Loading...
04-04-041I 3 I . t HVAC LEGEND ABBREVIATION /DEFINITION 0 M_ DETAIL NUMBER DRAWING WHERE SHOWN AAV X ::]OE TERMINATED OPEN -ENDED DUCT EXTERNAL STATIC PRESSURE EQUIPMENT DESIGNATION NECK SIZE ® 24'X24' CEILING DIFFUSER RTU EWT ENTERING WATER TEMPERATURE CFM 4 -WAY THROW UNLESS NOTED OTHERWISE N0. ACCESS DOOR EXH EXHAUST O.A. OUTSIDE AIR EQUIPMENT NAME ADJUSTABLE ® -•�s� 24 "X24" RETURN AIR GRILLE OBD EQUIPMENT NUMBER AFF ABOVE FINISHED FLOOR FA xi R--p- T7 DUCT RISE IN DIRECTION OF ARROW ON CENTERS 24 "X12" RETURN AIR GRILLE DUCT DROP IN DIRECTION OF 'ARROW FREE AREA SLOT DIFFUSER OPEN -END SECTION CUT LINE AMBIENT FCU FAN COIL UNIT OPNG OPENING APPROX APPROXIMATE FD SIDEWALL DIFFUSER WITH PLBG SECTION NUMBER ARCH ARCHITECT FL MULTI -VANE DEFLECTOR PRV DRAWING WHERE SHOWN BD BACKDRAFT DAMPER FLEX FLEXIBLE PSIA TEMPERATURE SENSOR BHP PLENUM OVER CEILING l�J FACE E OPERATED DAMPER P SIG POUNDS R S . IN. GAUGE P PER Q MOUNTED LINEAR DIFFUSER O THERMOSTAT 0X00 DOOR GRILLE AND SIZE HO HUMIDISTAT INCHES DOOR UNDERCUT AND AMOUNT FIRE /SMOKE DAMPER RAG L.S. BTUH BRITISH THERMAL UNIT HOUR CONTROL PANEL FEET RAR LOUVER AND SCREEN C TO C CENTER TO CENTER FTL SQUARE FEET REG ROUND DUCT SECTION CAP CAPACITY ROOF MOUNTED CENTRIFUGAL FAN GAUGE OR GAGE RH RELATIVE HUMIDITY CD CEILING DIFFUSER GAL GALLONS DUCT SECTION NEGATIVE PRESSURE ROTATIONS PER MINUTE u LJ CUBIC FEET PER MINUTE I UNIT HEATER - HORIZONTAL ® DUCT SECTION POSITIVE PRESSURE CLG CEILING GR GRILLE S.A. SUPPLY AIR UNIT HEATER - VERTICAL CLEANOUT HD 0Ox00 DUCT SIZE - FIRST FIGURE IS SIDE SHOWN SMOKE EXHAUST COMP COMPRESSOR HP ACCESS DOORS VERTICAL OR HORIZONTAL SG UNIT HEATER - WALL MOUNTED CONC CONCRETE HR WH SP STATIC PRESSURE (IN. W.G.) MANUAL DAMPER OPPOSED BLADE CONDENSATE H/C FD FIRE DAMPER (SINGLE LINE DUCT SYMBOLS) SD SMOKE DAMPER IN FIRE DAMPER WITH DUCT ACCESS DOOR SQ TWO HOUR ENCLOSURE AROUND DUCT CONT LINED DUCTWORK Z= FLEXIBLE DUCT CONNECTION SR I L MANUAL DAMPER CONTROL PANEL DUCT MOUNTED SMOKE DETECTOR KILOWATT HOUR DUCT ELBOW WITH DOUBLE THICKNESS TURNING VANES STAINLESS STEEL CU CONDENSING UNIT LAT LEAVING AIR TEMPERATURE STIR STRUCTURAL TYPICAL 900 LOW PRESSURE DUCT ELBOW (FURNISH AND INSTALL DOUBLE THICKNESS CONDENSER WATER DUCT TEE CONNECTIONS WITH SPUTTER DAMPER POUNDS TD TURNING VANES NOT SHOWN). C C COOLING COIL LF LINEAR FEET TYPICAL 45' LOW PRESSURE DUCT ELBOW TEMPERATURE BRANCH TAKE -OFF WITH SPUTTER DRAIN (TURNING VANES NOT REQUIRED). LINEAR RETURN AIR GRILLE TG DAMPER OR VOLUME EXTRACTOR DB DRY BULB LWT DUCT TRANSITION REDUCTION IN TRANS TYPICAL LOW PRESSURE SUPPLY TEE dB DECIBEL SIZE IN DIRECTION OF ARROW LOUVER & SCREEN CONNECTION (FURNISH AND INSTALL TYPICAL DG DOOR GRILLE MAX FLEXIBLE RUNOUT WITH SPIN -IN T'STAT DOUBLE THICKNESS TURNING VANES, AND SPLITTER DAMPER SEE DETAILS). DIA DIAMETER MBH 1000 BTU /HOUR UH FITTING AND MANUAL DAMPER DIFF TYPICAL LOW PRESSURE SUPPLY TAKE R� RISE IN DIRECTION OF ARROW UNO OFF (FURNISH AND INSTALL SPUTTER DN DOWN MIN MINIMUM VAV VARIABLE AIR VOLUME UNIT DAMPER NOT SHOWN SEE DETAILS). DRAWINGS MOD MOTOR OPERATED DAMPER VB VACUUM BREAKER E.A. EXHAUST AIR DROP IN DIRECTION OF ARROW MOUNTED VEL -� - ° ----❑M MOTOR OPERATED DAMPER ENTERING AIR TEMPERATURE TYPICAL LOW PRESSURE RETURN OR NOISE CRITERIA VFD VARIABLE FREQUENCY DRIVE EF EXHAUST TAKE OFF (SEE DETAILS). NIC NOT IN CONTRACT WB WET BULB EG EXHAUST GRILLE ® VIBRATION ISOLATOR HVAC ABBREVIATIONS ABBREVIATION /DEFINITION ABBREVIATION /DEFINITION ABBREVIATION /DEFINITION AAV AUTOMATIC AIR VENT ESP EXTERNAL STATIC PRESSURE N.C. NORMALLY CLOSED AC ABOVE CEILING EWT ENTERING WATER TEMPERATURE N.O. NORMALLY OPEN AD ACCESS DOOR EXH EXHAUST O.A. OUTSIDE AIR ADJ ADJUSTABLE Fs DEGREES FAHRENHEIT OBD OPPOSED BLADE DAMPER AFF ABOVE FINISHED FLOOR FA FACE AREA OC ON CENTERS ALT ALTITUDE FA FREE AREA OE OPEN -END AMB AMBIENT FCU FAN COIL UNIT OPNG OPENING APPROX APPROXIMATE FD FIRE DAMPER PLBG PLUMBING ARCH ARCHITECT FL FLOOR PRV PRESSURE REDUCING VALVE BD BACKDRAFT DAMPER FLEX FLEXIBLE PSIA POUNDS PER S Q . IN. ABSOLUTE BHP BRAKE HORSEPOWER FOD FACE E OPERATED DAMPER P SIG POUNDS R S . IN. GAUGE P PER Q BOT BOTTOM FPM FEET PER MINUTE R.A. RETURN AIR BTU BRITISH THERMAL UNIT FSD FIRE /SMOKE DAMPER RAG RETURN AIR GRILLE BTUH BRITISH THERMAL UNIT HOUR FT FEET RAR RETURN AIR REGISTER C TO C CENTER TO CENTER FTL SQUARE FEET REG REGISTER CAP CAPACITY GA GAUGE OR GAGE RH RELATIVE HUMIDITY CD CEILING DIFFUSER GAL GALLONS RPM ROTATIONS PER MINUTE CFM CUBIC FEET PER MINUTE GPM GALLONS PER MINUTE RTU ROOF TOP UNIT CLG CEILING GR GRILLE S.A. SUPPLY AIR CO CLEANOUT HD HEAD SE SMOKE EXHAUST COMP COMPRESSOR HP HORSEPOWER SG SUPPLY GRILLE CONC CONCRETE HR HOUR SP STATIC PRESSURE (IN. W.G.) COND CONDENSATE H/C HEATING COIL SPEC SPECIFICATION CONN CONNECTION IN INCHES SQ SQUARE CONT CONTINUATION KW KILOWATT SR SUPPLY REGISTER CID CONTROL PANEL KWH KILOWATT HOUR SS STAINLESS STEEL CU CONDENSING UNIT LAT LEAVING AIR TEMPERATURE STIR STRUCTURAL CW CONDENSER WATER LBS. POUNDS TD TEMPERATURE DIFFERENCE C C COOLING COIL LF LINEAR FEET TEMP TEMPERATURE D DRAIN LRAG LINEAR RETURN AIR GRILLE TG TRANSFER GRILLE DB DRY BULB LWT LEAVING WATER TEMPERATURE TRANS TRANSITION dB DECIBEL L&S LOUVER & SCREEN TYP TYPICAL DG DOOR GRILLE MAX MAXIMUM T'STAT THERMOSTAT DIA DIAMETER MBH 1000 BTU /HOUR UH UNIT HEATER DIFF DIFFUSER MD MANUAL DAMPER UNO UNLESS NOTED OTHERWISE DN DOWN MIN MINIMUM VAV VARIABLE AIR VOLUME UNIT DWGS DRAWINGS MOD MOTOR OPERATED DAMPER VB VACUUM BREAKER E.A. EXHAUST AIR MTD MOUNTED VEL VELOCITY EAT ENTERING AIR TEMPERATURE NC NOISE CRITERIA VFD VARIABLE FREQUENCY DRIVE EF EXHAUST FAN NIC NOT IN CONTRACT WB WET BULB EG EXHAUST GRILLE NOM NOMINAL WC WATER COLUMN EL ELEVATION NO. NUMBER OR DESIGNATION WG WATER GAUGE ENGR ENGINEER NPSHA NET POS. SUCTION HD AVAIL W/ WITH ENT ENTERING NTS NOT TO SCALE ZBD ZERO LEAKAGE BACKDRAFT DAMPER ER EXHAUST REGISTER N/A NOT APPLICABLE % PERCENT GENERAL NOTES 1. INSTALL EQUIPMENT AND MATERIALS IN COMPLIANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. COMPLY WITH THE LATEST ADOPTED VERSION OF THE NFPA 90A AND THE FLORIDA STATE MECHANICAL AND PLUMBING CODES. 3. ALL MATERIALS SHALL FIT THE SPACE AVAILABLE. VERIFY DIMENSIONS AND CLEARANCES AT BUILDING SITE PRIOR TO COMMENCING WORK. 4. CONTRACTOR IS RESPONSIBLE FOR TESTING AND BALANCING OF AIR AND HYDRONIC SYSTEMS IN ACCORDANCE WITH AABC AND NEBB GUIDELINES. A TEST AND BALANCE REPORT SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL. 5. THE CONTRACTOR SHALL FULFILL ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SHALL COMPLETE THE IMPROVEMENTS SHOWN ON THESE DRAWINGS. ALL SYSTEMS SHALL BE FINISHED, TESTED AND BALANCED, ADJUSTED, AND PROVEN TO BE FULLY OPERATIONAL AND USEABLE. 6. WHERE PIPES, CONTROL DEVICES AND WIRING WHICH ARE TO REMAIN IN SERVICE ARE DISCONNECTED FOR THE REMOVAL OR RELOCATION OF EQUIPMENT OR BECAUSE OF BUILDING ALTERATIONS, THEY SHALL BE RECONNECTED. 7. GAUGES AND CONSTRUCTION FOR DUCTWORK SHALL CONFORM TO SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS. 8. TRANSITION RECTANGULAR DUCTWORK ON BOTTOM AND SIDES. MAINTAIN TOP OF DUCTWORK LEVEL AND AS HIGH AS POSSIBLE. 9. FLEXIBLE DUCT RUNOUTS TO CEILING DIFFUSERS SHALL BE AS STRAIGHT AS POSSIBLE AND FREE OF SAGS & KINKS. FLEX DUCT SHALL BE THE SAME SIZE AS THE DIFFUSER NECK IT SERVES. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 7' -0 ". 10. ALL DUCT TRANSITIONS FROM SQUARE TO ROUND SHALL BE SMOOTH SQUARE TO ROUND TRANSITIONS. SPIN -IN FITTINGS AT THE END OF CAPPED DUCTS ARE NOT ACCEPTABLE. 11. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS. 12. PORTIONS OF DUCTWORK VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. 13. PROVIDE 45 DEGREE BRANCH TAKE -OFF PER SMACNA FIG. 2 -8 ON ALL NEW RECTANGULAR DUCT TAKE OFFS. 14. ALL VALVES, FANS AND DAMPERS ABOVE CEILING SHALL BE ACCESSIBLE. CONTRACTOR SHALL COORDINATE ALL ACCESS PANELS IN CEILINGS OR WALLS WITH ARCHITECTURAL REFLECTED CEILING PLANS FOR PROPER LOCATION. 15. NOT USED 16. ADJUST ALL DIFFUSERS IN CORRIDORS OR WITHIN THREE (3) FEET OF A WALL TO PROVIDE 2 -WAY OR 3 -WAY BLOW AWAY FROM OR PARALLEL TO WALLS. ALL LAY -IN DIFFUSERS SHALL HAVE 4 -WAY BLOW UNLESS NOTED OTHERWISE. 17. CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF EACH PIECE OF EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING. 18. MOUNT THERMOSTATS AND FAN SWITCHES WHERE INDICATED ON PLANS 5' -0" A.F.F. 19. COORDINATE DUCTWORK AND PIPING WITH PLUMBING, FIRE PROTECTION AND ELECTRICAL. MAKE OFFSETS AND TRANSITIONS TO COORDINATE WITH OTHER TRADES WITHOUT ANY ADDITIONAL EXPENSE TO THE CONTRACT. 20. VISIT SITE AND CAREFULLY EXAMINE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. NO ALLOWANCE WILL BE MADE FOR LACK OF KNOWLEDGE OF EXISTING CONDITIONS. 21, ALL WIRING AND CONTROL TUBING IN THE CEILING PLENUM SHALL BE PLENUM RATED CABLE OR TUBING. 22. AN IONIZATION TYPE SMOKE DETECTOR FOR UNIT SHUTDOWN SHALL BE INSTALLED IN THE SUPPLY OF EACH RTU OF 2000 CFM OR GREATER. 23. PROVIDE SCHEDULE 40 STEEL SLEEVES AND FIRE RETARDANT SEALANT FOR PIPE PENETRATIONS THRU FLOOR OR ROOF SLAB. 24. PROVIDE INTERNAL LINER (1" THICK, 1 1/2 LB DENSITY) THROUGH THE FIRST TAKE -OFF FOR SUPPLY DUCTS. INSULATE ALL NON -LINED AIR DUCTWORK WITH 2" THICK, FOIL- BACKED, 3/4 LB. DENSITY BLANKET INSULATION. HOLD DUCTWORK INSULATION IN PLACE WITH FOIL FACED TAPE AND STAPLES. EXPOSED DUCTWORK SHALL BE INTERNALLY INSULATED AND SUITABLE FOR PAINTING. 25. SUBMIT SHOP DRAWINGS ON THE FOLLOWING ITEMS IN SUFFICIENT QUANTITY TO PROVIDE TWO FILE COPIES FOR THE ARCHITECT: AIR HANDLING UNITS EXHAUST FANS GRILLES, REGISTERS AND DIFFUSERS LOUVERS, SMOKE CONTROL PANEL AND ALL BMS CONTROL COMPONENTS, INCLUDING DIAGRAMS AND SEQUENCE OF OPERATIONS 26. REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS AND CONNECTION TO ALL ELECTRICAL EQUIPMENT. 27. TRAP AND ROUTE CONDENSATE DRAINS LINES,FULL SIZE OF UNIT CONNECTION, AS INDICATED. SLOPE 1/8- PER FOOT DOWN IN THE DIRECTION OF FLOW AS INDICATED. INSULATE WITH 2" THICK PRE - FORMED FIBERGLASS PIPE INSULATION. CONDENSATE PIPING TO BE TYPE "M" COPPER ONLY. GRILLES, REGISTERS, DIFFUSERS MARK EXHAUST FAN SCHEDULE HANDLING UNIT SCHEDULE THROW NCX MAX CFM FINISH NOTES FAN DATA SUPPLY OPER. COOLING COIL DATA 4 -WAY MISCELLANEOUS TAG O.A. SERVICE CFM (�N.) ' DRIVE FAN HP WATER WT. TYPE LOCATION BASIS OF DESIGN REMARKS PLAN AREA MARK DIFFUSER SERVED AIR FLOW R.P.M. S.P. H'P' (LBS) COOLING DB /WB DB /WB FLOW EF -1D PD 3 D TRANE MODEL N0. rr 1 I T 6 B (CFM) 30 DOWNBLAST 35 E COOK ACE -100 1 EF -140 ('F) NOT USED 24X24 (FT) DIFFUSER 4 -WAY 35 820 OFF -WHITE 1 1.0 35 1,2,3&4 EF -15D 1ST LEVEL CIRCUIT TRAINING KI KLUB TOILETS 205 1 4' DIRECT 1420 6 EXHAUST 90 INLINE ABOVE CEILING LO EN COOK 90 -SQ 100 4 REMARKS: 400 1.0 3 1 PROVIDE COMPLETE WITH DISCONNECT SWITCH, BACKDRAFT DAMPER, INSULATED ROOF CURB AND SOLID STATE SPEED CONTROL. 2 LOCATE FAN ON EXISTING EF -1D CURB. MODIFY EXISTING CURB AS REQUIRED TO ACCOMMODATE NEW FAN. 3 PROVIDE COMPLETE WITH 8" PRE - FABRICATED ROOF CURB WITH 2" THERMAL INSULATION, NEMA 3R DISCONNECT SWITCH. FAN TO BE UL LISTED AS A "POWER VENTILATOR FOR SMOKE CONTROL SYSTEMS" 60X6 4 PROVIDE COMPLETE WITH DISCONNECT SWITCH, BACKDRAFT DAMPER, SPRING TYPE ISOLATORS AND SOLID STATE SPEED CONTROL. GRILLES, REGISTERS, DIFFUSERS MARK FUNCTION AIR HANDLING UNIT SCHEDULE THROW NCX MAX CFM FINISH NOTES FAN DATA SUPPLY 12X12 COOLING COIL DATA 4 -WAY MISCELLANEOUS SUPPLY O.A. EXT. MOTOR TOTAL SENSIBLE ENT. AIR LVG. AIR WATER MAX. WTR NO. of 1 C PLAN AREA MARK DIFFUSER SERVED AIR FLOW AIR FLOW S.P. H'P' COOLING COOLING DB /WB DB /WB FLOW 4 -WAY PD ROWS TRANE MODEL N0. NOTES E SUPPLY 2024 (CFM) (CM) (INCHES) 35 (MBH (MBH 'F) ('F) (GPM) 24X24 (FT) DIFFUSER 4 -WAY 35 820 OFF -WHITE 1 1.0 35 1,2,3&4 VAV 5 -3 1ST LEVEL CIRCUIT TRAINING 3000 450 14"0 0.4 1.0 G EXHAUST 12X10 10X8 AHU -9D - KID'S KLUB 2,000 400 1.0 3 82.8 56.2 78/66 1 52/52 26 0.3 8 6 BCHB 072 1,2,3,4 SUPPLY 62X8 60X6 DRUM 1 30 1600 OFF -WHITE 7 • • • o wowr •vw•• RETURN IRAN 12X12 10X10 DIFFUSER - 35 1 OFF -WHITE 2 J RETURN TRAN 24X24 1 DIFFUSER NOTES: 31 800 OFF -WHITE 2 K RETURN TRAN 1. COOLING CAPACITIES BASED ON 457 ENTERING CHILLED WATER AND 557 LEAVING CHILLED WATER TEMPERATURE. 30 2. ELECTRICAL REQUIREMENTS ARE 460V \3 PHASE \60 HZ. OFF -WHITE 2 L 3. PROVIDE COMPLETE WITH 3 -WAY CONTROL VALVE AND FLOW SETTING VALVE ON RETURN PIPING, BALL VALVE AND STRAINER ON SUPPLY PIPING AND A BALANCE FITTING IN BYPASS PIPING. UNIT CONTROLS TO BE PROVIDED TO CONNECT TO EXISTING TRANS BMS SYSTEM. 4. PROVIDE COMPLETE WITH (0 K ELECTRIC HEATER. 1 L1 RETURN TRAN 48X24 46X22 GRILLES, REGISTERS, DIFFUSERS MARK FUNCTION FACE SIN) NECK (IN) TYPE THROW NCX MAX CFM FINISH NOTES A SUPPLY 12X12 6" DIFFUSER 4 -WAY 36 220 OFF -WHITE 1 B SUPPLY 24X24 8" DIFFUSER 4 -WAY 1 32 275 OFF -WHITE 1 C SUPPLY 24X24 10" DIFFUSER 4 -WAY 33 400 OFF -WHITE 1 D SUPPLY 2024 12" DIFFUSER 4 -WAY 35 550 OFF -WHITE 1 E SUPPLY 2024 14" DIFFUSER 4 -WAY 35 665 OFF -WHITE 1 F SUPPLY 24X24 16" DIFFUSER 4 -WAY 35 820 OFF -WHITE 1 1.0 35 1,2,3&4 VAV 5 -3 1ST LEVEL CIRCUIT TRAINING 3000 450 14"0 0.4 1.0 G EXHAUST 12X10 10X8 GRILLE - 35 150 OFF -WHITE 8 1,2,3884 VAV 5 -5 MEN'S LOCKER 2000 325 12 "0 0.3 1.0 35 1,2&3 H SUPPLY 62X8 60X6 DRUM - 30 1600 OFF -WHITE 7 • • • o wowr •vw•• RETURN IRAN 12X12 10X10 DIFFUSER - 35 500 OFF -WHITE 2 J RETURN TRAN 24X24 1 2X1 2 DIFFUSER - 31 800 OFF -WHITE 2 K RETURN TRAN 24X24 18X18 DIFFUSER - 30 1800 OFF -WHITE 2 L RETURN ARAN 24X24 22X22 DIFFUSER - 33 2200 OFF -WHITE 2 L1 RETURN TRAN 48X24 46X22 DIFFUSER - 33 4400 OFF -WHITE 2 2 IRETURNZTRAN 62X22 6OX20 DIFFUSER - 33 4400 OFF -WHITE 8 3 SMOKE EXHST 44X26 42X24 GRILLE - 40 5000 OFF -WHITE 10 4 SMOKE EXHST 38X38 36X72 GRILLE - 40 10,000 OFF -WHITE 11 Q5 SMOKE EXHST 4026 42X24 GRILLE - 40 10,000 OFF -WHITE 11 M SUPPLY 12X8 10X6 REGISTER - 33 340 OFF -WHITE 3 N SUPPLY 32X8 30X6 REGISTER - 33 945 OFF -WHITE 3 0 SUPPLY 26X16 24X14 REGISTER - 33 1600 OFF -WHITE 3 01 SUPPLY 16X12 14X10 REGISTER - 20 500 OFF -WHITE 9 P EXHAUST 8X8 6X6 EGGCRATE - 32 245 OFF -WHITE 4 Q EXHAUST 10X10 8X8 EGGCRATE - 34 400 OFF -WHITE 4 R EXHAUST 12X12 1OX10 EGGCRATE -- 34 600 OFF -WHITE 4 S EXHAUST 16X16 14X14 EGGCRATE - 34 1100 OFF -WHITE 4 Si EXHAUST 20X20 1 SX1$ EGGCRATE - 34 1500 OFF -WHITE 4 T EXH /RETURN 12X12 1OX10 GRILLE - 31 530 OFF -WHITE 6 U EXH /RETURN 20X14 18X12 GRILLE - 34 1200 OFF -WHITE 6 V EXH /RETURN 32X14 30X12 GRILLE - 36 1830 OFF -WHITE 6 W RETURN /TRAN 14X12 12X10 GRILLE - 35 1000 OFF -WHITE 5 X RETURN TRAN 32X8 30X6 GRILLE - 33 890 OFF -WHITE 6 Y SUPPLY 16X16 14X14 REGISTER - 32 975 OFF -WHITE 3 Z EXISTING GRILLE TO REMAIN AS IS, RE- BALANCE TO AIRFLOW INDICATED. NOTES 1. PERFORATED ALUMINUM CEILING DIFFUSER WITH ADJUSTABLE DISCHARGE PATTERN ON SUPPLY MODEL. PERFORATED FACE FLUSH WITH CEILING. 2. PERFORATED ALUMINUM CEILING RETURN DIFFUSER. PERFORATED FACE FLUSH WITH CEILING. 3. SINGLE DEFLECTION, STEEL SIDE WALL REGISTER, WITH BLADES SPACED 3/4" APART AND PARALLEL TO SHORT DIMENSIONS. 4. EGG -CRATE CEILING RETURN /EXHAUST GRILLE, 1/2" X 1/2" X 1/2" CORE, ALUMINUM CONSTRUCTION. 5. PERFORATED ALUMINUM SIDE WALL RETURN GRILLE. 6. 35' FIXED BLADE ALUMINUM GRILLE, WITH BLADES SPACED 3/4" APART AND PARALLEL TO LONG DIMENSION. 7. SURFACE MOUNTED, ALUMINUM DRUM LOUVER, WITH OPPOSED BLADE DAMPER. B. 35' FIXED BLADE STEEL GRILLE, WITH BLADES SPACED 3/4" APART AND PARALLEL TO LONG DIMENSION. 9. DOUBLE DEFLECTION, ALUMINUM SIDE WALL REGISTER, WITH FRONT BLADES HORIZONTAL AND SPACED 3/4" APART. MOUNT TOP OF REGISTER 25' -6" AFF. 10. 38'SINGLE DEFLECTION STEEL GRILLE, WITH BLADES SPACED 1/2" APART AND PARALLEL TO THE LONG DIMENSION AND /OR HORIZONTAL ORIENTATION. GRILLE TO BE HINGED FOR ACCESS TO LOUVER ACTUATORS. SIMILAR TO TITUS MODEL 33RFL. 11. 35`SINGLE DEFLECTION STEEL GRILLE, WITH BLADES SPACED 1/2- APART AND PARALLEL TO THE LONG DIMENSION AND /OR HORIZONTAL ORIENTATION. GRILLE TO BE HINGED FOR ACCESS TO LOUVER ACTUATORS. SIMILAR TO TITUS MODEL 355RF. .......... ... PLAN MARK j.Q Q Q MINIMUM AIR FLOW (CFM) INLET SIZE (INCHES) INLET S.P. (IN. WG.) ACTUATOR SIZE (AMPS) MAXIMUM N.C. LEVEL NOTES VAV 1 -1 BASKETBALL 3000 450 14 "0 0.4 1.0 35 1,2,3&4 O O O O O Z Z Z Z Z ., VAV BOX SCHEDULE PLAN MARK AREA SERVED BOX DATA MAXIMUM AIR FLOW (CFM) MINIMUM AIR FLOW (CFM) INLET SIZE (INCHES) INLET S.P. (IN. WG.) ACTUATOR SIZE (AMPS) MAXIMUM N.C. LEVEL NOTES VAV 1 -1 BASKETBALL 3000 450 14 "0 0.4 1.0 35 1,2,3&4 VAV 1 -2 BASKETBALL 3000 450 14 "0 0.4 1.0 35 1,2,3&4 VAV 1 -3 AEROBICS 2000 325 12 "4 0.3 1.0 35 1,2,3&4 VAV 1 -4 AEROBICS 2000 325 12 "0 0.3 1.0 35 1,2,3&4 VAV 5 -1 WOMEN'S LOCKER 2000 325 12 "0 0.3 1.0 35 1,2&3 VAV 5 -2 POOL 3000 450 14 990 0.4 1.0 35 1,2,3&4 VAV 5 -3 1ST LEVEL CIRCUIT TRAINING 3000 450 14"0 0.4 1.0 35 1,2&3 VAV 5 -4 POOL 3000 450 14 "0 0.4 1.0 35 1,2,3884 VAV 5 -5 MEN'S LOCKER 2000 325 12 "0 0.3 1.0 35 1,2&3 VAV 5 -6 1ST LEVEL CIRCUIT TRAINING 1050 175 9 "o 0.37 1.0 35 1,2&3 NOTES: 1. REFER TO ELECTRICAL DRAWING FOR ELECTRICAL INFORMATION. PROVIDE COMPLETE WITH DISCONNECT SWITCH AND TRANSFORMER, 2. PROVIDE COMPLETE WITH FIBER FREE LINER 3. BASIS OF DESIGN -- TITUS ESV 4. 1 OF 2 BOXES TO BE CONTROLLED IN TANDEM VIA SPACE MOUNTED THERMOSTAT. fJ I J i i i 7 � • i _i f� J SAITZ MICHELSON A R C H I T E C T S 3501 Griffin Road Ft. Lauderdale, FL 33312 (954) 266 -2700 Fx: (954) 266 -2701 sma @saltzmichelson.com 49 Thompson Company, Inc. 6220 South Orange Blossom Trail Suite 195 Orlando, FL 32809 TC1 #52316 407 - 438 -1860 phone 407 -438 -1172 fax AA- 0002897 Brian S. Hessinger, PE 52660 a r A z Project No.: 2003 -160 Drawn By: • • • w C3 Y V w YG•'i'4 1C G !i V u fi G w• i Checked By: • w BSH ! w U w .� .. V w ••!• r � V G V G p r r i Y• f G V r w • ! • ••Vw VrwlVi 12 -16 -03 PERMIT SET, • w • 02 -06 -04 DID SET • rt•r .i•r�. • • • o wowr •vw•• • ! w G • • .. V • r • w i wV•!• i REVISIONS: BUILDING DEPARTMENT COMMENTS 1 03-09 -04 LEGEND AND SCHEDULES MECHANICAL M 0. 1 x x \1