Loading...
02-830-0365 N v X 0 M I w -C i a CL 0 0 N 0 rn t` 0 rn 3 co 0 0 Q I UJ ro N D L0 00 N O 3 v 3 w I 5 18" EXT DI VIA /t'1nn SHEATF METAL STUD STAINLESS STEEL L- BRACKETS 2 "X 3"X 3/16" BRACKETS THRU BOLTED TO LETTERS WITH STAINLESS STEEL BOLTS. ( TYPICAL) I.IA" CVT DI VIA 1♦1/11'1 51 FLEXIBLE LIQUID TIGHT CONDUIT FURNISHED ON LETTER. CONNECTIONS BY ELECTRICAL CONTRACTOR. — REFER BLDG. SIGN SHEET 36' -1' WINN FDI.XI.9 v BUILDING IGN- BS9 T.S. (o' TUR9) — ACCESS— PANELS EACH SIDE 12" SQUARE STRUCTURAI POLES 13'-8" APHO T N BUILDING SIGN- BS6 N.T.S. (7" RETURNS) 8'a" PYLON SIGN N.T.S. REFER BLDG. SIGN SHEET 2 CHANNEL LETTERS SECTION DETAIL 23'-6" MARKETPLAC BUILDING SIGN- BS3 N.T.S. (7" RETURNS) FOO N BUILDING SIGN- BS4 N.T.S. (7" RETURNS) 22'-4" PHARMACY BUILDING SIGN- BS5 N.T.S. (7" RETURNS) 15' -0" i__" 01-1 " �4 COLORS LETTERS: TO MATCH, ATOHAAS #2328 WHITE WITH BLACK OUTLINE BACKGROUND: TO MATCH, ATOHAAS 42793 RED FONT BOOKMAN OLD STYLE, BOLD, ITALIC ABS INSERT TO BE SIZED AS NEEDED TO PREVENT CRUSHING OF E.I.F.S. 3 MOUNTING DETAIL 506 N.T.S. SPECIFICATIONS CHANNEL LETTERS • RETURNS (Sides) to be minimum .050 thick aluminum 7" or 10" (Refer: Building Sign Plans). .050 aluminum shall receive MIG welded construction 1" on center with fill seam to protect from weather. .063 aluminum shall receive continuous weld. Returns shall be acid or mechanically etched, primed and sprayed finished with Dupont (or better) automotive type finish. Color to match Mathews, Brushed Aluminum 41 -342. Each upright portion of the letters is to receive a 3/16" weep hole. • BACKS of letters to be minimum .063 thick aluminum. Reinforcement of channel letters with 4" high aluminum gussets epoxied or welded to inside wall of letter also serves as neon tube support base. • PAINT FINISH All interior aluminum components to be acid or mechanically etched, primed and sprayed finished with Dupont (or better) automotive type finish. Color: White gloss for maximum illumination. • FACE OF LETTERS 24 "or more high to be 0.150 Implex or Crylex brand acrylic plastic heat formed to a depth of 1 Y ". Color to match AtoHaas #2793 Red. • FACE OF LETTERS Less than 24" in height to be 4.5mm flat Implex brand acrylic plastic or 0.150 Flat Crylex brand acrylic plastic. Color to match AtoHaas #2793 Red. • FONT is to be Bookman Old Style, Bold, Italic. • RETAINER CAP for letters 24" or less in height to be plastic coated aluminum jewel trim, Color: Black. (Standard industrymethod). • RETAINER CAP for letters 24" or greater in height to be to 1/2"x 3/4" x .063 extruded aluminum angle bonded to sign face with 3M or Lord epoxy. Color: Black. • NEON tubing to be 15 mm clear voltarc glass with 45 M. A. electrodes for letters to be driven at 30 M.A. Any letters that require 60 M.A. transformers shall have 90 M.A. rated electrodes. All letters are required to have a minimum of two strokes of neon. On larger letters, all neon tubes shall be spaced at min. 4' center to center, with the outside tube being no more than 1 -1/2 from the letter wall. Tube supports to be aluminum or brass base fastened to W VIIIU VVllll LID 11VII0. nn nGVII IMIII.J, dIV W UC liaunt:atuu III accordance to Eurocom specifications, utilizing EuroLite or EGL ceramic collar electrodes and H Gas. Tube processing shall be performed on an electronically controlled bomborder at 30,000 volts, at a tube pressure of no more than 2 millitorr. Pumping shall be performed on turbo molecular pump to achieve a tube pressure of .8 millitorr. • ELECTRICAL All high voltage wiring shall be 100 percent pure silicone, heavy duty Tough Hide GTO cable rated for 15,000 volts. For exterior wiring requirements, conduit shall be aluminum Liquid - Lite. All wiring and components are to be UL approved. Connection 900 watertight connector and "sealtight" flexible conduit to be field verified (6' to 12). Wire to be #12 THHN stranded copper. • TRANSFORMER Pi3KM type France (or approved equal) transformers shall be used on all letters not mounted on raceways. D -2 housings in lieu of jumps shall be used on the internal wiring of letters. Transformers to be 30 M.A. and are not to exceed 9,000 volts secondary power output. Transformers shall be loaded as per manufacturers' recommendations. • STAND OFF MOUNTING OPTIONS Refer Detail • FLUSH MOUNTING OPTION Refer Detail • RACEWAY MOUNTING OPTION Refer Detail • DISCONNECT TOGGLE SWITCH Each branch circuit supplying a set or sets of letters will have an external and visible disconnect switch as per NEC 600 -6. The switch shall be weatherproof external type mounted on the bottom of letters "ON" in the up position. Westrim or Granger or approved equal. • ALL PENETRATION of building structure is to be sealed watertight with 3M- silicon product. • ELECTRICAL COMPONENTS shall be in compliance with NFPA 70 (NEC) and UL 48 and bear laboratory approval. • SIGN AREA of wall structure shall be reinforced to provide the required structural support. • APPROVALS Sign manufacturer shall provide Winn -Dixie with shop drawings for approval. W C, JUNCTION BOX CONDUIT u 0 UC 1 NIL ,71'1CC I Ld & WIRING BY ELECTRICAL CONTRACTOR _0 ci i rj H LU 12 "X3/8 "DIA. IS .,,,' V) I' L -Z O 2 F_ C LO D � CONT. SEALANT I CI THREADED STAINLESS C 5/8` CDX FIRE TREATED PLYW( I BY GENERAL CONTRACTOR L STEEL THRU BOLTS 11 I TYPICAL ABS INSERT I I 3 12 "X318" DIA. STAINLESS STEEL NUT 8 WASHER STAINLESS SIGN LETTERS I IF= I too THREADED STAINLESS STE BY OTHERS STEEL) SEE NOTE STEEL THRU BOLTS EACH SIDE I I I TYPICAL UN II I CHANNEL LETTER c7Lf II _I I IIr I I III I CHANNEL LETTER I III I I I I LL _I I I d- I II r-II E.I.F.S. LJ I 12" X 3/8" DIA. I I I I k4d E I F S STAINLESS STEEL THREADED ROD I I I I I 16= 1 I II REFER MOUNTING DETAIL SHEET 111111 J RWR J 11 I __LL GALV. BOLTS AS REQ'D A I I BY SIGN CONTRACTOR REFER BLDG. SIGN SHEET 36' -1' WINN FDI.XI.9 v BUILDING IGN- BS9 T.S. (o' TUR9) — ACCESS— PANELS EACH SIDE 12" SQUARE STRUCTURAI POLES 13'-8" APHO T N BUILDING SIGN- BS6 N.T.S. (7" RETURNS) 8'a" PYLON SIGN N.T.S. REFER BLDG. SIGN SHEET 2 CHANNEL LETTERS SECTION DETAIL 23'-6" MARKETPLAC BUILDING SIGN- BS3 N.T.S. (7" RETURNS) FOO N BUILDING SIGN- BS4 N.T.S. (7" RETURNS) 22'-4" PHARMACY BUILDING SIGN- BS5 N.T.S. (7" RETURNS) 15' -0" i__" 01-1 " �4 COLORS LETTERS: TO MATCH, ATOHAAS #2328 WHITE WITH BLACK OUTLINE BACKGROUND: TO MATCH, ATOHAAS 42793 RED FONT BOOKMAN OLD STYLE, BOLD, ITALIC ABS INSERT TO BE SIZED AS NEEDED TO PREVENT CRUSHING OF E.I.F.S. 3 MOUNTING DETAIL 506 N.T.S. SPECIFICATIONS CHANNEL LETTERS • RETURNS (Sides) to be minimum .050 thick aluminum 7" or 10" (Refer: Building Sign Plans). .050 aluminum shall receive MIG welded construction 1" on center with fill seam to protect from weather. .063 aluminum shall receive continuous weld. Returns shall be acid or mechanically etched, primed and sprayed finished with Dupont (or better) automotive type finish. Color to match Mathews, Brushed Aluminum 41 -342. Each upright portion of the letters is to receive a 3/16" weep hole. • BACKS of letters to be minimum .063 thick aluminum. Reinforcement of channel letters with 4" high aluminum gussets epoxied or welded to inside wall of letter also serves as neon tube support base. • PAINT FINISH All interior aluminum components to be acid or mechanically etched, primed and sprayed finished with Dupont (or better) automotive type finish. Color: White gloss for maximum illumination. • FACE OF LETTERS 24 "or more high to be 0.150 Implex or Crylex brand acrylic plastic heat formed to a depth of 1 Y ". Color to match AtoHaas #2793 Red. • FACE OF LETTERS Less than 24" in height to be 4.5mm flat Implex brand acrylic plastic or 0.150 Flat Crylex brand acrylic plastic. Color to match AtoHaas #2793 Red. • FONT is to be Bookman Old Style, Bold, Italic. • RETAINER CAP for letters 24" or less in height to be plastic coated aluminum jewel trim, Color: Black. (Standard industrymethod). • RETAINER CAP for letters 24" or greater in height to be to 1/2"x 3/4" x .063 extruded aluminum angle bonded to sign face with 3M or Lord epoxy. Color: Black. • NEON tubing to be 15 mm clear voltarc glass with 45 M. A. electrodes for letters to be driven at 30 M.A. Any letters that require 60 M.A. transformers shall have 90 M.A. rated electrodes. All letters are required to have a minimum of two strokes of neon. On larger letters, all neon tubes shall be spaced at min. 4' center to center, with the outside tube being no more than 1 -1/2 from the letter wall. Tube supports to be aluminum or brass base fastened to W VIIIU VVllll LID 11VII0. nn nGVII IMIII.J, dIV W UC liaunt:atuu III accordance to Eurocom specifications, utilizing EuroLite or EGL ceramic collar electrodes and H Gas. Tube processing shall be performed on an electronically controlled bomborder at 30,000 volts, at a tube pressure of no more than 2 millitorr. Pumping shall be performed on turbo molecular pump to achieve a tube pressure of .8 millitorr. • ELECTRICAL All high voltage wiring shall be 100 percent pure silicone, heavy duty Tough Hide GTO cable rated for 15,000 volts. For exterior wiring requirements, conduit shall be aluminum Liquid - Lite. All wiring and components are to be UL approved. Connection 900 watertight connector and "sealtight" flexible conduit to be field verified (6' to 12). Wire to be #12 THHN stranded copper. • TRANSFORMER Pi3KM type France (or approved equal) transformers shall be used on all letters not mounted on raceways. D -2 housings in lieu of jumps shall be used on the internal wiring of letters. Transformers to be 30 M.A. and are not to exceed 9,000 volts secondary power output. Transformers shall be loaded as per manufacturers' recommendations. • STAND OFF MOUNTING OPTIONS Refer Detail • FLUSH MOUNTING OPTION Refer Detail • RACEWAY MOUNTING OPTION Refer Detail • DISCONNECT TOGGLE SWITCH Each branch circuit supplying a set or sets of letters will have an external and visible disconnect switch as per NEC 600 -6. The switch shall be weatherproof external type mounted on the bottom of letters "ON" in the up position. Westrim or Granger or approved equal. • ALL PENETRATION of building structure is to be sealed watertight with 3M- silicon product. • ELECTRICAL COMPONENTS shall be in compliance with NFPA 70 (NEC) and UL 48 and bear laboratory approval. • SIGN AREA of wall structure shall be reinforced to provide the required structural support. • APPROVALS Sign manufacturer shall provide Winn -Dixie with shop drawings for approval. TYPICAL SIGN LETTER %4MOUNTING DETAIL 5061 N.T.S. MAGNETIC LUMINOUS TUBE TRANSFORMER GENERAL • Magnetic core, 60- cycle, 30 MA. neon transformer. • Proper electrical size to be determined by a current and a flicker voltage test. • All transformers must be UL 2161 recognized. • Load: Red Neon 85 %, 25.5 M.A. • White mercury 80 %, 24 MA. DESIGN • Construction of transformer laminations should be of a crucible design incorporating a tooled gap for control of short circuit current. 1.1 High voltage coils shall be vacuum impregnated, virtually eliminating corona and preventing magnet wire degradation. 1.2 Transformer potting material shall be a two -part resin that does not reliquify. 1.3 Granular silica shall be vibrated into two -part resin prior to curing to facilitate heat transfer and extend life. 1.4 Internal mount, electrode housing style transformers shall have 36" primary leads to reduce cost of additional junction boxes. WARRANTY • Transformer must have a three -year warranty from date of manufacturing. PYLON SIGN FACES • 0.150 Implex, DR or Crylex brand acrylic plastic heat formed (panformed) faces with embossed graphics to a depth of 1 '/Y ". Colors to match AtoHaas #2793 Red (background) and #7328 White (letters). Sign faces requiring of two sections of facing shall be joined by a structural type connection. Refer Pylon Signs and Sign Graphic Sheets. FONT • Is to be Bookman Old Style, Bold, Italic. F)%rF nFcnr, ",1IUty I Vinyl 1' surface computer generated: a. 3M 3230 Series b. Macmark 9700 Series c. Oracal 8500 Series SIGN CABINET • Depth of sign cabinet shall be no less than 1'-8" and not exceed 2'- 2". • .063 aluminum minimum. • Internal bracing shall meet all local and state codes and shall accommodate match place type connection to sign poles. • Internal bracing shall be cleaned and primed all surfaces, and painted gloss white all exposed surfaces. • Exterior skin and frame sign with service doors on both sides or at the bottom (Refer: Pylon Pole Configuration Sheet) 20" x 30" for ease of access. Hinged sign face retainers may be used in lieu of access panels (See Sign Face Retainer below) SIGN FACE RETAINER • 2" x 2"x 3/16" extruded aluminum angle, structurally hinged system, painted to match sign box bonded to sign face with 3M or Lord epoxy and screw to sign cabinet, or same unhinged with access panels (See Sign Cabinet above). Color to match sign box. ILLUMINATION • Horizontal high output fluorescent lamps 12" on center in Mfg. .063 raceway with all ballasts, sockets, wiring, switches, and inline fuses in enclosed raceway to comply with NFPA 70 and UL 48 section electrical. Disconnect switches shall comply with NEC 600 -6. BALLAST • Approved type UL 48 a. Magnatek b. LJlIveisal c. Jefferson SIGN CABINET COLOR • Exterior skin shall be acid or mechanically etched, primed and sprayed finished with Dupont (or better) automotive type finish. IWCA(A IJJJ I000 1 '•! Iti i0 '000 iLS Cd id6C5 1000 II ?`i u7 IOD SIGN POLE COLOR • Shall be cleaned and primed all surfaces with Coronado Ruscat or equal. • Color to match Mathews, Brushed Aluminum 41 -342. APPROVALS • Sign manufacturer shall provide Winn -Dixie with shop drawings for approval. NOTE • Pylon sign must be in conformance with NFPA (NEC) section 600 and must bear UL or ETL label. All applicable building codes and/or other city codes must be adhered to. STRUCTURAL SIGNS • Structural elements of the signs shall be in compliance with all local and state codes. POLES • Support column minimum .5 -inch wall (1) 12" square structural steel. For sizes refer structural. MATCH PLATES • Shall be welded to pole for bolted connection to sign. Refer structural steel drawing(s) provided by sign manufacturer's structural engineer. BASE PLATES • Shall be welded to pole for bolted connection to foundation. Refer structural steel drawing provided by sign manufacturer's structural engineer. FOUNDATION • Augered or spread. Refer structural. APPROVALS • A structural drawing of the foundation, poles and connections, sealed by a licensed structural engineer is to be furnished to Winn - Dixie for approval. NOTES 1. The sign contractor shall verify all dimensions. 2. The sign contractor shall notify Winn -Dixie prior to the start of construction. 3. The sign contractor shall be responsible for obtaining all necessary permits, 4. The sign contractor shall provide Winn -Dixie with shop drawings and structural drawings (Refer: Structural — Approvals) for approval. 5. The tenant's signage shall be submitted to Winn -Dixie for approval. 6. All signs to be a UL approved assembly. 7. All pylon signs and sign replacement faces shall be two faces per sign. 8. Provide sign warranty and insurance information. 9. When mounting letters to wall surface, sign contractor shall provide any additional reinforcement necessary to make the connection structurally sound. NOTES: 1. SIGNS SUPPLIED AND INSTALLED BY WINN -DIXIE 2. BASE AND SERVICES SUPPLIED BY GENERAL- CONTRACTOR' � _(D n, N W 7—) U O O F - W) (D W O Ld O r , O � LO r (n LL. t H Q 00 • ^ � � (n LO N W U 0 O O ZJ O `. C) O� qI t\ Q J Q U) 2 H h h ENGINEERS REVISIONS: b Y co Low � q E z o ►-� C, A Q � N w00 A� w . W rn 0 C5 �w ,V O Ld w o 0 ® U Q v A W C, JUNCTION BOX CONDUIT u 0 ;L , Ld & WIRING BY ELECTRICAL CONTRACTOR _0 ci .W rj H LU IS .,,,' V) I' L -Z O 2 F_ C LO D � C O CI C 5/8` CDX FIRE TREATED PLYW( I BY GENERAL CONTRACTOR L TYPICAL SIGN LETTER %4MOUNTING DETAIL 5061 N.T.S. MAGNETIC LUMINOUS TUBE TRANSFORMER GENERAL • Magnetic core, 60- cycle, 30 MA. neon transformer. • Proper electrical size to be determined by a current and a flicker voltage test. • All transformers must be UL 2161 recognized. • Load: Red Neon 85 %, 25.5 M.A. • White mercury 80 %, 24 MA. DESIGN • Construction of transformer laminations should be of a crucible design incorporating a tooled gap for control of short circuit current. 1.1 High voltage coils shall be vacuum impregnated, virtually eliminating corona and preventing magnet wire degradation. 1.2 Transformer potting material shall be a two -part resin that does not reliquify. 1.3 Granular silica shall be vibrated into two -part resin prior to curing to facilitate heat transfer and extend life. 1.4 Internal mount, electrode housing style transformers shall have 36" primary leads to reduce cost of additional junction boxes. WARRANTY • Transformer must have a three -year warranty from date of manufacturing. PYLON SIGN FACES • 0.150 Implex, DR or Crylex brand acrylic plastic heat formed (panformed) faces with embossed graphics to a depth of 1 '/Y ". Colors to match AtoHaas #2793 Red (background) and #7328 White (letters). Sign faces requiring of two sections of facing shall be joined by a structural type connection. Refer Pylon Signs and Sign Graphic Sheets. FONT • Is to be Bookman Old Style, Bold, Italic. F)%rF nFcnr, ",1IUty I Vinyl 1' surface computer generated: a. 3M 3230 Series b. Macmark 9700 Series c. Oracal 8500 Series SIGN CABINET • Depth of sign cabinet shall be no less than 1'-8" and not exceed 2'- 2". • .063 aluminum minimum. • Internal bracing shall meet all local and state codes and shall accommodate match place type connection to sign poles. • Internal bracing shall be cleaned and primed all surfaces, and painted gloss white all exposed surfaces. • Exterior skin and frame sign with service doors on both sides or at the bottom (Refer: Pylon Pole Configuration Sheet) 20" x 30" for ease of access. Hinged sign face retainers may be used in lieu of access panels (See Sign Face Retainer below) SIGN FACE RETAINER • 2" x 2"x 3/16" extruded aluminum angle, structurally hinged system, painted to match sign box bonded to sign face with 3M or Lord epoxy and screw to sign cabinet, or same unhinged with access panels (See Sign Cabinet above). Color to match sign box. ILLUMINATION • Horizontal high output fluorescent lamps 12" on center in Mfg. .063 raceway with all ballasts, sockets, wiring, switches, and inline fuses in enclosed raceway to comply with NFPA 70 and UL 48 section electrical. Disconnect switches shall comply with NEC 600 -6. BALLAST • Approved type UL 48 a. Magnatek b. LJlIveisal c. Jefferson SIGN CABINET COLOR • Exterior skin shall be acid or mechanically etched, primed and sprayed finished with Dupont (or better) automotive type finish. IWCA(A IJJJ I000 1 '•! Iti i0 '000 iLS Cd id6C5 1000 II ?`i u7 IOD SIGN POLE COLOR • Shall be cleaned and primed all surfaces with Coronado Ruscat or equal. • Color to match Mathews, Brushed Aluminum 41 -342. APPROVALS • Sign manufacturer shall provide Winn -Dixie with shop drawings for approval. NOTE • Pylon sign must be in conformance with NFPA (NEC) section 600 and must bear UL or ETL label. All applicable building codes and/or other city codes must be adhered to. STRUCTURAL SIGNS • Structural elements of the signs shall be in compliance with all local and state codes. POLES • Support column minimum .5 -inch wall (1) 12" square structural steel. For sizes refer structural. MATCH PLATES • Shall be welded to pole for bolted connection to sign. Refer structural steel drawing(s) provided by sign manufacturer's structural engineer. BASE PLATES • Shall be welded to pole for bolted connection to foundation. Refer structural steel drawing provided by sign manufacturer's structural engineer. FOUNDATION • Augered or spread. Refer structural. APPROVALS • A structural drawing of the foundation, poles and connections, sealed by a licensed structural engineer is to be furnished to Winn - Dixie for approval. NOTES 1. The sign contractor shall verify all dimensions. 2. The sign contractor shall notify Winn -Dixie prior to the start of construction. 3. The sign contractor shall be responsible for obtaining all necessary permits, 4. The sign contractor shall provide Winn -Dixie with shop drawings and structural drawings (Refer: Structural — Approvals) for approval. 5. The tenant's signage shall be submitted to Winn -Dixie for approval. 6. All signs to be a UL approved assembly. 7. All pylon signs and sign replacement faces shall be two faces per sign. 8. Provide sign warranty and insurance information. 9. When mounting letters to wall surface, sign contractor shall provide any additional reinforcement necessary to make the connection structurally sound. NOTES: 1. SIGNS SUPPLIED AND INSTALLED BY WINN -DIXIE 2. BASE AND SERVICES SUPPLIED BY GENERAL- CONTRACTOR' � _(D n, N W 7—) U O O F - W) (D W O Ld O r , O � LO r (n LL. t H Q 00 • ^ � � (n LO N W U 0 O O ZJ O `. C) O� qI t\ Q J Q U) 2 H h h ENGINEERS REVISIONS: b Y co Low � q E z o ►-� C, A Q � N w00 A� w . W rn 0 C5 �w ,V O Ld w o 0 ® U Q v A DRAWING TITLE SIGNAGE DETAILS DATE: JUNE 17, 2002 DRAWN BY: CHECKED BY: DIVISION MIAMI LOCATION NO. 285 W.D. GUIDE PLAN PROJECT NO. WD #0704 DRAWING NO. A -506 OF SHEET NO. OF l W C, ;L , Ld L!' _0 „ .W rj X LU IS .,,,' V) I' -Z O 2 F_ Z LO D � 00 O DRAWING TITLE SIGNAGE DETAILS DATE: JUNE 17, 2002 DRAWN BY: CHECKED BY: DIVISION MIAMI LOCATION NO. 285 W.D. GUIDE PLAN PROJECT NO. WD #0704 DRAWING NO. A -506 OF SHEET NO. OF l