIZE TO MAXIMIZE co FREE AREA. _ O (D) OPENING TO BE LINED WITH FIRE 60" RESISTIVE MATERIAL OF RATING SEE ARCH. EQUAL TO THAT OF THE WALL 100- 205 -330 CFM FIRE RESISTIVE MATERIAL 335 -450 CFM 140- FIRE DAMPER SLEEVE F: 407.351.9254 BREAK —AWAY CONNECTION Info @MaverickArchDes.com AA. 26000903 AR. DUCT 1Y 91835 ,, a conceptually (C) independent forum WOOD STUD I SEE ARCH. I DUCT (A) FIRE RESISTIVE MATERIAL METAL STUD AROUND PERIMETER OPENING I STYLE 'B" DYNAMIC FIRE SCALE DETAIL NOT TO MAIN DUCT N. \ \ D= \\\ TM -CfF \ 9mUm SUPPLY GRalJ' DOUBLE M=nm WH OPPOSED BLADE DAMPER SIDEWALL GRILLE DETAIL a NOT TO SCALE M7 LOCKING QUADRANT GALV. STEEL ROD OR NYLON DRAWBAND AND TO BE EXPOSED STRAP SUPPORTS PER MASTIC AT EACH CONNECTION SMACNA STANDARDS FLEXIBLE DUCT WITH SIDE TAKE —OFF FITTING INSULATION do WITH DAMPER, BELL MOUTH VAPOR BARRIER OR SHOETAP TYPE SQUARE TO ROUND MAIN SUPPLY AIR ADAPTER TIE TO DUCT, SEE PLANS FOR STRUCTURAL TYPE AND INSULATION SUPPORTS -- ----- -- = --- -- GYPSUM BOARD / CEILING 2" WIDE METAL BAND / __ :: .:: SUPPORT ILOUVERED FACE CEIUN DIFFUSER ROUNDE TO I 1 -1/2" X 1 -1/2" X 1/8- GALV. ADAPTER ANGLE OR STRAP PER SMACNA II CONNECT INNER DUCT WITH DRAWBAND AND SEAL WITH TAPE/MASTIC OUTERDUCT AT NECK CONNECTION PROVIDE THERMAL INSULATION BLANKET IF INSTALLED IN UNCONDITIONED SPACE SUSPENDED TYPE LOUVERED FACE CEILING DIFFUSER CEILING SYSTEM WITH 2' X 2' LAY —IN ALUM. PANEL TYPICAL DIFFUSER DETAIL 8 NOT TO SCALE M7 UNISTRUT CONNECI To FLOOR SLABS. UNISTRUT 1-1/2- TAPCONS. BRACKET CHASE FU GALVANIZED PIPE CLAMP W/ELASTOMERIC UNISTRUT CONNECTION ISOLATOR, GALV. NUT do WASHER TO FLOOR SLABS. GALVANIZED PIPE CLAMP SEE ELEVATION DETIAL W/ GALV. NUT & WASHER 1 "x1 "x1 -1 /2" FU (TYP-) �TYP. UNINSULATED L— TYP. SUCTION LINE WITH LIQUID LINE EXTERNAL INSULATION REF NOTE: 1. PIPE SIZES INDICATED ON PLANS FLC 2. SEE AR04ITECTIJAL DRAWINGS FOR CHASE CONSTRUCTION. 1 COMMON CORRUGATED METAL DUCT, SEE PLAN FOR SIZE SHEETMETAL ROUND CONN SEE PLAN FOR END SIZES l • CORRUGATED METAL SEE PLAN FOR SIZE DUCT ( �— PANDUIT STRAP (TYP) CEILING INSERT WEER SAME THICKNESS AS TRANSFERSE DUCT CEILING SLAB 1 1/2 "SHEET METAL SLEEVE. LLU 5/8" 1/2 STEEL ROD SCREWED RIVET TO DUCT AT TOP AND INTO INSERT IN CEILING SLAB. BOTTOM. SLEEVE TO BE PROVIDE THREADED COUPLING OF SHEET METAL SAME GAUGE AS DUCT. L AT BOTTOM OF DUCT PULLED WASHER UP TIGHT TO SUPPORT DUCT MANUAL VOLUME DAMPER BUCKLEY BELLMOUTH — AIRTITE "BM" FITTING. MAIN DUCT CEILING DIFUSER REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE SUPPORT TO STRUCTURE ABOVE. INSULATED FLEXIBLE DUCT 4' -0" MAX. LENGTH IF N.O.I. METAL CLAMP AROUND FLEX DUCT do COLLAR. CONNECTION TO BE DRAWN TIGHT do TAPED. FLEX BCFEDWF 60" 50 -125 CFM 80" 130 -200 CFM 100- 205 -330 CFM 120' 335 -450 CFM 140- 455 -7GD CFM v I FLEX DUCT CONNECTION DETAIL � NOT TO SCALE M7 SHAFT EXTENSION (LOCKING HARDWA EXTENDED TO SUII INSULATION THICK! 2" x 1/2" x 8" STRUCTURAL FORMED CHANNEL FRAME — WIDTH SHALL NOT EXCEED 48" i ALL BRANCH DUCTS SHALL HAVE VOLUME DAMPERS. 1/2" x 1/2" ANGLE STOP BAR (TYP.) OPPOSED BLADE VOLUME DAMPER Z NOT TO SCALE M7 ELBOW CC TURNING HANGING HANG ALL DUCT PER SMACNA STANDARDS CHANNEL STRAP do SADDLE TURNING TEE SPUTTER DAMPER CONTROL ROD W/ LOCK M7 MAIN DUCT SPUTTER DAMPER CLINCH EDGES I BRANCH DUCT / / / SPACER REO'D ON INSULATED DUCT SET SCREW GALV. STEEL ROD TYPICAL DUCT TAP -OFF 110 NOT TO SCALE M7 "RUSKIN" MODEL CDBOVG2 WITH 12OV -10 MOTORIZED ACTUATOR. DAMPER SHALL BE CLOSED WHEN POWER IS OFF. DAMPER SHALL BE INTERLOCKED WITH A/C UNIT CONTROL SO THAT WHEN DAMPER IS IN CLOSED POSITION A/C UNIT SHALL NOT OPERATE. 0 • BOLT DAMPER TO c WALL WITH 5/16" 0 BOLTS TO METAL WALL wool STUD FRAME. O ® 0 BOLT FLANGE TO EXISTING DUCT. 0 PROVIDE FLANGE FOR c EXISTING DUCT. MOTORIZEDDDAMPER DETAIL 3 7 TURNING VANES (TYPICAL) THROAT SIZE AS INDICATED ON PLANS — LENGTH -WI OR W2 WHICH EVER IS LARGER CLOSED L HEM EDGE PIVOT FLOW ► VENTILGCK #603 BALL JOINT 1/4 "0 CLERANCE SUP SLEEVE 1/4 "0 PUSH PULL ROD 1/4" SET SCREW LOCK tail• BRANCH DUCT 3 z a� W2 RECTANGULAR TEE SUPPLY DUCT DETAIL NOT TO SCALE M7 12 GAUGE WIRE OR 1/4" ROD TO UNDERSIDE OF rROOF DECK HANG FLEXIBLE DUCTS WITH 1.5- WIDE 26 GA. STEEL STRAPS WRAPPING UNDER DUCT EVERY 4 FT. MAXIMUM. 1" WIDE 22 GAUGE STRAP WRAPPING UNDER DUCT AND ATTACHED TO JOISTS OR UNDERSIDE OF ROOF DECK /SLAB-7 DUCT DUCT 1" 8' MAX 8' MAX ' I 22 GAUGE 1 "X2 "X1- ANGLE CHANNEL 4 4 "X2 "X2" 4" HANG ALL DUCT PER SMACNA STANDARDS DUCT SUPPORT DETAIL n NOT TO SCALE M7 CITY OF SOUTH MIAMI BUILDING DEPT. MECHANICAL SECTION APPROVED BY: DATE: U ' ISSUED FOR PERMIT Oct 08, 2007 ISSUED FOR CONSTRUCTION GK;AMM CONSULTING PROJECTM 2007 -0307 PROJECT MANAGER Nicholas Melisiotis, P.E. * `' % F l�• , a , l , ►�" tN i� i 1407 West N CL� • • • '•' Deerfield Beach, ldrhk'33442''- "�'• Phone 954.5L49,2290 Fax 9 01 0 A', �V engineerinkammcaul Certificati on off, utho 8 DIRECTOR OF ELECTRICAL ING � O y 14; - Lon T. Carter Florida License #35249 DIRECTOR OF MECHANICAL ENGINEERING t l 1 0 Fi`O ' •`(� Mircea Pella Florida License #48798 .� Maverick Architecture 8L Design, Ilc. 6675 Westwood Blvd. Suite 140 Orlando, Florida 32821 T: 407.351.8787 F: 407.351.9254 E: Info @MaverickArchDes.com AA. 26000903 AR. 91835 a conceptually independent forum CO M > M 'i CU 0 0 co LL r •E Y` c co .R1 _ O � LO r- --- 0 U) co O C o Q n Q m U LU m O 0 It I HEREBY CERTIFY THAT THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED UNDER MY DIRECT SUPERVISION AND TO THE BEST OF MY KNOWLEDGE COMPLY MATH THE STATE BUILDING AND ZONING ORDINANCES. SIGNED STATE REGISTRATION DATE MECHANICAL DETAILS ■ Drawing No.