IVISION %00 — ACOUSTICAL CEILINGS
PART I - GENERAL
WORK INCLUDES: SUSPENDED ACOUSTICAL TILE CEILING SYSTEM AS ILLUSTRATED.
STANDARDS: ASTM 0635, C636, E119 -76: UL LABORATORIES.
PART II - MATERIALS
SUSPENSION SYSTEM: CODE APPROVED METAL T-BAR SYSTEM - EXPOSED TEE OR FIRE GUARD
GRID (AS REQUIRED BY LOCAL CODE) BY ARMSTRONG OR EQUAL COLOR: WHITE
HANGER WIRE: ASTM A641, CLASS I, GALVANIZED, 10 GAUGE SOFT- ANNEALED STEEL WIRE
COMPRESSION POSTS: ROBLIN BUILDING PRODUCTS SERIES CS, DONN CORP. CS SERIES, GALVANIZED STEEL,
PERIMETER MOLDINGS: PROVIDE MOLDINGS WITH MATERIAL AND FINISH TO MATCH THE EXPOSED SUSPENSION
COMPONENTS,
ACCESSORIES: AS REQUIRED TO COMPLETE AND COMPLEMENT THE SYSTEM AND INSTALLATION OF LIGHTING
AND "VAC.
PART III - INSTALLATION
GENERAL: FINISHED CEILINGS SHAD.. BE TRUE TO LINES AND LEVELS AND FREE FROM WARPED, SOILED OR DAMAGED
GRID OR ACOUSTICAL UNITS, INSTALL AFTER MAJOR A50VE-CEILING WORK IS COMPLETE COORDINATE THE
LOCATION OF HANGERS WITH OTHER WORK. ENSURE HANGERS AND CARRYING CHANNELS ARE LOCATED TO
ACCOMMODATE FITTINGS AND UNITS OF EQUIPMENT WHICH ARE TO BE PLACED AFTER THE INSTALLATION OF CEILING
GRID. WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR SPACING OF HANGERS, REINFORCE THE NEAREST
ADJACENT HANGERS AND RELATED CARRYING CHANNELS AS REQUIRED TO SPAN THE REQUIRED DISTANCE. PROVIDE
ADDITIONAL HANGERS AND INSERTS AS REQUIRED BY CODE FOR CEILING INSTALLATION. HANG INDEPENDENTLY OF
WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT. WHERE CARRYING MEMBERS ARE SPLICED, AVOID VISIBLE
DISPLACEMENT OF THE LONGITUDINAL AXIS OR FACE PLANE OF ADJACENT MEMBERS, LIGHTING FIXTURES SHALL NOT
BE INSTALLED SUCH THAT THE MAIN RUNNERS AND CROSS RUNNERS WILL BE ECCENTRICALLY LOADED, WHERE FIXTURE
INSTALLATION WOULD PRODUCE ROTATION OF RUNNERS, PROVIDE STABIUZER BARS,
INSTALL: UNITS LEVEL, IN UNIFORM PLANE AND FREE FROM TWIST, WARP AND DENTS, ADJUST ANY SAGS OR TWISTS
WHICH DEVELOP IN THE CEILING SYSTEMS AND REPLACE ANY PART WHICH IS DAMAGED OR FAULTY, INSTALL EDGE
MOLDINGS AT INTERSECTION OF CEILING AND VERTICAL SURFACES, USING MAXIMUM LENGTHS, STRAIGHT, TRUE TO LINE
AND LEVEL, MITER CORNERS, PROVIDE EDGE MOLDINGS AT JUNCTIONS WITH OTHER CEIUNG FINISHES,
Ml
W.. 0_00 4
PART I - GENERAL
WORK INCLUDES: STONE TILE AS ILLUSTRATED,
STANDARDS: TILE COUNCIL OF AMERICA (TCA) - HANDBOOK FOR CERAMIC, TILE INSTALLATION,
ANSI A108,5 - INSTALLATION OF CERAMIC TILE WITH DRY -SET PORTLAND CEMENT MORTAR OR LATEX- PORTLAND
CEMENT MORTAR
PART II - MATERIALS
TILE: REFER TO FINISH SCHEDULE FOR TILE
MORTAR: PORTLAND CEMENT MORTAR WITH LATEX ADDITIVE, ANSI AI18,4,
ORGANIC ADHESIVES: AT VERTICAL APPLICATIONS, ANSI A136,1 TYPE I, INCLUDING PRIMER/SEALER AS RECOMMENDED
BY MANUFACTURER,
CLEAVAGE MEMBRANE POLYETHYLENE FILM, 4 MIL, NOMINAL THICKNESS, COMPLYING WITH ASTM CIA TYPE 1,1,2,
REINFORCING MESH: WELDED WIRE FABRIC 2 INCHES X 2 INCHES 16/16 GAUGE,
BOND COAT ADHESIVE: THINSET BOND COAT, CONSISTING OF LATEX CEMENTiTIOUS MORTAR CONFORMING TO
ANSI AI18,4, MIX WITH LATICRETE 4237 ADDITIVE.
GROUT RELEASE: CERAMASEAL SILOX 8 BY CERAMASEAL STONE 4 TILE CARE PRODUCTS,
GROUT: WATER -PROOF CEMiENTITICUS TYPE, WITH LATEX ADDITIVE. LATICRETE 3701 CONFORMING TO ANSI A115A
COLOR AS SCHEDULED AND IN CONFORMANCE WITH ARCHITECT- APPROVED SAMPLE, MAX WIDTH 1/8 INCH,
WATER: CLEAN, POTABLE AND FREE OF DELETERIOUS SUBSTANCES,
CLEANER: CERAMASEAL NEUTRAL CLEANER BY CERAMASEAL STONE 4 TILE CARE PRODUCTS,
PART III - EXECUTION
DO 1407 USE TILE AND TRIM WITH CHIPS, CRACKS, VOIDS, STAINS, OR OTHER DEFECTS WHICH MIGHT BE VISIBLE IN THE
FINISHED WORK. COMPLETED INSTALLATION SHALL 13E FREE OF BROKEN, DAMAGED, OR FAULTY TILES, LAY ALL TILE
UNITS IN PATTERN SHOWN ON DRAWINGS, WHERE THE PATTERN IS NOT N -loWN, AVOID USE OF UNIT LESS THAN HALF
SIZE, UNLESS OTHERWISE NOTED, ALIGN UNIT SQUARE, PARALLEL AND STRAIGHT, WHEN CUTTING IS REQUIRED, GRIND
EDGES SMOOTH, ACCURATELY CUT UNIT AROUND WORK OF OTHER TRADES SO THAT BRACKETS, ESCUTCHEONS, OR
OTHER COVERINGS WILL COMPLETELY COVER TILE EDGES,
FIRMLY EMBED ALL UNITS IN SETTING MATERIAL WITH FINISHED SURFACES BROUGHT TO TRUE PLANES, SET ALL TILES
IN UNIFORM JOINT WIDTH, ALL JOINTS SHALL BE PLUMB AND LEVEL: ALIGN VERTICALLY AND HORIZONTALLY, AND ALL
TILES TO FORM FLUSH PLANE WITH NO TWO CONTIGUOUS TILES OUT OF FLATNESS BY MORE THAN 1/32 INCH,
INSTALL 9/6 EDGE ANGLES AGAINST ALL PERIMETER TILE EDGES WHERE TILE MEETS DISSIMILAR MATERIALS,
SOUND TILE AFTER SETTING, REMOVE AND REPLACE HOLLOW SOUNDING UNITS,
GROUT JOINTS, AS SOON AS POSSIBLE AFTER INITIAL SET OF SETTING BED, FORCE GROUT INTO JOINTS, STRIKE
FUISHT, AND TOOL SLIGHTLY CONCAVE, WET JOINT SURFACES, IF DRY, PRIOR TO GROUTING, USE WHATEVER MEANS
NECESSARY, WITHOUT BEING HARMFUL TO TILE WORK AND ADJACENT CONSTRUCTION, TO PREVENT GROUT COLOR
FROM STAINING THE FACE OF TILES, PROVIDE PROPER TEMPERATURE AND HUMIDITY CONDITIONS FOR CURING.
CLEANING: UPON COMPLETION OF PLACEMENT AND GROUTING, CLEAN ALL TILED SURFACES SO THAT THEY ARE FREE
OF FOREIGN MATTER. PROHIBIT FOOT AND WHEEL TRAFFIC FROM USING TILED FLOORS FOR AT LEAST 7 DAYS AFTER
GROUTING IS COMPLETED,
PART I - GENERAL
WORK INCLUDES: EXTENT OF RESILIENT FLOORING AND ACCESSORIES INCLUDING BASE AS OUTLINED ON DRAWINGS,
SITE CONDITIONS: INSURE FLOOR SURFACES ARE SMOOTH AND FEAT WITH MAXIMUM VARIATION OF I/8 INCH IN 10 FEET,
PREPARE FLOOR AS NECESSARY TO MEET THESE REQUIREMENTS, INSURE FLOORS ARE DRY (MAXIMUM 7 PERCENT
MOISTURE CONTENT) AND EXHIBIT NEGATIVE ALKALINITY, CARBONIZATION OR DUSTING. MAINTAIN MINIMUM
70 DEGREES F AIR TEi'1PERATURE AT FLOORING INSTALLATION AREA FOR 3 DAYS PRIOR TO, DURING, AND FOR 24 (HOURS
AFTER INSTALLATION,
STORE FLOORING MATERIALS IN AREA OF APPLICATION. ALLOW 3 DAYS FOR MATERIAL TO REACH SAME TEMPERATURE
AS AREA,
INSTALL RESILIENT FLOORING AND ACCESSORIES AFTER OTHER FINISHING OPERATIONS, INCLUDING PAINTING, HAVE
BEEN COMPLETED,
PART II - MATERIALS
VINYL: ARMSTRONG 1/6 INCH GA. 12 INCHES X 12 INCHES
REFER TO "FINISH LEGEND" FOR SPECIFICATION.
BASE: ARMSTRONG 4 INCH VINYL. COVE BASE REFER TO COLOR SCHEDULE FOR SPECIFICATION,
PRIMERS AND ADHESIVES: WATERPROOF: OF TYPES RECOMMENDED BY RESILIENT FLOORING MANUFACTURER FOR
SPECIFIC MATERIAL.
LEVELING COMPOUND: LATEX TYPE AS RECOMMENDER BY FLOORING MANUFACTURER,
PLYillOOD AS FILLER: 1/2 INCH EXTERIOR GRADE
SEALER AND WAX: NON -SKID TYPE RECOMMENDED BY RESILIENT FLOORING MANUFACTURER FOR MATERIAL TYPE AND
LOCATION,
PART III - EXECUTION
PREPARATION: REMOVE SUB-FLOOR RIDGES AND BUMPS, USE LEVELING COMPOUND AS RECOi'1MENDED BY FLOORING
MANUFACTURER FOR FILLING SMALL CRACKS AND DEPRESSIONS IN SUB - FLOOR, CLEAN FLOOR AND LAG PLYWOOD
FILLER IN ADHESIVE TO LEAVE SMOOTH, FLAT, HARD SURFACE, PROH11331T TRAFFIC UNTIL ADHESIVE IS CURED, APPLY
CONCRETE SLAB PRIMER, IF RECOMMENDED BY FLOORING MANUFACTURER, PRIOR TO APPLICATION OF ADHESIVE.
APPLY IN COMPLIANCE WITH MANUFACTURER'S DIRECTIONS,
INSTALLATION: INSTALL FLOORING USING METHOD INDICATED IN STRICT COMPLIANCE WITH MANUFACTURER'S
RECOMMENDATIONS, EXTEND TILE INTO TOE SPACES, DOOR REVEALS AND INTO CLOSETS AND SIMILAR OPENINGS,
SCRIBE FLOORING To WALLS, COLUMNS, CABINETS, FLOOR OUTLETS AND OTHER APPURTENANCES, To PRODUCE TIGHT
JOINTS, APPLY WALL BASE TO WALLS, COLUMNS, PILASTERS, SCHEDULED CASEWORK AND OTHER PERMANENT
FIXTURES IN ROOMS WHERE BASE IS REQUIRED. INSTALL BASE IN LENGTHS AS LONG AS PRACTICAL, TiGHTLY BOND
BASE To SUBSTRATE THROUGHOUT LENGTH OF EACH PIECE WITH CONTINUOUS CONTACT AT HORIZONTAL AND VERTICAL
SURFACES. RUN TILE GRAIN IN ONE DIRECTION,
CLEAN UP AND PROTECTION: REMOVE EXCESS ADHESIVE FROM FLOOR, BASE AND WALL SURFACES WITHOUT CAUSING
DAMAGE.
CLEAN, SEAL AND WAX FLOOR AND BASE SURFACES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS,
PROHIBIT TRAFFIC FROM FINISHED FLOOR FOR 48 HOURS AFTER INSTALLATION, PROTECT COMPLETED WORK WITH
NON - STAINING BUILDING PAPER UNTIL FINAL ACCEPTANCE OF WORK,
DIVISION %80 - CARPETING
PART 1 - GENERAL,
WORK INCLUDES: TACKLESS INSTALLATION OF CARPET. EXTENT OF CARPET AND ACCESSORIES IS SHOWN ON
DRAWINGS,
PROJECT CONDITIONS: DO NOT INSTALL CARPET UNTIL DIET CONSTRUCTION IS COMPLETED AND SURROUNDING AIR
HAS MAXIMUM MOISTURE CONTENT OF 40 PERCENT, PROVIDE PERMANENT HEAT, LIGHT AND VENTILATION PRIOR TO
INSTALLATION, MAINTAIN ROOM TEMPERATURE AT A MINIMUM OF 65 DEGREES F FOR A PERIOD OF 7 DAYS PRIOR TO
THE DELIVERY OF MATERIALS,
DELIVERY AND STORAGE: DO NOT DELIVER MATERIALS UNTIL SITE CONDITIONS ARE ADEQUATE TO RECEIVE WORK,
PROTECT FROM WEATHER WHILE IN TRANSIT, AND AGAINST MOISTURE AND ABRASION AFTER DELIVERY,
PART 11 - MATERIALS
CARPET: BY OWNER. REFER TO FINISH SCHEDULE
TACKLE% STRIPPING: STANDARD
SEAM SEALER., ORCON "CT -3" TAPE, ROBERT COMPANY "GOLDEN TOUCH ", L.D. BRINKMAN +55 "SUPREME
OR COMPATABLE MATERIAL DIRECTED BY CARPET MANUFACTURER,
PART III - EXECUTION
PREPARATION: CLEAN FLOORS OF DUST, DIRT, SOLVENTS, OIL, GRE45E, PAINT, PLASTER AND OTHER SUBSTANCES
DETRIMENTAL TO PROPER PERFORMANCE OF ADHESIVE AND CARPET, ALLOW FLOORS TO THOROUGHLY DRY, INSURE
CONCRETE FLOORS ARE FREE FROM SCALING AND IRREGULARITIES AND DWIBIT NEUTRALITY RELATIVE TO ACIDITY AND
ALKALINITY, USE AN APPROViD CE I- IENTMOUS FILLER TO PATCH CRACKS AND SMALL HOLES, AND FOR LEVELING.
INSURE FLOORS ARE LEVEL WITH MAXIMUM SURFACE VARIATION OF 1/8 INCH IN 10 FEET, NONCUMULATIVE.
COMMENCEMENT OF CARPET INSTALLATION SHALL SIGNIFY ACCEPTANCE OF SATISFACTORY CONDITIONS,
INSTALLATION
A Architectural Specifications
2
GENERAL: THE CONTRACTOR SHALL SCHEDULE THE WORK SO THAT A MINIMUM OF PAINTING WILL OCCUR OVER LAID
CARPET AND ASSURE THAT THE CARPET IS PROTECTED FROM DAMAGE FROM ANY SOURCE. UNLESS OTHERWISE
DIRECTED BY THE OWNER OR THE G.C., THE CARPET SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF
ALL INTERIOR DOORS, STACKING NO MORE THAN 4 TOGETHER WITH PROTECTIVE SPACERS BEIWEETI, AND REHANCsFNs,
CHECK MATCHING OF CARPET BEFORE CUTTING AND INSURE THERE IS NO VISIBLE VARIATION BETWEEN DYE LOTS. CUT
CARPET WHERE REQUIRED, IN A MANNER TO ALLOW PROPER SEAM AND PATTERN MATCH, INSURE CUTS ARE STRAIGHT
AND TRUE AND UNFRAYED. CUT CARPET FROM FACE ONLY BETWEEN ROWS UAT14 ADJUSTABLE LOOP PILE CUTTER.
SEAL ALL CUT EDGES WITH BEAD OF SEAM SEALER NOTED ABOVE, ALLOW TO DRY PRIOR TO SEAMING,
INSTALLATION: ALL CARPET SHAD- BE LAID IN THE SAME DIRECTION UNLESS SPECIFICALLY SHOWN OTHERWISE NO
SEAMS SHALL OCCUR PERPENDICULAR TO DOORS OR ENTRIES, SEAMS OCCURRING PARALLEL TO DOORS SNAIL BE
CENiiRED DIRECTLY UNDER THE DOOR, SEAMS OCCURRING AT CORRIDOR CHANGE OF DIRECTION SHALL FOLLOW
WALL LINE PARALLEL TO CARPET DIRECTION. LOCATE SEAMS IN ACCORDANCE WITH APPROVED LAYOUT AND SEAMING
PLANS, TRIM EDGES AND HEAT SEAM, USING MATERIALS AND METHODS RECOMMENDED BY CARPET MANUFACTURER
AND IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS. INSURE SEAMS ARE STRAIGHT,
NOT OVERLAPPED OR PEAKED, AND IRE, PROM GAPS. VACUUM CLEAN SUBSTRATE. CUT AND FIT CARPET NEATLY
AROUND PROJECTIONS THROUGH FLOOR, AND TO WALLS AND OTHER VERTICAL SURFACES, THE FINISHED
INSTALLATION SHALL BE TREE FROM TACKS, SCRAPS, CARPET RIPPLES, SCALLOPS, PUCKERS, SPROUTS AND OTHER
DEFECTS.
CLEAN UP 4 PROTECTION: AFTER INSTALLATION IS COMPLETE, CLEAN UP ALL DIRT AND DEBRIS AND CLEAN ALL
SPOTS WITH PROPER SPOT REMOVER REMOVE ALL LOOSE THREADS AND VACUUM, THE OWNER SHALL REVIEW ALL
CARPET SCRAPS AND RETAIN ANY IT CHOOSES FOR FUTURE REPAIRS,
SECTION 97000- CEMENTITIOUS DECKS AND TOPPINGS (ARDEX)
PART I: GENERAL
A. Summary
I, Section includes:
a. Self - leveling cementAtious underlayment.
B, Qualifications
1, Installation of the cement - based, self - leveling underlayment must
be by an applicator using mixing equipment and tools approved by
the manufacturer.
2, Provide adex K -15 self - leveling underlayment concrete as
manufactured by Ardex, Inc,, 630 Stoops Ferry Road Corapolis,
PA 15108,
3, Underlayment shall be walkable after two hours at 70° F and be
able to be covered by flooring material In 16 hours.
C. Submittals
I. Product Data:
a. Materials list of Items proposed to be provided under the
section.
D. Dellver, Storage, and Handling
I. Dellver materials in their original, unopened packages and protect
from freezing, direct sun exposure, an exposure to moisture.
PART 2: PRODUCTS
A, Materials
I, Primer for standard absorbent concrete shall be Ardex P -51 primer,
2, Primer for non - porous substrate, cut -back adhesive residue, and
metal and wooden subfloora shall be Ardex P -82 ultra- prime.
3, The additive to be mixed with Ardex K -15 when used over
cut -back adhesive, metal or wooden subfloors shall be
Ardex E -25 resilient emulsion,
4, Aggregate shall be well - graded, washed pea gravel (1/8" to 1/4"
or larger) for use when underlayment Is Installed over 1 -1/2" thick,
5, Water shall be clean, potable, and sufficientiy cool Mot warmer
than 70' F),
B, Technical Data. all data Is based on a mixing ratio of 3,5 P.B.V, of
powder to I P.B,v, of water,
1. Flowing Time: approximately 10 minutes at 70° F
2, Initial Set, ASTM C191: approximately 30 minutes at 70° F
3, Final Set, ASTM CI91: approximately 2 hours at 70" F
4, Compressive Strength, ASTM C- 109/MOD: approximately 4,100 PSI
after 48 days
5, Flammability, ASTM E- 84 -81A:
a, Flame Spread: 0,
b, Fuel Contribution: O.
c, Smoke Development: O,
6, Coverage, 551b, bag:
a. Approximateiy 60 S,F, at 1/8"
b, Approximateiy 30 S,F, at 1/4"
PART 3: EXECUTION
A. Preparation
I, In addition to the general procedures described herein, refer to
manufacturer's current published product literature for complete
installation details for the underlayment system being Installed,
2, All surfaces regardless of material, must be solid, thoroughly
cleaned of all deletrious material Including loose agcIre- ,
particulate and grease, and dried of any surface moisture.
B, Priming
I. Primer for standard absorbent concrete subfloors,
a, Prime with Ardex P -51 Primer, underlayment shall not be
applied until primer Is dry.
C. Installation
I. Installation to be done by installer certifled by the manufacturer,
using mixing and installation methods as specifled by the
manufacturer.
I8 I 9 I 10 I
DIVISION 9900 - PAINTING
PART I - GENERAL
WORK INCLUDES: EXTENT OF PAINTING AND FINISHING INCLUDES (BUT IS NOT LIMITED TO) WORK AS SHOWN ON
DRAWINGS AND SCHEDULES AND AS HEREIN SPECIFIED, PAINTING ALL GYPSUM DRYWALL EXPOSED TO VIEW,
INCIDENTAL PAINTING AND TOUCHING UP AS REQUIRED TO PRODUCE PROPER FINISH FOR ALL PAINTED SURFACES,
INCLUDING TOUCHING UP OF FACTORY FINISHED ITEMS. PAINTING OF ANY SURFACE, NEW OR EXISTING, NOT
SPECIFICALLY MENTIONED TO BE PAINTED HEREIN OR ON DRAWINGS BUT FOR WHICH PAINTING IS OBVIOUSLY
NECESSARY TO COMPLETE THE JOB,
DEFINITION: PAINT, AS HEREIN USED, MEANS ALL COATING SYSTEM MATERIALS INCLUDING PRIMERS, EMULSIONS,
ENAMELS, STAINS, SEALERS AND FILLERS AND OTHER APPLIED MATERIALS WHETHER USED AS PRIME, INTERMEDIATE OR
FINISH COATS,
WORK NOT INCLUDED: THE FOLLOWING CATEGORIES OF WORK ARE NOT INCLUDED AS PART OF FIELD APPLIED FINISH
WORK UNLESS OTHERWISE INDICATED:
I, WALLS AND CEILINGS IN CONCEALED AND INACCESSIBLE AREAS,
11 FINISHED METALS SUCH AS ANODIZED ALUMINUM, STAINLESS STEEL, CHROME PLATE, BRONZE AND SIMILAR
FINISHED MATERIALS,
3, DO NOT PAINT OVER ANY CODE REQUIRED LABELS, SUCH AS UNDERWRITERS LABORATORIES AND FACTORY
MUTUAL OR ANY EQUIPMENT IDENTIFICATION PERFORMANCE RATING, NAME OR NOMENCIATLI RE PLATES,
4. MOVING PARTS OF OPERATING UNITS,
JOB CONDITION: APPLY WATER -BASE PAINTS ONLY WHEN TEMPERATURE OF SURFACES TO BE PAINTED AND
SURROUNDING AIR TEMPERATURE ARE BETWEEN 45 DEGREES F (7 DEGREES C) AND % DEGREES F
(35 DEGREES C), UNLESS OTHERWISE PERMITTED BY PAINT MANUFACTURER'S PRINTED INSTRUCTIONS,
PART II - MATERIALS
MANUFACTURER: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE BEST QUALITY PRODUCTS OF THE
SHERWIN WILLIAMS CO,
SHERWIN WILLIAMS ARCHITECTURAL DEPARTMENT
1- 800 - 321.8194
PART III - EXECUTION
INSPECTION: EXAMiINE AREAS AND CONDITIONS UNDER WHICH PAINTING WORK IS TO BE APPLIED AND NOTIFY
CONTRACTOR IN WRITING OF CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF WORK. STARTING
OF PAINTING WORK WALL BE CONSTRUED AS APPLICATOR'S ACCEPTANCE OF SURFACES AND CONDITIONS WITHIN ANY
PARTICULAR AREA,
SURFACE PREPARATION: REMOVE HARDWARE, HARDWARE ACCESSORIES, MACHINED SURFACES, PLATES, LIGHTING
FIXTURES AND SIMILAR ITEMS M PLACE AND NOT TO BE FINISH- PAINTED, OR PROVIDE SURFACE - APPLIED PROTECTION
PRIOR TO SURFACE PREPARATION AND PAINTING OPERATIONS. FOLLOWING COMPLETION OF PAINTING OF EACH SPACE
OR AREA REINSTALL REMOVED ITEMS,
APPLICATION
GENERAL: APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS, USE APPLICATORS AND TECHNIQUES
13EST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. APPLY ADDITIONAL COATS WHEN UNDERCOATS,
STAINS OR OTHER CONDITIONS SHOW THROUGH FINAL COAT OF PAINT, UNTIL PAINT FILM IS OF UNIFORM FINISH,
COLOR AND APPEARANCE GIVE SPECIAL ATTENTION TO INSURE THAT SURFACES, INCLUDING EDGES, CORNERS,
CREVICES, WELDS AND EXPOSED FASTENERS RECEIVE A DRY FILM THICKNESS EQUIVALENT TO THAT OF FLAT SURFACES,
PRIME, STAIN, OR SEAS_ WOOD REQUIRED TO BE JOB PAINTED IMMEDIATELY WON DELIVERY TO JOB, PRIME EDGES,
ENDS, FACETS, UNDERSIDES AND BACKSIDES OF SUCH WOOD, INCLUDING CABINETS, COUNTERS, CASES, PANELING,
PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE SAME AS SIMILAR EXPOSED SURFACES, PAINT
SURFACES BEHIND PERMANIENTLY -FIXED EQUIPMENT OR FURNITURE WITH PRIME COAT ONLY BEFORE FINAL
INSTALLATION OF EQUIPMENT, PAINT INTERIOR SURFACES OF DUCTS, WHERE VISIBLE THROUGH REGISTERS OR GRILLES,
WITH A FLAT, NON- SPECULAR BLACK PAINT. PAINT BACK SIDES OF ACCESS PANELS, AND REMOVABLE HINGED COVERS
TO MATCH EXPOSED SURFACES,
CLEAN-UP: DURING PROGRESS OF WORK, REMOVE FROM SITE DISCARDED PAINT MATERIALS, RUBBISH, CANS AND RAGS
AT END OF EACH WORK DAY. UPON COMPLETION OF PAINTING WORK CLEAN WINDOW GLASS AND OTHER PAINT - SPLATTERED
SURFACES, REMOVE SPLATTERED PAINT BY PROPER METHODS OF WASHING AND SCRAPING, USING CARE NOT TO SCRATCH
OR OTHERWISE DAMAGE FINISHED SURFACES,
AT COMPLETION OF WORK OF OTHER TRADES, TOUGH -UP AND RESTORE ALL DAMAGED OR DEFACED PAINTED SURFACES,
UPON COMPLETION OF THE WORK, REMOVE SURPLUS MATERIALS, EMPTY PACKAGES AND CONTAINERS AND DEBRIS FROM THE
SITE AND DISPOSE BY LEGAL MEANS,
PROTECTION: PROTECT WORK OF OTHER TRADES, WHETHER TO BE PAINTED OR NOT, AGAINST DAMAGE BY
PAINTING AND FINISHING WORK, CORRECT ANY DAMAGE BY CLEANING, REPAIRING OR REPLACING, AND REPAINTING
AS ACCEPTABLE TO THE ARCHITECT.
PAINT SCHEDULE
REA=R TO FINISH SCHEDULE FOR COLOR
GYPSUM DRYWALL SURFACES:
SALES AREA-WALLS
IST COAT- CUICK DRY PRIME SEAL
COLOR 2ND COAT - WALL SATIN FLAT
COLOR 3RD COAT - WALL SATIN FLAT
SAI E5 AREA - WOODWORK AND DOORS
IST COAT - ALKYD ENAMEL. UNDERBODY
COLOR 2ND COAT - SEMI-GLOSS
COLOR 3RD COAT - SEMI -GLOSS
SALES AREA - HALLWAYS
IST COAT - QUICK DRY PRIME SEAL
COLOR 2ND COAT - EGGSHELL
COLOR 3RD COAT - EGGSHELL
STOCK AREA -WALLS
IST COAT - QUICK DRY PRIME SEAL_
COLOR 2ND COAT - WALL SATIN
COLOR 3RD COAT - WALL SATIN FLAT
STOCK ,AREA - WOODWORK AND DOORS
IST COAT - ALKYD ENAMEL UNDERBODY
COLOR 2ND COAT - SEMI -GLOSS
COLOR 3RD COAT - SEMI-GLOSS
HOLLOW METAL DOORS 4 FRAMES-
EXTERIOR LOCATIONS:
IST COAT - RUST INHIBITOR
COLOR 2ND COAT - SE MI -GWSS
COLOR 3RD COAT - SEMI-GLO%
INTERIOR LOCATIONS:
• COLOR FOR SALES AND STOCK
IST COAT - WHITE PRIMER
2ND COAT - SEMI -GLOSS
3RD COAT - SEMI -GLOSS
11 12 13 14
DIVISION 9950 - WALL COVERNGS
PART I - GENERAL
WORK INCLUDES: VINYL COATED AND FABRIC WALLCOVERINGS AS ILLUSTRATED.
QUALITY ASSURANCE: USE ONLY SUBCONTRACTORS EXPERIENCED WITH THE INSTALLATION OF SIMILAR MATERIALS,
FIRE HAZARD CLASSIFICATION: PROVIDE MATERIALS BEARING UL LABEL AND MARKING, INDICATING FIRE HAZARD
CLASSIFICATION OF WALL COVERING, AS DETERMINED BY ASTI1 E 84,
PROVIDE MATERIALS WITH THE FOLLOWING FIRE HAZARD CLASSIFICATIONS:
FLAME SPREAD NOT MORE THAN 25,
SMOKE DEVELOPED NOT MORE THAN 50,
PART II - PRODUCTS
VINYL WALL COVERING: REFER TO FINISH SCHEDULE
MEDIUM DUTY: TYPE II: TOTAL WEIGHT NOT LESS THAN 13 OZ, PER SQUARE YARD, VINYL COATING NOT LESS
THAN 7 OZ, PER 50, YD, SEE FINISH SCHEDULE FOR MANUFACTURER AND COLOR.
ADHESIVES: PROVIDE MANUFACTURER'S RECOMMENDED ADHESIVE, PRIMER AND SEALER, PRODUCED EXPRESSLY FOR
USE WITH SELECTED WALL COVERING ON SUt36TRATE AS SHOIIM ON DRAWINGS, PROVIDE MATERIALS WHICH AIRE
MILLDIEW- RESISTANT AND NON-STAINING TO WALL COVERING,
RELEASE COAT: OIL BASE SEALER OR ENAMEL UNDERCOATER FOR VIRGIN DRYWALL SUBSTRATES AS RECOMMENDED BY
COVERING MANUFACTURER,
PART III - EXECUTION
PREPARATION: ACCLIMATIZE WALL COVERING MATERIALS BY REMOVING FROM PACKAGING IN AREA OF INSTALLATION
NOT LESS THAN 24 HOURS BEFORE APPLICATION, REMOVE SWITCH PLATES, WALL PLATES AND SURFACE- MOUNTED
FIXTURES IN AREAS WHERE WALL COVERING IS TO BE APPLIED, PRIME AND SEAL SUBSTRATES IN ACCORDANCE WITH
WALL COVERINGS MANUFACTURER'S RECOMMENDATIONS FOR TYPE OF SUBSTRATE APPLY SURFACE SEALER TO
GYPSUM DRYWALL WHICH WILL PERMIT SUBSEQUENT REMOVAL OF WALL COVERING WITHOUT DAMAGE TO PAPER
FACING,
INSTALLATION:
ILLUMINATE AREAS OF INSTALLATION USING BUILDING'S PERMANENT LIGHTING SYSTEM: TEMPORARY LIGHTING ALONE
WILL NOT BE ACCEPTABLE PLACE WALL COVERING PANELS CONSECUTIVELY IN ORDER CUT FROM ROLLS, INCLUDING
FILLING OF SPACES ABOVE OR BELOW OPENINGS, HANG BY REVERSING ALTERNATE STRIPS EXCEPT ON MATCH
PATTERNS APPLY ADHESIVE TO BACK OF WALL COVERING AND PLACE IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS, INSTALL SEAMS PLUMB, AND AT LEAST 6 INCHES AWAY FROM CORNERS, HORIZONTAL SEAMS ARE NOT
PERMITTED, OVERLAP SEAMS AND DOUBLE-CUT TO ASSURE TIGHT CLOSURE ROLL, BRUSH, OR USE BROAD KNIFE TO
REMOVE AIR BUBBLES, WRINKLES, BUSTERS AND OTHER DEFECTS, CUT WALL COVERING EVENLY TO EDGES OF WALL
PENETRATIONS, TRIM SALVAGES AS REQUIRED TO ASSURE COLOR UNIFORMITY AND PATTERN MATCH, REMOVE EXCESS
ADHESIVE ALONG FINISHED SEAMS WHILE IT IS STILL WET USING WARM WATER AND CLEAN SPONGE, AND WiPE
DRY, REPLACE REMOVED PLATES AND FIXTURES: VERIFY CUT EDGES OF WALL COVERINGS ARE COMPLETELY
CONCEALED, REMOVE SURPLUS MATERIALS, RUBBISH, AND DEBRIS RESULTING FROM WALL COVERING INSTALLATION
UPON COMPLETION of WORK, AND LEAVE AREAS OF INSTALLATION IN NEAT, CLEAN CONDITION,
DIVISION 9975 - NON -SKID TILE TREATMENT
PARTI - GENERAL
WORK INCLUDES: INSTALLATION OF A NON- SKID SAFETY FINISH ON ALL TILE FLOOR SURFACES.
QUALITY ASSURANCE: USE ONLY SUBCONTRACTORS EXPERIENCED WITH THE INSTALLATION OF SIMILAR MATERIALS.
FIRE HAZARD CLASSIFICATION: PROVIDE MATERIALS BEARING UL LABEL AND MARKING, INDICATING FIRE HAZARD,
PART II - PRODUCTS
"NO- SLIP" TREATMENT SLIP RESISTANT FINISH, INSTALLED PER MFGR. INSTRUCTIONS.
PRODUCT AS SUPPLIED BY 051 HARD SURFACES, 6 KENVIE W BLVD., BRAMPTON, ONTARIO, CANADA L&T 5E4
PHONE 905 - 7934930
CONTACT: WENDY O'BRIEN
M-ReWI Englneedng, Inc.
WE System Enptneeiino o=
760 OmdMdfle INV&
weetenAde, OH 43061
6142182923 Fox 614.818.2337
04,19,05 ISSUED FOR TENANT AND BUILDING
DEPARTMENT REVIEW
Date Issue
17
1524 Delancey Street
Philadelphia, PA 19102
www.spg3.com
t. 215.735.1524
f. 215.735.4949
,..,, .._.. Rev. No.
Up Against The Wall
Space No. A -10
The Shops at Sunset Place
South Miami, FL
•ti. „._ A k6;+1ft0,} I Proj. No.: 5016.00
r,
3 4 5 6 7 8 9 10 11 12 13 14 15
N
M
L
J
H
C
19
E
0
C
[to Ulm
Specifications
QAoQJJQ�Jd A
G:
16 1 17