05-370-001� � 1 Q CL ° A -133 A -137 CORRIDOR uP NORTH FIRE ALARM PLAN SUITE 0415 SCALE: 1/8"=1'-O" REVISION # 1: 0 -ADDED STROBE IN EMPLOYE'S BATH - ADDED SPEAKER /STROBE BEHIND BAR 1 J N 7 5cd 2 attt WP BRIDGE ABOVE �% _ BAR 3 016 .d At 1 J REETER FIRE ALARM NOTES 1- Fire Alarm System shall be U.L. listed and NFPA 72 approved. 2- All wiring and conduit size shall be in accordance with manufacturer recommendation, NEC, local codes and NFPA. Maximum conduit fills to be 40 %. Minimum raceway size Y2 ". 3- All conductors shall be copper. 4- Riser interconnections are diagrammatic only. 6- Fire Alarm System to be "Power Limited". 6- Visual Alarm per ANSI A117.1, 4.26, SFBC 613.3 and ADA approved. Null mounts 80" A.F.F. to button of Strobe lens. 7- All N .A.C. hiring shall be class "B° (Style "Y"). Initiating circuit airing shall be Class "B" (Style "4 "). 8- The system shall have battery back up for 24 hrs in standby mode and 16 minutes in alarm. 9- The installation shall comply with NFPA 70 Chapter 760. 10- Strobe light circuits shall be synchronized. 11- Speaker /Strobes and Strobe light shall be located as per NFPA 72 Chapter 4. 12- Existing system is classified as Protected Premises Fire Alarm System. 13- All ceiling heights d'b not exceed 10' -0" and all ceiling are flat. 14- All new devices shall be tied to the existing panel. 16- The existing Fire Alarm Control Panel FIRE -LITE MS -9200 is ,.a fully addressable fire alarm system with 198 device capacity (99 detectors and 99 monitor control module). "SUBJECT TO- FIELD INSPECTION" FIRE ALARM SYSTEM PAGE SEQUENCE OF OPERATION The actuation of the fire alarm initiating device shall automatically initiate the function detailed below, A. MANUAL FIRE ALARM PULL STATION Activation of the Manual Fire Alarm Pull Station shall initiate the following functions: 1- Generate an audible alarm signal at the Fire Alarm Control Panel. 2- Generate a visual and audible alarm signal simultaneously on all areas of the building by means of Strobe and Speaker /Strobe notification devices. 3- Indicate the location of the Pull Station by displaying, in English, the alarmed device and its location on the FRCP alphanumeric display. 4- Shut off the Sound System thru Addressable Relay 8104. B. SMOKE DETECTORS Activation of Smoke Detectors shall initiate the following functions: 1- Generate an audible alarm signal at the Fire Alarm Control Panel. 2- Generate a visual and audible alarm signal simultaneously on all areas of the building by means of Strobe and Speaker /Strobe notification devices. 3- Indicate the location of the Smoke Detector by displaying, in English, the alarmed device and its location on the FRCP alphanumeric display. 4- Shut off the Sound System thru Addressable Relay 8104. C. DUCT DETECTORS Activation of Smoke Duct Detectors shall initiate the following functions: 1- Generate an audible Supervisory signal at the Fire Alarm Control Panel. 2- Indicate the location of the Smoke Duct Detector by displaying, in English, the activated device and its location on the FRCP alphanumeric display. 3- Shut off the air handling unit and A/C equipment associated with the duct detector. D. Each Signaling Line Circuit and Notification Appliance Circuit shall be electrically supervised for opens shorts and ground faults. The occurrence of any fault shall activate the trouble circuitry but shall not interfere whit the proper operation of any circuit that does not have a fault condition. FIRE ALARM LEGEND SYMBOL DESCRIPTION MANUFACTURE MODEL FACP FIRE ALARM CONTROL PANEL FIRE —LITE MS -9200 FAAP FIRE ALARM ANNUNCIATOR PANEL FIRE —LITE LCD -40 RFI`S�g�FCT to EVAC VOICE EVACUATION CONTROL PANEL EVAX SYSTEMS EVAX 25 INSPFCTION„ SM SYNC. MODULE MIRCOM SYSTEM SENSOR WHEELOCK D * DSM -12/24 ADDRESSABLE RELAY MODULE SPEAKER STROBE -- - -- © PULL STATION - - -- -- FIRE -LITE -- - - - - - - -- - - - - - -- - — - - - - -- - - -- SPEAKER STROBE WEATHER PROOF BG -12LX - - - - - -- -- - -- -- - - - - -- - -- - - - NAM1 -DADS CO. FIRE DEPAK ET70WP- 2475W -FR APPLICATION #05350- SD ADDRESSABLE SMOKE DETECTOR NEW FIRE LITE 3 SD350 SMOKE DETECTORS HD HEAT DETECTOR DUCT DETECTOR MIRCOM SYSTEM SENSOR -- - - - - -- - - - - -- - -- - - - --- - - - - -- - - -- - - -- - - - -- - -- MIR -600 - --- - — - - -- - -- -- - — REVISED' DH 10OAC6CLP PLANS D * ® ADDRESSABLE RELAY MODULE SPEAKER STROBE -- - -- I FIRE —LITE WHEELOCK CRF -300 AIDFR E50- 24MCW -FR ' - - -- -- - �WP -- - - - - - - -- - - - - - -- - — - - - - -- - - -- SPEAKER STROBE WEATHER PROOF - - - - -- - - -- - - - - -- -- -- WHEELOCK - - - - - -- -- - -- -- - - - - -- - -- - - - NAM1 -DADS CO. FIRE DEPAK ET70WP- 2475W -FR APPLICATION #05350- STROBE LIGHT WHEELOCK RSS- 24MCW -FR * DEVICE MONITORED WITH MINI MONITOR MODULE FIRELITE MMF -301 SCOPE OF WORK: 1. FURNISH AND INSTALL DEVICES TO EXISTING SYSTEM AS FOLLOWS: QTY DESCRIPTION 1 NEW REMOTE ANNUNCIATOR PANEL 1 NEW VOICE EVACUATION CONTROL PANEL 13 NEW STROBES LIGHT 3 NEW SMOKE DETECTORS 8 NEW SPEAKERS /STROBE 2 NEW HEAT DETECTORS 3 NEW PULL STATION 3 NEW DUCT DETECTORS 5 - - -- -- NEW -- ADDRESSABLE RELAY MODULE --- - - - - -- -- ----------- - - - -- - - - - - -- -- - - - - -- I FIRE ALARM SYS -1EM To? N: DENOTE NEW DEVICE INSTALLED IN ACCORDANCE WITH ER : DENOTE EXISTI.t. D EE.L . 101 - MIAN H -DADIE 1COUNTY FIkt DEPAIif �f BLDG. PERI►Ili 0I14E ALARM ✓ . FIRE SUPPREr6I0N_ N DATE.0 -1 07.05 w. - 0 FLORIDA EIRE & BURGLARY EF #0000818 2450 WEST 82ND STREET UNIT 105 Miami, FL 33016 Office: (305)362 -5276 Fax: (305)362 -5208 Cellular: (305)884 -3543 E -mail: flburg @bellsouth.net 8 yj 4 ' ,..� rte,►. •• '. ry_r C � � � gyro .•' { °'.s� 3 C3 4k CL E m o%: a m� cam' '$ r.LL : -kr of ono REVISIONS O Z I- W cn L LJ LCD � LL Q�- 0�Q => L..LJ ' C/7 �- �00 I--- C/� Ln Q Q OJECT NO.: DRAWING NO.: SCALE: 1/8" = 1' -0" DATE: 06/28/05 DRAWN BY: I.M. ISSUED: FOR PERMIT SHEET NO.: FA -01 01 OF 02