05-893-017N M L J H G F E D C A __ 2 -- I 3 Y1I 4 I_ 5 I 6 7 11 11 12 13 14 Temporary Lighting Notes 1. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLY, INSTALLATIONS AND MAINTENANCE OF TEMPORARY SERVICE, DISTRIBUTION EQUIPMENT, WIRING, LIGHTING AND POWER REQUIRED BY ALL TRADES DURING CONSTRUCTION. TEMPORARY SERVICE SHALL BE TAKEN FROM EXISTING BUILDING PANELS, TRANSFORMERS, ETC. ENERGY CHARGES FOR USAGE OF TEMPORARY SERVICE DURING CONSTRUCTION PHASE WILL BE PAID BY OWNER. LOCATE ALL TEMPORARY EQUIPMENT IN LOCATIONS WHICH WILL NOT INTERFERE WITH CONSTRUCTION. VERIFY LOCATION WITH ARCHITECT AND GENERAL CONTRACTOR PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING POWER SUPPLIES TO ALL CONSTRUCTION, STORAGE AND OFFICE TRAILER, TEMPORARY STRUCTURES, ETC. AS REQUIRED. 2. SUFFICIENT LIGHTING LEVELS SHALL BE MAINTAINED DURING THE CONSTRUCTION PHASE AS REQUIRED BY ALL TRADES FOR THE PROPER INSTALLATION FOR THEIR WORK. THERE SHALL BE SUFFICIENT OUTLETS, POWER SUPPLIES FOR SPECIAL TOOLS (SUCH AS BRICK SAWS OR WELDERS) AS REQUIRED BY ALL TRADES. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT OF ALL LIGHT BULBS AND LAMPS WHICH MAY BECOME DEFECTIVE DURING CONSTRUCTION. 3. UPON COMPLETION OF PROJECT, ALL TEMPORARY SERVICE EQUIPMENT, LIGHTING, OUTLETS, WIRING, ETC. SHALL BE REMOVED. 4. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH INSTALLATION OF TEMPORARY SYSTEM. COST OF ENERGY CONSUMPTION USED DURING CONSTRUCTION WILL BE PAID BY OTHERS. Lighting General Notes 1. UNLESS OTHERWISE NOTED, ALL LIGHTING FIXTURES AND LAMPS ARE NEW AND ARE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 2. ALL LIGHTING FIXTURES SHALL BE FURNISHED COMPLETE WITH ALL LAMPS AND WITH ALL REQUIRED MOUNTING HARDWARE AND ACCESSORIES. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO DETERMINE THE TYPE OF CONSTRUCTION INTO WHICH EACH LIGHTING FIXTURE WILL BE INSTALLED AND TO PROVIDE THE APPROPRIATE MOUNTING HARDWARE. 3. PARTS AND FITTINGS SHOWN ON DRAWINGS FOR INSTALLATION OF TRACK LIGHTING ARE INTENDED TO BE DIAGRAMMATIC ONLY TO INDICATE REQUIRED INSTALLATION AND LAYOUT OF LIGHT TRACK. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL PRECISE FITTINGS, PARTS, ETC. AS REQUIRED BY FIELD CONDITIONS TO PROVIDE REQUIRED INSTALLATION. 4. SEE LIGHT FIXTURE SCHEDULE ON SHEET E.301. 1 1 2 1 3 V. 5 $ GHTING PLAN �' 1 /4 =1 —0 t6' THIN SET CERAMIC TILE FLOORING ON LANDLORD'S CONCRETE SUB - FLOOR. - PROVIDE FOR A GENTAL CURVE IN THE CONDUIT FROM THE SLAB TO THE <' -- CASHWRAP. •• .. ' . GENERAL CONTRACTOR TO BE RESPONSIBLE ,. :' • ' • •: FOR SAW CUTTING OF TRENCH IN EXISTING CONCRETE SLAB. RE -FILL SAW CUT WITH g •.• ': J r MINIMUM 4000 PSI CONCRETE. PRIOR TO 2 1 2' d 4• a START OF ANY CUTTING COORDINATE SIZE, LOCATION, AND SCHEDULING WITH THE MALL MANAGEMENT. t4, ... +. :' NEW 1 1/2- EMPTY a Q 4 a CONDUIT. Q r— EXISTING LANDLORD'S CONCRETE Q SUB- FLOOR. 7 w TRENCH DETAIL *..2Y0 NTS E it 11 MPE Systems Engineering 750 Brooksedge Blvd. Westerville, OH 43081 614.818.2323 Fax: 614.818.2337 eoldenburgOm— corporations. corn 17 1524 Delancey Street Philadelphia, PA 19102 www.8P93.aom t. 215.735.1524 f. 215.735.4949 Lighting Plan Legend APPROVED BY MIAMI -DADE COUfff FIDE DEPARTAIE#T SPI�__B1�6. PERW V#ATER NkMN ED(TW610N DAT Y Elf -7 05.26.05 FIRE REVIEW COMMENTS 1 04.19.05 ISSUED FOR TENANT AND BUILDING DEPARTMENT N/A REVIEW Date Issue Rev. No. U p Against The Wall FIELD VERIFY ALL CONDITIONS Space No. A -10 DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE The Shops at Sunset Place SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND South Miami, FL MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER LIGHTING Prof. No.: 0504005 PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER Plan J •'•• T IF'. AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT �t : �,Ai. �0'••; i!''� CONTRACTORS COST. ++ C, BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL -TS • NTq�4 r- CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE '0! ;� ' Q / COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH �-�'• �l :1; J GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. fic+' 0 U THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF 5 ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN L INTENT. 12 13 14 15 16 17 Spa SURFACE MOUNTED LIGHT TRACK IM7H FLUORESCENT AND INCANDESCENT TRACK HEADS. • INCANDESCENT PENDANT D004L IGHHT 0 RECESSED AD.ILISTALE INCANDESCENT DOM AKIN 0 12SWo FLUORESCENT DDIIINLIGHT 0 (X) E)OS71NG DOMINUGHT M REMNN ORECESSED FLUORESCENT LIGHT FIXTURE. RECD FLUORESCENT TM7H EMERMCY/ NIGHT LIGHT. o SURFACE OR PENDENT FLUORESCENT STRIP LIGHT FDQURE. o SURFACE OR PENDENT FLUORESCENT STRIP LIGHT FDCRM . VA7H EMERGENCY/NIGHT LIGHT. ILLUTANA70 EDT SIGN (CMJN0 ILLUMINATED EXT SKIN (WALL MOUNTED). 5 EMERGENCY LIGHT IMiN BUILT —IN BATTERY PACK ® CEILING EXHAUST FAN APPROVED BY MIAMI -DADE COUfff FIDE DEPARTAIE#T SPI�__B1�6. PERW V#ATER NkMN ED(TW610N DAT Y Elf -7 05.26.05 FIRE REVIEW COMMENTS 1 04.19.05 ISSUED FOR TENANT AND BUILDING DEPARTMENT N/A REVIEW Date Issue Rev. No. U p Against The Wall FIELD VERIFY ALL CONDITIONS Space No. A -10 DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE The Shops at Sunset Place SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND South Miami, FL MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER LIGHTING Prof. No.: 0504005 PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER Plan J •'•• T IF'. AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT �t : �,Ai. �0'••; i!''� CONTRACTORS COST. ++ C, BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL -TS • NTq�4 r- CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE '0! ;� ' Q / COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH �-�'• �l :1; J GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. fic+' 0 U THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF 5 ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN L INTENT. 12 13 14 15 16 17