Loading...
05-676-017N Q m m O i I I r �r -I -- I S- i11�. ►III: ►' I Ii \� Y.�.,t,�►__�— r ►!�_ -IJri I •i► .il� - I r 9 REMOVE 1= XI5TING :- III AIR HANDLING UNIT I AND RELOCATE AS • SHOWN ON PLAN ©© OPER. W. 4" L 9 RB,TOVE EXISTING AIR HANDLING UNIT AND RELOCATE AS SHOWN ON PLAN OPER. WT. T25f i I I r �r -I -- I S- i11�. ►III: ►' I Ii \� Y.�.,t,�►__�— r ►!�_ -IJri I •i► .il� - I r • :- III I :- • : - • : • r • • ©© I' iI iI I- �� • �� A.1 B C D I I I q REMOVE EXISTIN6 3 AIR HANDLING UNIT AND RELOCATE AS SHOWN ON PLAN (& F.2 WT F OPER. W. T — I- - - - NEW LOCATION OF EXI5TIN9 - - - - I I I O HOR . AIR HANDLING UNIT. HANG FROM DECK ABOVE OF WT 400. SET OA FOR 530 GFM I GTX 14x12 _ TI T 4. I I 0 I --A_ O I 4 I 4 30x16® 30x14 TWO POSITION 14 -- DAMPER INTERLOCK I I 4u.14ELEcTRI2. WITH FAN,, SEE SPECS 14x1 OA M HEAT, a 3OA2 OA I 'X' 5R- 1,18Xb \ / 5R-I, 18X6 O 440 CFM � \440 GFM 13CTX M �7 24xib OA I 8'0 TOILET EXHAUST TWO P051TION 14 I I I I DAMPER 82x22 WITH FAN, SEE SPECS 1 I ® I 150 GFM yr SET MIN 1 N9)1 LOCATION OF EXISTING I I TO 20 CFM SR—I, 18X6 \ _5R-I, 18* HORZ. AIR HANDLING UNIT. HANG FROM DECK 3 ao I W-3 8'0 440 GFM j 440 GFM ABOVE. OP WT rZk 3 I 150 GFM SET O 50 A FOR 14 GFM N 0 I 8 8 0 I I I �S X N STOCKROOM 12 J I f OFFICE' E I D.8 I I BAD. I I i G I I p I I GAB I 60x18 - 14x10 14x10 GL6 FAN I - Oj mr GTX WOMEN - -� I I � � I _ 24x1 OA 13 5R- 1, 14 \Xbl 54x16 SR I- 14X6 SR- I, 14Xb (4 O :r- PO5ITI BAD. 12-0 320 GFM 3Z0 GFM MD DAMPER GTX a 12 I I PiMi FAK SM SPECS PITCH � 6'0 TO r 4w 0 60x18 82x22 .�� noffl 44x30 5Ox16 I I A O' UPS I DN I6 2 CONNECTION -- TYP. FAN l I 54x16 ' J 1 j 12 .' ' GD3, 810 A44A3 T T I 3 I - - - - - -- 100 Cr-M 3OA2 OA CORRIDOR 2 i ` ! ` D-I, 24 G2, 'X' BAD. IL-0' 2 T 2 N&I LOCATION OF E 15TIN16 144x30 H16H 50X16 500 CFM AS POSSIBLE TRANSITION UNDER I HORZ AIR HANDLING 28x8 A DCT 2 T6 DU ABOVE SIPPLY I � ABOVE OP Kr 125#. SET OA FOR 1000 CFM L CD-2, 12X12 I 400 CFM I I � � SOO CFM I I I I0 O — - - - - - - - — - - - - - - - - - - - - - - - - - - - - - - - O I I r GD -I, 24'0 GD-I, 24'0( i I _ AF E- id 500 GFM 800 GFM ��/ ! � I I I' CD-2,12A2 I I MECHANICAL FLOOR PLAN 500 GFM- - - I —► -- - - - - - I I I/8.. _ 1 -0.. I -- - f - JZ IF�q - - - - -- - - - -- - -- - - •- 28x10 28x14 I i i 28x12 I 28x16 I 6 TYP I I * 1000 G I ' x x j CD-I, 24'40 GD 2,12X12 i GD-2, FM 100 GFM I 500- GFM GALLEI 1Y - - - -- _ J 20x8 DUCT TYP. 2 7 -- — — — — — — — — — — — — — — — — — — - -08 SR- 1,14x6 311 - -- - - -- -- 300 CFM x I GD-2, I6 161 C 7A 24' : -' 560 Al I 500 Z:J Lit I 6 TYP. I I SALES AREA 28x8 I 1� 28x12 t I 20x6 GD CO-1, 24.0 GEM, 24'0 800 GFM I GD- 2,1646, I 1100 C Ixl I 10 550 GFM ASR- 1,14x6 • 300 C4--M - - - - -- -- -- - - -- - - - -- I- - - -� \ I -- - -- - - - - - -- -- - -- -- I - - -- . i I I CD-I, 24'0 420 CFM I I ! ' _ �xA I l i kx 1 0 500 GFM -0M- C I MVD, TYP. �__ _ - - - -- - - -- - - - - - I I \ I I I I I I FZIOVE EXI5T1N6 AIR HANDLING LNIT NffCHANIca DUCTWORK FLOOR PLAN GOom NOTES O 1 MOUNTS 'TEMPERATURE SENSOR AT 54' ABOVE FINISHED FLOOR. COORDINATE MOUNTING LOCATION OF TB•PERATURE 5EL50R WITH TBJ/WT AND ARCHITECT PRIOR TO R0U6H -IN. 2 MOUNT THERMOSTATS ON WALL IN MANAGER'S OFFICE AT 54' ABOVE FINISHED FLOOR MAXIMUM, BE-1IND DOOR SWING. COORDINATE EXACT MOUNTIN6 LOCATIONS OF T}19;tNiOrTAT'S WITH TENANT AND ARCH17 GT PRIOR TO ROU6H -IN. 3 SUSPEND AIR HANDLING UNIT WITH VIBRATION SPRIN65 ON SUSPEIVEP STEEL. FRAME FURNI5HED BY 6E',NERAL CONTRACTOR. REFE3R TO AIR HANDL.IN6 UNIT INSTALLATION DETAIL ON DRAWING H2. 4 DASHED LINE INDICATES In ACOUSTIC LINING. DUCT DIMEN5ION5 ARE EXTERIOR AND INCLUDE LINING -- TYPICAL. 5 EXTEND TOILET ROOM BWAUST AIR DUCTWORK AND CONNECT TO LANDLORD'S EXHAUST AIR DUCTWORK. VERIFY B"T LOCATION IN FIELD. b KEEP BOTTOM OF DUCT FLAT IN SA1E5 AREA. TRANSFORM AT TOP OF DUCT ONLY. MOUNT' BOTTOM OF DUCTS IN SALE5 AREA AT 12'-O' A.F.F. DUCTWORK IN SALE'S AREA SHALL HAVE PAINT 6RIP FINISH. TYPICAL T PROVIDE OPENING IN TOP OF RETURN AIR DUCT WITH OPEN AREA EC,I,UAL TO 1 -1/2 TIMES THE DUCT CROSS-SECTIONAL AREA. 8 10x6 AIR IR46FER DUCT CONNECTED TO 6RILLE 6-1 IN CEILIN6 IN NANA6ER'S OFFICE AND TO 6-2, 10x6 IN WALL IN STOCK ROOM AS HIGH AS POSSIBLE A.F.F. INLSTALL 1/2' ACOUSTIC LINING IN AIR TRANSFER DUCT. 9 DISC0IsW:CT E ISTIN6 AIR MANDLIN6 UNIT FROM ALL DUCTWORK, PIPING, WIRINIG, M. AND RELOCATE UNITS TO NEW LOCATION AS SHOWN ON DRAWIN6. GAP ALL PIPIN6 AND BLANK -OFF OUTSIDE AIR DUCT AIR TIGHT. ALL DUCTWORK, PIPING, M. LEFT TO LANDLORD NOT REQUIRED TO BE REMOVED FOR ACGE55 TO UNIT RELOCATION ARE TO REMAIN AS 15 FOR FUTURE 'TENANT. SMOKE DETECTORS 94ALL BE RELOCATED WITH UNIT. 10 ALL TYPE GD /1 DIFFUSERS IN 5ALE5 AREA SHALL BE SAME TYPE AND SIZE WITH NECK SIZE AS SHOWN ON PLANS. NO OTHER SIZE DIFFUSERS WILL BE PERMITTED. TYPICAL. 11 RRICIVE EXISTIN5 UNIT WITH ALL RELATED DUGTWORK, PIPING WIRING, ETC. SEE DRAWIN6 M2 FOR PIPN6 WORK. 12 NECI-IANICAL CONTRACTOR SHALL RB..00.ATE EXISTING SMOKE DETECTOR WITH UNIT. ELECTRICAL CONTRACTOR SHALL WIRE THE SUPPLY AIR SMOKE DETECTOR WITH REMOTE TEST 5WITCH AND ALARM TO 5HI1` DOiN UNIT UPON ALARM. ALL WIRING SHALL BE IN CO"IT PER N.E.G. SMOKE DETECTOR AUXILIARY CONTACTS SHALL. BE WIRED TO FIRE ALARM CONTROL. PANT BY ELECTRICAL GONTRACTOR. MECHANICAL CONTRACTOR SHALL CONFIRM PROPER OPERATION OF SMOKE DETECTOR IN SUPPLY AIR DUCT. IF SMOKE DETECTOR I5 NOT OPERATIN6 CORRECTLY, A HEN SMOKE DETECTOR SHALL 13E FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR TO SHUT DOWN UNIT UNDER ALARM CONDITIONS. 13 EXTEND OUTSIDE AIR DUCT AND COMEGT TO EXISTING LANDLORD F1RNI5FED OUTSIDE AIR DUCT. VERIFY EXACT LOCATION IN FIELD. TYPICAL. 14 MOTORIZED, TWO POSITION, OUTSIDE AIR DAMPER INTERLCIC.KED WITH UNIT SUPPLY AIR FAN BY E.G. - TYPICAL CONTRACTOR 146T VERIFY ALL GLEARANIGES AND DIM1EN510N5 IN FIELD C • McHENRY & ASSOCIATES, INC. CONSULTING ENGINEERS 25001 EMERY ROAD, SUITE #200 WARRENSVILLE HEIGHTS, OHIO 44128 Phone: (216) 292 -4696 Fax: (216) 292 -5874 Email: MAIL @MCHENRYASSOCIATES.COM FLORIDA BUSINESS #0005282 JI * _ I Design and construction documents as Instruments of service are given h confldance and remain the property of Herschmen Architects. The use of this design and those construction documents for purposes other than the specific project named herein Is strictly prohibited without expressed written consent of Hersohman Architects. Incorporated. Date I Issue 03 -26-05 SID/PERMIT • • • • • • • • Drawn By: XXX Project No.: 9181.00 W V J `L LU r co Z Cf) J LL Q = Q Q CO) 2 W W D Q HERSCHMAN ARCHITECTS IN C O R P O R A T ED 25001 EMERY ROAD, SUITE 400 CLEVELAND, OH 44128 TEL (216) 223 -3200 FAX (216) 223 -3210 www.herachmanarchitacts.com FLORIDA LICENSE N0. AA0003208 M 1