05-893-006N M .L K .J I G F E: D1 p 1/4' =19-0' 5 B A 2 N Reflected Ceiling Plan I Liaht Fixture Schedule TYPE DESCRIPTION MANUR RECESSED 2'X2' FLUORESCENT LIGHT A FIXTURE, 'X2' �- RECESSED 2 FLUORESCENT AA EMERGENCY LIGHT FIXTURE, METALUX B INCANDESCENT LIGHT TRACK FIXTURE JUNO BI 1 LIGHT TRACK JUNO G RECESSED INCANDESCENT LIGHT JUNO MODEL No, FIXTURE REMARKS AND FITTINGS FURNISH AND INSTALL HANGERS AN FITTINGS AS REQUIRED FOR A COMPLETE INSTALLATION, GI RECESSED FLUORESCENT LIGHT JUNO CH240 -EI WITH EMERGENCY LIGHT FEATURE FIXTURE F D FLUORESCENT LIGHT TRACK FIXTURE JUNO E SURFACE MOUNTED STRIP SIMKAR FITTING ROOM LIGHT SCONCE FLUORESCENT LIGHT FIXTURE 'TABLEAU' ADJUSTABLE FLUORESCENT - TABI25/PC/277 11 5 0 7 9 EXISTING GYP, BD, CEILING AT f9' -10 1/2" A.F.F. REPAIR \ AS NECESSARY FOR "LIKE -� i MODEL NO, LAMP 2EP3GAX- 25X4OS441 -277Y BX40 40W BIAX 24" 2EP3GAX- 25X4OS441- 277V -EL4 BX40 4OW BIAX 24" t689WN 75W PAR-10 AT 9'-O" A,F,F PI REMARKS PROVIDE 16 CELL SILVER PARABOLIC LENS, PROVIDE 16 CELL SILVER PARABOLIC LENS, FURNISH AND INSTALL WHITE, ONE CIRCUIT TRACK COMPLETE WITH ALL FITTINGS, HANGERS, ETC., AS REQUIRED TO PROVIDE T4,T8, TI2 - WH (WHITE) NOT APPLICABLE COMPLETE INSTALLATION. AT POINTS DESIGNATED "CIRCUIT ONE - CIRCUIT TRAC BREAK ", USE TRACK CENTER FEED KIT TO CONNECT TRACK SECTIONS IN OPPOSITE DIRECTIONS MECHANICALLY, BUT NOT ELECTRICALLY, PROVIDE LENGTHS AS NECESSARY TO OBTAIN PROPOSED CONFIGURATION, TC954 -699C 1 130- V60W -HIR -NFL CV8- 126/32/42T CF42TIF-830 8200 -WH TBX39E- WW-SL39 (2) F395XSPX30 TRACK MOUNT WITH ELECTRONIC BALLAST, CW240 -El (2) F3278/TL530 FURNISH AND INSTALL HANGERS AND FITTINGS AS REQUIRED 3000K, 85w--RI (PHILLIPS) FOR A COMPLETE INSTALLATION, 1 1 ? I 3 I 4 I 5 I 6 7 GYP, BD, CEILING AT 10' -4 1/2" A,F,F, PI 10 / Ok OF CASHWRAP, A,C,T, AND CEILING SOFFIT LAYOUT (WORKING PT,) 11 12 13 CENTER SURFACE Mn IMT;=M I Ir�WT MOUNTED LIGHT ~ TRACK ON GYP, BD, FASCIA 14 PROVIDE FLUSH GYP, BD. ACCESS DOOR FOR SENSORMAT EQUIPMENT WITH ALL CONCEALED HARDWARE, USE MILCOR "AT" SERIES OR EQUAL, PI I V7 e 0- TYPE DESCRIPTION MANUF MODEL No, LAMP REMARKS AND FITTINGS FURNISH AND INSTALL HANGERS AN FITTINGS AS REQUIRED FOR A COMPLETE INSTALLATION, INCANDESCENT TRACK HEADS, SURFACE MOUNTED STRIP FLUOR. EMERGENCY LIGHT FIXTURE SIMKAR CH240 -EI WITH EMERGENCY LIGHT FEATURE (2) F32T8/TL 3000K, 85CRI (PHILLIPS) F STRIP FLUORESCENT LIGHT FIXTURE SIMKAR CH220TS (2) 2OW TI2 30OOK, 85C-RI (PHILLIPS) SURFACE MOUNT IN POCKET ABOVE THREE -WAY MIRROR, PROVIDE I "XI" PARABOLIC SILVER DIFFUSER AT 8'-0" A,F,F, REFER TO DETAIL, FI FITTING ROOM LIGHT SCONCE ALKCO 'TABLEAU' ADJUSTABLE FLUORESCENT - TABI25/PC/277 (1) F25T8 O RECESSED FLUORESCENT G PENDANT HUNG INCANDESCENT LIGHT FIXTURE FORECAST LIGHTING ILIGHTOLIER) HOPE MINI F487 -36 (1) MED &OW MOUNT FIXTURE VERTICALLY ALONG EITHER SIDE OF MIRROR J RECESSED FLUORESCENT COVE FIXTURE ALKCO MINI -COVE T5 STRIP MINATURE FLUORESCENT MCS SERIES MC9128 I/FS5T5 4 FT, NOMINAL LENGTH EX -I EDGE LIT EXIT SIGN SURE -LITES EXC- 5- 1- 70 -WW-R -120 (2) FSTS FLUORESCENT PROVIDE CHEVRON AS INDICATED ON REFLECTED CEILING PLAN EX -2 EXIT SIGN SURE -LITES PLX- 6200 -RP 1(2) 5W F5TT FLUORESCENT PROVIDE CHEVRON AS INDICATED ON REFLECTED CEILING PLAN 8 1 q 1 1 1 1 1 1 19 1 17 1 1 15 IM-ReW Evirwring, Inc. WE SysWn 0M 760 &0*0CI P BArd. WMbWA* 01i 4=1 614.0182329 Falc 614.818.2337 17 N 1524 Delancey Street Philadelphia, PA 19102 www.spg3.com t 215.735.1524 M f. 215.735.4949 Reflected Ceiling Plan Legend L SURFACE MOUNTED LIGHT Time" TRACK WITH FLUORESCENT AND INCANDESCENT TRACK HEADS, ® INCANDESCENT PENDANT DOWNLIGHT O RECESSED ADJUSTABLE INCANDESCENT DOWNLIGHT O RECESSED FLUORESCENT DOWNLIGHT K EXISTING DOWNLIGHT TO lX) REMAIN O RECESSED FLUORESCENT LIGHT FIXTURE. RECESSED FLUORESCENT WITH EMERGENCY/NIGHT LIGHT, SURFACE OR PENDENT FLUORESCENT STRIP LIGHT FIXTURE, J ® SURFACE OR PENDENT FLUORESCENT STRIP LIGHT FIXTURE WITH EMERGENCY/NIGHT LIGHT, ® ILLUMINATED EXIT SIGN (CEILING MOUNTED), ILLUMINATED EXIT SIGN (WALL MOUNTED), 4F6 EMERGENCY LIGHT WITH BUILT -IN BATTERY PACK, ® RECESSED AIR DIFFUSER H Q SEMI-RECESSED SPRINKLER HEAD ® EXISTING SPRINKLER HEAD TO REMAIN a FULLY CONCEALED TYPE SPRINKLER HEAD m RETURN AIR GRILL ® CEILING EXHAUST FAN G General Notes GFIR A. EXTEND EXISTING SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13: THE STATE AND LOCAL FIRE MARSHALL'S OFFICE: THE LANDLORD'S INSURANCE COMPANY AND TENANT'S INSURANCE CARRIER, B. COORDINATE HEAD LOCATIONS WITH THE REFLECTED CEILING PLAN AND THE DUCT DISTRIBUTION SYSTEM ABOVE, PREPARE A DRAWING OF THE FIRE PROTECTION/SPRINKLER LAYOUT; AND, UPON CONCURRENCE BY BOTH THE LANDLORD F AND TENANT, OBTAIN ALL REQUIRED APPROVALS AND CERTIFICATES EVIDENCING SAME, REFER TO SPECIFICATIONS FOR ADDITIONAL CRITERIA, ACCM PANELS A. PROVIDE PAINTED FLUSH METAL CEILING ACCESS DOORS, FOR GYP. BOARD CEILING AS REQUIRED 13Y " ABOVE CEILING " EQUIPMENT, B. GENERAL CONTRACTOR TO SUBMIT SKETCH OF CEILING ACCESS DOOR LOCATIONS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION, ACOLI CAL L4Y4N CE1l M A. PROVIDE A 2'X2' LAY -IN TILE CEILING AND COMPLIMENTARY METAL GRID SUPPORT IN THE SALES AND FITTING ROOM AREAS AND A 2'X4' LAY -IN ;TILE CEILING AND METAL GRID IN THE STOCK ROOM AREA, REFER TO THE FINISH SCHEDULE, SHT, A,301, FOR E ADDITIONAL INFORMATION, B. PAINT ALL CEILING GRILLS, DIFFUSERS, ETC, TO MATCH CEILING, A00"10NAL REWUIRIEME t3 A, BATTERY PACKS FOR EXIT AND EMERGENCY LIGHTS MUST BE REMOTE OR RECESSED, PAINT EXPOSED SURFACES TO MATCH ADJACENT FINISH. B. SPRINKLER HEADS IN STOREFRONT WINDOW AND IN HARD SURFACE CEILINGS MUST BE CONCEALED TYPE, HEADS IN SALES AREA ACOUSTIC CEILING TILE MUST BE RECESSED TYPE AND CENTERED IN TILE, C. DO NOT MAKE ANY ATTACHMENTS TO THE LANDLORD'S ROOF DECK OR SOFFIT, D. USE OF WOOD ABOVE CEILING IS NOT PERMITTED, USE NONCOMBUSTIBLE FRAMING MEMBERS. E ALL WOOD MEMBERS USED FOR PURPOSES OF BACKING AND BLOCKING IN AN p APPROVED MANNER SHALL BE FIRE RETARDANT TREATED, R PROVIDE APPROVED EXIST SIGNS INSTALLED AT ALL REQUIRED EXITS AND WHERE OTHERWISE NECESSARY IN ORDER TO INDICATE THE DIRECTION OF EGRESS, NO POINT SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN, EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED, 05,26,05 FIRE REVIEW COMMENTS Q 04,19,05 ISSUED FOR TENANT AND BUILDING DEPARTMENT REVIEW Date Issue Rev. No. Up Against The Wall Space No. A -10 The Shops at Sunset Place South Miami, FL Reflected Proj. No.: 5016.00 �* g C • 1 Plan QqD' a ^ GN5016 \CDp10t5\A- 2O1,ckug 1r+ 1G 1-7