02-830-0546TfRUCTURAL NOTES GENERAL NOTES: STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. AS A MINIMUM, CONSTRUCTION SHALL COMPLY WITH FLORIDA BUILDING CODE, ACI 318 -99, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI 350, AISI SPECIFICATION FOR THE DESIGN OF COLD - FORMED STEEL STRUCTURAL MEMBERS 1986, AND AISG SPECIFICATIONS. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH THE AFFECTED PART OF THE WORK. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PRO- CEDURES AND SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS. THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREP - ARATION REQIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. DESIGN LOADS: THE STRUCTURAL FRAMING WAS DESIGNED USING THE FOLLOWING SUPERIMPOSED LOADS. DESIGN WIND LOADS WERE DETERMINED IN ACCORDANCE WITH ASCE 7-88. ROOF: LIVE LOAD .... ............................... 30 psf DEAD LOAD .. ............................... 25 psf S LAIM LIVE LOAD .... ............................... 40 psf SUPER IMPOSED LOAD ................ 25 psf WIND: DESIGN WIND SPEED =146 mph EXPOSURE C IMPORTANCE FACTOR 1.0 INTERNAL PRESSURE COEFFICIENT = + 0.181- 0.18 MAX PRESSURE WALL = 49.5 P.S.F. MAX PRESSURE ROOF = 64.5 P.S.F. SHOP DRAWING REVIEW: SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRAC- TOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. - ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE ENGINEER. DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UN- CHECKED. SHOP DRAWINGS IN THE FORM OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON- TRACT DOCUMENTS) ARE PROHIBITED WITHOUT THE EXPRESS WRITTEN PERMISSON FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS UNLESS OTHERWISE SPECIFIED IN WRITING BY THE ENGINEER. CONCRETE: CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: 3,000 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE 3,000 PSI REGULAR WEIGHT FOR BEAMS, AND COLUMNS CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO CONCRETE PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 4"+/- 11" PRIOR TO THE ADDITION OF PLASTICIZER. CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 301 AND ASTM C-94 FOR MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME - STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY REASON THERE IS A DELAY SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL BE DISCARDED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRAC- TOR OF ANY NONCOMPLIANCE WITH THE ABOVE. ALL CONCRETE SHALL BE CURED USING A CURING COMPOUND MEETING ASTM STANDARD C -309, TYPE 1. CURING COMPOUNDS SHALL HAVE A FUGITIVE DYE. THE CURING COMPOUND SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS THE VISIBLE WATER HAS LEFT THE UNFINISHED CONCRETE. ALL SCUFFED OR BROKEN AREAS IN THE CUR- ING MEMBRANE SHALL BE RECOATED DAILY. CALCIUM CHLORIDES SHALL NOT BE UTILIZED IN THE WORK. OTHER ADMIXTURES MAY BE USED ONLY WITH THE APPROVAL OF THE ENGINEER. REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS: A. W FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH B. FOR CONCRETE EXPOSED TO EARTH AND /OR WEATHER: 1 -1/2" FOR #5 AND SMALLER 2" FOR #6 AND LARGER C. FOR CONCRETE NOT EXPOSED TO EARTH OR WEATHER: 314" FOR SLABS, WALLS, AND JOISTS 1 -1/2" FOR BEAM AND COLUMN PRIMARY REINF., TIES, STIRRUPS THE REINFORCEMENT FOR FOOTINGS AND OTHER PRINCIPAL STRUCTURAL MEMBERS IN WHICH CONCRETE IS DEPOSITED AGAINST THE GROUND SHALL HAVE NOT LESS THAN 3 INCHES OF CONCRETE BETWEEN THE REINFORCEMENT AND THE GROUND CONTACT SURFACE. IF CONCRETE SURFACES AFTER REMOVAL OF THE FORM ARE TO BE EXPOSED TO THE WEATHER OR BE IN CONTACT WITH THE GROUND, THE REINFORCEMENT SHALL BE PROTECTED WITH NOT LESS THAN 2 INCHES OF CONCRETE FOR BARS LARGER THAN #5 AND 1 -1/2" FOR #5 OR SMALLER BARS. EXCAVATIONS FOR CONTINUOUS FOOTINGS SHALL BE CUT TRUE TO LINE AND GRADE AND THE SIDES OF FOOTINGS SHALL BE FORMED, EXCEPT WHERE SOIL CONDITIONS ARE SUCH THAT THE SIDES OF THE EXCAVATION STAND FIRM AND SQUARE. EXCAVATIONS SHALL BE MADE TO FIRM, CLEAN BEARING SOLI. WHEN POLYETHYLENE SHEETS ARE USED AS A VAPOR BARRIER BENEATH A GROUND FLOOR SLAB, THE SUB GRADE FOR THAT SLAB SHALL BE CONSIDERED A FORMED SURFACE FOR THE PURPOSE OF REINFORCING STEEL COVERAGE. FORMWORK: FORMWORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347, "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK ". REINFORCING STEEL: r =cv r% of Wt. r%..r I m nv I%j %7r%MVG vv Nr= r- %ar%ivtE:u DMRO, r mcr- 1-RUIVI UIL, 0%,JALC, AIVU RUST AND PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL AND VERTICAL BARS SHALL LAP 6 x BAR NO., UNLESS OTHERWISE NOTED. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEER'S REVIEW. PROVIDE X x T CORNER BARS LAPPED AND TIED TO EACH BEAM REBAR, TYPICAL AT ALL CORNERS. THESE CORNER BARS SHALL BE THE SAME SIZE AS LONGITUDINAL BEAM BARS. SEE DETAILS FOR ADDITIONAL INFORMATION. WELDED WIRE MESH: N WELDED WIRE MESH SHALL BE ASTM A -185, GRADE 65, FREE FROM OIL, SCALE, AND RUST, �r x AND SHALL BE PLACED IN ACCORDANCE WITH THE ACI TYPICAL DETAILS. MINIMUM LAP o SHALL BE ONE SPACE PLUS TWO INCHES. M FOUNDATION /SITE PREPARATION: L THE BUILDING OFFICIAL SHALL BE PROVIDED WITH A STATEMENT OF ALLOWABLE BEARING CAPACITY FROM AN ARCHITECT OR PROFESSIONAL ENGINEER. SAID STATEMENT SHAL CLEARLY Q IDENTIFY THE ALLOWABLE IN -PLACE BEARING CAPACITY OF THE BUILDING PAD FOR THE NEW BUILDING OR ADDITION AND VERIFY THE EXISTING SOIL CONDITIONS. THE CERTIFIED IN -PLACE CL CL BEARING CAPACITY SHALL HAVE BEEN DETERMINED BY WAY OF RECOGNIZED TEST OR RATIONAL ANALYSIS. Qi THE MAXIMUM SIZE OF ROCK WITHIN 12 INCHES BELOW THE FLOOR SLAB IN COMPACTED FILL %q SHALL BE 3 INCHES IN DIAMETER. WHERE FILL MATERIAL INCLUDES ROCK, LARGE ROCKS SHALL o NOT BE ALLOWABLE TO NEST AND ALL VOIDS SHALL BE CAREFULLY FILLED WITH SMALL STONES N OR SAND, AND PROPERLY COMPACTED. WHEN FOUNDATION WALL ARE TO BE POURED SEPARATELY FROM THE FOOTING, THEY SHALL BE KEYED AND DOWELED TO THE FOOTING WITH NO LESS THAN #4 DOWELS, 20 DIAMETERS IN LENGTH ABOVE AND BELOW THE JOINT, SPACED NOT MORE THAN 4 FEET APART. WHERE FOOTING DEPTH DOES NOT ALLOW STRAIGHT DOWELS, STANDARD HOOKS WILL BE ALLOWABLE. rn FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF, v ACCORDING WITH GEOTECHNICAL REPORT. DONE BY ADVANCE ENGINEERING V) & TEST CONSULTANTS INC. P.O. BOX 3561 - HALLANDALE, FL. 33008 Li o PHONE (305) 606 -3408 - FAX (305) 457 -7932 z FOOTING EXCAVATIONS AND SLAB SUBGRADE SHALL BE COMPACTED TO A DRY DENSITY I N OF AT LEAST 98% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN I ACCORDANCE WITH ASTM D -1557. uj Ib N D 3 Ib N 0 3 w MASONRY: ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK MANUFACTURED IN CONFORMANCE WITH ASTM C -90, GRADE N, fm =1500 psi. BLOCK SHALL BE PLACED USING RANDOM BOND UNLESS OTHERWISE NOTED. LAY -UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE PLACING CONCRETE FOR IN -WALL COLUMNS. THE ENGINEER SHALL FURNISH INSPECTION OF ALL REINFORCED MASONRY STRUCTURES. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 psi AT 28 DAYS. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8" COARSE AGGREGATE, AND SHALL BE PLACED WITH A SLUMP OF 8" TO 10 ". USE ONLY MECHANICAL VIBRATION TO CONSOLIDATE GROUT. TYPE S MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C -270. HORIZONTAL AND VERT. MORTAR JOINTS SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO CELLS TO BE FILLED. ALLOW A MINIMUM 72 HOURS FOR MORTAR TO CURE PRIOR TO GROUTING CELLS. HORIZONTAL MORTAR JOINTS SHALL BE REINFORCED WITH STANDARD 9 GAGE LADUR -TYPE DUR -O-WAL (ASTM CLASS B -2, HOT - DIPPED GALVANIZED) AT ALTERNATE COURSES (16" ON CENTER), UNLESS OTHERWISE NOTED. JOINT REINFORCEMENT SHALL BE CONTINUOUS AND SHALL LAP A MINIMUM 8 ". THIS REINFORCEMENT SHALL EXTEND 4 INCHS INTO TIE COLUMNS OR BE TIED TO STRUCTURAL COLUMNS WITH APPROVED METHODS WHERE STRUCTURAL COLUMNS REPLACE THE TIE COLUMNS. LAP VERTICAL REBAR 6 x BAR NO., U.O.N. MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE "SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530.1- 92/ASCE 6- 92/TMS 602 -92), AS PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE. t. MASONRY CONSTRUCTION SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION OF A "CERTIFIED STRUCTURAL MASONRY CONTRACTOR ". THE SUPERVISOR OF THE MASONRY • PQRTION OF THE PROJECT SHALL BE A "CERTIFIED STRUCTURAL MASONRY CONTRACTOR" OR A "CERTIFIED STRUCTURAL MASON" AS RECOGNIZED BY THE FLORIDA CONCRETE AND PRODUCTS ASSOCIATION (FC &PA). THE SENIOR MASONRY SUPEnvt::,:!P'NIL, Sc.RL::FONSIBLE TO ASSURE THAT THE WORK IS ACCOMPLISHED IN ACCORDANCE WITH THE CONTRACT DOCU- MENTS. THE MASONRY CONTRACTOR SHALL SUBMIT CREDENTIALS FROM THE FC &PA TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO BIDDING. STRUCTURAL STEEL: THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUC- TURAL STEEL FOR BUILDINGS, 9th EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM A36, Fy = 36 ksi FOR ANGLES, PLATES, AND W- SHAPES. STRUCTURAL TUBING SHALL BE ASTM A -500, GRADE B, Fy = 46 ksi. STRUCTURAL PIPE SHALL BE ASTM A -53, GRADE B, TYPE E OR S, Fy = 35 ksi. TUBE AND PIPE COLUMNS SHALL BE CONCRETE- FILLED IN THE SHOP. ANCHOR BOLTS AT COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL OTHER BOLTS SHALL BE ASTM A325 -N BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN - OF- THE -NUT METHOD. WELDING SHALL BE DONE BY AWS CERTIFIED WELDERS USING THE MOST RECENT AWS APPROVED TECHNIQUES. SHIELDED METAL ARC WELDING (SMAW) SHALL USE E70XX LOW- HYDROGEN ELECTRODES. ALL STEEL SHALL RECEIVE SHOP AND FIELD TOUCH -UP COATS OF PAINT IN ACCORDANCE WITH SSPC SPECIFICATIONS. WOOD 1. ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BLOCKING, BRACING, LEDGERS, CRIPPLES, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2, KD -15, OR BETTER. 2. MICRO -LAM BEAMS SHALL BE MANUFACTURED BY TRUS -JOIST CORP., OR APPROVED EQUAL, AND SHALL PROVIDE A MODULUS OF ELASTICITY OF 2,000,000 psi, A MIN. FLEXURAL STRESS OF 2,925 psi, AND A MIN. HORIZONTAL SHEAR STRESS OF 285 psi. 3. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE PRESSURE - TREATED. WOOD FOR NON - STRUCTURAL USES SHALL BE RATED TO RETENTION LEVELS OF 0.25 PCF OF CHROMATED COPPER ARSENATE (CCA). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY REASON SHALL BE RATED TO RETENTION LEVELS OF 0.4 PCF OF CCA OR MORE. 4. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT CONTAINS MORE THAN 1/2" OF HEARTWOOD. 5. AVOID INHALATION OF SAWDUST PRODUCED BY PRESSURE TREATED WOOD. WEAR A DUST MASK AND WORK OUTDOORS. DISPOSE OF DUST AND SCRAP BY ORDINARY TRASH COLLEC- TION. DO NOT BURN IT: PRESSURE TREATED WOOD MAY PRODUCE VERY TOXIC FUMES. 6. IN HIGHLY CORROSIVE ENVIRONMENTS, ALL WIND RESISTING HARDWARE INCLUDING THE HURRICANE STRAPS, SHALL BE MADE OF STAINLESS STEEL, OR SHALL BE DIPPED (AND SCRATCHES RE- PAINTED) IN COAL -TAR EPDXY PAINT. 7. WOOD PREVIOUSLY USED AS FORMWORK SHALL NOT BE USED AS ROOF FRAMING OR SHEATHING. 8. HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 9. HANGERS OR STRAPS THAT DO NOT MATCH EXACTLY THE ONES SPECIFIED ON THE DRAW- INGS IN STEEL YIELD OR ULTIMATE STRENGTH, STEEL DIMENSIONS (LENGTH AND WIDTH), NUMBER AND DIAMETER OF HOLES FOR THE SAME SIZES OF NAILS OR BOLTS, AND /OR DO NOT HAVE THE SAME GENERAL SHAPE, WILL NOT BE ACCEPTABLE. 10. NO POCKETS WILL BE ALLOWED IN CONCRETE OR STEEL MEMBERS FOR CONNECTION OF WOOD MEMBERS UNLESS THE CONNECTION DETAIL IS IN WRITING PRIOR TO INSTALLATION. 11. ALL NAILS, SCREWS, AND BOLTS SHALL BE HOT - DIPPED GALVANIZED. WOOD TRUSSES 1. TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPEC- IFICATIONS FOR STRESS -GRADE LUMBER AND ITS FASTENINGS" BY THE NFPA, TRUSS DESIGNS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTES FOR SHOP DRAWINGS. 2. CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036" AND BE MANUFACTURED FROM STEEL MEETING THE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT - DIPPED GALVANIZED. 3. IN HIGHLY CORROSIVE ENVIRONMENTS, CONNECTOR PLATES AS WELL AS THE HURRICANE STRAPS AND ALL THE NAILS, SHALL BE MADE OF STAINLESS STEEL. 4. HANDLING, ERECTION AND BRACING OF TRUSSES SHALL BE IN ACCORDANCE WITH TRUSS PLATE INSTITUTE RECOMMENDATIONS. 5. HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 6. CONNECTORS OR STRAPS THAT DO NOT MATCH EXACTLY THE ONES SPECIFIED IN THE DRAWINGS REGARDING STEEL YIELD OR ULTIMATE STRENGTH, STEEL GAGE, DIMENSIONS (LENGTH AND WIDTH), NUMBER AND DIAMETER OF HOLES FOR THE SAME SIZES OF NAILS OR BOLTS, AND /OR DO NOT HAVE THE SAME GENERAL SHAPE, WILL NOT BE ACCEPTABLE. 7. IN THE EVENT OF A SCISSORS OR "A" TRUSS, OR ANY TRUSS OR GIRDER TRUSS USED AS PART OF A "CATHEDRAL CEILING "; TRUSS MANUFACTURER SHALL SUBMIT SIGNED AND JtALtu UALL;ULA I IONS OF HORIZONTAL THRUST, HORIZONTAL AND VERTICAL DEFLECTIONS FOR DEAD AND AND LIVE LOADS SEPARATELY. WALLS, BEAMS, AND COLUMNS HAVE NOT BEEN DESIGNED TO RESIST ANY HORIZONTAL LOADS RESULTING FROM DEFLECTION OF TRUSSES, THEREFORE THOSE LOADS MUST BE REDUCED TO A MINIMUM. 8. ALL SCISSORS OR "A" TRUSSES AND GIRDER TRUSSES, AND ALL TRUSSES AND GIRDER TRUSSES USED AS PART OF ANY "CATHEDRAL CEILINGS" SHALL BE NAILED PERMANENTLY TO HURRICANE STRAPS ONLY AFTER ALL DEAD LOADS, INCLUDING ANY ROOF TILES, ARE IN PLACE. PRIOR TO PERMANENT NAILING, ALL HURRICANE STRAPS MUST BE FREE (TO ALLOW FOR TRUSS DEFLECTION). ROOFS WITH CLAY TILES SHALL BE SPRINKLED WITH AN ABUNDANT AMOUNT OF WATER FOR AT LEAST 1 HOUR BEFORE THE PERMANENT NAILING OPERATION CAN START. THE ROOF SHALL BE CONSTANTLY SPRINKLED WITH WATER DURING THE OPERATION. THE CONTRACTOR WILL BE ALSO RESPONSIBLE FOR KEEPING THE ROOF SAFELY IN PLACE IN THE EVENT OF HIGH WINDS OR OTHER TRANSIENT LOADING CONDITIONS DURING CONSTRUCTION. * ** FAILURE TO COMPLY WITH THESE PARAMETERS WILL MAKE THE CONTRACTOR SOLELY RESPONSIBLE FOR ANY AND ALL CONSEQUENTIAL DAMAGES CAUSED BY THE HORIZONTAL THRUST DEVELOPED BY THE ROOF FRAMING DUE TO SUPERIMPOSED LOADING AND TRANSFERRED INTO THE BEAMS, WALLS AND COLUMNS. *** 9. CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS OF ALTERNATE CONNECTION DETAILS AT TRUSSES /GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. 10. THE ARCHITECT AND ITS CONSULTANTS OR DESIGN PROFESSIONALS WILL NOT BE RESPOW SIBLE FOR ANY DAMAGE CAUSED AS A CONSEQUENCE OF TERMITE INFESTATION. THE OWNER SHALL PROVIDE DUE CARE AND INSPECTIONS TO DETECT TERMITE INFESTATION EARLY ENOUGH TO KEEP THE STRUCTURE SAFE. 11. THE LOCATIONS OF GIRDERS AND TRUSSES SHOWN ON THE ROOF FRAMING PLAN WERE USED TO FACILITATE DESIGN OF FOUNDATIONS, WALLS, AND BEAMS. THE CONTRACTOR SHALL SUBMIT TRUSS SHOP DRAWINGS FOR REVIEW BY THE STRUCTURAL ENGINEER OF RECORD. THE TRUSS FABRICATOR SHALL PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BYA FLORIDA LICENSED PROFESSIONAL ENGINEER. 12. FOR TRUSSES HAVING AN OVERALL LENGTH OF THE BOTTOM CHORD IN EXCESS OF 35 FEET OR 6 FEET OVERALL HEIGHT ERECTION SHALL BE SUPERVISED BY A REGISTERED PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR. TERMITE PROTECTION ALL BUILDINGS SHALL HAVE PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES. THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES SHALL BE DEEMED AS APPROVED WITH RESPECT TO PRE - CONSTRUCTION SOIL TREATMENT FOR PROTECTION AGAINST SUBTERRANEAN TERMITES. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT. 4#5 BARS I1� 0 FOUNDATION NOTE5 FRODUCT CONTfROL AFFROVAL AND 1) STRUCTURAL CONCRETE SHALL CONFORM WITH ACI -301 IT SHALL REACH A MINIMUM COMPRESSIVE STRENGTH 5 �4 ®f DRAWING N OF 3,000 PSI IN 28 DAYS FOR SLABS FOR BEAMS AND COLUMNS 2) AGGREGATES SHALL BE CLEAN AND GRADED MAXIMUM SIZES 3/4" CONCRETE ASTM C -33 SHALL CONFORM TO ALL APPROVED SHOP DRAWINGS SHALL BE REVIEWED BY THE ENG. OF RECORD AND ASTM C -94 SUBMITTED AND PROCESSED AT THE BUILDING DEPARTMENT. 3) CONCRETE TESTING IS REQUIRED AS FOLLOWS: 1 SET OF 5 CYLINDERS FOR EVERY 50 CU. YDS. OF CONCRETE PRODUCT CONTROL APPROVAL AND SEPARATE BUILDING PERMITS SHALL BE REQUIRED AS PER ASTM C -94 FOR THE FOLLOWING ITEMS: 4) MAXIMUM PERMISSIBLE SLUMP IS 5 -6" IN STRUCTURAL CONCRETE WITH THE EXCEPTION BEING SAND CEMENT WINDOWS, DOORS & STORM SHUTTERS; WOOD TRSSES; RIDGE VENTILATION & SKYLIGHTS; GROUT GLASS WALLS & STOREFRONTS; RAILING & HANDRAILS; ROOFING. 5) REINFORCING STEEL SHALL CONFORM TO ASTM A -615 GRADE 60. REINFORCING STEEL SHALL BE DETAILED AND FABRICATED ACCORDING TO THE " MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE NOTE: STRUCTURES ". HOOK ALL DISCONTINUOUS TOP REINFORCING. PROVIDE CORNERS WITH 2# 5 X 5' -0" BEND. NO OTHER UNDERGROUND UTILITIES WERE LOCATED BUT MAY BE PRESENT.- DIG WITH CLEAR COVER FOR REINFORCING BARS SHALL BE: BEAM w CAUTION.- CALL UTILITY LOCATION CENTER BEFORE YOU DIG. G. BEAMS .......................... 3" UNFORMED FACES .... 3" W SLABS ......................... 3/4" FORMED FACES IN • BEAMS /COLUMNS ...... 1 1/2" CONTACT W /EARTH..... 2" r ALL DIMENSIONS REFERENCE TO AFRCHITECTUfRAL DRAWING TIE BEAM o °d d, o o • .I ° c �,, e I d o o V e N 17 CONC. BLK. W LL I I :5 2#5 additional II I A" I TIES #3C. I w OPENING % I >j 3 TO 8 1#51N BLOCK - FILLED CELL TIE BEAM DROP OVER OPENING SCALE: N.T.S. 2#5X30" ADD'L. CORNER BARS -4 #3 STIRRUPS @ 12" O.C. BALANCE #3 @ 48" O.C.(U.O.N.) WALL TIE BEAM SEE PLAN CORNER REINFORCING DETAIL FOR ALL TIE BEAMS DUR -O -WALL CORNER DETAIL HORIZONTAL lY OTHER COURSE 1 #5 FILL CELL CORNER REINFORCING DETAIL FOR ALL FOUNDATION TYPICAL COLUMN REBAR PLACEMENT DIAGRAM N.T.S. WALL FRAMING AT DOOR AND WINDOW OPENINGS N.T.S. U TYPICAL CONSTRUCTION JOINT -1 1/2" DEPRESSION Nz 9 GAUGE DUR -O -WALL HORIZONTAL REINFORCEMENT EVERY OTHER COURSE (LADDER TYPE) 1 # 5 A 48" o/c � ,l�j� I � BOND BEAM HEAD JOISTS FILLED SOLID DOWELS EXTEND 30" FROM FOUNDATION O CLEANOUTS TO BE SEALED AFTER INSPECTION REQUIRED AT ALL CELLS IF POURED IN LIFTS EXCEEDING 2'- 0" 1 1 (D aN r� W vl D L V) u N O I- M CD W O W 0 O � � In � (n W � HQ� co In • In N W u o Y In • Z� � O U O 0)- QQI �Q � SEAL I4 ENGINEERS co w W rM 0 1oY In In�o° T z c", L � In w - ��+' 4 aj %n a 0 o= U M� 0 z REVISIONS: I I ROOF BEAM DROP SLAB OR BEAM SOFFIT AS b N W READ. TO ACCOMMODATE OPENING rrwvlUr- JALrLUI I IUrvr1L ZfFa aU 1. LIJ cc E SLAB OR / AND #3 @ 9" TIES H o0 ACD CL BEAM w w W HOOK COLUMN BARS ago r o Wrn J U W W \ � ct J � w Al I LRMINATION O E I Q ®o V ® PROVIDE 1 #5 IN V A o ko CONCRETE FILLED CELL Z O 0 o IN ADJACENT TO OPENING SEE COLUMN SCHEDULE FOR REINFORCING SIZE &QUANTITY OPENING: WINDOW COLUMN DOWELS ARE OR DOOR SAME SIZE, QUANTITY AND SPACING AS COLUMN REINFORCING BARS �LWCMU WALL a SLAB OR " BEAM `* FOOTING SEE PLAN COORDINATE LOCATION AND GEOMETRY OF OPENING'S WITH ARCHITECTURAL DRAWINGS. TYPICAL COLUMN REBAR PLACEMENT DIAGRAM N.T.S. WALL FRAMING AT DOOR AND WINDOW OPENINGS N.T.S. U TYPICAL CONSTRUCTION JOINT -1 1/2" DEPRESSION Nz 9 GAUGE DUR -O -WALL HORIZONTAL REINFORCEMENT EVERY OTHER COURSE (LADDER TYPE) 1 # 5 A 48" o/c � ,l�j� I � BOND BEAM HEAD JOISTS FILLED SOLID DOWELS EXTEND 30" FROM FOUNDATION O CLEANOUTS TO BE SEALED AFTER INSPECTION REQUIRED AT ALL CELLS IF POURED IN LIFTS EXCEEDING 2'- 0" 1 1 (D aN r� W vl D L V) u N O I- M CD W O W 0 O � � In � (n W � HQ� co In • In N W u o Y In • Z� � O U O 0)- QQI �Q � SEAL I4 ENGINEERS co w W rM 0 1oY In In�o° T z c", L � In w - ��+' 4 aj %n a 0 o= U M� 0 z REVISIONS: DRAWING TITLE r DATE: JUNE 17, -2002 DRAWN BY: CHECKED BY: DIVISION MIAMI LOCATION NO. 285 W.D. GUIDE PLAN PROJECT NO. WD #0704 DRAWING NO. S S OF SHEET NO. OF . ,• 'CGS � �ijlrtsv f :7` . 1 _ - 0Na• 5 N I I d b N W CV LIJ cc E H o0 ACD CL 'o w w W I (o ago z w o Wrn J U W W \ � ct J � w O E I Q ®o V ® A o V A o ko Z O DRAWING TITLE r DATE: JUNE 17, -2002 DRAWN BY: CHECKED BY: DIVISION MIAMI LOCATION NO. 285 W.D. GUIDE PLAN PROJECT NO. WD #0704 DRAWING NO. S S OF SHEET NO. OF . ,• 'CGS � �ijlrtsv f :7` . 1 _ - 0Na• 5 N I I W LIJ ,a Ci cn 'o � Cn Z O 0 o DRAWING TITLE r DATE: JUNE 17, -2002 DRAWN BY: CHECKED BY: DIVISION MIAMI LOCATION NO. 285 W.D. GUIDE PLAN PROJECT NO. WD #0704 DRAWING NO. S S OF SHEET NO. OF . ,• 'CGS � �ijlrtsv f :7` . 1 _ - 0Na• 5 N