02-830-089• N x O M I L s i Q IL 1\ LO M -o • N O r` 0 3 0 W tn 00 N 0 3 LO 00 N v 3 w 4" SQUARE J -BOX 3 Iy10AWG 120VAC POWER PACK I 2 i14AWG I 214AWG DOOR CONTACTI L_ ADT I RELAY 6 #14AWG a 1AIN1 -HARN 4 #14AWG • KEY SWITCH KP1AN DOOR ALARM WIRING DIAGRAM 10 NOT TO SCALE MINI -HORN NORMAL CONDITION POWER ON KEY SWITCH OFF DOOR CLOSED R1 A 08 DUAL CONTACT DOOR IT�SITION R 2760 -9060 Kid TO ANNUNCIATOR I -`-- 24wC� KEY SWITCH L_ I KP1AN L7, 6 ADT (FROM4 2098 -9734) eDOOR ALARM DIAGRAM NOT TO SCALE NOTES FOR DOOR MONITOR OPERATION 1. WHEN DOOR OPENS . THE RELAY SHALL PICK TO ACTIVATE THE MINI -HORN AND LATCH ACROSS THE DOOR POSITION SNATCH. 2. KEYSWITCH SHALL BYPASS DOOR POSITION SWITCH FOR AUTHORIZED ACCESS. 3. KEYSWITCH SHALL RESET SYSTEM BY DROPPING POWER TO RELAY IN THE EVENT OF UNAUTHORIZED DOOR ACCESS. 4. SECOND CONTACT OF DOOR POSITION SWITCH TO LIGHT LIGHTS ON OFFICE ANNUNCIATOR. 5. CALL STEVE SCHIAVELLO AT ADT: 1- 806 -7074 FOR PRICING AND QUESTIONS FIRE ALARM LAYOUT SCALE: 3/32"=l'-O" NOTE: ALL WORK SHALL COMPLY WITH APPLICABLE CITY, COUNTY, STATE AND NFPA CODES. ITEM DESCRIPTION STANDBY CURRENT PER UNIT (AMPS) T_ O W QTY. REQUIRED TOTAL STANDBY CURRENT PER ITEM (AMPS) ALARM CURRENT PRE UNIT (AMPS) REQUIRED QTY. STANDBY TOTAL ALARM CURRENT (AMPS) A FACP 0.12 X 1 = 0.12 1.5 X 1 = 1.5 B SMOKE DET 0.0001 X 3 - 0.0003 0.0213 X 3 (AMP - HOURS) 0.064 2.94 (AMPS) 0.316 (HOURS) 24 X 0.1223 = 2.94 0.0833 X 1 3.793 D HORN STROBES - X 2 - 0.078 X 2 = 0.156 E STROBES - X 26 = - 0.078 X 26 2.03 1� W V A 0 b O I TT__ b TOTAL SYSTEM STANDBY CURRENT (AMPS) 0.1223 TOTAL SYSTEM ALARM CURRENT (AMPS) 3,793 REQUIRED OPERATING TIME OF SECONDARY POWER SOURCE FROM NFPA 72.1- 5.2.5. STANDBY: 24 HOURS ALARM 5 MINUTES X 1/60 = 0.0833 HOURS REQUIRED l TOTAL SYSTEM T_ O W REQUIRED REQUIRED OPTIONAL TOTAL SYSTEM REQUIRED REQUIRED STANDBY ALARM STANDBY REQUIRED STANDBY ALARM 1. 122 ALARM CAPACITY ALARM TIME CURRENT rn CAPACITY TIME CAPACITY CURRENT J CAPACITY (HOURS) (AMP - HOURS) (AMPS) w I (AMP - HOURS) (HOURS) 2.94 (AMPS) 0.316 (HOURS) 24 X 0.1223 = 2.94 0.0833 X 1 3.793 = 0.316 REQUIRED l REQUIRED T_ O W TOTAL 04 OPTIONAL W ziC REQUIRED STANDBY ALARM X REQUIRED M FACTOR OF 1. 122 BATTERY CAPACITY LL» W CAPACITY CAPACITY rn SAFETY z CAPACITY (AMP - HOURS) J (AMP - HOURS) �► o . Irk O (AMP - HOURS) o w I �IL ; V4 � 'W M (AMP - HOURS) 2.94 + 0.316 = 0.326 X 1.2 = 3.91 .._ .R.... ............................. �.... »... LEGEND © PULL STATION. SIMPLEX NO. 2099 -975 DUCT SMOKE DETECTOR. SIMPLEX NO. 4098 -9706 FS WATERFLOW SWITCH (FURNISHED BY SPRINKLER CONTRACTOR) O SMOKE DETECTOR. SIMPLEX CAT. NO.4098- 9784/9701 <a> HEAT DETECTOR. SIMPLEX CAT. NO. 4098 - 9784/9732 TS I TAMPER SWITCH (FURNISHED BY SPRINKLER CONTRACTOR) PROVIDE SUPERVISED IAM CILIDI rV PAT KIn F)Ion_0110A nom, AUDIO /VISUAL UNIT WALL MOUNTED. SIMPLEX NO. 4903 -9405 L� I� 2901 SERIES HORN. MOUNT 6'-8" A.F.F. OR PENDANT MOUNTING L>O WP WEATHERPROOF HORN WITH WEATHERPROOF BOX. SIMPLEX NO. 2975 -9009 S�Q VISUAL UNIT CEILING MOUNTED. OR PENDANT MOUNTED SIMPLEX NO. 4904 -9327 ®B EXIT SIGNS CONNECTED TO EMERGENCY CKT. THRU STANDBY GENERATOR. SEE LIGHTING PLAN ® NIGH LIGHT CONNECTED TO EMERGENCY CKT. NL THRU STANDBY GENERATOR. ® SEE LIGHTING PLAN F_HFRj FIRE SUPPRESSION RELAY NOTE: 1. AT LEAST ONE HALF OF THE REQUIRED EXITS SHALL BE LOCATED SO AS TO BE REACHED WITHOUT PASSING THROUGH CHECK OUT STANDS AND SHALL NOT BE W� �'j`A FIBAj_A',zZjM OBSTUCTED. MR TIMS Ul�AVAI \T,Ot 2. ALL FIRE EXTINGUISHERS TO HAVE1�'Q IISTALi.A. ril ON IDENTIFICATION SIGNS. _ �� Fire A1nrm contractor's worl:i.. plans shall be st muted for permit approval to Miami - 'Da&,County Fire Department. 4.AppMlVpulf o Buildin P lkate oa P�r l5 mo i u r- --I 3 0 EXISTING MEZZANINE / MACHINE ROOM SCALE 3/32' V -0- 41 14 FPL - 1/2- C. OUTSIDE OUTSIDE if F � - 4114 FPL - 1/2" C. ZONE 5 ZONE 4 TS 2416 TWISTED S IELDED FPL CABLE 1/2- RTU -1 RTU -2 ZONE 2 ZONE 1 TOTAL QUANTITY 3 RESTROOM TOTAL QUANTITY 7 !/16 TWISTED SHIELDED FPL CABLE 1/2- FIRE ELECT. MACH. HEF -1 HEF -2 HEF PNL ROOM ROOM EXHAUST HOODS TOTAL QUANTITY 26 TS TS 1 2 ZONE 34 ZONE s SIMPLEX ADDRESSABLE PANEL FOR BACKFLOW FIRE CAT. NO.4020 -8001 PREVENTOR. SEE ALARM ANNUN. --- SIMPLEX REMOTE ANNUNCIATOR SHEET WDE -1. CONTROL PANEL PANEL PANEL CAT. NO.4603 -9101 (SEE NOTE #10,11,13,20) 1 #6 C L2fl6 TWISTED SHIELDED FPL CABLE 1/2' EM- (120 VAC) 3/4- TO TELEPHONE BACKBOARD (PROVIDE TWO DEDICATED UNES SEE NOTE 115) 3/4- TO SECURITY SYSTEM PANEL FIRE ALARM RISER DIAGRAM NOT TO SCALE FIRE ALARM SYSTEM NOTES: 1. VERIFY LOCATION OF ALL DEVICES AND PANEL WITH FIRE MARSHALL AND WINN -DIXIE REPRESENTATIVE PRIOR TO ROUGH -IN. 2. PROVIDE & INSTALL ALL "FIRE MARSHALL APPROVED" SIGNAL TRANSMISSION EQUIP. FOR MUNICIPAL TIE -IN. COORDINATE W /FIRE DEPT. 3. TROUBLE AND ALARM INITIATIONS TO TRANSMIT SEPARATE AND DISTINCT SIGNALS TO MONITORING STATION. 4. INCOMING "FIRE" ALARM INITIATIONS SHALL OVERRIDE "TROUBLE" INITIATIONS. 5. SEPARATE "TROUBLE" AND "ALARM" SIGNALS SHALL BE ANNUNCIATED AT F.A. CONTROL PANEL. 6. SUBMIT SHOP DRAWINGS TO FIRE MARSHALL FOR APPROVAL PRIOR TO ROUGH -IN. PRIOR TO ROUGH - IN 7. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA 72, ADA REQUIREMENT, AND ALL STATE & LOCAL CODES. 8. ZONE 7 TO 13 SHALL CONNECT TO N.O. (NORMALLY OPEN) CONTACTS PROVIDED WITH EXHAUST HOOD AUTOMATIC EXTINGUISHING SYSTEM. PROVIDE SUPERVISED MODULE SIMPLEX CAT.NO.2190 -9172A FOR EACH ONE 9. OMIT 10. THE FIRE ALARM PANEL AND THE ANNUNCIATOR PANEL SHALL PROVIDE VISUAL LOCATION OF DEVICE ACTIVATED BY FLOOR, DEVICE TYPE, LOCATION ov o1nCCT1oU, nnoUlpCp uA-m .k Tnouot_C CIO ►I.A.L (LIOUAL. J. A.uDID1.C) AND THE SYSTEM SHALL BE SUPERVISED. 11. THE FIRE ALARM CONTROL PANEL, ALARM ANNUNCIATORS AND MANUAL COMMUNICATIONS CAPABILITY, SHALL BE INSTALLED AT A CONVENIENT LOCATION ACCEPTABLE TO THE A.H.J. VERIFY W/ FIRE MARSHALL PRIOR TO ROUGH -IN. 12. ALL ELECTRICAL PANELS AND EQUIPMENT SHALL BE SHIELDED FROM WATER INSIDE THE MACHINE ROOM) 13. THE ANNUNCIATION PANEL SHALL BE PERMANENTLY LABELED (NO TAPE OR STECK -ON LABELS ARE ACCEPTABLE UNLESS PROTECTED) 14. NO CONTROL FUNCTIONS SUCH AS SILENCE 0 RESET SWITCHES SHALL BE INSTALLED ON THE ANNUNCIATION PANEL 15. THE FIRE ALARM AND FIRE SPRINKLER SYSTEM SHALL BE CONNECTED TO A CENTRAL, MONITORING COMPANY AND PROVIDED WITH TWO DEDICATED PHONE LINES) 16. FIRE ALARM STROBE LIGHTS SHALL MEET ADA 17. ALARM PULL STATIONS SHALL BE MOUNTED AT A HEIGHT OF 48" TO THE HANDLE. (AS PER ANSI- A117.1) 18. THE GENERAL EVACUATION ALARM SIGNAL SHALL OPERATE THROUGHOUT THE ENTIRE BUILDING AND THE SIGNAL SHALL BE OF THE NEW STANDARD EVACUATION SIGNAL (101 -A -7 -6.3.3 19. FIRE ALARM SIGNAL SHALL BE EFFECTIVE HEARD ABOVE THE AVERAGE AMBIENT SOUND LEVEL OCURRED UNDER NORMAL CONDITIONS OF OCCUPANCY (101 -7- 6.3.6) 20. EACH HOOD EXTINGUISHING SYSTEM SHALL BE CONNECTED TO THE FIRE ALARM AND EACH SYSTEM SHALL BE ANNUNCIATED ON THYE FACP AND THE REMOTE ANNUNCIATOR PANEL 21 FIRE ALARM AND BURGLAR ALARMS SHALL BE INSTALLED ON SEPARATE PANELS. 22. DUCT DETECTORS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR AND INSTALLED BY MECHANICAL CONTRACTOR. r ` a� N r� Ld V1 � i V) U O n 0 wow.o �O HQ� In • In u 0 UNO LLI n � Q0 • O ZJ O U 0) QI r_ Q La'r) F- ,SEAL z ac r r i el Q J ENGINEERS l o T_ O W N 04 W ziC , -•�- -M n W %n - X acnMo M Q 1. 122 O v w L_4 z Z LL» W = Q a^ rn E z rn =E J .2s m �► o . Irk O W Z BM o REVISIONS: W l o T_ O W LLJ � V) O J W X Q � U) Q z Z t0 cc 0000 O E gI L. W O �► o . Irk O �. ` w I �IL ; V4 � 'W M "'o A r- z Li Vj co o W0) f `c x tij w " ; O ~ ` o E a� ®O V A 1� W V A 0 b O b W l o T_ O W LLJ � V) O J W X Q � U) Q z Z t0 = 0000 O DRAWING TITLE F I R F ALARM P LAN TE: ..... E 17, 2002 -AWN BY: 'CHECKED BY: QIMSION tom' MIAMI LOCATION NO. 285 W.D. GUIDE PLAN CPR: CT N0. #0704 DRAWING NO. E -103 of SHEET NO. OF