05-893-013
1 I 2 I 3 I 4 I 5 MIN 1 -1/4" DRAIN AIR DUCT FROM PAN TO LANDLORD APPROVED RECEPTOR. RETURN TUBE AUXILIARY FLOAT SHUT -OFF MIN. 1 -1/4" COPPER SWITCH. A.H.U. DRAIN TO LANDLORD APPROVED RECEPTOR. SMOKE DETECTD AUXILIARY DRAIN PAN UNDER A.H.U. MIN. 6" LARGER THAN A.H.U. & 6" DEEP, SEAL ALL SEAMS WATERTIGHT CONDENSATE TRAP DEPTH TO BE 1 1/2 TIMES UNIT OPERATING STATIC PRES- SURE (MIN. 2 ") MECHANICAL CODED NOTES O CONTRACTOR SHALL FURNISH AND INSTALL A PROGRAMMABLE THERMOSTAT AT 48 IN. ABOVE FINISHED FLOOR. COORDINATE EXACT LOCATION WITH TENANT. THE ENTIRE CONTROL SYSTEM SHALL BE PROVIDED COMPLETE IN EVERY RESPECT BY THE MECHANICAL CONTRACTOR. THE CONTROL SYSTEM SHALL INCLUDE THE FOLLOWING COMPONENTS AND FUNCTIONS: 1. PROGRAMMABLE THERMOSTAT 2. 2 -WAY CHW VALVE 3. ELECTRIC HEAT CONTROL 4. SET BACK MODULE, TIME CLOCK AND HUMIDITY CONTROL MODULE. PROVIDE HONEYWELL DDC CONTROLLER W/ HONEYWELL SYSTEM CONTROLLER TO INTERFACE WITH LANDLORD SYSTEM AND PROVIDE A WALL MOUNTED SENSOR WITH TEMPERATURE AND HUMIDITY FUNCTIONS. SEE LANDLORD CRITERIA DRAWINGS. COORDINATE EXACT REQUIREMENTS WITH LANDLORD PRIOR TO BID. O2 AHU -1: (NEWT CONTRACTOR SHALL FURNISH AND INSTALL A CHILLED WATER AIR HANDLING UNIT AS SHOWN ON PLANS . SEE CHILLED WATER BLOWER COIL UNIT SCHEDULE. UNIT SHALL BE INSTALLED ON EXISTING PLATFORM STRUCTURE. THE HVAC CONTRACTOR SHALL PROVIDE ADDITIONAL STEEL AS REQUIRED TO MAINTAIN THE LOAD BEARING CAPACITY OF THE EXISTING STRUCTURE. COORDINATE STEEL REQUIREMENTS WITH THE LANDLORD. ALL UNITS TO BE MOUNTED WITH COMBINATION IN -LINE SPRING/ RUBBER SHEAR VIBRATION ISOLATORS. FACTORY INSTALLED ACCESSORIES: LEFT HAND COIL AND LEFT HAND FAN ACCESS SUSPENSION CHANNELS 2" FLAT FILTER SECTION CONTRACTOR FURNISHED AND INSTALLED ACCESSORIES: THREE SETS STANDARD 2" AIR FILTERS CONTRACTOR TO REPLACE FILTERS JUST PRIOR TO AIR BALANCE AND ONCE AGAIN AFTER FINAL STORE CLEANING IS COMPLETE. O3 HVAC CONTRACTOR SHALL REUSE PIPING FROM THE EXISTING LANDLORD WATER TAPS TO THE AIR HANDLING EQUIPMENT AS SHOWN ON PLANS, RECONNECT TO NEW AHU AND PROVIDE PIPING AS REQUIRED. FIELD VERIFY EXACT LOCATION OF LANDLORD'S PIPING PRIOR TO INSTALLATION. PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS AND LANDLORD'S SYSTEM REQUIREMENTS. SEE LANDLORD'S MECHANICAL CRITERIA DRAWINGS. CONTRACTOR SHALL FURNISH ALL VALUING AND ACCESSORIES AS SHOWN ON PLANS OR AS REQUIRED TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. REFER TO COIL PIPING DIAGRAMS. CONTRACTOR SHALL VERIFY SYSTEM PRESSURE AND WATER TEMPERATURE BEFORE INSTALLING SYSTEM. CONTRACTOR SHALL REPORT TO THE CONSTRUCTION MANAGER ANY DISCREPANCY THAT WILL CAUSE THE SYSTEM NOT TO PROVIDE THE REQUIRED OUTPUT SO ADJUSTMENTS CAN BE MADE. FAILURE OF THE CONTRACTOR TO NOTIFY THE TENANT'S CONSTRUCTION MANAGER WILL PLACE THE COST FOR ANY ADDITIONAL WORK TO BE BORNE BY THE CONTRACTOR. ® SMOKE DETECTOR IN AIR DUCT TO SHUT DOWN SUPPLY FAN WHEN ACTIVATED. SMOKE DETECTOR SHALL BE FURNISHED BY MECHANICAL CONTRACTOR AND INSTALLED BY ELECTRICAL CONTRACTOR. DETECTOR TO BE COMPATIBLE WITH LANDLORD'S FIRE ALARM SYSTEM, COORDINATE EXACT REQUIREMENTS WITH LANDLORD. LANDLORD'S CONTRACTOR TO MAKE FINAL CONNECTION TO LANDLORD'S FIRE ALARM SYSTEM. O MECHANICAL CONTRACTOR SHALL INSTALL CONDENSATE DRAINS FROM THE AHU UNIT AS SHOWN ON PLANS. MINIMUM DRAINS TO BE 3/4" OR AS SPECIFIED ON PLANS. CONDENSATE DRAIN SIZE TO BE TRAPPED WITH A TRAP DEPTH OF 1.5 X UNITS TOTAL STATIC PRESSURE. DRAINS SHALL BE EXTENDED TO FLOOR DRAIN IN RESTROOM. PIPE AND FITTINGS SHALL BE COPPER W/ WROUGHT FITTINGS UNLESS NOTED OTHERWISE. SEE DETAIL, SHEET M.201. © ALL DUCTWORK SHALL BE RAN TIGHT TO STRUCTURE. CONTRACTOR SHALL COORDINATE DUCT RUNS WITH EXISTING CONDITIONS, LIGHTING LAYOUT AND OTHER PLENUM OBSTRUCTIONS. 0 SUPPLY AND RETURN DUCT CONNECTIONS TO AHU SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING WITH FLEXIBLE DUCT CONNECTIONS AT UNIT AND THEN TRANSITIONED TO THE SIZES SHOWN. ® ROUTE OUTDOOR AIR DUCT TO NEW UNIT FROM LANDLORD MAIN. FIELD VERIFY EXACT LOCA11ON AND REQUIREMENTS WITH LANDLORD BEFORE STARTING WORK. gO MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCE FOR ACCESS TO AIR HANDLING UNIT. 10 THE MECHANICAL CONTRACTOR TO CONNECT TO EXISTING DUCTWORK AS SHOW. PROTECT DUCT OPENING FOR REMAINDER OF DEMOLITION AND CONSTRUCTION FOR FUTURE DUCT CONNECTION 11 EXISTING PLUMBING FIXTURES, WATER METER, PIPING, WATER HEATER, EXHAUST FAN, ETC. TO BE REUSED. ALL FIXTURES SHALL BE CLEANED AND LEFT IN LIKE NEW CONDITION. REPLACE FLUSH VALVES OR TANK FLOAT AND WATER CONTROL DEVICES IR REQUIRED. VERIFY PROPER OPERATING CONDITION OF WATER HEATER. VERIFY EXHAUST FAN AND DUCTWORK TO BE IN PROPER, LEAKFREE OPERATING CONDITION, REPAIR OR REPLACE AS REQUIRED. FIELD VERIFY CONDITION OF ALL FIXTURES AND EQUIPMENT AND COORDINATE REPLACEMENT AS REQUIRED WITH TENANT CONSTRUCTION MANAGER. 1 1 2 1 3 1 4 SAMPLING TUBE 6 1 7 SIMON MALL PROPERTY NOTES 1. COORDINATE DISCREPANCIES BETWEEN DOCUMENTS AND FIELD CONDITIONS WITH THE TENANT OR HIS AUTHORIZED AGENT. COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTION AND TESTING OF ALL U11UTIES OR INTERFACED SYSTEMS WITH THE LANDLORD'S FIELD REPRESENTATIVE. 2. NO COMPONENTS MAY BE ABANDONED IN PLACE. ALL COMPONENTS THAT ARE NOT REUSED MUST BE REMOVED. 3. PROVIDE ACCESS FOR ALL LANDLORD AND TENANT COMPONENTS REQUIRING PERIODIC INSPECTION AND SERVICE THAT ARE LOCATED WITHIN THE SPACE OR REQUIRE ACCESS THROUGH THE SPACE. INDICATE ACCESS PANEL LOCATIONS FOR ALL DEVICES ON THE PLANS. LABEL ACCESS DOORS AND PANELS OR CEILING TILES, RETURN REGISTERS OR DIFFUSERS UTILIZED FOR ACCESS WITH THE NAME OF THE HIDDEN COMPONENT(S). DEMONSTRATE ACCESS TO ALL HIDDEN COMPONENTS FOR THE LANDLORD'S FIELD REPRESENTATIVE PRIOR TO OCCUPANCY. 4. FILTER MEDIA SHALL BE UTILIZED TO PROTECT ALL RETURN OPENINGS DURING CONSTRUCTION. 5. SCHEDULE BALANCING WITH THE LANDLORD'S FIELD REPRESENTATIVE. PROVIDE A COPY OF THE APPROVED TEST AND BALANCE REPORT TO THE LANDLORD. 6. THE TENANT SHALL DIRECTLY EMPLOY THE LANDLORD DESIGNATED CONTRACTOR TO PERFORM ALL SPRINKLER MODIFICATIONS. SYSTEM MODIFICATIONS SHALL BE SCHEDULED IN ADVANCE WITH THE LANDLORD'S FIELD REPRESENTATIVE. THE SPRINKLER SYSTEM SHALL BE FULLY CHARGED AND OPERATIONAL WHEN THE CONTRACTOR IS OFF THE SITE. 7. NOTE: CONTRACTOR SHALL VERIFY THAT NO PVC EXISTS IN THE PLENUM SO THAT IT IS SUITABLE TO BE USED FOR RETURN AIR. 8. NOTE: PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY, THE AIR SYSTEM BALANCING AND HYDRONIC SYSTEM BALANCING SHALL BE PERFORMED. PROVIDE BALANCING DEVICES IN ACCORDANCE WITH CITY CODES AND ORDINANCES. DRAIN P CHWR O ' O CHWS S I 9 I 10 I 11 1" ACCOUSTICAL LINING — — — — — — — — — — — — — — -- L C___ SQUARE OR RECTANGULAR DUCT AIR FLOW ------------------------ 7 CONICAL OR BELLMOUTH SPIN - IN FITTING, SEAL AIRTIGHT W/ MASTIC VOLUME DAMPER, LOCATE ABOVE ACOUSTICAL CEILING OR — — — OTHER ACCESSIBLE LOCATION. sEAL WITH MASTIC AND DUCT TAPE 1" WRAPPED ROUND RIGID DUCT ' EXIST. BAR JOISTS OR I EXIST. BEAMS. SEE PLAN. CU Au 518"* A36 ROD DOUBLE NUT O CO. WELD NUTS TO ROD AFTER UNIT IS SET. (TYP.) LL 11 L '-- DOUBLE NUT & SPRING ISOLATOR O AHU'S SUSPENSION BRACKET. WELD NUTS TO ROD AHU SUPPORT DETAIL AFTER UNIT IS SET. (rM.) E N1 AHU SUPPORT HANGER SHALL BE SPACED PER AHU MANUFACTURER'S RECOMMENDATIONS (4' -0" MAX.) OUTSIDE AIR REQUIREMENTS oo° SECOND LETTER: D- DIFFUSER R- REGISTER G- GRILLE "A" METALESCENT ALUM. BAKED ENAMEL 2 CATALOG NUMBERS REFER TO TiTUS AIR DEVICES. "B" ETCHED FINISH WITH CLEAR FINISH OR ANODIZED 'C" 25 STANDARD WHITE 3.1,2.3. AND 4-WAY AIR DEVICES ARE DETERMINED BY "D" STANDARD OFF WHITE FINISH G.C. TO FIELD PAINT DIRECTIONAL ARROWS ON DRAWINGS. TO MATCH CEILING OR WALLS ASHRAE 82 -1989 OPPOSED BLADE "B" RADIAL OPPOSED BLADE "B" LAY IN MOUNTING. PROVIDE WITH PLASTER "C" BUTTERFLY FOR DRYWALL CEILING MOUNTING "C" LAY -IN FRAME FOR T -BAR CEILING SIZE BOOR OUTSIDE AIR ACCESSORIES ACTUAL SYMBOL ROOM PURPOSE AREA REQUIREMENTS REMARKS SYSTEM �� our" AIR REMARKS SO. FT: I � I JS A -71771777. ;-A CFM PER cm CFM MOD. NECK _ - DUCT STEEL ALUM. SO. FT. READ. PER UNIT SD -1 SALES 2883 0.30 804,9 AHU -1 870 • N —SALES 434 0.15 85.1 B SD -2 TOTAL 2ex24" Tom TOTAL 870 b OO 1i o i' O. O O ' I 1 "o O Y STRAINER LINE SIZE WITH DRAIN VALVE (1" MIN) I I I I O ECCENTRIC REDUCER LINE COIL CONN 101 I ( O 2 TWO WAY ELECTRONIC CONTROL VALVE ( � I I I I ® 314" GATE VALVE 1 Imo` I IO AUTOMATIC AIR VENT FLOAT 1 I SIZE 3/4" SARCO TYPE 13 W 7 I 6 O GATE VALVE LINE SIZE I � I I O PRESSURE GAUGE WITH COCK 8 I (0-150 PSIG) ASHCROFT #100 G 0 I I ® THERMOMETER IN WELL (0-100 DEG F) I I O BALANCING VALVE BELL do GOSSETT LINE SIZE IQ UNION OR FLANGE LINE SIZE If • I v TO APPROVED DRAIN PROVIDE AIR GAP SEE LANDLORD'S MECHANICAL CRITERIA DRAWINGS FOR ADDITIONAL INFORMATION. 5 1 6 7 12 1 13 I 14 TO S.A. MAIN INSULATED ROUND DUCT VOLUME DAMPER FLEXIBLE CONNECTION (MAX. 5 FT.) ---' THERMAL INSULATING BLANKET WHERE REQUIRED. —1 i f SUPPLY AIR f DIFFUSER i STRAP CLAMP (TYPICAL) FIRE DAMPER WHERE REQUIRED DRYWALL CEILING TER FRAME RESPONSIBILITY oo° SECOND LETTER: D- DIFFUSER R- REGISTER G- GRILLE "A" METALESCENT ALUM. BAKED ENAMEL 2 CATALOG NUMBERS REFER TO TiTUS AIR DEVICES. "B" ETCHED FINISH WITH CLEAR FINISH OR ANODIZED 'C" 25 STANDARD WHITE 3.1,2.3. AND 4-WAY AIR DEVICES ARE DETERMINED BY "D" STANDARD OFF WHITE FINISH G.C. TO FIELD PAINT DIRECTIONAL ARROWS ON DRAWINGS. TO MATCH CEILING OR WALLS 4.DAMPERS SHALL BE OPERABLE FROM FACE e. BORDER STYLE - "A" "A" SURFACE MOUNTED OPPOSED BLADE "B" RADIAL OPPOSED BLADE "B" LAY IN MOUNTING. PROVIDE WITH PLASTER "C" BUTTERFLY FOR DRYWALL CEILING MOUNTING "C" LAY -IN FRAME FOR T -BAR CEILING SIZE MOUNTING MATERIAL ACCESSORIES BORDER SYMBOL CATALOG � FINISH REMARKS I � I JS A -71771777. ;-A MOD. NECK _ - DUCT STEEL ALUM. DPR. STYLE SD -1 OMNI 2ex24" 10 "0 • • C B B SD -2 OMNI 2ex24" 10 "0 • • C B C SD -3 OMNI 12 "x12" 6 "0 • • C B A SD -4 FL -10 4' LENGTH 2" SLOT 8 " 0 • • C B B DE WITH YOUN S GULATOR AND BOWDEN CONTROLS RG -1 25RL 24 "x12" 2eX10" • • C B RG -2 25RL 12 "x12" 10 "X10" • • C C RG -3 25RL 2ex12" 22 "X10" • • C C F2 ka: "' V" L. 311110 L THIS SCHEDULE IS INTENDED AS A wQU1IW REFERENCE. ALL ITEMS USTED HERE ARE SPECM AND DETALED ON 14M DRAWING& F THE 0ON7RAC11OR ENCOUNTERS M31S THAT ARE CONTRADICTORY THEN IT IS HIS RESPONSIBILITY TO INFORM TENAN7*S CONSTRUCTION MANAGER SO THAT IH ITEMS CAN BE CLARIFIED THE CONTRACTOR. AIR DISTRIBUTION DEVICES NOTES : 1. SYMBOL KEY - FIRST LETTER: S- SUPPLY R- RETURN E- EXHAUST 5. FINISH - SECOND LETTER: D- DIFFUSER R- REGISTER G- GRILLE "A" METALESCENT ALUM. BAKED ENAMEL 2 CATALOG NUMBERS REFER TO TiTUS AIR DEVICES. "B" ETCHED FINISH WITH CLEAR FINISH OR ANODIZED 'C" 25 STANDARD WHITE 3.1,2.3. AND 4-WAY AIR DEVICES ARE DETERMINED BY "D" STANDARD OFF WHITE FINISH G.C. TO FIELD PAINT DIRECTIONAL ARROWS ON DRAWINGS. TO MATCH CEILING OR WALLS 4.DAMPERS SHALL BE OPERABLE FROM FACE e. BORDER STYLE - "A" "A" SURFACE MOUNTED OPPOSED BLADE "B" RADIAL OPPOSED BLADE "B" LAY IN MOUNTING. PROVIDE WITH PLASTER "C" BUTTERFLY FOR DRYWALL CEILING MOUNTING "C" LAY -IN FRAME FOR T -BAR CEILING SIZE MOUNTING MATERIAL ACCESSORIES BORDER SYMBOL CATALOG � FINISH REMARKS MOD. NECK _ - DUCT STEEL ALUM. DPR. STYLE SD -1 OMNI 2ex24" 10 "0 • • C B B SD -2 OMNI 2ex24" 10 "0 • • C B C SD -3 OMNI 12 "x12" 6 "0 • • C B A SD -4 FL -10 4' LENGTH 2" SLOT 8 " 0 • • C B B DE WITH YOUN S GULATOR AND BOWDEN CONTROLS RG -1 25RL 24 "x12" 2eX10" • • C B RG -2 25RL 12 "x12" 10 "X10" • • C C RG -3 25RL 2ex12" 22 "X10" • • C C VERIFY ALL CONDITIONS 8 8 1 10 1 11 IN FIELD ,2 PRIOR TO BID 13 1 14 M— Retail Engineering, Inc. MPE Systems Engineering 750 Brooksedge Blvd. Westerville, OH 43081 614.818.2323 Fax: 614.818.2337 eolden burgOrn— corporations.com 17 1524 Delancey Street Phladelphla, PA 19102 www.apg3.com t. 215.735.1524 f. 215.735.4949 V APR 1 0 "2005 04.19.05 ISSUED FOR TENANT AND BUILDING DEPARTMENT N/A REVIEW Date Issue Rev. Na U p Against The Wall Space No. A -10 The Shops at Sunset Place South Miami, FL Mechanical 11 NO" : 11 Details EGO N M L T J H G F E E C 0 A 0 Q. 15 16 1 17