Reflected Ceiling Plan
I Liaht Fixture Schedule
TYPE DESCRIPTION MANUR
RECESSED 2'X2' FLUORESCENT LIGHT A FIXTURE, 'X2' �-
RECESSED 2 FLUORESCENT
AA EMERGENCY LIGHT FIXTURE, METALUX
B INCANDESCENT LIGHT TRACK FIXTURE JUNO
BI 1 LIGHT TRACK
JUNO
G
RECESSED INCANDESCENT LIGHT
JUNO
MODEL No,
FIXTURE
REMARKS
AND FITTINGS FURNISH AND INSTALL HANGERS AN FITTINGS AS REQUIRED
FOR A COMPLETE INSTALLATION,
GI
RECESSED FLUORESCENT LIGHT
JUNO
CH240 -EI WITH EMERGENCY
LIGHT FEATURE
FIXTURE
F
D
FLUORESCENT LIGHT TRACK FIXTURE
JUNO
E
SURFACE MOUNTED STRIP
SIMKAR
FITTING ROOM LIGHT SCONCE
FLUORESCENT LIGHT FIXTURE
'TABLEAU' ADJUSTABLE
FLUORESCENT - TABI25/PC/277
11
5
0
7
9
EXISTING GYP, BD, CEILING
AT f9' -10 1/2" A.F.F. REPAIR \
AS NECESSARY FOR "LIKE -�
i
MODEL NO, LAMP
2EP3GAX- 25X4OS441 -277Y BX40 40W BIAX
24"
2EP3GAX- 25X4OS441- 277V -EL4 BX40 4OW BIAX
24"
t689WN 75W PAR-10
AT 9'-O" A,F,F
PI
REMARKS
PROVIDE 16 CELL SILVER PARABOLIC LENS,
PROVIDE 16 CELL SILVER PARABOLIC LENS,
FURNISH AND INSTALL WHITE, ONE CIRCUIT TRACK COMPLETE WITH
ALL FITTINGS, HANGERS, ETC., AS REQUIRED TO PROVIDE
T4,T8, TI2 - WH (WHITE) NOT APPLICABLE COMPLETE INSTALLATION. AT POINTS DESIGNATED "CIRCUIT
ONE - CIRCUIT TRAC BREAK ", USE TRACK CENTER FEED KIT TO CONNECT TRACK
SECTIONS IN OPPOSITE DIRECTIONS MECHANICALLY, BUT NOT
ELECTRICALLY, PROVIDE LENGTHS AS NECESSARY TO OBTAIN
PROPOSED CONFIGURATION,
TC954 -699C 1 130- V60W -HIR -NFL
CV8- 126/32/42T CF42TIF-830
8200 -WH
TBX39E- WW-SL39 (2) F395XSPX30 TRACK MOUNT WITH ELECTRONIC BALLAST,
CW240 -El (2) F3278/TL530 FURNISH AND INSTALL HANGERS AND FITTINGS AS REQUIRED
3000K, 85w--RI (PHILLIPS) FOR A COMPLETE INSTALLATION,
1 1 ? I 3 I 4 I 5 I 6
7
GYP, BD, CEILING
AT 10' -4 1/2" A,F,F,
PI
10
/ Ok OF CASHWRAP, A,C,T,
AND CEILING SOFFIT
LAYOUT (WORKING PT,)
11
12
13
CENTER SURFACE
Mn IMT;=M I Ir�WT
MOUNTED LIGHT ~
TRACK ON GYP,
BD, FASCIA
14
PROVIDE
FLUSH GYP,
BD. ACCESS
DOOR FOR
SENSORMAT
EQUIPMENT
WITH ALL
CONCEALED
HARDWARE,
USE MILCOR
"AT" SERIES
OR EQUAL,
PI
I
V7
e 0-
TYPE
DESCRIPTION
MANUF
MODEL No,
LAMP
REMARKS
AND FITTINGS FURNISH AND INSTALL HANGERS AN FITTINGS AS REQUIRED
FOR A COMPLETE INSTALLATION,
INCANDESCENT TRACK HEADS,
SURFACE MOUNTED STRIP FLUOR.
EMERGENCY LIGHT FIXTURE
SIMKAR
CH240 -EI WITH EMERGENCY
LIGHT FEATURE
(2) F32T8/TL
3000K, 85CRI (PHILLIPS)
F
STRIP FLUORESCENT LIGHT FIXTURE
SIMKAR
CH220TS
(2) 2OW TI2
30OOK, 85C-RI (PHILLIPS)
SURFACE MOUNT IN POCKET ABOVE THREE -WAY MIRROR,
PROVIDE I "XI" PARABOLIC SILVER DIFFUSER AT 8'-0" A,F,F,
REFER TO DETAIL,
FI
FITTING ROOM LIGHT SCONCE
ALKCO
'TABLEAU' ADJUSTABLE
FLUORESCENT - TABI25/PC/277
(1) F25T8
O RECESSED FLUORESCENT
G
PENDANT HUNG INCANDESCENT LIGHT
FIXTURE
FORECAST LIGHTING
ILIGHTOLIER)
HOPE MINI
F487 -36
(1) MED &OW
MOUNT FIXTURE VERTICALLY ALONG EITHER SIDE OF MIRROR
J
RECESSED FLUORESCENT
COVE FIXTURE
ALKCO
MINI -COVE T5 STRIP MINATURE
FLUORESCENT MCS SERIES MC9128
I/FS5T5
4 FT, NOMINAL LENGTH
EX -I
EDGE LIT EXIT SIGN
SURE -LITES
EXC- 5- 1- 70 -WW-R -120
(2) FSTS FLUORESCENT
PROVIDE CHEVRON AS INDICATED ON REFLECTED CEILING PLAN
EX -2
EXIT SIGN
SURE -LITES
PLX- 6200 -RP
1(2) 5W F5TT FLUORESCENT
PROVIDE CHEVRON AS INDICATED ON REFLECTED CEILING PLAN
8 1 q 1 1 1 1 1 1 19 1 17 1 1
15
IM-ReW Evirwring, Inc.
WE SysWn 0M
760 &0*0CI P BArd.
WMbWA* 01i 4=1
614.0182329 Falc 614.818.2337
17
N
1524 Delancey Street
Philadelphia, PA 19102
www.spg3.com
t 215.735.1524 M
f. 215.735.4949
Reflected Ceiling Plan Legend
L
SURFACE MOUNTED LIGHT
Time" TRACK WITH FLUORESCENT AND
INCANDESCENT TRACK HEADS,
® INCANDESCENT PENDANT DOWNLIGHT
O RECESSED ADJUSTABLE
INCANDESCENT DOWNLIGHT
O RECESSED FLUORESCENT
DOWNLIGHT
K
EXISTING DOWNLIGHT TO
lX) REMAIN
O RECESSED FLUORESCENT
LIGHT FIXTURE.
RECESSED FLUORESCENT WITH
EMERGENCY/NIGHT LIGHT,
SURFACE OR PENDENT FLUORESCENT
STRIP LIGHT FIXTURE,
J
® SURFACE OR PENDENT FLUORESCENT STRIP
LIGHT FIXTURE WITH EMERGENCY/NIGHT LIGHT,
® ILLUMINATED EXIT SIGN
(CEILING MOUNTED),
ILLUMINATED EXIT SIGN
(WALL MOUNTED),
4F6 EMERGENCY LIGHT WITH
BUILT -IN BATTERY PACK,
® RECESSED AIR DIFFUSER
H
Q SEMI-RECESSED SPRINKLER HEAD
® EXISTING SPRINKLER HEAD TO REMAIN
a FULLY CONCEALED TYPE SPRINKLER HEAD
m RETURN AIR GRILL
® CEILING EXHAUST FAN
G
General Notes
GFIR
A. EXTEND EXISTING SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13: THE STATE AND
LOCAL FIRE MARSHALL'S OFFICE: THE LANDLORD'S INSURANCE COMPANY AND TENANT'S
INSURANCE CARRIER,
B. COORDINATE HEAD LOCATIONS WITH THE REFLECTED CEILING PLAN AND THE DUCT
DISTRIBUTION SYSTEM ABOVE, PREPARE A DRAWING OF THE FIRE
PROTECTION/SPRINKLER LAYOUT; AND, UPON CONCURRENCE BY BOTH THE LANDLORD
F
AND TENANT, OBTAIN ALL REQUIRED APPROVALS AND CERTIFICATES EVIDENCING SAME,
REFER TO SPECIFICATIONS FOR ADDITIONAL CRITERIA,
ACCM PANELS
A. PROVIDE PAINTED FLUSH METAL CEILING ACCESS DOORS, FOR GYP. BOARD CEILING
AS REQUIRED 13Y " ABOVE CEILING " EQUIPMENT,
B. GENERAL CONTRACTOR TO SUBMIT SKETCH OF CEILING ACCESS DOOR LOCATIONS
TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION,
ACOLI CAL L4Y4N CE1l M
A. PROVIDE A 2'X2' LAY -IN TILE CEILING AND COMPLIMENTARY METAL GRID SUPPORT IN
THE SALES AND FITTING ROOM AREAS AND A 2'X4' LAY -IN ;TILE CEILING AND METAL
GRID IN THE STOCK ROOM AREA, REFER TO THE FINISH SCHEDULE, SHT, A,301, FOR
E
ADDITIONAL INFORMATION,
B. PAINT ALL CEILING GRILLS, DIFFUSERS, ETC, TO MATCH CEILING,
A00"10NAL REWUIRIEME t3
A, BATTERY PACKS FOR EXIT AND EMERGENCY LIGHTS MUST BE REMOTE OR
RECESSED, PAINT EXPOSED SURFACES TO MATCH ADJACENT FINISH.
B. SPRINKLER HEADS IN STOREFRONT WINDOW AND IN HARD SURFACE CEILINGS MUST
BE CONCEALED TYPE, HEADS IN SALES AREA ACOUSTIC CEILING TILE MUST BE
RECESSED TYPE AND CENTERED IN TILE,
C. DO NOT MAKE ANY ATTACHMENTS TO THE LANDLORD'S ROOF DECK OR SOFFIT,
D. USE OF WOOD ABOVE CEILING IS NOT PERMITTED, USE NONCOMBUSTIBLE FRAMING
MEMBERS.
E ALL WOOD MEMBERS USED FOR PURPOSES OF BACKING AND BLOCKING IN AN
p
APPROVED MANNER SHALL BE FIRE RETARDANT TREATED,
R PROVIDE APPROVED EXIST SIGNS INSTALLED AT ALL REQUIRED EXITS AND WHERE
OTHERWISE NECESSARY IN ORDER TO INDICATE THE DIRECTION OF EGRESS, NO POINT
SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN, EXIT SIGNS SHALL BE
INTERNALLY OR EXTERNALLY ILLUMINATED,
05,26,05 FIRE REVIEW COMMENTS Q
04,19,05 ISSUED FOR TENANT AND BUILDING
DEPARTMENT REVIEW
Date Issue Rev. No.
Up Against The Wall
Space No. A -10
The Shops at Sunset Place
South Miami, FL
Reflected Proj. No.: 5016.00