Loading...
04-04-005C D E F G H I Al. I I 1 1 I I 1 I I I I I +511611 TOP OF EXIST. I I I PARAPET BEYOND I I I I I + TOP OF EXIST. —I= _n - — � . PARAPET + 45' -O" J. . =i -p - —=LFT F_ - TOP OF EXIST. _.— .— .— .— . —. —. —. i — .— ._- ... -. --- —._.I ...... ...... I _._I _._.� I — — — -� •—� •�� I i ROOF PECK I I I II ii I EX15TINCG ROOF (ROOF TOP UNITS TO REMAIN) SEE MECHI UNITS DRAWINGS " _ I _ _ . _.. -- I _ . _ _ _ _ - _ _ _ - TOP OF EXIST. ���111 I i t a — . — . — . — — — 1- I STRUCTURE 1 1 I 1 I I I I I _. -. VAGANT o I I 5 II VV I EXISTING I -MAX 4 2ND LEVEL 4 `• 14 n FL �. _. -.� ._. _. _. I _. _.� I__ �T i TOP OF EXIST. L .- l .I - STRUCTURE I- r . I I I i LJ LJ , III I I I d _ I I I I OP T OF EXIST . II I s III a I w I `i " I I j STRUCTURE I VAGANT +01 EXG I -MAX TOP OF SLAB 157 LEVEL GROUND LEVEL 4 „ I EX15T• GRADE I I I I I I I 1 1I 1 1 I I 1 EXI5TING GONG. 5LAB I EXC5TING GONG. RAMPI TO BE REMOVED TO BE REMOVED r2- DEMOLITION - BUILDING SECTION A133 SCALE: 1 /6" = 1' -0" 10 9 8 7 5 3 1 1 2 1 I. —' — .,._.- I / I ...... I _ ..-.,. ...._,. .«-... .I - ......- ......... - — - — - — .. ......� - ...,.... _ .......�.. - „,,_,_ - — - — - �— - T,,., •. _•...,,.. - �,.,- - - - — - + 62'011 L TOP of EXIST. j PARAPET BEYOND 1 ~ I I I I I I I I +511-611 Jill 1 j TOP OF EXIST. _ PARAPET + 50' -Q” ! I I I !EXISTING ROOF I I i TOP OF EXIST. TOP UNITS TO REMAIN) j n n ROOF DECK 5E6 MECHANICAL DRAWINGS - ► - �-- _:-_-1 . . _ �- I - . - ------ -------- _-- - - -- _- TOP pFEXIST. — — — — — — C- - -- - -- -.- :- :- '�C- : . RODE DECK MEGH MEGH! j I COMMON EXIT m I CHASE ' 2 VAGANT �—(; } -.� _ - CORRIDOR _ � � = I I I `-' � 1 � � I CHASE � � � ADJ. I ; (UNDISTURBED) I EXREM REMAIN I ; 4 I E 3RO LEVMEL I (4 ; EX EMl NTO _ �. i�L EXIT tCd _ +3I -a PARKING I.�j _._._. �. _. j �._. ; I �.— .— .— .— . —. —• —: —. — �._. -. -. . _ _ . _ _ _ _ _.— —�-_� — ._._..._.� . _ _ . _ ._._._. _.— .— .— . —. —._. . —. _: :r: _ :T?: _ . _ :� I STAIRS I (— TOP OF EXIST. (UNDISTURBED)- . _ I I II ' STRUCTURE EXISTING TO 1 _ I REMAIN IF II EXIT HI I� : I� I VAGANT STAI R5 I 1 I EXISTING I -MAX t�I I� i � I I EXISTING TO 4 2ND LEVEL �-{ 4� 4 REMAIN _._.J�I� =.�i I— •— ._._.— — _— _— _— _— —.�. —i i_. �.`-'. - _._._. _. I _. _..: -- ;LI..� .—. =Z1 —_ 1b. 0.1 _ _ TOP OF EXIST. T.,_....- .- . . :.. -- .,.,_...._- I �._._.- . -._._. :� I �. _, -.- :_ -. -.� I �._- .- ._._.__. _.__. -. —_� . -. -. r. :- ..- .- .�._.__. 5TRUGTURE Itt!-1 �IT T! T ....... ... IIi J_�111 HiH t o I III I III I a — ' ' - ' - 1 1 I VAC ANT I � I I , � � + o -6 1 I j I j I EXI5TIN6 I -MAX 4 4 1ST LEVEL 4 IbI TOP OF SLAB -- - _._._._._._._. i ._ ( -.__ :-_ :. :._ : I :_ ._: I :,�._.'._ �. .. _ ,. :---'� I -:_:_:- :- :_: -: -: -: I : -: .-- ;.---- :,._.:.�.:.�.._ .�._:�: h : - : - -: =: - . -- GROUND LEVEL -� - _ +/-0' _011 Et - -� L . EXIST. GRADE i DEMOLITION - BUILDING SECTION SCALE: I /b" = 11_0" r SPECIFIC DEMOLITION NOTES O EXI5TING PARTITION WALL5 TO BE REMOVED. EXI5TIN0 IMAX EQUIPMENT TO BE REMOVED BY IMAX. O EXISTING IMAX 5EATING TO BE REMOVED BY IMAX. O EXISTING FLOOR FINISHES TO BE REMOVED - PREPARE SLAB TO RECEIVE NEW FINISH PER LA FITNESS REQUIREMENTS. O EXISTING PLUMBING FIXTURES TO BE REMOVED, GAP AND GLO5E ALL WATER 5ERVICE I SANITARY LINES AND ID THEM FOR FUTURE USE. O EXI5TING TOILET PARTITIONS TO BE REMOVED. O EXISTING 5HELVING TO BE REMOVED. �a EXISTING RAMP TO BE REMOVED. OEXISTING AUDITORIUM SLAB TO BE REMOVED IN ITS ENTIRETY - 5EE 5TRIJGTURAL PLAN5. 0 EXI5TING COLUMN5 TO BE REMOVED - SEE STRUCTURAL PLANS. „ EXISTING EXTERIOR DOOR TO BE REMOVED, OPENING TO BE GL05ED OUT. t2 EXISTING STOREFRONT DOORS TO BE REMOVED 4 REPLACED WITH FIXED WINDOWS. 13 EX15TW BOX OFFICE WINDOWS TO BE REMOVED AND OPENING TO BE CLOSED OUT. 14 EXISTING INTERIOR DOOR UNITS TO BE REMOVED. 1 S EXI5TING INTERIOR WALL GOVERING AND METAL FRAMING. TO BE REMOVED. t EXISTING CMU BLOCK TO BE REMOVED AT THIS LOCATION. t 7 EXISTING RAISED 5LA13 TO BE REMOVED. t a EXISTING CEILING AND LIGHT FIXTURES TO BE REMOVED -SEE ELEC. DWGS. EXISTING 5TRUGTURAL COLUMNS TO REMAIN. 20 EXISTING STRUCTURAL COLUMN5 AND COVERING TO REMAIN. 21 EXISTING MONUMENTAL 5TAIR5 TO REMAIN. 22 EX5TIN6 ELECTRICAL ROOM TO REMAIN -SEE ELECTRICAL PLANS, 23 EXISTING ELEVATOR TO REMAIN. EXISTING MICA FIN15H TO BE MODIFIED. SEE ID DRAWINGS FOR MORE INFO. 24 EXISTING ELEVATOR MECHANICAL ROOM TO REMAIN. 2S EXISTING 5TOREFRONT SYSTEM TO REMAIN. 2� EXI5TING EGRE55 STAIR TO REMAIN. 27 EXISTING LAND56APE AREA TO REMAIN. 2a EXISTING SHEAR WALL TO REMAIN. 2"J EXISTING GMU WALL r0 REMAIN. 30 EXISTING STOREFRONT DOOR UNIT TO REMAIN. 3 t EXI5TING EXTERIOR DOOR UNIT TO REMAIN. 32 EXISTING DEMISING WALL TO BE REMOVED. 33 EXISTING GUARD RAIL TO BE REMOVED AND REPLACED. SEE DETAIL 4/A5.2 FOR MORE INFORMATION. 34 EXI5TING GONG. SLAB TO BE REMOVED. 35 EXISTING CONCRETE 5TEP5 TO BE REMOVED. 36 EX15TIN6 LANDSCAPE AREA TO BE REMOVED A5 REQ'D TO ACCOMMODATE NEW GONG. RAMP. 37 OMIT 1 3a EXISTING ROOF DRAIN TO BE REMOVED AND RELOCATED. SEE PLUMBING DWGS. FOR MORE INFO. 3� EXISTING DEMISING WALL TO REMAIN. 40 OMIT 1 4t EXISTING AIR HANDLER TO BE REMOVED AND RELOCATED AS REQ'D. 5EE MEGH. DWI FOR MORE INFO. 42 EXISTING EXTERIOR DOOR TO BE REMOVED AND RELOCATED. 43 OMIT 1 44 EXISTING TELEPHONE BOARD TO BE REMOVED 4 REPLACED. SEE ELEC. DWGS. FOR MORE INFO. 45 EXISTING SLAB t SOIL TO BE REMOVED TO ACCOMMODATE NEW FOOTINGS. 5EE STRL. OW65. FOR MORE INFO. 46 EXISTING ROCK BED TO BE EXCAVATED TO ACCOMMODATE NEW POOL AND POOL FOUNDATION. LEGEND EXI5TING ELEMENTS TO REMAIN UNDISTURBED EXISTING ELEMENTS TO BE REMOVED - SEE DEMOLITION NOTES AND ENLARGED PLANS yll� w • - • t • - 1 • • SALTZ MICHELSON A R C H I T E C T S 3501 Griffin Road Ft. Lauderdale, FL 33312 (954) 266 -2700 Fx: (954) 266 -2701 sma @saltzmichelson.com - 0002897 -V V i�:Y V 4 • u V u V • • 1 V � Y Y V fM1 Y V• V i u ♦ Y U U♦ i W U V Y U Y u • d i o • V Y u .. u• uuV•uY r U +P 4 •y• V ♦ � • ,v u u u • Y U � ♦ fir... ✓1 J � I v� j.� i �.( -r 4,.r � • Y i l :*ego, ii•G iY a Lao V • Y Mark L. Salt7, AR' 0007 1',41'* Y • • ease. i Y Y r Y i•i ♦• • Ei 0 0 FL a a m S 0 2 8 o-� Project No.: 2003 -160 Drawn By: LV, CLB, KM Checked By: MA, DW 12 -16 -03 PERMIT SET 02 -06 -04 BID SET REVISIONS: BLDG. DEPT_ 1 2 -27 -04 DEMOLITION SECTIONS A13 5 of 33