Loading...
04-04-011- �• I 3 �•' � I �i � 11 � / r \� / \ \ \\ \ \\ F_ \ f !j •O _ _ _ ` � f� \ \\ i \\ 11 // I �. • � A A.2 B C C.6 D E F G H H F.O.M. \� !� EXI5TING COMMON \\ �1 A XT I R WALKWAY E ER O L 000ON { { ( { { ( I // I f 1 / C// -jam: J 3. 00000 1 f I II �o \ Ew E04 L ,, EW� XD 4�/ \\ \ I / \ E03 t \ q 3/4� I I I I 1 "2' -4 1/2` I \\\ I\� \ I �G` ��`� ¢i \ ` �\� t\ I i r II 34G tIC7H NG OUNTER HA5.0 ✓ EXISTING COMMON II " ' -I 13 /I6" 3 -3 i 3 b' -b" � \ �� . � n1 3b 0 /Ib \ +�` , I EXTERIOR WALKWAY \ \ \ - I' t + 5PA E FOR ADA (' t �/j \\ � .;�i`\ - \ �`� \��.� ��I , �` EM �� � � � '� I I GOM' PLIANGE. 5EE ID, \`� �i p 115 ` , -1ST•, . I D / \ �` /. 1 I CLUB ENTR 2 \ I � 1 I \ ' { ( F13 STAIR \ 0WO / -/ I (rr R t I " \` -' SALES AREA , 1 1 � E02 2 I A4.1 I = I I I t ® 60 \\ \ 0 I�� 103 Ew . I � Ew " 41 ECEPT ION ST Q - 4 FI2� { 102 3 { , /// I / \ LONE A SIGN READING: I r , � \\ / A i I 2 OCCUPANCY BY MORE ` t \ Ew / THAN 1341 PERSON5 15 r - / 3 - - - - - \ I AS AS ` \ { �fl 0 � UNLAWFUL. _(INSERT B. O.'5 \ 42 // 2 NAME)- cp Imm r% Rnnr� �,, I .I BUILDING_OFFIGIAL I - wa i I _ ( I 2' -I 1/2, - �I X LU E�15TING PARKING GARAGE I C10 I I - I- I - - - - - - - - - -t r�- I t - - r--.. j7 r _ _ _ mm_ -- _ - �--`I� _- --� - -- .J- _ N I N II { I II N { I R I II { II ( II N I II II �I I n II II I N N N� II ii II II �I I N a N { Il { N I N N I A j .2 B II I n C C.6 II D E I F a IIG rJ v t As p Af dIU9 7 AS 1 t I- o / / �;\\ PROVIDE ONE, CE' - i I1ED 2A -1 10C FIRE AS AS M. , EXTINGUISHER ".' I / For each 3000 sq. ft. and with a mWmurn travel dist2nce to reach of 75% L[1'I 1 I ! 1$111 _ 111 _ , I _ _ , _ . I _ . exceed I r ' Top not to exceed 5' Bove the floor � \ .- II II II II �� H I I \N SECOND FLOOR PLAN SCALE: I/V = 1'_0" ii N / \\ \\ PLAN KEY NOTES: I, FURNISHING FOR REFERENCE ONLY. 2. PROVIDE UL RATING 4- A:60 -13:G, 10 LB. FIRE EXTINGUI5HER5 AS REQUIRED BY NFPA 10 AND LOCAL FIRE MARSHALL. EACH EXTINGUISHER 15 TO BE LOCATED WITHIN 15 FEET OF TRAVEL 015TANCE NO LE55 THAN ONE PER 3,000 S.F. (XX XXX / 3000 = 13 TOTAL FIRE EXTINGUISHERS REQUIRED) LOCATIONS REQUIRED BY FIRE MARSHALL TO BE REVIEWED BY ARCHITECT OR LA FITNESS REPRESENTATIVE PRIOR TO I145TALLATION. ESTABLISH ALL LOCATIONS PRIOR TO THE COMPLETION OF FRAMING TO BE VERIFIED BY AN LA FITNE55 REPRE5ENTATIVE. 3. CANOPY LINE OR SOFFIT ABOVE. 4. LOW WALL -5EE I /Al.i 5. FIRE DEPARTMENT LOCK BOX (MANUFAGTURER: KNOX COMPANY) b. 5AUNA FIN15HE5 OVER MR GYP. BOARD OVER STEEL STUD FRAMING. 5EE 5PEGIFIGATIDN. 1. NEW COLUMN. SEE 5TRUGTURAL DWGS. IA. EXISTING COLUMN TO REMAIN. b. EXISTING DOOR REMOVED AND REINSTALLED AT NEW FIN154 FLOOR ELEVATION. q. NOT USED. 10, POOL AND SPA UNDER SEPARATE PERMIT. SEE POOL t 5PA DRAWINGS FOR DETAILS AND CONSTRUCTION. COORDINATE MECHANICAL AND ELECTRICAL REOUIREMENT5 WITH POOL EQUIPMENT ROOM. 11. ARCHITECTURAL MILLWORK. 5EE INTERIOR DE516N DRAWINGS. 12. NEW 2HR BLOCK WALL. TH15 AREA TO MATCH EXISTING. 13. KICK BOXING BAGS, 5EE 5TRUGTURAL DRAWINGS. FOR SUPPORT SYSTEM, SEE ADDITIONAL INFO ON SHEET A1.3. 14. GATE BY MILLWORK SUB CONTRACTOR. SEE I.D. DRAWINGS. 15. POOL DEGK SLOT DRAIN. SEE POOL DRAWINGS. 16. EQUIPMENT, 5EE ENLARGED PLAN. 11, NOT 1,15ED. I& POOL DECK (5EE ID DRAWINGS) - PROVIDE 2% TO 4% PER FOOT SLOPE TO DRAIN. Iq. HIGH/LOW ELECTRIC WATER GOOLER5 5EE SHEET Aq,I 20, EXI5TING ROOF ACGE55 DOOR. 21. NEW ROOF PENETRATION5.5EE MECHANICAL. 22, MIRROR. SEE ID DRAHING5 FOR MORE INFO. 23. OMIT 24. MECHANICAL AIR SHAFT. NO FLOOR PENETRATION 25. NEW EXIT DOOR. 26. WARDROBE LO6KER5.5EE 5PEG5. AND I.D. DRAWINGS. BENCH PROVIDED AND INSTALLED BY G.G. 5EE SPECS. Z. LOGKER ROOM BENCHES - PROVIDED AND IN5TALLED BY G.G. 2b. SWIM -SUIT WATER EXTRACTOR. SEE 5PEC5. PLUMBING AND ELEG. 2q. VARY FURRING DEPTH AS REQUIRED TO ALIGN INTERIOR SURFACE OF WALL, 30. NOT USED. 31. GOLUMN FOR BASKETBALL BACKBOARD 5Y5TEM. COORDINATE W/ EQUIPMENT VENDOR AND SUBMIT TO ARCHITECT. 32. DOOR ON HOLD- OPEN, 5EE ELECTRICAL 33.5'X5" COLUMN TO SUPPORT KICK BOXING BAG. SEE STRUCTURAL DWGS. 34, EXISTING CURB. 35. FLOOR OPENING BETWEEN FIR5T AND 5EGON0 FLOOR. 36.51NGLE DRINKING FOUNTAIN TO BE ADA ACGE551BLE. 5EE SHEET Aq.1 31. EXISTING ELEVATOR 3b, GUARD RAIL -5EE SHEET A6.0 3q. ELECTRICAL FLOOR OUTLET -SEE ELEGTRIGAL DRAWINGS 40. EXI5TIN67 EXTERIOR STOREFRONT 41. LOCATION OF OCCUPANCY SIGN, FOR DETAILED INFORMATION 5EE GENERAL NOTE K4 BELOW. 42. EXISTING GUARDRAIL TO REMAIN. 43. ELECTRICAL PANEL, SEE ELEG. OWLS. 44. EXISTING 2HR. RATED MECHANICAL SHAFT. 45. NEW 2HR RATED MECHANICAL SHAFT. 46. INFILL WALL FRAME CON5TRUCTION. 5EE 5HEET A5.2. 5YM130LLEGEND TYPE: DE56RIPTION 0 5EGTION OR ELEVATION NUMBER 4( 5HE:E:T DRAWN ON ROOM ROOM NAME t NUMBER -Q1 WALL. TYPE NUMBER X01 DOOR NUMBER W3 WINDOW NUMBER PARTITION LEGEND NEW GWB ON METAL STUD WALL ( ONG. MASONRY WALL I HOUR RATED WALL (5EE GENERAL FLOOR PLAN NOTE #3) HOUR RATED WALL SEE GENERAL FLOOR PLAN NOTE #3) SOUND INSULATION PARTITION PROVIDE SOUND BATT INSULATION EXI5TING CONCRETE COLUMN �\ PARTITION LEGEND - ---- EXISTING ELEMENT TO REMAIN NEW ELEMENT GENERAL FLOOR PLAN NOTES: rJ J 7 L r SALTS MICHELSON A R C H I T E C T S 3501 Griffin Road Ft. Lauderdale, FL 33312 (954) 266 -2700 Fx: (954) 266 -2701 sma@saltzmichelson.com AA- 0002897 I. FOR REFLECTED GEILING PLAN SEE SHEET A3.4 2. FOR WALL TYPE INFORMATION SEE SHEET A5.D 3. ALL FIRE AND /OR SMOKE SEPARATION WALLS MUST BE IDENTIFIED ABOVE DECORATIVE CEILING AMC) IN CONGEALED 5PAGE5 BY STENCILED SIGN READING: "FIRE AND SMOKE BARRIER PROTEGT ALL OPENINGS'. 4. CONTRACTOR 5HALL P05T SfG -+.l INDICATING- MAX. CAPACITY IN ALL ROOMS RTH GREATER THAN 50 PEOPLE OCCUPANCY. THE SIGN SHALL READ A5 FOLLOW5: " OCCUPANCY BY MORE THAN XX(IN5ERT OCCUPANCY # FOR GIVEN AREA) PEOPLE 15 DANGEROUS AND UNLAWFUL. _(INSERT 8.0. NAME)_ BUILDING OFFICIAL. �- 5. MOUNT FIRE EXTINGUISHER GABINET5 9 42" A.F.F. TO GL OF FEC DOOR PULL. 5EE PLAN KEY NOTE #2 FOR FIRE EXTINGUISHER INFORMATION. 6• ALL PARTITION DIMENSIONS TO FACE OF STUD. UNLE55 NOTED OTHERWISE. I. FINISHED FLOOR ELEVATIONS AT 0'-0" AFF. ALL FLOORS TO BE LEVEL W/IN 1/2" AT ALL DOORWAYS. -/ b. 5EE DEMOLITION PLANS FOR INFO ON EXISTING ELEMENTS TO REMAIN, TO BE DEMOLISHED AND TO BE REMOVED AND REIN5TALLED. / M. PANIC, HARDWARE PROVIDED AT ALL EGRE55 DOOR5. 5EE SHEET A 6.0 FOR /- MORE INFO. 10. EXISTING FURRING TO BE DEMOLISHED AND REPLACED EXCEPT WHERE CONTRACTOR EVALUATES A5 UNEGGE55ARY. CONTRACTOR TO 5013MIT AREAS FOR APPROVAL BY ARC HITE( T AND OWNER. /i- APPRO VED By . C "" ��Me FIE DFRApalffrr PEIRIMIT WATER k-A • r z � Wr � V �u Vr 6YRn �arJ.0 w,� , u � Mw. J • 1 w Fh.+ �w !.! ir -'4U�W MvrrV4 Mark L. Saltz AR00070.1 ..r V rVU4u rWUr � u r'SV•� U V Project No.: 2003 -160 Drawn By: LV, CLB, KM Checked By: MA, DW v n CNI w 0 is n .1- cn a 4 i S m is 12 -16 -03 PERMIT SET 02 -06 -04 BED SET REVISIONS: FIRE DEPT. 1 -19 -04 ALA FITNESS 1- 2 1 •-22 -• 04 Q2-27 04 3 -zz - SECOND FLOOR PLAN A3.1 11 OF 33