02-830-070N
x
0
M
I
W
s
U
L
Q
CL
r
ri
O
N
0
N
O
0
rn
3
-a
0
to
I
N
Lo
00
N
0
3
v
3
w
DISCONNECT
SWITCH: FACTORY
(TYPICAL)
MOTOR: INTERNALLY
PROTECTED (TYPICAL)
REMOVABLE MOTOR
COVER: ALUMINUM —
4
HINGED FAN Lu — L JLI
BASE & HOLD - - -�
z w OPEN DEVICE I FAN I
o - --
O0 - --
� w
�o
�o
4
FACTORY U B•
10' -0" MIN
ELECTRICAL CONTROL PACKAGE:
WITH CONTACTORS AND TERMINAL
BLOCKS FOR POWER & CONTROL
(120/1 VOLT), FACTORY INSTALLED.
ALARM SHALL SHUT DOWN MAKE —UP
FAN AND RUN EXHAUST FAN
CONTINUOUSLY. UL LISTED
REMOVABLE TOP
J� /� _ GALVANIZED SUPPLY
FAN SECTION
FAN
I
EQUIPMENT
RAIL - -�
C R `— MAKE —UP AIR DUCT:
VENTILATED, v v vt METAL WITH 2" WRAP
SEE DETAIL INSULATION
EXHAUST AIR DUCT: TRANSITION FROM FAN SIZE
16 GAUGE, WELDED TO DUCT SIZE: SEE PLAN
LIQUIDTIGHT FOR SIZE
ELECTRICAL SERVICE ENTRY:
UP INSIDE CURB, SINGLE
POINT CONNECTION
NOTE:
PROVIDE A SINGLE WALL SWITCH, FOR
THE MAKE —UP AIR FAN AND THE EXHAUST
AIR FAN TO RUN SIMULTANEOUSLY.
LOCATE ADJACENT TO THE LIGHT SWITCH.
HOOD #1 FAN PACKAGE DETAIL
NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS.
HOOD SPECS
DESIGNATION
HFP -1
LOCATION
DELI
HOOD SERVED
HOOD #1
CAPTIVEAIRE MODEL
RTP —B
WEIGHT — LBS
625
MAKE —UP AIR SECTION
1160
BLOWER DIAMETER — IN
12
CFM / SP
2650/0.35
MOTOR HORSEPOWER
1.00
MOTOR VOLTAGE
208
EXHAUST AIR FAN
STAINLESS
WHEEL DIAMETER — IN
18
CFM / SP
3765/1.0
MOTOR HORSEPOWER
1.5
MOTOR VOLTAGE /PHASE
208/3
PACKAGE VOLTS /FLA
208/29.8
APPROVED MANUFACTURERS OF THE EXHAUST AND SUPPLY FANS ARE AS FOLLOWS:
STANLEY INDUSTRIAL CORP. 904 - 731 -4711
CARNES COMPANY 608 - 845 -6411
PENN VENTILATOR COMPANY 215- 464 -8900
LOREN COOK COMPANY 417 - 869 -6474
GREENHECK 715- 359 -6171
ACME 918- 682 -7791
* FANS SHALL BE COMPLETE WITH HIGED TOP WITH HOLD
OPEN RETAINERS AND WITH GREASE CUPS. FANS SHALL
BE U.L. LISTED FOR GREASE EXTRACTION APPLICATION
GAUGE
METAL STRAP.
CONDENSER SECTION
STEEL FACTORY FABRICATED
18" HIGH ROOF CURB
ANCHORED TO STEEL JOIST
EXHAUST AIR DUCT: 16 GAUGE,
WELDED LIQUIDTIGHT, MINIMUM
1500 FPM VELOCITY.
HANGER RODS: TO STRUCTURE
ABOVE, 1/2"
JUNCTION BOX
GALVANIZED FOR CONTROLS
TRUNK LINE OR LIGHTS
z
w
>
a
FILTERS:
WASHABLE
ALUMINUM
ROOF
WALL
OUTSIDE AIR
INTAKE W/ DAMPER
& INSECT SCREEN
NEW A/C UNIT BOLTED
TO ROOF CURB WITH
22 �SEL TAPPING SCREWS
12567C
C
EXISTING ROOF
INSULATION -7
2 -SELF TAPPING SCREWS L,(�l.q►y �-- EXISTING EQUIPMENT CURB
#22, 1.5" (EACH SIDE)
UPPLY AIR DUCT SMOKE DET.
�!b)10/\ASUAL D. ONNECTED TO LOCAL
ALARM W/
INDICATOR LIGHT
N.T.S.
MOUNTED ON STEEL JOIST
EXHAUST AIR MAKE —UP
PLENUM AIR PLENUM
CEILING, 10' -0"
L 1.
FILL —IN PANEL, FROM TOP OF
HOOD THRU CEILING, ALL
EXPOSED SIDES
THERMAL INSULATION: 1",
/FOIL FACED WITH FOIL AT
AIRSTREAM SIDE.
PERFORATED PLATE: FOR
UNIFORM AIRFLOW AT THE FRONT
/ OF THE HOOD
MAKE —UP AIR DUCT: 22 GAUGE,
_ WITH 2" WRAP INSULATION
FIRE DAMPER: UL APPROVED,
FACTORY INSTALLED
LIGHTS: UL APPROVED.
FILTERS: UL — PROVIDE WALL SWITCH ADJACENT
CLASSIFIED, ALUMINUM TO FAN SWITCH
EXTRACTOR TYPE MAKE —UP AIR SLOT: LOW
(NOT MESH)
VELOCITY, FOR INDUCTION OF
AIR AT FRONT OF HOOD
GREASE TROUGH
GREASE CUP 6'6"
3" AIR SPACE, VENTED AFF
REAR AND LEFT HAND
SIDF OF HOOD
HOOD 1
GREASE LADEN EXHAUST HOOD DETAILS
NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS.
HOOD SCHEDULE
DESIGNATION
HOOD #1
LOCATION
DELI — BAKERY
EQUIPMENT SERVED
CONVECTION OVEN,
WITH MANUF. SHOP DWGS.
CHICKEN FRYER
CAPTIVEAIRE MODEL NO.
5424 —R
WEIGHT — LBS
1160
DIMENSIONS — LENGTH
12' -0"
WIDTH
4' -6"
HEIGHT
2' -0"
MATERIAL — EXTERIOR
STAINLESS (304)
INTERIOR
STAINLESS
TOP
GALV. /ALUMINIZED
EXHAUST AIR CFM
3765
OPENING
12x15 (2) EACH
VELOCITY
1506
MAKE —UP AIR CFM
2650
OPENINGS)
12x24 (2) EACH
NOTES:
1. HOOD SHALL BE BUILT IN ACCORDANCE
WITH NFPA —, 961 AND HAVE THE APPROVALS
OF SBCC, BOCA, NSF, AND UNDERWRITERS LABRATORIES.
2. PROVIDE A FIRE EXTINGUISHING SYSTEM,
INSTALLED BY A STATE LICENSED FIRE
PROTECTION CONTRACTOR, BOTTLE SHALL BE INSTALLED BELOW THE CEILING FOR
SERVICE, WITH ALL PIPING ABOVE THE
CEILING. INTERLOCK FANS PER CODE.
3. THE GENERAL CONTRACTOR SHALL PROVIDE A ONE —HOUR CHASE AROUND THE EXHAUST
DUCT.
Q
4. PROVIDE "FILL —IN PANELS" TO EXTEND
FROM THE TOP OF THE HOOD THROUGH THE
10'0" CEILING: PANEL CONSTRUCTION
SHALL MATCH THE HOOD CONSTRUCTION.
5. APPROVED MANUFACTURERS OF THE EXHAUST HOODS ARE AS FOLLOWS;
AEROLATOR SYSTEMS, INC.
704 -821 -7605
CAPTIVE —AIRE SYSTEMS, INC.
919 - 872 -1902
SUN —AIR HOODS
205 - 252 -5451
LOAD —KING, INC.
904 - 354 -8882
GREASEMASTER, iNC.
704 - 821 -9211
LARKIN INDUSTRIES
205 - 591 -5413
HFP -1
20X1
15X1
/—NON RATED
CEILING.
PANEL-
21-0"
CAPTURE
AREA. —
ROOF DECK
r• -15X12
HOOD #1
12' -0" CAPTURE AREA.
6" MIN.
I
io
COOKING EQUIP.
REFER TO DWG. M
FOR ADDITIONAL
DETAILS.
6"
22 GAUGE STAINLESS
STEEL PLATE OR TILES
6" MIN.
DELI BAKERY HOOD ELEVATION
NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS.
HFP -1
REFER TO DWG M -3 FOR
HOOD PACKAGE DETAIL
GREASE
COLLECTOR.
x
N
FIN. ROOF.��
HINGED FAN
ol
BASE
18X20
12X15
5/8" DRYWALL ON
METAL STUDS
(NON— COMBUSTIBLE)
HOOD #1
(REFER TO DWG M -3
10' -0" MIN.
KSF -1
�- ROOF DECK.
NON RATED
—12X24 CEILING.
VD FILL —IN PANEL.
FD UL LISTED FIRE DAMPER
AT HOOD INLET.
FOR DETAILS). I 2' -0" CAPTURE AREA.
4'-0" CAPTURE AREA. — UL CLASSIFIED HOOD,
SEE SCHEDULE.
4' -6"
22 GA. STAINLESS I
STEEL PLATE.
co
COOKING EQUIP. _______ --- -__ I
I r— FINISHED FLOOR.
DELI -
BAKERY
HOOD
SECTION
NOTE: VERIFY
& COORDINATE ALL
INFORMATION
WITH MANUF. SHOP DWGS.
NON RATED
CEILING.
FILL -IN
PANEL
2' -0.,
CAPTURE
AREA. —
HFP -3
r__J
oo
x
00
ROOF DECK
HOOD 2
3' -0" CAPTURE AREA.
6" MIN.
cD
STEAMER
REFER TO DWG. M -3
FOR ADDITIONAL
DETAILS.
6"
22 GAUGE STAINLESS
STEEL PLATE OR TILES
6" MIN.
SEAFOOD HOOD ELEVATION
NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS.
HFP -3
REFER TO DWG M -3 FOR
HOOD PACKAGE DETAIL
GREASE
COLLECTOR. �-
N
FIN. ROOF.-----\
HINGED FAN
BASE
8x8
5/8" DRYWALL ON
METAL STUDS
(NON— COMBUSTIBLE)
HOOD #3 '
(REFER TO DWG M -3
FOR DETAILS).
4' -0" CAPTURE AREA.
4' -0" io
22 GA. STAINLESS I
STEEL PLATE. _--- - ---------- �
I
COOKING EQUIP. ;--- ----- -----;
ROOF DECK.
NON RATED
CEILING.
FILL —IN PANEL.
2' -0" CAPTURE AREA.
— UL CLASSIFIED HOOD,
SEE SCHEDULE.
FINISHED FLOOR.
SEAFOOD HOOD SECTION
NOTE: VERIFY & COORDINATE ALL INFORMATION WITH MANUF. SHOP DWGS.
acN
N
rr^^ W
vl �
t\ �
u (o O
t\ to
0 I- I,r
�
^O w O
j( 00 �g o
L ' I I-L M
H Q ao
Ln
No
w
U Y Ln
• O Z�
U 0)-
QQI r_ :2
Q � 1—
SEAL
�r
z
ell
ti: _
ENGINEERS
C3-: � S� 12
o Lj
z
a
A
•p x
W W 4
_
M
= i•E !
W�
REVISIONS:
a
.,C ,
°I,00 t''
CL (� O
wco
t%) 4
A�
w U)
cc J
o " (D
E
Q
® U
A
A
0
PROJECT NO.
WD #0704
DRAWING NO.
M-5* OF —
SHEET NO.
OF —
FF(nwy-
p �
W
Fh
O
�
W
X
Q
�
�
U)
Z
ILO
�
O
Lo
co
PROJECT NO.
WD #0704
DRAWING NO.
M-5* OF —
SHEET NO.
OF —