Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-676-019
m A N O to N O I N n 'X' - 2 -V2'� j - 2' 14ATERR SUPPLY FIXTURE UNITS MARK DESCRIPTION FIXTURE UNITS QUANTITY TOTAL F. U. P -IH HANDICAPPED WATER CLOSET 2.0 2 4.0 P -2H HANDICAPPED LAVATORY 1.0 2 2.0 P-3 SERVICE 5IW 3.0 1 3.0 P-4H LOUN6E SINK 1.4 1 1.4 EW!r i H WATER GOOIER 0.25 2 .50 EW/_IH WATER COOLER .5 1 2 1 TOTAL 10.01 SEE DRS. FIE-I FOR FIXTURE DESI6NATIONS. WATER PIPING ABOVE 6RADE SHALL BE TYPE 'L' HARD COPPER ASTH B 88-832 WITH WROU6HT COPPER FITTIN65 ASTM B 16.22- 1480 AND NON -LEAD OR ANTIMONY SOLDER JOINTS AND TYPE: 'K' SOFT COPPER WITH SILVER SOLDER JOINTS BELOW 6RADE. WATER SERVICE AND DISTRIBUTION PIPING SHALL. CONFORM TO NSF 61. SOLDER JOINTS SHALL CONFORM TO ASTM B828 AND FLUX SHALL CONFORM TO ASTM B 813. PIPIN6 SHALL BE LABELED TO IDENTIFY TYPE OF SERRVICE. CHROME PLATED SHUT OFF VALVE E5=iCHEON AT WALL EXTEND I/2' C44 BACK INTO - WAU- WITH CHROME PLATED ES GHEONS AND ROUTE BELOW FLOOR TO DRAIN TRAPS AS INDICATED ON PLANS. GTX VERIFY EXACT LOCATION AND 51ZE IN FIELD PRIOR TO START OF WORK. 01 / COLD WATER SUPPLY IN WALL TRAP PRIMER VALVE MTH INTEGRAL VACUJH BREAKER. PRECISION PLUMBING PRODUG715 OREO5ON 41. INSTALL EXP05EV BELOW LAV. TWO OUTLET DISTROMON UHT. 5EU>RED TO WALL. PROVIDE THREE OUTLET AS RE01RED. FLOOR TRAP PRIMER VALVE DETAIL SCALE: NOW LAVATORY TEiIIPEI;�Ev HW SUPPLY CA SUPPLY THB2M05TATiG TBPERIN6 VALVE, POWERS HYDROSIIARD SERIES 480 HW SUPPLY STOP VALVE FINISH FLOOR LAVATORY TEMPERING VALVE DETAIL 5GALE■ NOW WATER HAMMER ARRESTOR, P.P.P. WIN R 50-500, TYPICAL i I WATER PIPING DIAGRAM SCALE NOW CODED NMESs OI SHUT OFF VALVE - TYPICAL 0 CHECK VALVE - TYPICAL O EXPANSION TANK AMTROL NO. %-5 WITH INCH COM6CT10K ® DIEL.EGTRIG UNION - TYPICAL O WATER HEATER © 2' DEEP 6ALVA (ZED STEEL DRAIN PAN WITH SOLDERED SEAMS AND TWO COATS OF RUST INHIBM PAINT. O T 4 P RELIEF VALVE WATTS NO. 100XL -4125. ® PIPE RELIEF DRAIN FULL SIZE TO 58ZACE SINK WITH 2' AIR 6AP ® MOUNT ON 1/4' STffi. C 1150 R D PLATE WITH 2 -L/2' x 2 -I/2' x 1/2' ANGLE IRON BRACKETS ABOVE SERVICE SINC. 10 20 GAUGE STEM, i' NUDE SEISMIC, RESTRAINT STRAP. SEUARE TO WALL WITH 1/4' LA6 5OLT5 AT EACH SIDE II wcm RELIEF VALVE SHUT -OFF VALVE TYPICAL WATER HEATER PIPING DIAGRAM SCALE: NONE PL UMBIl� IX' ' XR' OR X -X --X GTX 0 N.G. E.G. P. G. 6. G. --- SAN - -- ---------- �----- - - - - -- CH ---- HW - - -- CO FD A.F.F. .= EXISTIN6 TO REMAIN EXISTIN6 TO BE REMOVED CONNECT TO EXISTIN6 INDICATES CODED NOTE MECHANICAL CONTRACTOR ELBCTRIGAL CONTRACTOR PLUHBIN6 CONTRACTOR 6ENER& CONTRACTOR SANITARY SE9"BR BELON 6RADE SANITARY aH$t ABOVE 6RADE SANITARY VENT DORE5TIG GOLD WATER DOMESTIC HOT HATER U.EAIJOUT FLOOR DRAIN SHUT OFF VALVE CHECK VALVE ABOVE FINISHED FLOOR ®�-'X' - 2 -In' / F2 GTX GW, VERIFY F Q -i- EXACT LOCATION AND SIZE IN FIELD. - -- -- GW- ----- - - - - -- - EXISTING SPRINKLi32 LINES TO 8E -- �[: ■ �'k - 3' I DEMOL15HED IN EXPANSION AREA, NEW I I I 5PRINKLER PIPING SHALL 13E RAIEED , AS HIGH AS POSSIBLE AND SPRINKLER HEADS LDGATED PER HEW LAYOUT. -- - -- I REMOVE EXISTING FLOOR DRAINS AND GAP BELOW FLOOR, PATCH FLOOR TO FD 'XR' - FD MATCH EXISTING - TYPIGAL GTX SAN DRAIN. VERIFY - - EXAGT LOCATION, DEPTH, � 'XR' FD SIZE AND DIREG110N OF 6'7 I FLOW IN FIELD, TYPICAL i -- -- SAN- Fp �- I -� 'k - GO 0 'xR' - ,I El Z481 SAW G1JT TRENCH - -i ' -- -- ' - j - - - ! f - - - -❑ -i 'XR' - FD _ - FD,, INSTALL SANITARY PIPING, I - BACKFILL AND PATCH I �� - FID FLOOR TO P:GCEPT NEW MAINTAIN SOUND PROOFIHI6� STOCKROOM I GO FINISH, TYPICAL - - - - I 'XR' -FD B (THROUGH OFFICE WALLS. El 4)�ly 2- ;- -- - 'XRa- FpP • I OFFICE , I ED .2 H GTX 13' VENT i P - I l -E FV P � Ii WOMEN N 'X R - FD P • 0 ' IH _ IN ABOVE B EWG 3 CORIDOR P I P - - - I - I - - -T -- I GTX PLUMBING FLOOR PLANC) 1/6" = 1'-O' SANITARY FIXTURE UNITS MARK DESCRIPTION FIXTURE UNITS QUANTITY TOTAL F. U. P -iH HANDICAPPED WATER CLOSET 4 2 8 P -2H HANDICAPPED LAVATORY 1 2 2 P -3 SERVICE SINK 2 1 2 P-4H L.OUN6E SINK 2 1 2 FD -i FLOOR DRAIN 2 2 4 EW/_IH WATER COOLER .5 1 2 1 TOTAL 19 r 'X' - CO - - - -- - - -- - -T- 2' VENT LINE. GOMEGT TO EXISTING M AJN VENT LINE FED VERIFY EXACT POINT OF CONNECTION. I -I/2 '�' 2 j I -I/2'I �•��� ^20 ` I ICI -I/2' � 2■ - 4•-� I I I �1-�. SEE DWG. ME -I FOR MATERIAL 30 �4 5PECIFIGATiON5 AND PLUMBING R2 I �_ I_ I I I I FIXTURE DE516NAT1oN5. j 3. �I -I/2' 5 I 4. 4 1 -1/2 I I 3. P-I0 4 3' PFl�k2 .4 1 2■ lDy 4' I� PVC PIPIN6: R 2. �` A. MAY ONLY BE USED WHEN SPECIFICALLY LISTED BELON. 3' B. SHALL NOT BE INSTALLED IN RETURN AIR PLENUMS OR 3 � WHEiRE D I SCHNAR6E WATER TEMPERATURE EXCEEDS 120 DE 6 �■ I F, USE NO HUB CAST IRON OR 6ALVANIZED STEEL i LT- �I PLUMBING DEMOLITION i 0 5 `f5 A. CONTRACTOR SHALL COORDINATE TINES TO WORK IN SPECIFIC AREAS OF THE EXISTING BUILDING WITH THE BUILDING MANAffP- ----- ^ B. REMOVE ALL EXISTING PLUMBING FIXTURES AND EiWRr -ff NOT 'f0 REMAIN, - RB40VE SANITARY BACK BEYOND FINISHED SURFAZZ-3, RB 10rr F;GT NND- COLD WATER PIPING BACK TO ACTIVE MAINS AND GAP. PATCH SURFACES TO HATCH EXISTING. C. CONTRACTOR I5 RESPONSIBLE FOR REMOVAL AND REPLAGEN W OF EXISTING C431.I1465 IN ALL AREAS OF DEiMOLIT10N WORK. D. DEMOLITION WORK INGLUM THE REMOVAL OF ALL NEED HANGER5, CONTROI- WIRING, VALVES, ETC. ALL PIPING SHALL 13E REMOVE TO BEYOND FINISHED FLOOR OR WALL 51JRFAGE AT FIXTURE LOCAT10N5, OR BACK TO ACTIVE RAINS FOR OTHER PIPING. FLOORS, OVAL L5 AND CEILIN65 SHALL BE PATCHED TO MATCH EXISTING IN EXISTING AREAS TO REMAIN, OR PATCHED AND PREPARED FOR NEW FINISH IN AREAS TO BE R19,10DELED. PROTECT EA5TING TILE OR CARPET, OWNER WILL PATCH TiLE OR CARPET. E OWNER SHALL DE516NATE ANY ITEMS TO BE SALVA6ED BY CONTRACTOR PRIOR TO START OF DEMOLITION. CONTRACTOR SHALL PROTECT AND TURN OVER TO OWNER ALL SALVA6W ITEMS AT OWNER DESIGNATED LOCATION IN THE BUILDIN6. ALL OTHER VB40UTION MATERIALS SHALL BE FZ40VED FROM THE BUILDING AND LE&ALLY DISPOSED. F. CONTRACTOR S TO REPAIR ANY OPENN66 IN FIRE RATED GONSTRUGTiON CAUSED BY THE DEMOLITION WORK TO MATCH EXISTINS C.ONSTI;MTION AND MAINTAIN FIRE RATING. PLUMBING GENERAL NOTES A. EXISTING UTILITY LOCATIONS INDICATED WERE OBTAINED FROM 5H ELL DRANN65 BY SIMON DEBARTOLO 6ROUP, DATED 11/20/47. THE LOCATION OF EX15T1N6 UTILITIES HAS NOT BEEN VERIFIED IN THE FIELD. THEREFORE THE PLUMBING CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATIONS AND SIZES OF ALL UTILITIES, IWAMN6 THE DEPTHS OF ALL BELOW GRADE SANITARY SEERS, PRIOR TO THE START OF WORK. THESE DRAWINGS ARE NOT INTENDED TO INDICATE ALL EXISTIN6 UTILITIES. B. CONTRACTOR SHALL BE FAMILIAR WiTH LANDLORDS STANDARDS, RU.E5 AND RE611LATIONS. OBTAIN COPY OF MALL'S CRITERIA PACKA6E AND CONFORM TO ALL RE MIREM NI'S. ALL LANDLORD'S CRITERIA SHALL BE COMPLIED WITH AND INCLUDED IN 'MI5 510. G. CONTRACTOR SHALL V151T 51TE PRIOR TO 5UBMITTING BID AND FIELD VERIFY EXISTiN6 CONDITIONS TO ENSURE THAT THE WORK ON THE DRAWINGS AND IN THESE SPECIFICATIONS CAN 13E INSTALLED AS INDICA TED. CONTRACTOR SHALL TAKE ALL INf13RFEI;EJCE5 INTO CONSIDERATION. PROVIDE ALL HEiCE55ARY OFFSETS TO SUIT FIELD CONDITIONS AS REQUIRED. D. CONTRACTOR SHALL VERIFY AND COORDINATE ALL UTILITY CORRECTION POINTS, INCLUDING SIZES AND INVERTS HiTH EXI5TiN6 FIELD CONDITIONS PRIOR TO START OF WORK E. HAKE ALL UTILITY CON W71ONS AND INSTALLATION5 IN RILL ACCORDANCE WITH ALL UTILITY RE6UATION5. PROVIDE ALL ADDITIONAL APPURTENANCES AS REQUIRED BY UTILITY COMPANY. THE COMPLETED INSTALLATION SHALL 13E IN ACCORDANCE WITH ALL APPLICABLE INDUSTRY STANDARDS OF 6000 PRACTICE AND SAFETY, AND THE MANIFACTURER'S STRICTEST RECOMMENDATIONS FOR E GUIPMENT AND PRODUCT APPLICATION AND INSTALLATION. F. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, DOCUMENTS AND SERVICES RELATED TO THE INSTALLATION OF THE WORK 6. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL„ STATE AND LOCAL CODES, LAW5, ACTS, ALL AUTHORITIES HAVING JURISDICTION AND LANDLORD5 CRITERIA. H. MAINTAIN ALL MANIFAC7URER5 RECOMMENDED SERVICE CLEARANCES FOR ALL FIXTURE'S AND EQUIPMENT. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF PLUMBING FIXTURES. 1/2' DRAIN FROM TRAP PRIMER TYPICAL SANITARY STACK DIAGRAM SCALE: NOW PIPING. G. SHALL NOT BE INSTALLED UNLESS PEIRMITTED BY CODE. Si=WS2 AND VENT MATERIAL SHALL BE AS FOLLOWS: A. BELON 6RADE SANITARY INN5IDE'. BUIL-DIN6 1. PVG-DWV PLASTIC ASTM D -1185 WITH A57H D -2665 DWV SOLVENT WELD 50GKE7 FITTIN66. B. ABOVE GRADE VENTS AND SANITARY - 1. PVC-DWV PLASTIC, ASTM D -1185 NI7H ASTM D -2665 DWV SOLVENT WELD SOCKET FITTIN6 . NOTE: PVC, NOT PERMITTED WHERE NOTED ABOVE. CONTRACTOR MA ST VERIFY ALL CLEARANCES AND DIMENSIONS, IN FIELD C • McHENRY & ASSOCIATES, INC. CONSULTING ENGINEERS 25001 EMERY ROAD, SUITE #200 WARRENSVILLE HEIGHTS, OHIO 44128 Phone: (216) 292 -4696 Fax: (216) 292 -5874 Email: MAIL ®MCHENRYASSOCIATES.COM FLORIDA BUSINESS #0005282 Design and construction documents as Instruments of service are given In confidence and remain the property of Herschman Architects. The use of this design and these construction documents for purposes other than the specific project named herein Is strictly prohibited without expressed written consent of Hersohman Architects. Incorporated. Date Issue 05 -26-05 BID/'PERMIT • • • • • • • • Drawn By: WAR Project No.: 01161.00 ��✓.rifw.��! fl i 5 W Ileeee V J a W co Z � J LL _w co IL Q Q O� Z W F_ V TOa I- CO HERSCHMAN ARCHITECTS I N C O R P O R A T E D 25001 EMERY ROAD, SUITE 400 CLEVELAND, OH 44128 TEL (216) 223 -3200 FAX (216) 223 -3210 www.herschmanarchitects.com FLORIDA LICENSE N0. AA0003208 P 1 y" r €� .. M Design and construction documents as Instruments of service are given In confidence and remain the property of Herschman Architects. The use of this design and these construction documents for purposes other than the specific project named herein Is strictly prohibited without expressed written consent of Hersohman Architects. Incorporated. Date Issue 05 -26-05 BID/'PERMIT • • • • • • • • Drawn By: WAR Project No.: 01161.00 ��✓.rifw.��! fl i 5 W Ileeee V J a W co Z � J LL _w co IL Q Q O� Z W F_ V TOa I- CO HERSCHMAN ARCHITECTS I N C O R P O R A T E D 25001 EMERY ROAD, SUITE 400 CLEVELAND, OH 44128 TEL (216) 223 -3200 FAX (216) 223 -3210 www.herschmanarchitects.com FLORIDA LICENSE N0. AA0003208 P 1