Loading...
07-1661-014ACOUSTICAL MATERIALS SYMBOL DESCRIPTION CONTACT ACT -1 2'X2' X 3/4" MILLENIA CUMAPLUS USG WALL HUNG PANELS #76505, TILE EDGE: SQUARE EDGE 11LE COLOR: WHITE, GRID: WHITE 800.950.3839 TBD COMPASSO EDGE 8" PHONE ACT -2 M 2'X4" X 1/2" SHEET ROCK BRAND USG q LAY -IN CEILING PANEL " CLIMAPLUS" #3270 800.950.3839 ch •ca NRC /CAC RANGES (FIRECODE): .10/35 -40 OUTLET TILE COLOR: WHITE EDGE: SQUARE EDGE (WHITE) ALLOW 75W JUNO LIGHTING ACT -3 USG 2'X4' X 3/4" MILLENIA CUMAPLUS USG PANELS #76505, EDGE: SQUARE EDGE 800.950.3839 TILE COLOR: WHITE 0 Co GRID COLOR: WHITE DOUBLE DUPLEX (847)827 -9880 ACT -4 USG 12 "X12" X 3/4" MILLENIA CUMAPLUS USG OUTLET (QUAD) TILE, EDGE: DXL CONCEALED -SESK (WHITE) 800.950.3839 GENLYTE TILE COLOR: WHITE DBL DPLX (QUAD) 413MTX /4020MREX GRID COLOR: WHITE ROCHELLE LEWIS 1. REFER TO SHEET A5.1 FOR CEILING TYPES AND ADDITIONAL NOTES. 2. PROVIDE CEILING FINISHES AND HEIGHTS AS INDICATED ON THE ROOM FINISH SCHEDULE, UNLESS INDICATED OTHERWISE ON THE REFLECTED CEILING PLAN. 3. SUBCONTRACTORS SHALL COORDINATE THE INSTALLATION OF THE FINISH CEILING WITH ALL APPLICABLE TRADES TO ASSURE PROPER ALIGNMENT OF: UGHT FIXTURES, MECHANICAL GRILLS, SPRINKLER HEADS, LIGHTS, EXIT SIGNS, AUDIO SPEAKERS, ETC. VERIFY ANY EQUIPMENT DISCREPANCIES WITH THE ARCHITECT, PRIOR TO INSTALLATION OF THAT EQUIPMENT. 4. ALL SPRINKLER HEADS, LIGHTS, SPEAKERS AND OTHER CEILING MOUNTED EQUIPMENT SHALL BE CENTERED IN THE CEILING TILE UNLESS INDICATED OTHERWISE. IN SPLINE CEILING, DIMENSIONS FOR LIGHTS ARE APPROXIMATE TO THE CENTER OF THE TILE. 5. IT SHALL BE THE RESPONSIBILITY OF THE PAINTING SUBCONTRACTOR TO PAINT EXPOSED TRIMS ON ALL THE CEILING MOUNTED EQUIPMENT (INCLUDES TRACK LIGHT FIXTURES, SPEAKER TRIMS, JUNCTION BOX PLATES, HVAC GRILLES, ETC.) TO MATCH ACOUSTICAL TILE/ GYPSUM BOARD CEILING ADJACENT COLOR PRIOR TO INSTALLATION, UNLESS INDICATED OTHERWISE. 6. THE AUDIO SUBCONTRACTOR IS RESPONSIBLE FOR DESIGNATING SPEAKER LOCATIONS THROUGHOUT THE FACILITY. FOR PROPER INSTALLATION OF AUDIO EQUIPMENT, THE AUDIO SUBCONTRACTOR SHALL COORDINATE ANY PROVISIONS NECESSARY BY ALL APPLICABLE TRADES. THE SUBCONTRACTOR SHALL CUT ALL REQUIRED OPENINGS IN ACOUSTICAL TILE/ GYPSUM BOARD CEILINGS, AS REQUIRED FOR THE AUDIO SUBCONTRACTOR (VERIFY IN FIELD BY OWNER). 7. THE SUBCONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL SUBCONTRACTOR TO PROVIDE PROPER SUPPORT OR BLOCKING REQUIRED FOR ALL PENDANT MOUNTED LIGHT FIXTURE(S)/TRACK(S). 8. SPACING OF HANGERS FOR SUSPENDED CEILING MUST NOT BE MORE THAN 48" O.C. SPLAYED HANGERS MUST BE PROVIDED OR INTERMEDIATE HANGERS FROM SUPPLEMENTAL STEEL MUST BE SUPPLIED. USE #12 HANGER WIRES 48-O.C. FOR SUPPORTING THE ACOUSTICAL CEILING GRID. 9. FINISHED ACOUSTICAL TILE CEILING HEIGHT TO BE DETERMINED THROUGH FIELD OBSERVATIONS AND SET AS PERMITTED BY STRUCTURE AND MECHANICAL SYSTEMS - VERIFY WITH THE ARCHITECT PRIOR TO INSTALLATION. 10. WHERE ANY SUSPENDED ACOUSTICAL TILE CEILING ADJACENT TO A GYPSUM BOARD CEILING, THE SUBCONTRACTOR SHALL COORDINATE INSTALLATION TO PROVIDE MATCHING FINISH HEIGHTS OF EACH CEILING, UNLESS INDICATED OTHERWISE. 11. SUSPENDED ACOUSTICAL GRID SHALL BE CENTERED WITHIN EACH SPACE UNLESS INDICATED OTHERWISE BY A SPECIFIC DIMENSION OR AN INDICATED GRID STARTING POINT. 12. ELECTRICAL SUBCONTRACTOR SHALL ADJUST TRACK FIXTURES AND ADJUSTABLE DOWN LIGHTS AS PER OWNER'S AND /OR ARCHITECT'S DIRECTION. ELECTRICAL SUBCONTRACTOR SHALL PROVIDE AN ON -SITE EXPLANATION OF THE LIGHTING AND ELECTRICAL SYSTEMS TO THE OWNER. 13. AUGN SOFFITS WITH PARTITIONS AND /OR PARTITION EDGES WHERE APPLICABLE, UNLESS INDICATED OTHERWISE. 14. ALL DIMENSIONS TO BE MEASURED FROM THE FACE OF THE FINISHED PARTITIONS. 15. REFER TO SPRINKLER DRAWINGS FOR THE LOCATION OF ALL SPRINKLER HEADS AND FOR HYDRAULIC CALCULATIONS. 16. REFER TO ELECTRICAL DRAWINGS FOR FULL SPECIFICATION, CIRCUITING, DIMMING, AND WIRING. 17. PROVIDE CEILING ACCESS PANEL(S) OR DOOR(S) IN ALL GYPSUM BOARD CEILINGS AS REQUIRED FOR ACCESS TO ANY BUILDING PIPING, VALVES, VAV BOXES, ETC. (TYPICAL) 18. ELECTRICAL CONTRACTOR TO INSTALL ALL OWNER SUPPLIED LIGHTING FIXTURES. 19. ELECTRICAL CONTRACTOR TO PROVIDE J -BOXES AS REQUIRED FOR EXTERIOR SIGNAGE AND BUILDING MOUNTED WALL LIGHTING. 3. ALL DOWN AND TRACK LIGHTS ARE TO BE ON DIMMERS, FIXTURES A,B,J, AND L SPECIALTY ELECTRICAL SYMBOL DESCRIPTION SPECIFICATION AMPS /VOLTS CONTACT =- D WALL HUNG OWNER SUPPLIED N/A TBD W PHONE DRRS 12V, 20W BI -PIN HALOGEN ROCHELLE LENS 629 q DUPLEX u •E ch •ca (407) -5644 _ OUTLET jM #TC920 -625B 6" DEEP BAFFLE PAR 38 W/150 ALLOW 75W JUNO LIGHTING OIG DUPLEX OUTLET ISOLATED GROUND WATT PAR 38 LAMP 847.827.9880 013 CONTACT ROGER ANGELKORTE- JUNO LIGHTING 0 Co DOUBLE DUPLEX (847)827 -9880 OUTLET (QUAD) LIGHTOLIER: LYTECASTER RECESSED DOWN LIGHT (1) 75W MR16 GENLYTE .. +1G DBL DPLX (QUAD) 413MTX /4020MREX ROCHELLE LEWIS ISOLATED GROUND V_ T- (407) 629 -5644 ��{{,, `N' WASHING MACHINE OUTLET TBD ALLOW 4000W 2ND AVE W TOTAL QTY 1 - - - - -- � D DRYER OUTLET 800.843.1602 DUPLEX OUTLET CEILING MOUNTED LIGHTOUER: TANGENT TRACK LIGHTING SYSTEM 5OW MAX GENLYTE C TOTAL QTY: 4 LOCATIONS FX16S 12 V MR16 HALOGEN ROCHELLE LEWIS O E DUPLEX OUTLET FLOOR MOUNTED Q EL O O (407) 629 -5644 F DECORATIVE PENDANT YUGHTING: NELSON SAUCER LAMP MEDIUM 9.5 "x25 "DIA. ALLOW 75W YLIGHTING F J BOX W0 W 866.428.9289 F J BOX FLOOR MOUNTED YLIGHTING : NELSON CIGAR LAMP MEDIUM 21 "Hx11.5 "DIA. ALLOW 75W YLIGHTING REELECTED CEILING LEGEND -= SYMBOL DESCRIPTION SPECIFICATION LAMPS /FIXT. CONTACT =- a corceptua ly indeoenlnt forum RECESSED DISKUS PUCK LIGHT ARDEE: DISKUS PUCK LIGHT (1) 20W HALOGEN LAMP GENLYTE O TOTAL QTY.: VERIFY DRRS 12V, 20W BI -PIN HALOGEN ROCHELLE LENS 629 q Cn LL. C u •E ch •ca (407) -5644 _ CYLINDER CAN LIGHT jM #TC920 -625B 6" DEEP BAFFLE PAR 38 W/150 ALLOW 75W JUNO LIGHTING TOTAL QTY: VERIFY WATT PAR 38 LAMP 847.827.9880 013 CONTACT ROGER ANGELKORTE- JUNO LIGHTING 0 Co (847)827 -9880 LYTECASTER RECESSED LIGHTOLIER: LYTECASTER RECESSED DOWN LIGHT (1) 75W MR16 GENLYTE OC DOWNUGHT 413MTX /4020MREX ROCHELLE LEWIS TOTAL QTY: VERIFY V_ T- (407) 629 -5644 � o ._ CUSTOM ACRYLIC LIGHT FIXTURE TBD ALLOW 4000W 2ND AVE @1 D TOTAL QTY 1 - - - - -- 800.843.1602 TRACK UGHT LIGHTOUER: TANGENT TRACK LIGHTING SYSTEM 5OW MAX GENLYTE TOTAL QTY: 4 LOCATIONS FX16S 12 V MR16 HALOGEN ROCHELLE LEWIS O E Q EL O O (407) 629 -5644 DECORATIVE PENDANT YUGHTING: NELSON SAUCER LAMP MEDIUM 9.5 "x25 "DIA. ALLOW 75W YLIGHTING F TOTAL QTY: VERIFY W0 W 866.428.9289 DECORATIVE PENDANT YLIGHTING : NELSON CIGAR LAMP MEDIUM 21 "Hx11.5 "DIA. ALLOW 75W YLIGHTING G TOTAL QTY VERIFY < Co 866.428.9289 DECORATIVE PENDANT OXYGEN LIGHTING: MASSIMA /PENDANT 2- 615 -59 ALLOW 50OW OXYGEN LIGHTING TOTAL QTY: VERIFY 7 "DIAM. x 17 "H � 877.607.0203 H FINISH: SILVER GRAPHITE, SATIN WHITE TRIPLEX GLASS DECORATIVE PENDANT ALLUMINARE: LARGE RECTANGULAR DINING PENDANT ALLOW 50OW AU_UMINARE TOTAL QTY: VERIFY SHADE: 0 - ITE LI ZE: 26 "W X 14 'D, ' Notes WWW.ALLUMINARE.COM 866.526.7748 A20200 ABLE , 150W Drawing No. BARTOP LAMP SIENA LIGHTING: ALICE 2423 ALLOW 75W SIENA LIGHTING TOTAL QTY VERIFY 13 "H x 19 "W 408.573.7450 J 2 RECESSED DOWNUGHT BUILDING STANDARD EXTERIOR LIGHTING ALLOW 75W TERI D TO QTY: VE RECESSED CABINET LIGHT 140-BEAM, ALLOW 20W SESCO LIGHTING TOTAL QTY: 8 .2WAARITE, BRUSHED NICKEL FINISH DAN SCHULMAN O 407.629.6100 L ORA DANT B US: LIMB G COLLEC L4116, 10 ALLOW W SE GHTIN TOTA . 2 E; 7 SCH 407.629.6100 L1 DECORATIVE PENDANT BEGA /US: UMBURG COLLECTION L4117, 10OW ALLOW 75W SESCO LIGHTING TOTAL QTY: 1 SIZE: 9 -7/8" X 79L DAN SCHULMAN L2 407.629.6100 DECORATIVE PENDANT BEGS /US: UMBURG COLLECTION L4118, 10OW ALLOW 75W SESCO LIGHTING TOTAL QTY: 2 SIZE: 11 -3/4" X 79 "L DAN SCHULMAN L3 407.629.6100 DECORATIVE PENDANT BEG S• UMBURG COLLECTION L4119, 10OW ALLOW 75W SESCO UGH11NG TOTAL QTY: 1 SIZE: 13 -3/4" X 79 "L DAN SCHULMAN 407.629.6100 L4 DECORATIVE PENDANT BEG S: UMBURG COLLECTION L4341, 10OW ALLOW 75W SESCO LIGHTING TOTAL QTY: 1 SIZE: 15 -3/4" X 81L DAN SCHULMAN 407.629.6100 L5 DECORATIVE PENDANT LUMETTA 48" DRUM PENDANT ALLOW 50OW LUMETTA TOTAL QTY: 3 LUMENATE COLOR: D4 GOLD 408.573.7450 M DECORATIVE PENDANT YLIGHTING: Easy Pendant Light —W1 Grey ALLOW 20W YLIGHTING TOTAL QTY: 40 866.428.9289 0 1��Jjjjj 11111111111 111111111111 2 FLUORESCENT STRIP UGHT 6 FOOT FLUORESCENT ALLOW 20W YLIGHTING ® 0 TOTAL QTY: 2 866.428.9289 RECESSED CABINET LIGHT MP LIGHTING: LED52 1W BULB COLOR WHITE, 140BEAM, ALLOW 30W O L TOTAL QTY: 24 BRUSHED NICKEL FINISH %"ml ' 4 FLUORaqNT IUjGHT2kER : DEEP DPA2G18 32 FLUOR ENT 3) 32 BES GEN C ARA VE � VERIFY QTY (407) 629 -5644 2' X 4' FLUORESCENT GHTOUER XPXA 2'X4' LENS RECESSED FLUURESCENT 3) 3 T8 TUBES GENLYTE FL KITCHEN, STORAGE, HALL AREA XP /XA332 2 ROCHELLE LEWIS (407) 629 -5644 VERIFY QTY 2' X 4' FLUORESCENT LIGHTOLIER XPXA 2'X4' LENS RECESSED FLOURESCENT ) 32W T8 TUBES GENLYTE KITCHEN, STORAGE, HALL AR AS XA332 ROCHELLE LEWIS Y 6 � BA RY PACK 400 LUMEN OUTPUT) DELEATED - -- --- - -- TERIOR WDEPADDLEFANS DESIGN WITHIN REACH: EXTERIOR CEILING FAN - LAPA DES[ WITHIN R • EL: LAP- 42 NK NL 3 3 0 . � 2 FLATSCREEN TELEVISION PROVIDE ELECTRICAL FOR WALL MOUNT TV REFLECTED CEILING PLAN NOTES: 1. ALL QUANTITIES ARE AS SHOWN ON PLAN, CONTRACTOR MAY WANT TO ORDER ADDITIONAL AMOUNTS OF SOME FIXTURES. 2. TRACK LIGHTING AND HEADS NEED TO BE VERIFIED AS PER SITE FOR PLACEMENT AND ADJUSTMENT. 3. ALL DOWN AND TRACK UGHTS ARE TO BE ON SUDE DIMMERS. 4. DJ BOOTH EQUIPMENT AND AMP RACKS MUST BE GROUNDED TOGETHER AND ISOLATED FROM ALL OTHER POWERED EQUIPMENT. i i avercK Arck, ecli.ire Desigr, 'c. I�j4 6615 WestlwooJ e1vdlI. Suite 140 Orlando, t:LrJ, 32821 i 1 T• 2.01.351.8//8/ �. 40/.351.0254 Q: I n ro@ 1 l averi ckArck Des. com AA. 26000903 AR). Q1835 a corceptua ly indeoenlnt forum 1 i I I i i I co O co •L ca Cn LL. C u •E ch •ca I 0 O U) 0 0 Co N � O m V_ T- � o ._ � a O Q EL O O U y WWN O W0 W W < Co o Z I i N � � i I Reflected Ceiling Plan Schedule and Notes A20200 Drawing No. it