Loading...
02-830-070N x 0 M I W s U L Q CL r ri O N 0 N O 0 rn 3 -a 0 to I N Lo 00 N 0 3 v 3 w DISCONNECT SWITCH: FACTORY (TYPICAL) MOTOR: INTERNALLY PROTECTED (TYPICAL) REMOVABLE MOTOR COVER: ALUMINUM — 4 HINGED FAN Lu — L JLI BASE & HOLD - - -� z w OPEN DEVICE I FAN I o - -- O0 - -- � w �o �o 4 FACTORY U B• 10' -0" MIN ELECTRICAL CONTROL PACKAGE: WITH CONTACTORS AND TERMINAL BLOCKS FOR POWER & CONTROL (120/1 VOLT), FACTORY INSTALLED. ALARM SHALL SHUT DOWN MAKE —UP FAN AND RUN EXHAUST FAN CONTINUOUSLY. UL LISTED REMOVABLE TOP J� /� _ GALVANIZED SUPPLY FAN SECTION FAN I EQUIPMENT RAIL - -� C R `— MAKE —UP AIR DUCT: VENTILATED, v v vt METAL WITH 2" WRAP SEE DETAIL INSULATION EXHAUST AIR DUCT: TRANSITION FROM FAN SIZE 16 GAUGE, WELDED TO DUCT SIZE: SEE PLAN LIQUIDTIGHT FOR SIZE ELECTRICAL SERVICE ENTRY: UP INSIDE CURB, SINGLE POINT CONNECTION NOTE: PROVIDE A SINGLE WALL SWITCH, FOR THE MAKE —UP AIR FAN AND THE EXHAUST AIR FAN TO RUN SIMULTANEOUSLY. LOCATE ADJACENT TO THE LIGHT SWITCH. HOOD #1 FAN PACKAGE DETAIL NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS. HOOD SPECS DESIGNATION HFP -1 LOCATION DELI HOOD SERVED HOOD #1 CAPTIVEAIRE MODEL RTP —B WEIGHT — LBS 625 MAKE —UP AIR SECTION 1160 BLOWER DIAMETER — IN 12 CFM / SP 2650/0.35 MOTOR HORSEPOWER 1.00 MOTOR VOLTAGE 208 EXHAUST AIR FAN STAINLESS WHEEL DIAMETER — IN 18 CFM / SP 3765/1.0 MOTOR HORSEPOWER 1.5 MOTOR VOLTAGE /PHASE 208/3 PACKAGE VOLTS /FLA 208/29.8 APPROVED MANUFACTURERS OF THE EXHAUST AND SUPPLY FANS ARE AS FOLLOWS: STANLEY INDUSTRIAL CORP. 904 - 731 -4711 CARNES COMPANY 608 - 845 -6411 PENN VENTILATOR COMPANY 215- 464 -8900 LOREN COOK COMPANY 417 - 869 -6474 GREENHECK 715- 359 -6171 ACME 918- 682 -7791 * FANS SHALL BE COMPLETE WITH HIGED TOP WITH HOLD OPEN RETAINERS AND WITH GREASE CUPS. FANS SHALL BE U.L. LISTED FOR GREASE EXTRACTION APPLICATION GAUGE METAL STRAP. CONDENSER SECTION STEEL FACTORY FABRICATED 18" HIGH ROOF CURB ANCHORED TO STEEL JOIST EXHAUST AIR DUCT: 16 GAUGE, WELDED LIQUIDTIGHT, MINIMUM 1500 FPM VELOCITY. HANGER RODS: TO STRUCTURE ABOVE, 1/2" JUNCTION BOX GALVANIZED FOR CONTROLS TRUNK LINE OR LIGHTS z w > a FILTERS: WASHABLE ALUMINUM ROOF WALL OUTSIDE AIR INTAKE W/ DAMPER & INSECT SCREEN NEW A/C UNIT BOLTED TO ROOF CURB WITH 22 �SEL TAPPING SCREWS 12567C C EXISTING ROOF INSULATION -7 2 -SELF TAPPING SCREWS L,(�l.q►y �-- EXISTING EQUIPMENT CURB #22, 1.5" (EACH SIDE) UPPLY AIR DUCT SMOKE DET. �!b)10/\ASUAL D. ONNECTED TO LOCAL ALARM W/ INDICATOR LIGHT N.T.S. MOUNTED ON STEEL JOIST EXHAUST AIR MAKE —UP PLENUM AIR PLENUM CEILING, 10' -0" L 1. FILL —IN PANEL, FROM TOP OF HOOD THRU CEILING, ALL EXPOSED SIDES THERMAL INSULATION: 1", /FOIL FACED WITH FOIL AT AIRSTREAM SIDE. PERFORATED PLATE: FOR UNIFORM AIRFLOW AT THE FRONT / OF THE HOOD MAKE —UP AIR DUCT: 22 GAUGE, _ WITH 2" WRAP INSULATION FIRE DAMPER: UL APPROVED, FACTORY INSTALLED LIGHTS: UL APPROVED. FILTERS: UL — PROVIDE WALL SWITCH ADJACENT CLASSIFIED, ALUMINUM TO FAN SWITCH EXTRACTOR TYPE MAKE —UP AIR SLOT: LOW (NOT MESH) VELOCITY, FOR INDUCTION OF AIR AT FRONT OF HOOD GREASE TROUGH GREASE CUP 6'6" 3" AIR SPACE, VENTED AFF REAR AND LEFT HAND SIDF OF HOOD HOOD 1 GREASE LADEN EXHAUST HOOD DETAILS NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS. HOOD SCHEDULE DESIGNATION HOOD #1 LOCATION DELI — BAKERY EQUIPMENT SERVED CONVECTION OVEN, WITH MANUF. SHOP DWGS. CHICKEN FRYER CAPTIVEAIRE MODEL NO. 5424 —R WEIGHT — LBS 1160 DIMENSIONS — LENGTH 12' -0" WIDTH 4' -6" HEIGHT 2' -0" MATERIAL — EXTERIOR STAINLESS (304) INTERIOR STAINLESS TOP GALV. /ALUMINIZED EXHAUST AIR CFM 3765 OPENING 12x15 (2) EACH VELOCITY 1506 MAKE —UP AIR CFM 2650 OPENINGS) 12x24 (2) EACH NOTES: 1. HOOD SHALL BE BUILT IN ACCORDANCE WITH NFPA —, 961 AND HAVE THE APPROVALS OF SBCC, BOCA, NSF, AND UNDERWRITERS LABRATORIES. 2. PROVIDE A FIRE EXTINGUISHING SYSTEM, INSTALLED BY A STATE LICENSED FIRE PROTECTION CONTRACTOR, BOTTLE SHALL BE INSTALLED BELOW THE CEILING FOR SERVICE, WITH ALL PIPING ABOVE THE CEILING. INTERLOCK FANS PER CODE. 3. THE GENERAL CONTRACTOR SHALL PROVIDE A ONE —HOUR CHASE AROUND THE EXHAUST DUCT. Q 4. PROVIDE "FILL —IN PANELS" TO EXTEND FROM THE TOP OF THE HOOD THROUGH THE 10'0" CEILING: PANEL CONSTRUCTION SHALL MATCH THE HOOD CONSTRUCTION. 5. APPROVED MANUFACTURERS OF THE EXHAUST HOODS ARE AS FOLLOWS; AEROLATOR SYSTEMS, INC. 704 -821 -7605 CAPTIVE —AIRE SYSTEMS, INC. 919 - 872 -1902 SUN —AIR HOODS 205 - 252 -5451 LOAD —KING, INC. 904 - 354 -8882 GREASEMASTER, iNC. 704 - 821 -9211 LARKIN INDUSTRIES 205 - 591 -5413 HFP -1 20X1 15X1 /—NON RATED CEILING. PANEL- 21-0" CAPTURE AREA. — ROOF DECK r• -15X12 HOOD #1 12' -0" CAPTURE AREA. 6" MIN. I io COOKING EQUIP. REFER TO DWG. M FOR ADDITIONAL DETAILS. 6" 22 GAUGE STAINLESS STEEL PLATE OR TILES 6" MIN. DELI BAKERY HOOD ELEVATION NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS. HFP -1 REFER TO DWG M -3 FOR HOOD PACKAGE DETAIL GREASE COLLECTOR. x N FIN. ROOF.�� HINGED FAN ol BASE 18X20 12X15 5/8" DRYWALL ON METAL STUDS (NON— COMBUSTIBLE) HOOD #1 (REFER TO DWG M -3 10' -0" MIN. KSF -1 �- ROOF DECK. NON RATED —12X24 CEILING. VD FILL —IN PANEL. FD UL LISTED FIRE DAMPER AT HOOD INLET. FOR DETAILS). I 2' -0" CAPTURE AREA. 4'-0" CAPTURE AREA. — UL CLASSIFIED HOOD, SEE SCHEDULE. 4' -6" 22 GA. STAINLESS I STEEL PLATE. co COOKING EQUIP. _______ --- -__ I I r— FINISHED FLOOR. DELI - BAKERY HOOD SECTION NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS. NON RATED CEILING. FILL -IN PANEL 2' -0., CAPTURE AREA. — HFP -3 r__J oo x 00 ROOF DECK HOOD 2 3' -0" CAPTURE AREA. 6" MIN. cD STEAMER REFER TO DWG. M -3 FOR ADDITIONAL DETAILS. 6" 22 GAUGE STAINLESS STEEL PLATE OR TILES 6" MIN. SEAFOOD HOOD ELEVATION NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS. HFP -3 REFER TO DWG M -3 FOR HOOD PACKAGE DETAIL GREASE COLLECTOR. �- N FIN. ROOF.-----\ HINGED FAN BASE 8x8 5/8" DRYWALL ON METAL STUDS (NON— COMBUSTIBLE) HOOD #3 ' (REFER TO DWG M -3 FOR DETAILS). 4' -0" CAPTURE AREA. 4' -0" io 22 GA. STAINLESS I STEEL PLATE. _--- - ---------- � I COOKING EQUIP. ;--- ----- -----; ROOF DECK. NON RATED CEILING. FILL —IN PANEL. 2' -0" CAPTURE AREA. — UL CLASSIFIED HOOD, SEE SCHEDULE. FINISHED FLOOR. SEAFOOD HOOD SECTION NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS. acN N rr^^ W vl � t\ � u (o O t\ to 0 I- I,r � ^O w O j( 00 �g o L ' I I-L M H Q ao Ln No w U Y Ln • O Z� U 0)- QQI r_ :2 Q � 1— SEAL �r z ell ti: _ ENGINEERS C3-: � S� 12 o Lj z a A •p x W W 4 _ M = i•E ! W� REVISIONS: a .,C , °I,00 t'' CL (� O wco t%) 4 A� w U) cc J o " (D E Q ® U A A 0 PROJECT NO. WD #0704 DRAWING NO. M-5* OF — SHEET NO. OF — FF(nwy- p � W Fh O � W X Q � � U) Z ILO � O Lo co PROJECT NO. WD #0704 DRAWING NO. M-5* OF — SHEET NO. OF —