02-830-068F N Itt X 0 M I W s i a IL Lo N 0 N •o • N ' O r\ 0 rn 3 0 ul I co N 0 / to 00 N 3 v 3 w 5/8' TYPE 'X" GYP. BOARD 1" FIRE CODE GYP. BOARD SHAFT WALL LINER CORNER SUPPORT CORNER SUPPORT 2 -1/2" 22 GAUGE METAL C -H STUDS VERTICAL AT 16" O.C. ArCf_TV ED ALTERNATE SH*7 CORNER SUPPORT- 3-1/2- METAL DUCT DIMENSION PLUS STUD (TYPICAL) 12" MIN SHEET ROCK SCREWS: iO z (TYPICAL), INSTALL (n INTERIOR SCREWS a XEXHAUSTT- FIRST SHEET ROCK: 5/8" TYPE X, GYPSUM (°-n 6" 6" BOARD (2) LAYERS, MIN MIN (4) SIDES CCESS PANELS; IN BOTH �' DUCT do ENCLOSURE U o FIRE STOP: UL ' Z APPROVED SEALANT (TYPICAL) CORNER SUPPORT GREASE DUCT ENCLOSURE DETAIL (WHERE REQUIRED BY LOCAL AUTHORITY) 1. GYPSUM DUCT ENCLOSURE BY GENERAL CONTRACTOR. 2. ACCESS PANEL SHALL BE LOCATED AT EVERY CHANGE IN DIRECTION. PANELS SHALL BE 16 GAGE, WITH 1/4 -20 BOLTS WELDED ON INSIDE WITH WING NUTS ON THE OUTSIDE, WITH HIGH TEMPERATURE GASKET. PROVIDE "KARP" FIRE -RATED ACCESS PANEL IN THE SHEET ROCK PER UL APPROVED MANUFACTURERS INSTALLATION INSTRUCTIONS. 3. REQUIRED AT HOODS /2. 3 4. GREASE DUCT ENCLOSURE SHALL ONLY BE PROVIDED WHERE REQUIRED BY AUTHORITY HAVING JURISDICTION. DISCONNECT SWITCH (U.L) WOOD NAILER SECURE FAN TO CURB W/ 1/8 "0 BOLTS, 18" ON CENTER ALL AROUND. (MIN 2 PER SIDE) PREFABRICATED CURB ROOFING EXTENDED UP & OVER TOP OF CURB SECURE CURB TO ROOF USING 3/16" THRU BOLTS W/ WASHERS do NUTS, 18" ON CENTER ALL AROUND (MIN. 2 PER SIDE) STEEL PLATE BACKDRAFT DAMPER DUCTWORK TYPICAL ROOF FAN MOUNTING DETAIL NTS FAN 1/4" RUBBER GASKET BETWEEN CURB AND NAILER PRESSURE TREATED WOOD (ALL AROUND OPENINGS) ROOF CONSTRUCTION ROOF STRUCTURE 2x2x1/4" STEEL ANGLE FRAME ALL AROUND ROOF OPENING EXTENDED TO ROOF JOISTS AND WELDED TO JOISTS AND METAL DECK TOP JOIST CLAMP GRINNELL FIG. 227 (R TnTAI l HOOD HANGING DETAIL FAN MOTOR FAN WHEEL :I[:Ir>�aN�Oi z_ o L) HINGED W FAN BASE— CL COMBINATION ROOF CURB UNIT BY M.C. INSTALLATION/WATER- PROOF'G BY G.C. — ALUMINUM HOUSING � I EXHAUST � I 10'-O"-MIN REMOVABLE TOP -� ELECTRICAL CONTROL PACKAGE W /CONTACTORS AND TERMINAL BLOCKS FOR POWER AND CONTROL (120/1/60) FACTORY INSTALLED. ALARM SHALL SHUT DOWN FAN AND RUN EXHAUST FAN CONTINUOUSLY ( I I SUPPLY / I / I � i - - - - -� / I / I — STRUCTURAL SUPPORT BY G.C. I I I I J "I- BURGLAR BARS WOOF 16 GA CONT WELDED OPENINGS TYP. BY G.C. DUCT FROM HOOD COORDINATE w/M.C. (SEE PLAN FOR SIZE) HOOD SUPPLY /EXHAUST FAN DETAIL NTS EXHAUST AIR DUCT' GALVANIZED SHEET METAL SEALED WITH MASTIC MA EXHAUST AIR PLENUM TRUNKLINE LENGTH AS REQ'D BY CODE TRUNKLINE W /FILTERED INLET SUPPORT RAILS AS REQ'D BY M.C. WATERPROOFING BY G.C. GALVANIZED TRUNK LINE /a / FILTERS: / WASHABLE ALUMINUM / ELECTRIC DUCT HEATER, THERMOSTAT CONTROLLED TO MAINTAIN 707 SUPPLY AIR TEMPERATURE. DUCT HEATER SHALL BE INTERLOCKED WITH MAKE -UP AIR FAN 1. PROVIDE EACH FAN W /INTERNALLY PROTECTED MOTOR 2. PROVIDE EACH FAN W /FACTORY MOUNTED AND WIRED DISCONNECT SWITCH CEILING (SEE ARCH. DWGS FOR HEIGHT) L LL -IN PANEL, FROM TOP OF HOOD THRU CEILING. ALL EXPOSED SIDES '---1 /2 "HANGER RODS TO STRUCTURE ABOVE HOOD SUPPORT: PROVIDE BACKING IN WALL, TO FLOOR. (2) STAINLESS STEEL. 1/2" BOLT SETS INTO INSERTS, 6" BELOW TOP OF HOOD. HOOD 2 NTS NOTES: 1. HOOD SHALL BE BY THE SAME MANUFACTURER AS THE GREASE HOODS. FINISH SHALL MATCH THE GREASE HOODS. CONSTRUCTION SHALL BE TO NSF STANDARDS. HVAC DESIGN REQUIRES: YES NO NOTE: * FAN, OUTSIDE AIR INTAKE, - OR ROOF EXHAUST CAP: MECHANICAL SUBCONTRACTOR SHALL FASTEN TO CURB WITH PROVIDE ITEMS NOTED WITH * SCREWS GENERAL CONTRACTOR SHALL FIRE RATED ENCLOSURE - PROVIDE ITEMS NOTED WITH ** * RESSURE- TREATED - ** COUNTER FLASHING STRIP WOOD NAILER STRIP - I/ SMOKE CONTROL - I/ ** Y CANT STRIP * HEIGHT OF CURB ABOVE HEAT z ** ROOFING ROOF DECK: B ALL FANS SHALL BE COMPLETE WITH DISCONNECT SWITCH AND CURB. EXHAUST FAN MFG OD I 8" FOR STANDARD FANS DU30HFA CURB FOR BOTH THE EXHAUST AND MAKE -UP AIR FANS AND INTAKE TRUNKUNE do HOODS WITH RAIL AND FILTERS. ;,• 18" FOR GREASE EXHAUST 0 :.<<_..�. ''�''"' ;..�..��:;:;.;��;�:: >M�.; ---�'* ROOF INSULATION FANS -- ** METAL DECKING * CURB: DUCT SIZES SHOWN ON PLAN. 18 GAGE GALVANIZED STEEL, ** STRUCTURAL SUPPORT FRAME, WELDED. RIGID D INSULATION. UNIT do DECKING, AT 3624 VH -1 FULL PERIMETER OF FACTORY CURB * CURB SET ON TOP OF METAL DECKING Al CURB DETAILS FAN OR GRAVITY VENTILATOR 1. CURBS NOTED ABOVE DO NOT NEED TO BE SET LEVEL, AND CAN BE SET WITH THE PITCH OF THE ROOF. 2. REFER TO FAN DETAIL FOR BOLTING REQUIREMENTS TOP JOIST CLAMP GRINNELL FIG. 227 (R TnTAI l HOOD HANGING DETAIL FAN MOTOR FAN WHEEL :I[:Ir>�aN�Oi z_ o L) HINGED W FAN BASE— CL COMBINATION ROOF CURB UNIT BY M.C. INSTALLATION/WATER- PROOF'G BY G.C. — ALUMINUM HOUSING � I EXHAUST � I 10'-O"-MIN REMOVABLE TOP -� ELECTRICAL CONTROL PACKAGE W /CONTACTORS AND TERMINAL BLOCKS FOR POWER AND CONTROL (120/1/60) FACTORY INSTALLED. ALARM SHALL SHUT DOWN FAN AND RUN EXHAUST FAN CONTINUOUSLY ( I I SUPPLY / I / I � i - - - - -� / I / I — STRUCTURAL SUPPORT BY G.C. I I I I J "I- BURGLAR BARS WOOF 16 GA CONT WELDED OPENINGS TYP. BY G.C. DUCT FROM HOOD COORDINATE w/M.C. (SEE PLAN FOR SIZE) HOOD SUPPLY /EXHAUST FAN DETAIL NTS EXHAUST AIR DUCT' GALVANIZED SHEET METAL SEALED WITH MASTIC MA EXHAUST AIR PLENUM TRUNKLINE LENGTH AS REQ'D BY CODE TRUNKLINE W /FILTERED INLET SUPPORT RAILS AS REQ'D BY M.C. WATERPROOFING BY G.C. GALVANIZED TRUNK LINE /a / FILTERS: / WASHABLE ALUMINUM / ELECTRIC DUCT HEATER, THERMOSTAT CONTROLLED TO MAINTAIN 707 SUPPLY AIR TEMPERATURE. DUCT HEATER SHALL BE INTERLOCKED WITH MAKE -UP AIR FAN 1. PROVIDE EACH FAN W /INTERNALLY PROTECTED MOTOR 2. PROVIDE EACH FAN W /FACTORY MOUNTED AND WIRED DISCONNECT SWITCH CEILING (SEE ARCH. DWGS FOR HEIGHT) L LL -IN PANEL, FROM TOP OF HOOD THRU CEILING. ALL EXPOSED SIDES '---1 /2 "HANGER RODS TO STRUCTURE ABOVE HOOD SUPPORT: PROVIDE BACKING IN WALL, TO FLOOR. (2) STAINLESS STEEL. 1/2" BOLT SETS INTO INSERTS, 6" BELOW TOP OF HOOD. HOOD 2 NTS NOTES: 1. HOOD SHALL BE BY THE SAME MANUFACTURER AS THE GREASE HOODS. FINISH SHALL MATCH THE GREASE HOODS. CONSTRUCTION SHALL BE TO NSF STANDARDS. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR I/ - FIRE DAMPER(S) - HEAT SMOKE DAMPER(S) - I/ FIRE RATED ENCLOSURE - I/ FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - ✓ FIRE STOPPING - I/ SMOKE CONTROL - I/ HOOD NOTES: 1. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHT IN KITCHEN. 2. FIRE MODE REQUIRES EXHAUST FAN TO CONTINUE TO OPERATE AND SUPPLY FAN TO STOP. 3. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IS ACTIVATED. 4. PROVIDE AN ALARM INDICATING OPERATION OF THE HOOD AUTOMATIC FIRE SUPPRESSION SYSTEM. 5. PROVIDE A HOOD AUTOMATIC FIRE SUPPRESSION SYSTEM UNDER SEPARATE PERMIT BY OTHERS. 6. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANYONE OF THE SYSTEMS. COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA. EXCEPTION WOULD BE A SECONDARY FIRE SUPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST DUCT. J EXHAUST HOOD DUCTWORK OFFSETS TO GREASE EXHAUST FANS FROM HOOD LOCATION SHALL BE MADE WITH 2 - 45' ELBOWS. TRANSITION TO FULL SIZE OF FAN CONNECTION AT CURB. BILL OF MATERIAL THE FOLLOWING CONTROLS TO BE FURNISHED BY TEMPERATURE CONTROL CONTRACTOR NO. QUANTITY MAKE REMARKS T1 1 (PER UNIT) HONEYWELL T730OA1005 NOTE: FOR MEET ROOM UNIT USE MODEL 0730OAl018 T7300/0730OB1008 (SWITCHING BASE) HONEYWELL T7047CIO25 REMOTE SENSOR (NOTE: EXCEPT MEET ROOM UNIT) T1 T /07aoo S[JBBASE O' 3 RC TERMINAL EQUIPMENT TRANSFORMER � c I I I (IF NO 'C' TERMINAL) LED2 Y2 Y2 cool I 2 Yt Yt cool Two (2) #IS AM SHIELDED, T7047 TWISTED PAIR WARES. SENSOR C MOUNTED. T7300/07300 (CONFIGURED FOR 2H -2C) USED IN SINGLE TRANSFORMER, 2 STAGE HEATING/ 2 STAGE COOLING SYSTEM WITHOUT ECONOMIZER. REMOTE SENSOR NOTE: REMOTE SENSOR (T7047C1025) IS TO BE MOUNTED ON COLUMN (OR WALL), 6' -0" UP. WITH THE SUBBASE (T/07300) LOCATED IN MANAGER'S OFFICE. CONNECT REMOTE SENSOR TO T -T TERMINALS OF SUBBASE VIA TWO (2) 116 AWG SHIELDED. TWISTED PAIR WIRES, BELDEN 8719. SEE CONTROL WIRING DIAGRAM. EXHAUST FAN Eu- SEE EXHAUST FAN SCHEDULE — 8 "0 UP TO EXHAUST FAN EE_2 X3/8" WATER B'0 7 "0 6 "0 --/ OVEN (FAN TO BE CONTROLLED BY SWITCH ON OVEN DOOR) FAN MANUFACTURER. PROGRAM 1 COOLING 76 R OCCUPIED HEAT 72 r UNTIL SUBMITTAL APPROVED BY WINN -DIXIE STORE DESIGN 1 COOLING 85 f NOT OCCUPIED 22 HEATING 60 OF HOOD STATIC PRESSURE 2 8 AM OR AS DIRECTED BY OWNER UNOCCUPIEDO (OFF) yyl AMTEKCO 800 -336 -4677 GREENHECK 1/4 N/A I HEAT z 115V/1e I N/A B ALL FANS SHALL BE COMPLETE WITH DISCONNECT SWITCH AND CURB. EXHAUST FAN MFG OD I C FAN FOR THE GREASE HOODS SHALL BE THE FAN PACKAGE TYPE WITH COMMON DU30HFA CURB FOR BOTH THE EXHAUST AND MAKE -UP AIR FANS AND INTAKE TRUNKUNE SUPPLY FAN MFG/MOO 1 WITH RAIL AND FILTERS. N/A D SINGLE PHASE FANS SHALL INCLUDE BUILT -IN MOTOR OVERLOADS. 0 E COORDINATE EXACT DUCT CONNECTION SIZES AND LOCATIONS WITH G ACTUAL HOODS AND FANS SUPPLIED AND PROVIDE TRANSITIONS TO FAN DUCT SIZES SHOWN ON PLAN. CAPTIVE AIRE AUX HOOD MODEL NO. 3624 VH -1 Al �71mal ES7DE FIELD WIN POWER FROM HVAC FEEDERS WITH FUSED PROTECTION FACTORY WIRING 24 VAC SECONDARY. MUST BE ABLE TO CARRY ADDITIONAL 5 VA LOAD OF O THERMOSTAT AND SUBBASE. O FIELD INSTALLED JUMPER. O 24 VAC ONLY. T7300/07300 (CONFIGURED FOR 2H -2C) USED IN SINGLE TRANSFORMER, 2 STAGE HEATING/ 2 STAGE COOLING SYSTEM WITHOUT ECONOMIZER. REMOTE SENSOR NOTE: REMOTE SENSOR (T7047C1025) IS TO BE MOUNTED ON COLUMN (OR WALL), 6' -0" UP. WITH THE SUBBASE (T/07300) LOCATED IN MANAGER'S OFFICE. CONNECT REMOTE SENSOR TO T -T TERMINALS OF SUBBASE VIA TWO (2) 116 AWG SHIELDED. TWISTED PAIR WIRES, BELDEN 8719. SEE CONTROL WIRING DIAGRAM. EXHAUST FAN Eu- SEE EXHAUST FAN SCHEDULE — 8 "0 UP TO EXHAUST FAN EE_2 X3/8" WATER B'0 7 "0 6 "0 --/ OVEN (FAN TO BE CONTROLLED BY SWITCH ON OVEN DOOR) HVAC CONTROL DIAGRAM (EACH UNIT) NO SCALE "0 7'0 7 "0 1/2 DIST FROM OVEN TO ROOF - STEAM HOOD 6'0 OVEN OVEN: BAKER'S AID BARO -1E, BARO -2E 36 ", OR 24" ABOVE ANY PARAPET WITHIN 10'0 ROOF - STOR COLLAR do ROOF JACK, SEAL ALL SEAMS WITH "PAR -BOND" GUTTER SEAL �•- HEAT AND STEAM REMOVAL VENT- SINGLE WALL, SEAL LIQUID TIGHT WITH MASTIC 4 "0 NOTE: VENT SHALL BE INSTALLED STRAIGHT UP IN THE VERTICAL FLOOR SIDE VIEW OVEN FLUE DETAIL NTS EXHAUST HOOD NOTES 1. EXHAUST HOODS SHALL BE CONSTRUCTED OF 18 GAUGE 304 STAINLESS STEEL FOR ALL SURFACES EXPOSED TO THE AIRSTREAM AND 18 GAUGE GALVANIZED STEEL FOR OTHER SURFACES. ALL SEAMS AND JOINTS SHALL HAVE A LIQUID TIGHT U.L APPROVED CONTINUOUS EXTERNAL WELD. 2. ENTIRE SYSTEM SHALL BE CONSTRUCTED IN ACCORDANCE WITH NATIONAL SANITATION FOUNDATION STANDARDS, NFPA -96, NFPA -17 -A. AND ALL GOVERNING CODES. 3. EXHAUST HOODS SHALL BE PROVIDED WITH A ANSUL R -102 AUTOMATIC FIRE EXTINGUISHING SYSTEM FOR PROTECTION OF THE EXHAUST HOOD, PLENUM, GREASE FILTERS, EXHAUST DUCT AND COOKING EQUIPMENT. THE SYSTEM SHALL EMPLOY A LIQUID CHEMICAL EXTINGUISHMENT. THE SYSTEM SHALL BE ARRANGED TO SHUT OFF THE SOURCE OF COOKING HEAT AUTOMATICALLY UPON SYSTEMS OPERATION. THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA -96, NFPA -17 -A AND ACCORDING TO MANUFACTURERS PRINTED INSTALLATION PROCEDURES. EACH HOOD SHALL HAVE A SEPARATE FIRE EXTINGUISHING SYSTEM WHICH WILL OPERATE EFFECTIVELY WITH OR WITHOUT FANS OPERATING. 4. THE INSTALLER OF THE EXHAUST HOOD AUTOMATIC FIRE EXTINGUISHING SYSTEM SHALL BRIEF THE BAKERY AND DELICATESSEN PERSONNEL IN ITS OPERATION. 5. EXHAUST AND SUPPLY FANS OF EACH HOOD SHALL BE INTERLOCKED. PROVIDE ONE LIGHT SWITCH AND ONE FAN SWITCH ON THE FACE OF EACH GREASE HOOD. 6. GREASE FILTERS TO BE FLAME GARD, INC., STAINLESS STEEL U.L CLASSIFIED FILE i R6593. EXHAUST HOOD SCHEDULE FAN MANUFACTURER. PROGRAM 1 COOLING 76 R OCCUPIED 2� HEATING 72 r UNTIL SUBMITTAL APPROVED BY WINN -DIXIE STORE DESIGN 1 COOLING 85 f NOT OCCUPIED 22 HEATING 60 OF HOOD STATIC PRESSURE OCCUPIED 8 AM OR AS DIRECTED BY OWNER UNOCCUPIEDO (OFF) 10 PM OR AS DIRECTED BY OWNER HVAC CONTROL DIAGRAM (EACH UNIT) NO SCALE "0 7'0 7 "0 1/2 DIST FROM OVEN TO ROOF - STEAM HOOD 6'0 OVEN OVEN: BAKER'S AID BARO -1E, BARO -2E 36 ", OR 24" ABOVE ANY PARAPET WITHIN 10'0 ROOF - STOR COLLAR do ROOF JACK, SEAL ALL SEAMS WITH "PAR -BOND" GUTTER SEAL �•- HEAT AND STEAM REMOVAL VENT- SINGLE WALL, SEAL LIQUID TIGHT WITH MASTIC 4 "0 NOTE: VENT SHALL BE INSTALLED STRAIGHT UP IN THE VERTICAL FLOOR SIDE VIEW OVEN FLUE DETAIL NTS EXHAUST HOOD NOTES 1. EXHAUST HOODS SHALL BE CONSTRUCTED OF 18 GAUGE 304 STAINLESS STEEL FOR ALL SURFACES EXPOSED TO THE AIRSTREAM AND 18 GAUGE GALVANIZED STEEL FOR OTHER SURFACES. ALL SEAMS AND JOINTS SHALL HAVE A LIQUID TIGHT U.L APPROVED CONTINUOUS EXTERNAL WELD. 2. ENTIRE SYSTEM SHALL BE CONSTRUCTED IN ACCORDANCE WITH NATIONAL SANITATION FOUNDATION STANDARDS, NFPA -96, NFPA -17 -A. AND ALL GOVERNING CODES. 3. EXHAUST HOODS SHALL BE PROVIDED WITH A ANSUL R -102 AUTOMATIC FIRE EXTINGUISHING SYSTEM FOR PROTECTION OF THE EXHAUST HOOD, PLENUM, GREASE FILTERS, EXHAUST DUCT AND COOKING EQUIPMENT. THE SYSTEM SHALL EMPLOY A LIQUID CHEMICAL EXTINGUISHMENT. THE SYSTEM SHALL BE ARRANGED TO SHUT OFF THE SOURCE OF COOKING HEAT AUTOMATICALLY UPON SYSTEMS OPERATION. THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA -96, NFPA -17 -A AND ACCORDING TO MANUFACTURERS PRINTED INSTALLATION PROCEDURES. EACH HOOD SHALL HAVE A SEPARATE FIRE EXTINGUISHING SYSTEM WHICH WILL OPERATE EFFECTIVELY WITH OR WITHOUT FANS OPERATING. 4. THE INSTALLER OF THE EXHAUST HOOD AUTOMATIC FIRE EXTINGUISHING SYSTEM SHALL BRIEF THE BAKERY AND DELICATESSEN PERSONNEL IN ITS OPERATION. 5. EXHAUST AND SUPPLY FANS OF EACH HOOD SHALL BE INTERLOCKED. PROVIDE ONE LIGHT SWITCH AND ONE FAN SWITCH ON THE FACE OF EACH GREASE HOOD. 6. GREASE FILTERS TO BE FLAME GARD, INC., STAINLESS STEEL U.L CLASSIFIED FILE i R6593. EXHAUST HOOD SCHEDULE FAN MANUFACTURER. HOOD !I DaU-BAKE iY HOOD N J (SEAFOOD) AIR SYSTEMS (800) 722 -3474 SEE SHT. M -501A EXHAUST SUPPLY UNTIL SUBMITTAL APPROVED BY WINN -DIXIE STORE DESIGN CFM AEROLATOR SYSTEMS, INC. 704- 821 -7605 LARKIN INDUSTRIES 450 N/A 904 -731 -4711 HOOD STATIC PRESSURE 608 - 845 -6411 .02 N/A FAB -X METALS, INC. 800- 677 -3229 LOREN COOK CO. FAN H.P. AMTEKCO 800 -336 -4677 GREENHECK 1/4 N/A ELECTRICAL z 115V/1e I N/A B ALL FANS SHALL BE COMPLETE WITH DISCONNECT SWITCH AND CURB. EXHAUST FAN MFG OD I C FAN FOR THE GREASE HOODS SHALL BE THE FAN PACKAGE TYPE WITH COMMON DU30HFA CURB FOR BOTH THE EXHAUST AND MAKE -UP AIR FANS AND INTAKE TRUNKUNE SUPPLY FAN MFG/MOO 1 WITH RAIL AND FILTERS. N/A D SINGLE PHASE FANS SHALL INCLUDE BUILT -IN MOTOR OVERLOADS. HOOD SIZE E COORDINATE EXACT DUCT CONNECTION SIZES AND LOCATIONS WITH 3' -0" X 4' -0" ACTUAL HOODS AND FANS SUPPLIED AND PROVIDE TRANSITIONS TO HOOD MFG'R DUCT SIZES SHOWN ON PLAN. CAPTIVE AIRE HOOD MODEL NO. 3624 VH -1 * VERIFY FAN OPENING WITH FAN MANUFACTURER. I DESIGN CRITERIA BASED ON MARSHALL AIR SYSTEMS (800) 722 -3474 � THE FOLLOWING ALTERNATE EXHAUST HOOD MANUFACTURERS ARE NOT APPROVED UNTIL SUBMITTAL APPROVED BY WINN -DIXIE STORE DESIGN -4 AEROLATOR SYSTEMS, INC. 704- 821 -7605 LARKIN INDUSTRIES 800- 322 -4036 CAPTIVE -AIRE SYSTEMS, INC. 800- 882 -6626 STANLEY INDUSTRIAL CORP. 904 -731 -4711 SUN -AIR HOODS 800- 633 -4373 CARNES COMPANY 608 - 845 -6411 GREASEMASTER, INC. 704- 821 -9211 PENN VENTILATOR CO. 215 - 464 -8900 FAB -X METALS, INC. 800- 677 -3229 LOREN COOK CO. 417- 869 -6474 AMTEKCO 800 -336 -4677 GREENHECK 715 -355 -2367 Ilm A) FANS FOR GREASE HOODS SHALL BE UL LISTED FOR OPERATION AT 300 'F AND z SHALL CARRY BOTH THE UL762 AND UL705 LABELS. U B ALL FANS SHALL BE COMPLETE WITH DISCONNECT SWITCH AND CURB. L0 C FAN FOR THE GREASE HOODS SHALL BE THE FAN PACKAGE TYPE WITH COMMON Lli CURB FOR BOTH THE EXHAUST AND MAKE -UP AIR FANS AND INTAKE TRUNKUNE �c WITH RAIL AND FILTERS. G D SINGLE PHASE FANS SHALL INCLUDE BUILT -IN MOTOR OVERLOADS. a E COORDINATE EXACT DUCT CONNECTION SIZES AND LOCATIONS WITH ACTUAL HOODS AND FANS SUPPLIED AND PROVIDE TRANSITIONS TO DUCT SIZES SHOWN ON PLAN. r CN !� W rl F_ t\ � U� Ir^\` (o I— M W W O o It ° I V) Hly- Q DO • In o W Y 0 U � • O Z n O %­1 U 0) I r- Q J — W - , SEAL . re A, ENGINEERS . CO w " o_ _ M I I N ^ cis v OLjNMn Z o_ x o W'L Li Li w f- O MEM o om ;2 REVISIONS: REVISIONS: v� N cq yl o�z I d �} o � H~ r-i O to I -4 W M CO A � v 0 rn III W E Am Q I n z U cc L0 :D Lli _Z �c O G a v� N cq yl o�z I V �} o � A r-i O to I -4 W M CO A � v 0 rn III W V X Q W 00 0 V W A 0 cy- 0 0 0 J LL � W V X Q W 00 o L0 :D _Z 0 / DATE: JUNE 17, 2002 DRAWN BY: CHECKED BY: f K Y PROJECT NO. WD #0704 DRAWING NO. M -501 OF - SHEET NO. OF _ W W 0 cy- 0 W � vj 0 J LL � W X Q 00 L0 :D _Z 0 / DATE: JUNE 17, 2002 DRAWN BY: CHECKED BY: f K Y PROJECT NO. WD #0704 DRAWING NO. M -501 OF - SHEET NO. OF _